Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index; 22 of the 35 sources its claims cite were checked for support.
Abstract
The squat is a critical component of numerous rehabilitation and functional assessment protocols, playing a significant role in enhancing athletic performance and activities of daily living. Although some of the characteristics gathered during the squat need additional confirmation, Kinovea provides a free two-dimensional squat motion analysis tool that is simple to use in clinical practice. This analytical, cross-sectional reliability study aimed to evaluate the intra-rater and test–retest reliability (with a 20 min interval between performances) of loaded squat kinematics in a sample of women using Kinovea. Twenty women performed a loaded back squat; intra-rater reliability was assessed by re-analyzing the same video one week apart, and test–retest reliability was assessed across two performances separated by 20 min. The results showed good to excellent intra-rater reliability (ICC: 0.75–0.99; SEM: 0.16 cm to 5.14°; MDC: 0.44 cm to 14.24°), and moderate to excellent test–retest reliability (ICC: 0.64–0.98; SEM: 0.36 cm to 14.29°; MDC: 0.99 cm to 39.61°). Variables tracked in the sagittal plane showed high precision. Conversely, the head angle and knee angle in the frontal plane exhibited greater variability, reflected by higher SEM and MDC values. In conclusion, Kinovea is a reliable and accessible tool for clinical kinematic assessment of the squat, particularly in the sagittal plane parameters. However, due to the elevated measurement error observed in head angles and frontal-plane knee dynamics, the integration of 3D motion capture is recommended over 2D digital protocols for these variables.
Overview
CoChat Summary
## TL;DR
This analytical cross-sectional reliability study found that Kinovea 2D photogrammetry had good to excellent intra-rater reliability and moderate to excellent test–retest reliability for loaded squat kinematics in 20 healthy active women. Reliability was strongest for sagittal-plane variables, while head angle and frontal-plane knee measures showed larger errors and lower clinical sensitivity.
## Key findings
- The sample included 20 women (mean age 37.75 ± 15.47 years, range 20–71; mean BMI 25.10 ± 5.09, range 19.94–33.79).
- Intra-rater reliability was good to excellent, with ICC values from 0.75 to 0.99; the highest reliability was for trunk forward tilt (P1) and medial-lateral knee deviation (P2), both ICC = 0.99.
- Test–retest reliability ranged from moderate to excellent, with ICC values from 0.64 to 0.98; the highest reliability was knee flexion (P2), ICC = 0.98, and the lowest was horizontal pelvic alignment in the frontal plane (P2), ICC = 0.64.
- Absolute reliability was stronger for sagittal-plane variables than for head and frontal-plane knee variables: reported SEM/MDC for intra-rater reliability ranged from 0.16 cm to 5.14° and 0.44 cm to 14.24°, while test–retest values ranged from 0.36 cm to 14.29° and 0.99 cm to 39.61°.
## Methods
- Design: Analytical observational, cross-sectional reliability study conducted at a sport center; the paper assessed intra-rater and test–retest reliability.
- Sample/data: 20 recreational back-squat lifters, all female, age over 18, with exclusions for recent musculoskeletal injury, surgery, orthotic devices, or discomfort/marker interference.
- Analysis: Squat kinematics were recorded with Kinovea 2023.1.1 using two Logitech C920S HD Pro cameras at 30 fps; reliability was evaluated with ICC (3,1), plus SEM, MDC, and Bland–Altman plots. Two performances were separated by 20 min, and the same video was reanalyzed one week apart for intra-rater reliability.
## Limitations
- The paper states that soft tissue artifacts can limit accuracy, especially in participants with higher BMIs.
- The paper states that the wide age range (20–71 years) and modest sample size introduced biomechanical heterogeneity.
- The paper states that menstrual cycle phase was not recorded.
- Evident from the text: this was a small, all-female, single-center sample of recreational lifters, so generalizability beyond this group is limited.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
12 Valid · 2 Not valid · 9 Not checked · 96 Own results and interpretations
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“Assuming values for type I and type II errors of α = 0.05 and β = 0.20, respectively, a minimum acceptable ICC of 0.70 and an expected ICC of 0.90, it was estimated that 18.4 subjects were required.”
§ Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women > 2. Materials and Methods > 2.3. Sample Size Calculation
What the sources say
- Partly supportedcites [31] Vicente-Pina, L., Sánchez-Rodríguez, R., Ferrández-Laliena, L., Heredia-Jimenez, J., Müller-Thyssen-Uriarte, J., Monti-Ballano, S., Hidalgo-García, C., Tricás-Moreno, J.M., and Lucha-López, M.O. (2025). Validity and Reliability of Kinovea® for Pelvic Kinematic Measurement in Standing Position and in Sitting Position with 45° of Hip Flexion. Sensors, 25. sourceExperimental — accuracy not yet measured
The Sample Size Calculation section (2.6) uses α = 0.05 and power = 0.80, equivalent to β = 0.20. But it reports 13 required subjects, an expected ICC of 0.88, and a null-hypothesis ICC of 0.5—not 18.4 subjects or ICC values of 0.90 and 0.70. (LLM, conf=0.90)
- Disputedcites [32] Fernández-González, P., Koutsou, A., Cuesta-Gómez, A., Carratalá-Tejada, M., Miangolarra-Page, J.C., and Molina-Rueda, F. (2020). Reliability of Kinovea® Software and Agreement with a Three-Dimensional Motion System for Gait Analysis in Healthy Subjects. Sensors, 20. sourceExperimental — accuracy not yet measured
The Sample Size Calculation section (2.6) gives a minimum acceptable ICC of 0.6, an expected ICC of 0.8, and a required sample of 43—not 0.70, 0.90, and 18.4. It does not give the claimed α and β values for that calculation. (LLM, conf=0.92)
Checked by a reasoning model — may be wrong.
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“previous literature evaluating sagittal plane kinematics with Kinovea, which uniformly reports robust reliability coefficients (ICC > 0.80) for hip, knee, and ankle angles [32], pelvic alignment [31], lumbar lordosis [46,47], and trunk tilt [48].”
§ Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women > 4. Discussion
What the sources say
- Supportedcites [32] Fernández-González, P., Koutsou, A., Cuesta-Gómez, A., Carratalá-Tejada, M., Miangolarra-Page, J.C., and Molina-Rueda, F. (2020). Reliability of Kinovea® Software and Agreement with a Three-Dimensional Motion System for Gait Analysis in Healthy Subjects. Sensors, 20. source
This source is cited for hip, knee, and ankle angles, not the separately cited pelvic alignment, lumbar lordosis, or trunk tilt. Its Results (section 3) report intra-rater ICC > 0.85 and inter-rater ICC > 0.90 for all three joints in healthy subjects during initial contact of walking, supporting the attributed ICC > 0.80 claim. (LLM, conf=0.93)
- Supportedcites [31] Vicente-Pina, L., Sánchez-Rodríguez, R., Ferrández-Laliena, L., Heredia-Jimenez, J., Müller-Thyssen-Uriarte, J., Monti-Ballano, S., Hidalgo-García, C., Tricás-Moreno, J.M., and Lucha-López, M.O. (2025). Validity and Reliability of Kinovea® for Pelvic Kinematic Measurement in Standing Position and in Sitting Position with 45° of Hip Flexion. Sensors, 25. source
Citation [31] is attached to pelvic alignment, not to the other angles listed in the sentence. The Discussion reports good-to-excellent Kinovea reliability for pelvic-tilt measurements, including a lowest noted inter-examiner ICC of 0.88 for left-side posterior pelvic tilt while sitting. This supports the attributed ICC > 0.80 for pelvic alignment. (LLM, conf=0.91)
- Not checked — no full text of the sourcecites [46] Mier, 2013, Reliability of a Computer Software Angle Tool for Measuring Spine and Pelvic Flexibility during the Sit-and-Reach Test, J. Strength Cond. Res. source
- Disputedcites [47] Yodchaisarn, 2023, Inter-Rater and Test-Retest Reliabilities of Lumbar Stiffness Measurement in the Postero-Anterior Direction Using a Portable Algometer and the Kinovea Program, PeerJ sourceExperimental — accuracy not yet measured
The Abstract’s Methods describe Kinovea measurements of postero-anterior lumbar displacement and stiffness, not sagittal-plane angles or lumbar lordosis. The Abstract’s Results report ICC ranges beginning at 0.51–0.67, contrary to the claim that this source uniformly reports ICCs above 0.80. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“positioning the head near the edges of the camera’s field of view may have increased errors due to parallax or spherical lens distortion compared to the segments located closer to the center of the frame (e.g., pelvis and knee) [48,57].”
§ Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women > 4. Discussion
What the sources say
- Could not verifycites [48] Puig-Diví, A., Escalona-Marfil, C., Padullés-Riu, J.M., Busquets, A., Padullés-Chando, X., and Marcos-Ruiz, D. (2019). Validity and Reliability of the Kinovea Program in Obtaining Angles and Distances Using Coordinates in 4 Perspectives. PLoS ONE, 14. sourceExperimental — accuracy not yet measured
The Results (Data analysis; page not provided) compare measurement error across camera perspectives, not across positions within the frame. Searches for parallax, lens distortion, and edge-versus-center placement found no passage addressing whether a head near the frame edge would have greater error than a pelvis or knee near its center. (LLM, conf=0.74)
- Partly supportedcites [57] Shishov, N., Elabd, K., Komisar, V., Chong, H., and Robinovitch, S.N. (2021). Accuracy of Kinovea Software in Estimating Body Segment Movements during Falls Captured on Standard Video: Effects of Fall Direction, Camera Perspective and Video Calibration Technique. PLoS ONE, 16. sourceExperimental — accuracy not yet measured
The Discussion (page not available in our copy) says uncorrected camera lens distortion may have affected measurements, particularly for body parts at the edges of the video image. It does not specifically identify the head, compare it with the pelvis or knee near the frame center, or name parallax or spherical lens distortion as the cause. (LLM, conf=0.84)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“Soylu et al. [58], who, when comparing Kinovea with the D-Wall system in the overhead squat, obtained ICCs in the sagittal plane ranging from 0.79 to 0.99.”
§ Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women > 4. Discussion
What the sources say
- Supportedcites [58] Soylu, C., Acar, G., Uzumcu, B., Demir, P., Seyhan, S., and Biyikli, T. (2025). Test-Retest Reliability and Validity of TecnoBody D-Wall to Assess the Range of Motion During Overhead Squat in Healthy Individuals. Life, 15. source
The Abstract states that the study measured hip and knee angles in the sagittal plane during overhead squats using Kinovea and D-Wall, and reports ICCs ranging from 0.79 to 0.99. The Discussion likewise gives that range for the systems’ ROM measurements. (LLM, conf=0.93)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“SEM and MDC values obtained for horizontal pelvic alignment from a sagittal plane at P1 (SEM = 1.10°; MDC = 3.05°) were only slightly higher than those reported by Vicente–Pina [31] in bipedal position (SEM = 0.9°; MDC = 2.6°).”
§ Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women > 4. Discussion
What the sources say
- Partly supportedcites [31] Vicente-Pina, L., Sánchez-Rodríguez, R., Ferrández-Laliena, L., Heredia-Jimenez, J., Müller-Thyssen-Uriarte, J., Monti-Ballano, S., Hidalgo-García, C., Tricás-Moreno, J.M., and Lucha-López, M.O. (2025). Validity and Reliability of Kinovea® for Pelvic Kinematic Measurement in Standing Position and in Sitting Position with 45° of Hip Flexion. Sensors, 25. sourceExperimental — accuracy not yet measured
The Methods (§2.5 and §2.7; page unavailable) describe sagittal pelvic measurements against a horizontal reference and calculation of SEM and MDC, including for standing measurements. The retrieved Results (§3; page unavailable) discuss standing-position reliability but do not give the attributed SEM of 0.9° or MDC of 2.6°, so those figures cannot be verified from the passages available in our copy. (LLM, conf=0.76)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
55 more claims · 1 with their cited sources checked
Create a free account to see all 119 claims and to verify the 2 references still open.
- Probably not a substantial claim. 27
- It may state two separate claims as one. 39
- The quote only partly states this claim. 3
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Elliott-Sale, K. J., Minahan, C. L., de Jonge, X. A. K. J., Ackerman, K. E., Sipilä, S., Constantini, N. W., Lebrun, C. M., & Hackney, A. C. (2021) · Sports Medicine · doi:10.1007/s40279-021-01435-8 · Cited by 731
Knee biomechanics of the dynamic squat exercise
ESCAMILLA, R. F. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200101000-00020 · Cited by 570 · cited 2×
“The squat is regarded as one of the most efficacious workouts for enhancing athletic performance, as it necessitates the coordination of substantial muscle groups engaged in activities such as jumping, running, or weightlifting [1].”
Squatting Kinematics and Kinetics and Their Application to Exercise Performance
Schoenfeld, B. J. (2010) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181bac2d7 · Cited by 545 · cited 1×
“The ability of the central nervous system to precisely and effectively coordinate and adjust the activation of various muscle groups and joint segments during a workout is referred to as a motor control [6–8].”
Puig-Diví, A., Escalona-Marfil, C., Padullés-Riu, J. M., Busquets, A., Padullés-Chando, X., & Marcos-Ruiz, D. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216448 · Cited by 434 · cited 2×
“Furthermore, positioning the head near the edges of the camera’s field of view may have increased errors due to parallax or spherical lens distortion compared to the segments located closer to the center of the frame (e.g., pelvis and knee) [48,57].”
InfluentialTechniques in the Evaluation and Treatment of the Injured Runner
Brody, D. M. (1982) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)30252-2 · Cited by 372
Myer, G. D., Kushner, A. M., Brent, J. L., Schoenfeld, B. J., Hugentobler, J., Lloyd, R. S., Vermeil, A., Chu, D. A., Harbin, J., & McGill, S. M. (2014) · Strength & Conditioning Journal · doi:10.1519/ssc.0000000000000103 · Cited by 242
Postural aberrations in low back pain
Christie, H. J., Kumar, S., & Warren, S. A. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80604-0 · Cited by 195
Mehta, S., Bastero‐Caballero, R. F., Sun, Y., Zhu, R., Murphy, D. K., Hardas, B., & Koch, G. (2018) · Statistics in Medicine · doi:10.1002/sim.7679 · Cited by 193 · cited 1×
“Despite this non-normality in specific parameters, the parametric approach was maintained because the intraclass correlation coefficient (ICC) is robust to mild violations of normality [44].”
The accuracy of several pose estimation methods for 3D joint centre localisation
Needham, L., Evans, M., Cosker, D. P., Wade, L., McGuigan, P. M., Bilzon, J. L., & Colyer, S. L. (2021) · Scientific Reports · doi:10.1038/s41598-021-00212-x · Cited by 190
Research works printed but not linked: 3
- Arango, 2007, Lesiones Deportivas, Iatreia, 20, 167
- Kingston, 2021, Lower Limb Movement Pattern Differences Between Males and Females in Squatting and Kneeling, J. Appl. Biomech., 37, 204
- Schurr, 2017, Two-dimensional video analysis is comparable to 3d motion capture in lower extremity movement assessment, Int. J. Sports Phys. Ther., 12, 163
Cited by
Doosti, M., Boroujeni, S. T., & Araghi, E. S. (2026) · Acta Psychologica · doi:10.1016/j.actpsy.2026.108080
Metadata
- Authors
- Vicente-Loren, C., Lucha-López, M. O., Monti-Ballano, S., Hijazo-Larrosa, S., Vicente-Pina, L., Ferrández-Laliena, L., Tricás-Moreno, J. M., & Hidalgo-García, C.
- Affiliations
- O2 Centro Wellness Boutique Gym, Don Ramón de la Cruz, 28001 Madrid, Spain
- Universidad de Zaragoza (ES)
- Corresponding author
- Vicente-Loren, Concepción
- Lucha-López, María Orosia
- ORCID
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2026-06-12
- Volume
- 26
- Issue
- 12
- Pages
- 3749
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC13306374
- OpenAlex
- W7164565057
- Cited by
- 0
- References
- 58
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- Zaguan (University of Zaragoza Repository) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- UNIDAD DE INVESTIGACIÓN EN FISIOTERAPIA
- Gobierno de Aragón (B38_23R)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- squatting, squat kinematics, Kinovea, video-based motion analysis, two-dimensional motion analysis, intra-rater reliability, test-retest reliability, measurement error, sagittal plane, frontal plane, knee joint angle, head angle, women, 3D motion capture
- MeSH terms
- Motion Capture, Adult, Biomechanical Phenomena, Cross-Sectional Studies, Female, Humans, Reproducibility of Results, Range of Motion, Articular, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.