Validity of the Polar H7 Heart Rate Sensor for Heart Rate Variability Analysis during Exercise in Different Age, Body Composition and Fitness Level Groups
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 2×
“CCC determines how much the observed data deviate from the perfect concordance line at 45° on a square axis scatter plot [33].”
BackgroundAn overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775
Heart rate variability: measurement and clinical utility.
Kleiger, R. E., Stein, P. K., & Bigger, J. T. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.10101.x · Cited by 1,290
Spallone, V., Ziegler, D., Freeman, R., Bernardi, L., Frontoni, S., Pop‐Busui, R., Stevens, M., Kempler, P., Hilsted, J., Tesfaye, S., et al. (2011) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.1239 · Cited by 957
Submaximal Exercise Testing: Clinical Application and Interpretation
Noonan, V., & Dean, E. (2000) · Physical Therapy · doi:10.1093/ptj/80.8.782 · Cited by 637
RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise
Gilgen-Ammann, R., Schweizer, T., & Wyss, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04142-5 · Cited by 438 · cited 4×
“It should be noted, however, that a reduced set of ten healthy, lean and physically fit volunteers was considered in [12], whereas here we investigated a larger set of volunteers with a broader range of ages, body compositions and fitness levels.”
BackgroundMethodResultInfluentialBilchick, K. C., Fetics, B., Djoukeng, R., Gross Fisher, S., Fletcher, R. D., Singh, S. N., Nevo, E., & Berger, R. D. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02380-9 · Cited by 288
Cited by
Schaffarczyk, M., Rogers, B., Reer, R., & Gronwald, T. (2022) · Sensors · doi:10.3390/s22176536 · Cited by 349
Rogers, B., Schaffarczyk, M., Clauß, M., Mourot, L., & Gronwald, T. (2022) · Sensors · doi:10.3390/s22052032 · Cited by 41
Östh, S., Helge, T., & Ekblom-Bak, E. (2025) · Sport Sciences for Health · doi:10.1007/s11332-025-01396-9 · Cited by 2
“Heart rate was recorded using a Polar H7 heart rate sensor attached to a Polar H7 Chest soft strap to minimize motion artifacts [18].”
Metadata
- Authors
- Hernández-Vicente, A., Hernando, D., Marín-Puyalto, J., Vicente-Rodríguez, G., Garatachea, N., Pueyo, E., & Bailón, R.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-01-29
- Volume
- 21
- Issue
- 3
- Pages
- 902
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3127764261
- Cited by
- 57
- References
- 12
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.