Rapid SARS-CoV-2 Detection Using Electrochemical Immunosensor
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The outbreak of the coronavirus disease (COVID-19) pandemic caused by the novel coronavirus (SARS-CoV-2) has been declared an international public health crisis. It is essential to develop diagnostic tests that can quickly identify infected individuals to limit the spread of the virus and assign treatment options. Herein, we report a proof-of-concept label-free electrochemical immunoassay for the rapid detection of SARS-CoV-2 virus via the spike surface protein. The assay consists of a graphene working electrode functionalized with anti-spike antibodies. The concept of the immunosensor is to detect the signal perturbation obtained from ferri/ferrocyanide measurements after binding of the antigen during 45 min of incubation with a sample. The absolute change in the [Fe(CN)6]3−/4− current upon increasing antigen concentrations on the immunosensor surface was used to determine the detection range of the spike protein. The sensor was able to detect a specific signal above 260 nM (20 µg/mL) of subunit 1 of recombinant spike protein. Additionally, it was able to detect SARS-CoV-2 at a concentration of 5.5 × 105 PFU/mL, which is within the physiologically relevant concentration range. The novel immunosensor has a significantly faster analysis time than the standard qPCR and is operated by a portable device which can enable on-site diagnosis of infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,847
An interactive web-based dashboard to track COVID-19 in real time
Dong, E., Du, H., & Gardner, L. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30120-1 · Cited by 10,048 · cited 1×
“8 million people worldwide to date [1,2].”
Genome Composition and Divergence of the Novel Coronavirus (2019-nCoV) Originating in China
Wu, A., Peng, Y., Huang, B., Ding, X., Wang, X., Niu, P., Meng, J., Zhu, Z., Zhang, Z., Wang, J., et al. (2020) · Cell Host & Microbe · doi:10.1016/j.chom.2020.02.001 · Cited by 2,361 · cited 2×
“However, as discussed earlier, the nucleocapsid protein shares high similarity to other coronaviruses, and thus could increase the risk of false-positive detection [10,11].”
BackgroundRissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119 · cited 1×
“This will result in a rapid buildup of fluorescence if a labelled protein is present on an antibody-labelled bead, which allows for single-molecule detection and, on average, offers 1000-fold greater sensitivity than conventional immunoassays [30,31].”
BackgroundSeo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837
Ahmed, S. F., Quadeer, A. A., & McKay, M. R. (2020) · Viruses · doi:10.3390/v12030254 · Cited by 1,116
Clinical and virological data of the first cases of COVID-19 in Europe: a case series
Lescure, F.-X., Bouadma, L., Nguyen, D., Parisey, M., Wicky, P.-H., Behillil, S., Gaymard, A., Bouscambert-Duchamp, M., Donati, F., Le Hingrat, Q., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30200-0 · Cited by 1,092
Pang, J., Wang, M. X., Ang, I. Y. H., Tan, S. H. X., Lewis, R. F., Chen, J. I.-P., Gutierrez, R. A., Gwee, S. X. W., Chua, P. E. Y., Yang, Q., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030623 · Cited by 553 · cited 6×
“The current global standard testing strategy, as recommended by the World Health Organization (WHO, Geneva, Switzerland), for the detection of SARS-CoV-2 virus targets viral RNA using polymerase chain reaction (PCR) [3,4].”
MethodInfluentialWilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Fabiani, L., Saroglia, M., Galatà, G., De Santis, R., Fillo, S., Luca, V., Faggioni, G., D'Amore, N., Regalbuto, E., Salvatori, P., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112686 · Cited by 434
Ahmadivand, A., Gerislioglu, B., Ramezani, Z., Kaushik, A., Manickam, P., & Ghoreishi, S. A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.112971 · Cited by 314
Nguyen, T., Duong Bang, D., & Wolff, A. (2020) · Micromachines · doi:10.3390/mi11030306 · Cited by 291
Ahmed, S. F., Quadeer, A. A., & McKay, M. R. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.02.03.933226 · Cited by 257 · cited 2×
“However, as discussed earlier, the nucleocapsid protein shares high similarity to other coronaviruses, and thus could increase the risk of false-positive detection [10,11].”
BackgroundMahari, S., Roberts, A., Shahdeo, D., & Gandhi, S. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.04.24.059204 · Cited by 246 · cited 1×
“have also shown a proof-of-concept of a similar screen-printed electrode (SPE) biosensor against the Spike antigen, as well as a homemade potentiostat for reading the SPE with a limit of detection of 10 fM in saliva within 30 s [24].”
BackgroundMavrikou, S., Moschopoulou, G., Tsekouras, V., & Kintzios, S. (2020) · Sensors · doi:10.3390/s20113121 · Cited by 236
A review on viral biosensors to detect human pathogens
Caygill, R. L., Blair, G. E., & Millner, P. A. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.09.038 · Cited by 230
Ultrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art
Khan, M. Z. H., Hasan, M. R., Hossain, S. I., Ahommed, M. S., & Daizy, M. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112431 · Cited by 224
Nano-enabled biosensing systems for intelligent healthcare: towards COVID-19 management
Mujawar, M. A., Gohel, H., Bhardwaj, S. K., Srinivasan, S., Hickman, N., & Kaushik, A. (2020) · Materials Today Chemistry · doi:10.1016/j.mtchem.2020.100306 · Cited by 223
Kaushik, A. K., Dhau, J. S., Gohel, H., Mishra, Y. K., Kateb, B., Kim, N.-Y., & Goswami, D. Y. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01004 · Cited by 222
Biosensors: frontiers in rapid detection of COVID-19
Samson, R., Navale, G. R., & Dharne, M. S. (2020) · 3 Biotech · doi:10.1007/s13205-020-02369-0 · Cited by 186
Review—Chemical and Biological Sensors for Viral Detection
Özer, T., Geiss, B. J., & Henry, C. S. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0232003jes · Cited by 144
The role of biosensors in coronavirus disease-2019 outbreak
Asif, M., Ajmal, M., Ashraf, G., Muhammad, N., Aziz, A., Iftikhar, T., Wang, J., & Liu, H. (2020) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2020.08.011 · Cited by 136 · cited 1×
“The importance of rapid testing for the prevention of new cases has been discussed widely [7,8].”
BackgroundComparing the analytical performance of three SARS-CoV-2 molecular diagnostic assays
Uhteg, K., Jarrett, J., Richards, M., Howard, C., Morehead, E., Geahr, M., Gluck, L., Hanlon, A., Ellis, B. C., Kaur, H. B., et al. (2020) · Journal of Clinical Virology · doi:10.1016/j.jcv.2020.104384 · Cited by 112 · cited 1×
“In comparison, commercial PCR-based methods have a sensitivity of approximately 1200 viral genome copies/mL [25].”
MethodField-Effect Sensors for Virus Detection: From Ebola to SARS-CoV-2 and Plant Viral Enhancers
Poghossian, A., Jablonski, M., Molinnus, D., Wege, C., & Schöning, M. J. (2020) · Frontiers in Plant Science · doi:10.3389/fpls.2020.598103 · Cited by 83
Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas aeruginosa: A Focused Review
Alatraktchi, F. A., Svendsen, W. E., & Molin, S. (2020) · Sensors · doi:10.3390/s20185218 · Cited by 81
Self-citationThe potential of electrochemistry for the detection of coronavirus-induced infections
Lim, R. R. X., & Bonanni, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116081 · Cited by 49
Olsen, D. A., Thomsen, C. B., Andersen, R. F., Madsen, J. S., Jakobsen, A. K. M., & Brandslund, I. (2020) · Scientific Reports · doi:10.1038/s41598-020-77109-8 · Cited by 6 · cited 1×
“Using four parameters logistic fitting, the protein concentration was interpolated from the calibrator curve [26].”
MethodSelf-citation
Cited by
COVID-19 Point-of-Care Diagnostics: Present and Future
Valera, E., Jankelow, A., Lim, J., Kindratenko, V., Ganguli, A., White, K., Kumar, J., & Bashir, R. (2021) · ACS Nano · doi:10.1021/acsnano.1c02981 · Cited by 181
Zhang, Z., Pandey, R., Li, J., Gu, J., White, D., Stacey, H. D., Ang, J. C., Steinberg, C., Capretta, A., Filipe, C. D. M., et al. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202110819 · Cited by 169
Metadata
- Authors
- Mojsoska, B., Larsen, S., Olsen, D. A., Madsen, J. S., Brandslund, I., & Alatraktchi, F. A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-01-08
- Volume
- 21
- Issue
- 2
- Pages
- 390
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3118593024
- Cited by
- 206
- References
- 27
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.