Smart Textiles and Sensorized Garments for Physiological Monitoring: A Review of Available Solutions and Techniques
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Several wearable devices for physiological and activity monitoring are found on the market, but most of them only allow spot measurements. However, the continuous detection of physiological parameters without any constriction in time or space would be useful in several fields such as healthcare, fitness, and work. This can be achieved with the application of textile technologies for sensorized garments, where the sensors are completely embedded in the fabric. The complete integration of sensors in the fabric leads to several manufacturing techniques that allow dealing with both the technological challenges entailed by the physiological parameters under investigation, and the basic requirements of a garment such as perspiration, washability, and comfort. This review is intended to provide a detailed description of the textile technologies in terms of materials and manufacturing processes employed in the production of sensorized fabrics. The focus is pointed at the technical challenges and the advanced solutions introduced with respect to conventional sensors for recording different physiological parameters, and some interesting textile implementations for the acquisition of biopotentials, respiratory parameters, temperature and sweat are proposed. In the last section, an overview of the main garments on the market is depicted, also exploring some relevant projects under development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107 · cited 7×
“, European Medical Device Regulation, Food and Drug Administration) so as to be produced and marketed in compliance with safety standards [3,4].”
BackgroundInfluentialWearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931 · cited 1×
“Finally, if garments are used for energy harvesting and electricity generation as well as for physiological measurements, additional specifications are introduced in the manufacturing process [14].”
BackgroundFlexible Electronics: Stretchable Electrodes and Their Future
Huang, S., Liu, Y., Zhao, Y., Ren, Z., & Guo, C. F. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805924 · Cited by 855 · cited 2×
“Finally, flexible epidermal electronic technologies constitute a new frontier of electrodes for garments: they are both transparent and resistant to different types of mechanical deformation more effectively than fabric electrodes [109].”
BackgroundSmart textiles: Challenges and opportunities
Cherenack, K., & van Pieterson, L. (2012) · Journal of Applied Physics · doi:10.1063/1.4742728 · Cited by 602 · cited 1×
“They are also referred to as “smart textiles” to highlight the ability to accomplish functions that common clothes cannot fulfil [4] in various sectors, among which are healthcare [9] and industry [10].”
BackgroundContact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426 · cited 1×
“Different methods have been recently developed to track the respiratory parameters outside of the clinical environment, and sensorized clothes fit well in this context because of their comfort, practicality, and non-invasiveness [62].”
MethodChest wall and lung volume estimation by optical reflectance motion analysis
Cala, S. J., Kenyon, C. M., Ferrigno, G., Carnevali, P., Aliverti, A., Pedotti, A., Macklem, P. T., & Rochester, D. F. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2680 · Cited by 377 · cited 1×
“[73] compared a smart garment with six piezoresistive elements with the results obtained with optoelectronic plethysmography [74]: the difference between the average respiratory frequency was always lower than 1% and 4% during quiet breathing and tachypnea, respectively.”
ResultSelf-citationFernández-Caramés, T., & Fraga-Lamas, P. (2018) · Electronics · doi:10.3390/electronics7120405 · Cited by 359 · cited 1×
“Overview of some garments available on the market or in research settings [79].”
BackgroundNovel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336 · cited 1×
“2 mm thick taffeta material and benchmarked against standard electrodes, showing a high correlation of ~96% and ~90% from the forehead and hairy sites on the head [48].”
BackgroundWearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K. (2019) · Electronics · doi:10.3390/electronics8050479 · Cited by 315 · cited 9×
“Finally, the electrodes in both cases are represented by the potential Ehc [27].”
BackgroundMethodInfluentialConductive polymers for smart textile applications
Grancarić, A. M., Jerković, I., Koncar, V., Cochrane, C., Kelly, F. M., Soulat, D., & Legrand, X. (2018) · Journal of Industrial Textiles · doi:10.1177/1528083717699368 · Cited by 286 · cited 2×
“These organic polymers unite both metals’ electrical properties and plastics’ mechanical features [31].”
BackgroundEnhancing the Performance of Stretchable Conductors for E‐Textiles by Controlled Ink Permeation
Jin, H., Matsuhisa, N., Lee, S., Abbas, M., Yokota, T., & Someya, T. (2017) · Advanced Materials · doi:10.1002/adma.201605848 · Cited by 283 · cited 1×
“A solution that has been found to this problem consisted of controlling the ink permeation in the structure of the textile by adjusting the ink’s solvent [37].”
MethodPerformance Evaluation of Sensing Fabrics for Monitoring Physiological and Biomechanical Variables
Scilingo, E. P., Gemignani, A., Paradiso, R., Taccini, N., Ghelarducci, B., & DeRossi, D. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854506 · Cited by 247
Wearable technology: role in respiratory health and disease
Aliverti, A. (2017) · Breathe · doi:10.1183/20734735.008417 · Cited by 243
Self-citationBio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S., Wu, Y., Lau, K. T., Wallace, G., & Diamond, D. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 235
PEDOT:PSS-Based Conductive Textiles and Their Applications
Tseghai, G. B., Mengistie, D. A., Malengier, B., Fante, K. A., & Van Langenhove, L. (2020) · Sensors · doi:10.3390/s20071881 · Cited by 234 · cited 2×
“In general, the fibres are composed of a core made of cotton, polyester and lycra, whilst the metals chosen for coating purposes are mainly silver, stainless steel and copper, whose characteristics are listed in Table 2 [4,21,22,27].”
BackgroundTextile sensors for wearable applications: a comprehensive review
Islam, G. M. N., Ali, A., & Collie, S. (2020) · Cellulose · doi:10.1007/s10570-020-03215-5 · Cited by 226 · cited 1×
“While there are reviews focused only on the aspect of the materials composing the fabric [15,16] and others focused only on the physiological measurements that can be obtained, the purpose of the presented work is to provide the reader with a broader overview of all the aspects related to smart textiles for physiologi…”
BackgroundMokhtari, F., Cheng, Z., Raad, R., Xi, J., & Foroughi, J. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta00227e · Cited by 205 · cited 1×
“The presented paper is a focused literature review of current, high-quality articles in the field of smart textiles and sensorized garments, and information is obtained from scientific journals in various fields, including but not limited to biomedical engineering, electronics, materials science, information technolog…”
BackgroundDirect patterning of organic conductors on knitted textiles for long-term electrocardiography
Takamatsu, S., Lonjaret, T., Crisp, D., Badier, J.-M., Malliaras, G. G., & Ismailova, E. (2015) · Scientific Reports · doi:10.1038/srep15003 · Cited by 195
Characterization of textile electrodes and conductors using standardized measurement setups
Beckmann, L., Neuhaus, C., Medrano, G., Jungbecker, N., Walter, M., Gries, T., & Leonhardt, S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/2/009 · Cited by 192 · cited 1×
“The models of the skin and electrode-electrolyte interface [41] are based on the combination of equivalent circuits for the electrode-electrolyte interface [42] and equivalent circuits of the skin [43].”
Romei, M., Mauro, A. L., D’Angelo, M. G., Turconi, A. C., Bresolin, N., Pedotti, A., & Aliverti, A. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.05.018 · Cited by 187 · cited 1×
“, only one degree of freedom is considered in the model [66], while it is known from the literature that the rib cage and the abdomen give different contributions to the tidal volume with changing postures [67].”
BackgroundSelf-citationOverview of wearable electronics and smart textiles
Ghahremani Honarvar, M., & Latifi, M. (2017) · The Journal of The Textile Institute · doi:10.1080/00405000.2016.1177870 · Cited by 183 · cited 3×
“While there are reviews focused only on the aspect of the materials composing the fabric [15,16] and others focused only on the physiological measurements that can be obtained, the purpose of the presented work is to provide the reader with a broader overview of all the aspects related to smart textiles for physiologi…”
BackgroundValidation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities
Villar, R., Beltrame, T., & Hughson, R. L. (2015) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2015-0140 · Cited by 178 · cited 2×
“The user can also visualize the data on Hexoskin Online Dashboard, whereas healthcare professionals, researchers and technicians can employ the advanced VivoSense analysis software to import/export data, batch processing, and to produce ready-to-publish graphs [81].”
BackgroundMethodSmart textiles for medicine and healthcare
Van Langenhove, L. (2007) · Woodhead Publishing Limited eBooks · doi:10.1533/9781845692933 · Cited by 176 · cited 2×
“Weft knitted fabrics, produced in flat or tubular form, are highly elastic and drapeable, while warp knitted fabrics are not much elastic while difficult to reveal [18,28].”
BackgroundCapacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174 · cited 1×
“The same-time-different-location comparison with a calibrated device is a general method to evaluate the performance of a new device [57] and different examples can be found in the literature, showing good correlation results [58].”
BackgroundIntelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors
Yapici, M., & Alkhidir, T. (2017) · Sensors · doi:10.3390/s17040875 · Cited by 166
Measurement of EMG activity with textile electrodes embedded into clothing
Finni, T., Hu, M., Kettunen, P., Vilavuo, T., & Cheng, S. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/007 · Cited by 160 · cited 2×
“The critical aspects regarding surface EMG measurements concern motion artifacts, skin-electrode impedance, which depends on the garment fit, and repeatability of the measurements due to changes in electrodes placement [44,45].”
BackgroundSmart Garments for Emergency Operators: The ProeTEX Project
Curone, D., Secco, E. L., Tognetti, A., Loriga, G., Dudnik, G., Risatti, M., Whyte, R., Bonfiglio, A., & Magenes, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2045003 · Cited by 141 · cited 2×
“A built-in processor triggered the best-located transmitters to obtain the highest signal level [70].”
BackgroundReview on Smart Electro-Clothing Systems (SeCSs)
Muhammad Sayem, A. S., Hon Teay, S., Shahariar, H., Luise Fink, P., & Albarbar, A. (2020) · Sensors · doi:10.3390/s20030587 · Cited by 132 · cited 5×
“Weft knitted fabrics, produced in flat or tubular form, are highly elastic and drapeable, while warp knitted fabrics are not much elastic while difficult to reveal [18,28].”
BackgroundMethodInfluentialTwo‐Layered and Stretchable e‐Textile Patches for Wearable Healthcare Electronics
La, T., Qiu, S., Scott, D. K., Bakhtiari, R., Kuziek, J. W. P., Mathewson, K. E., Rieger, J., & Chung, H. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201801033 · Cited by 124
Continuous Temperature-Monitoring Socks for Home Use in Patients With Diabetes: Observational Study
Reyzelman, A. M., Koelewyn, K., Murphy, M., Shen, X., Yu, E., Pillai, R., Fu, J., Scholten, H. J., & Ma, R. (2018) · Journal of Medical Internet Research · doi:10.2196/12460 · Cited by 121 · cited 1×
“Socks Siren Foot temperature Bluetooth (Siren app) Above the ankle [88]”
BackgroundA review-application of physical vapor deposition (PVD) and related methods in the textile industry
Shahidi, S., Moazzenchi, B., & GHORANNEVISS, M. (2015) · The European Physical Journal Applied Physics · doi:10.1051/epjap/2015140439 · Cited by 120 · cited 1×
“The solid coating material is evaporated by heat or by bombardment with ions, such as in the case of sputtering; at the same time, the introduction of a reactive gas in the vacuum forms a compound with the metal vapor and is deposited on the substrate as thin film [25].”
BackgroundPhotonic textiles for pulse oximetry
Rothmaier, M., Selm, B., Spichtig, S., Haensse, D., & Wolf, M. (2008) · Optics Express · doi:10.1364/oe.16.012973 · Cited by 111 · cited 1×
“Instead, the embroidered fabric resulted as more feasible, and with an SNR directly proportional to the number of optical fibres and the light intensity [64].”
BackgroundSoft Smart Garments for Lower Limb Joint Position Analysis
Totaro, M., Mondini, A., Lucarotti, C., Poliero, T., Cairoli, G., Ortiz, J., & Beccai, L. (2017) · Sensors · doi:10.3390/s17102314 · Cited by 107 · cited 1×
“Even though the majority of garments are applied on the torso and upper limbs, there are also examples of sensing elements placed on the lower-limbs [78] and the head.”
BackgroundPsychometric properties of the Zephyr bioharness device: a systematic review
Nazari, G., Bobos, P., MacDermid, J. C., Sinden, K. E., Richardson, J., & Tang, A. (2018) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-018-0094-4 · Cited by 101 · cited 1×
“T-shirt, shirt, sports bra, strap Medtronic-ZephyrTM Performance Systems 88% PES, 12% Spandex ECG, RR, temperature, accelerometric data, time and location BLE (OmniSenseTM app) Plugs into the garments [95]”
MethodCan mHealth Technology Help Mitigate the Effects of the COVID-19 Pandemic?
Adans-Dester, C. P., Bamberg, S. J. M., Bertacchi, F., Caulfield, B., Chappie, K., Demarchi, D., Erb, M. K., Estrada, J., Fabara, E. E., Freni, M., et al. (2020) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2020.3015141 · Cited by 98 · cited 1×
“Furthermore, the recent worldwide spread of COVID-19 is forcing several healthcare providers to rethink the way services are provided and is leading to a faster digitalization process [1], thus paving the way to a more intensive use of wearable devices and remote monitoring solutions in the medical field.”
BackgroundHong, H., Hu, J., & Yan, X. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b06432 · Cited by 96 · cited 2×
“Moreover, the silver printed fabrics are washable, although the repeating washing can reduce the conductivity substantially [30].”
BackgroundMethodFiber-Optic Based Smart Textiles for Real-Time Monitoring of Breathing Rate
Issatayeva, A., Beisenova, A., Tosi, D., & Molardi, C. (2020) · Sensors · doi:10.3390/s20123408 · Cited by 94
Smart Textile Based on Piezoresistive Sensing Elements for Respiratory Monitoring
Massaroni, C., Tocco, J. D., Presti, D. L., Longo, U. G., Miccinilli, S., Sterzi, S., Formica, D., Saccomandi, P., & Schena, E. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2917617 · Cited by 93 · cited 1×
“[73] compared a smart garment with six piezoresistive elements with the results obtained with optoelectronic plethysmography [74]: the difference between the average respiratory frequency was always lower than 1% and 4% during quiet breathing and tachypnea, respectively.”
ResultKim, S., Lee, S., & Jeong, W. (2020) · Polymers · doi:10.3390/polym12102406 · Cited by 92 · cited 1×
“Textile-based electrodes used in a study denoted comparable performance to Ag/AgCl electrodes when the diameter of the electrode was greater than 20 mm and the applied pressure greater than 10 mmHg, while the baseline noise showed a tendency to increase with decreasing electrode size [53].”
MethodLynn, S. K., Watkins, C. M., Wong, M. A., Balfany, K., & Feeney, D. F. (2018) · Europe PMC (PubMed Central) · Cited by 92
A Home Telemedicine System for Continuous Respiratory Monitoring
Angelucci, A., Kuller, D., & Aliverti, A. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3012621 · Cited by 89 · cited 1×
“Furthermore, the advent of new mobile communication technologies, such as 5G, opens the door to a more systematic use of wearable sensors in general, and sensorized garments in particular, both for telemedicine and sports applications [108].”
BackgroundSelf-citationKańtoch, E. (2018) · Sensors · doi:10.3390/s18103219 · Cited by 87 · cited 1×
“needs such as athletes’ performance evaluation, patient remote monitoring, and rehabilitation in a safe and accurate way [6], leading the concept of wearable device closer and closer to what is commonly referred as a medical device.”
BackgroundTelemonitoring systems for respiratory patients: technological aspects
Angelucci, A., & Aliverti, A. (2020) · Pulmonology · doi:10.1016/j.pulmoe.2019.11.006 · Cited by 86 · cited 1×
“A complete monitoring system implies the presence of an effective communication protocol and reliable data management and processing [2].”
BackgroundSelf-citationLow temperature sintering nano-silver conductive ink printed on cotton fabric as printed electronics
Wang, Z., Wang, W., Jiang, Z., & Yu, D. (2016) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2016.08.019 · Cited by 84 · cited 1×
“For this reason, there are research and industrial efforts to do so with nanoparticles at lower temperatures in order not to damage the fabric itself [34,35].”
BackgroundDesign and fabrication of Temperature Sensing Fabric
Husain, M., Kennon, R., & Dias, T. (2013) · Journal of Industrial Textiles · doi:10.1177/1528083713495249 · Cited by 78 · cited 2×
“The traditional sensors used for temperature sensing are resistance temperature detectors (RTDs), thermistors, and thermocouples [75].”
BackgroundMethodChoudhry, N. A., Rasheed, A., Ahmad, S., Arnold, L., & Wang, L. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2994264 · Cited by 76
Recent Advancements in Wearable & Smart Textiles: An Overview
Singha, K., Kumar, J., & Pandit, P. (2019) · Materials Today Proceedings · doi:10.1016/j.matpr.2019.05.334 · Cited by 75
Technical Embroidery for Smart Textiles: Review
Mečņika, V., Hoerr, M., Krieviņš, I., Jockenhoevel, S., & Gries, T. (2015) · Materials Science Textile and Clothing Technology · doi:10.7250/mstct.2014.009 · Cited by 67 · cited 1×
“This technology is of interest in the field of smart textiles because of the possibility to lay the base material in all directions rather than in pre-defined ones [29]; because of this, an enhanced skin-electrode contact can be obtained [27].”
BackgroundWearable Contactless Respiration Sensor Based on Multi-Material Fibers Integrated into Textile
Guay, P., Gorgutsa, S., LaRochelle, S., & Messaddeq, Y. (2017) · Sensors · doi:10.3390/s17051050 · Cited by 62
Curone, D., Tognetti, A., Secco, E. L., Anania, G., Carbonaro, N., Rossi, D. D., & Magenes, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2047727 · Cited by 61 · cited 1×
“Another long-range communication occurs from the local post to the central emergency coordination [70,107].”
BackgroundMuscle Inactivity Is Adversely Associated with Biomarkers in Physically Active Adults
Pesola, A. J., Laukkanen, A., Tikkanen, O., Sipilä, S., Kainulainen, H., & Finni, T. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000527 · Cited by 61 · cited 1×
“71% polyamide, 29% elastane EMG Bluetooth (MBody Live 3 app) At the level of the waist [98]”
BackgroundHigh-density EMG E-Textile systems for the control of active prostheses
Farina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627455 · Cited by 57 · cited 2×
“A high density EMG was recorded using a sleeve on which 100 electrodes are placed and grouped in four 5 × 5 grids [50].”
BackgroundMethodEmbroidered Electromyography: A Systematic Design Guide
Shafti, A., Manero, R. B. R., Borg, A. M., Althoefer, K. A., & Howard, M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2633506 · Cited by 56 · cited 4×
“This last allows a better customization in the design and shape of the electrodes compared to knitted patterns, therefore, embroidered electrodes better adapt to different application and monitoring scenarios [45].”
BackgroundInfluentialAssessment of signal quality measured with a smart 12‐lead ECG acquisition T‐shirt
Fouassier, D., Roy, X., Blanchard, A., & Hulot, J. (2019) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12682 · Cited by 55 · cited 1×
“T-shirt BioserenityCardioskinTM 12-lead ECG Wi-Fi Attached at the level of the abdomen [92]”
BackgroundDefining Requirements and Related Methods for Designing Sensorized Garments
Andreoni, G., Standoli, C. E., & Perego, P. (2016) · Sensors · doi:10.3390/s16060769 · Cited by 52 · cited 4×
“55 billion USD in the next five years [5,13].”
BackgroundInfluentialCutaneous Recording and Stimulation of Muscles Using Organic Electronic Textiles
Papaiordanidou, M., Takamatsu, S., Rezaei‐Mazinani, S., Lonjaret, T., Martin, A., & Ismailova, E. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600299 · Cited by 50 · cited 3×
“The electromyogram allows the investigation of the complex cooperation of different muscular groups [39].”
BackgroundMethodInfluentialCharacterization of Textile-Insulated Capacitive Biosensors
Ng, C. L., & Reaz, M. B. I. (2017) · Sensors · doi:10.3390/s17030574 · Cited by 50 · cited 1×
“In general, the fibres are composed of a core made of cotton, polyester and lycra, whilst the metals chosen for coating purposes are mainly silver, stainless steel and copper, whose characteristics are listed in Table 2 [4,21,22,27].”
BackgroundCognitive Impact and Psychophysiological Effects of Stress Using a Biomonitoring Platform
Rodrigues, S., Paiva, J. S., Dias, D., Aleixo, M., Filipe, R. M., & Cunha, J. P. S. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15061080 · Cited by 49
Giminiani, R. D., Cardinale, M., Ferrari, M., & Quaresima, V. (2020) · Sensors · doi:10.3390/s20174664 · Cited by 43
Validity of the Polar Team Pro Sensor for measuring speed and distance indoors
Fox, J. L., O’Grady, C. J., Scanlan, A. T., et al. (2019) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2019.06.012 · Cited by 42 · cited 1×
“Vest Polar Electro Motion sensor, HR, GPS Bluetooth (Polar Flow app) Slides into the garment at the centre back of the neck [96]”
MethodComparison between the Airgo™ Device and a Metabolic Cart during Rest and Exercise
Antonelli, A., Guilizzoni, D., Angelucci, A., Melloni, G., Mazza, F., Stanzi, A., Venturino, M., Kuller, D., & Aliverti, A. (2020) · Sensors · doi:10.3390/s20143943 · Cited by 41
Self-citationMedical applications of smart textiles
Coyle, S. M., & Diamond, D. (2016) · Elsevier eBooks · doi:10.1016/b978-1-78242-379-9.00010-4 · Cited by 41 · cited 1×
“They are also referred to as “smart textiles” to highlight the ability to accomplish functions that common clothes cannot fulfil [4] in various sectors, among which are healthcare [9] and industry [10].”
BackgroundMatiko, J. W., Wei, Y., Torah, R. N., Grabham, N. J., Paul, G., Beeby, S., & Tudor, J. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/12/125028 · Cited by 40 · cited 1×
“The whole system is covered by a printed layer of dielectric and then by a printed layer of conductive material composed of carbon loaded rubber; an innovative element of this project concerns the power supply, based on solar panels [47].”
BackgroundSarmento, A., Vignati, C., Paolillo, S., Lombardi, C., Scoccia, A., Nicoli, F., Mapelli, M., Leonardi, A. D. C., Ossola, D., Rigoni, R., et al. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.06.044 · Cited by 36 · cited 2×
“app) Plug inside the shirt, on the back [84]”
BackgroundSelf-citationEvaluating the Sensoria Smart Socks Gait Monitoring System for Rehabilitation Outcomes
Yeung, J., Catolico, D., Fullmer, N. H., Daniel, R., Lovell, R., Tang, R., Pearson, E. M., & Rosenberg, S. (2019) · PM&R · doi:10.1002/pmrj.12003 · Cited by 27
Frerichs, I., Vogt, B., Wacker, J., Paradiso, R., Braun, F., Rapin, M., Caldani, L., Chételat, O., & Weiler, N. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab668f · Cited by 27 · cited 1×
“Single-lead ECG, respiratory signal, 3-axial accelerometer Bluetooth and Wi-Fi Ventral top right part of the chest [93]”
BackgroundStylios, G. K. (2020) · Materials · doi:10.3390/ma13040950 · Cited by 23 · cited 1×
“55 billion USD in the next five years [5,13].”
BackgroundFleury, A., Alizadeh, M., Stefan, G., & Chau, T. T. (2017) · IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2017.8268137 · Cited by 17 · cited 1×
“The electrodes were placed on the forehead to avoid hair interference demonstrating good functionality on long measurements while maintaining constant and high comfort [46].”
BackgroundFarina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Cited by 16
Yu, X., Böhm, A., Neu, W., Venema, B., Marx, N., Leonhardt, S. K., & Teichmann, D. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_176 · Cited by 13 · cited 1×
“The 12-leads are inferred from the combination of 10 textile electrodes based on electrically conductive fabric (Shieldex Med-tex P180, Statex, Bremen, Germany) [60].”
MethodValidity and reliability of textile system Sensoria for posturographic measurements
D’Addio, G., Iuppariello, L., Bifulco, P., Lanzillo, B., Pappone, N., & Cesarelli, M. (2025) · Giornale italiano di medicina del lavoro ed ergonomia · doi:10.4081/gimle.644 · Cited by 7 · cited 5×
“T-shirt, socks, bra Sensoria polyamide 70–90%, elastane 5–8%, polyester 0–18% HR, step count, cadence, stride, calories, altitude, distance Bluetooth (Sensoria Fitness App, third party apps) Connect to snap buttons under chest, fold sock over anklet [99]”
BackgroundInfluentialThe Method of Implementing the General Data Protection Regulation in Business and Administration
Pólkowski, Z. (2018) · International Conference on Electronics, Computers and Artificial Intelligence (ECAI) · doi:10.1109/ecai.2018.8679062 · Cited by 7 · cited 1×
“There are regional regulations regarding data ownership, such as the General Data Protection Regulation (GDPR) [8], but uniform worldwide regulations are lacking and this cannot be overlooked when thinking about a future where the use of wearable devices will be ordinary in medicine, sport, fitness, and more and more…”
BackgroundKatzburg, S., Dor‐Haim, H., Weiss, A. T., & Leibowitz, D. W. (2019) · European Heart Journal - Case Reports · doi:10.1093/ehjcr/ytz073 · Cited by 3 · cited 1×
“HR, ECG, skin temperature, RR, body posture Wi-Fi, 3G, 4G (Master Caution®) On the outer surface above the left side of the waist [87]”
Background
Metadata
- Authors
- Angelucci, A., Cavicchioli, M., Cintorrino, I., Lauricella, G., Rossi, C., Strati, S., & Aliverti, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-01-26
- Volume
- 21
- Issue
- 3
- Pages
- 814
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3122925590
- Cited by
- 170
- References
- 74
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.