Hierarchical Hydrogels with Ordered Micro-Nano Structures for Cancer-on-a-Chip Construction
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
In the drug therapy of tumor, efficient and stable drug screening platforms are required since the drug efficacy varies individually. Here, inspired by the microstructures of hepatic lobules, in which hepatocytes obtain nutrients from both capillary vessel and the central vein, we present a novel hierarchical hydrogel system with ordered micro-nano structure for liver cancer-on-a-chip construction and drug screening. The hierarchical hydrogel system was fabricated by using pregel to fill and replicate self-assembled colloidal crystal arrays and microcolumn array template. Due to the synergistic effect of its interconnected micro-nano structures, the resultant system could not only precisely control the size of cell spheroids but also realize adequate nutrient supply of cell spheroids. We have demonstrated that by integrating the hierarchical hydrogel system into a multichannel concentration gradients microfluidic chip, a functional liver cancer-on-a-chip could be constructed for high-throughput drug screening with good repeatability and high accuracy. These results indicated that the hierarchical hydrogel system and its derived liver cancer-on-a-chip are ideal platforms for drug screening and have great application potential in the field of personalized medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This architecture yielded uniformly sized tumor spheroids with superior viability, providing a robust scaffold for anti-cancer drug screening [231].”
From Constructing biomimetic microenvironments for liver regeneration (2025) · doi:10.1186/s12951-025-03729-9 · cites this paper as [231]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor exosome-based nanoparticles are efficient drug carriers for chemotherapy
Yong, T., Zhang, X., Bie, N., Zhang, H., Zhang, X., Li, F., Hakeem, A., Hu, J., Gan, L., Santos, H. A., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11718-4 · Cited by 806 · cited 1×
“them, drug therapy is the main approach due to its simplicity and convenience [4-6].”
BackgroundPark, T.-E., Mustafaoglu, N., Herland, A., Hasselkus, R., Mannix, R., FitzGerald, E. A., Prantil-Baun, R., Watters, A., Henry, O., Benz, M., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10588-0 · Cited by 594 · cited 2×
“the organ-on-a-chip can accurately control biochemical factors, mechanical stress and other parameters, thereby simulating the smallest functional unit of human organs in vitro [23, 37].”
BackgroundReproducing human and cross-species drug toxicities using a liver-chip
Jang, K.-J., Otieno, M. A., Ronxhi, J., Lim, H.-K., Ewart, L., Kodella, K. R., Petropolis, D. B., Kulkarni, G., Rubins, J. E., Conegliano, D., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aax5516 · Cited by 511 · cited 1×
“As a bionic technology, the organ-on-a-chip can accurately control biochemical factors, mechanical stress, and other parameters, thereby simulating the smallest functional unit of human organs in vitro [23, 37].”
BackgroundHerland, A., Maoz, B. M., Das, D., Somayaji, M. R., Prantil-Baun, R., Novak, R., Cronce, M., Huffstater, T., Jeanty, S. S. F., Ingram, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0498-9 · Cited by 500 · cited 2×
“In addition, the organ-on-a-chip also has the characteristics of low loss, high throughput, and integration, so it is regarded as a bionic, energy-saving, and efficient platform that can be used for physiology research and drug development [24, 26].”
BackgroundEGFR activation limits the response of liver cancer to lenvatinib
Jin, H., Shi, Y., Lv, Y., Yuan, S., Ramirez, C. F. A., Lieftink, C., Wang, L., Wang, S., Wang, C., Dias, M. H., et al. (2021) · Nature · doi:10.1038/s41586-021-03741-7 · Cited by 440 · cited 1×
“In clinical practice, numerous therapeutic methods such as surgical resection, drug therapy, chemotherapy and radiotherapy have been adopted [1-3].”
BackgroundInducing and exploiting vulnerabilities for the treatment of liver cancer
Wang, C., Vegna, S., Jin, H., Benedict, B., Lieftink, C., Ramirez, C., de Oliveira, R. L., Morris, B., Gadiot, J., Wang, W., et al. (2019) · Nature · doi:10.1038/s41586-019-1607-3 · Cited by 427 · cited 1×
“However, the efficacy of these drugs varies individually in the patients with advanced stage of liver cancer because of the tumor heterogeneity [7-9].”
BackgroundHyaluronic acid and its biomedical applications: A review
Dovedytis, M., Liu, Z. J., & Bartlett, S. (2020) · Engineered Regeneration · doi:10.1016/j.engreg.2020.10.001 · Cited by 413 · cited 1×
“Since the hydrogel system precisely mimics the natural extracellular matrix (ECM) environment, cells embedded in the hydrogel will produce endogenous ECM proteins and continue to aggregate to form cell spheroids [13-15].”
BackgroundBiomedical applications of gelatin methacryloyl hydrogels
Piao, Y., You, H., Xu, T., Bei, H.-P., Piwko, I. Z., Kwan, Y. Y., & Zhao, X. (2021) · Engineered Regeneration · doi:10.1016/j.engreg.2021.03.002 · Cited by 295 · cited 1×
“Since the hydrogel system precisely mimics the natural extracellular matrix (ECM) environment, cells embedded in the hydrogel will produce endogenous ECM proteins and continue to aggregate to form cell spheroids [13-15].”
BackgroundLiver homeostasis is maintained by midlobular zone 2 hepatocytes
Wei, Y., Wang, Y. G., Jia, Y., Li, L., Yoon, J., Zhang, S., Wang, Z., Zhang, Y., Zhu, M., Sharma, T., et al. (2021) · Science · doi:10.1126/science.abb1625 · Cited by 292 · cited 1×
“It is well known that the fundamental structural and functional unit of the liver is the polyhedral and prismatic hepatic lobule [16, 17]; in the center of that, a longitudinal central vein is distributed in which the hepatocytes arrange radially to form the hepatic plate.”
BackgroundProliferation tracing reveals regional hepatocyte generation in liver homeostasis and repair
He, L., Pu, W., Liu, X., Zhang, Z., Han, M., Li, Y., Huang, X., Han, X., Li, Y., Liu, K., et al. (2021) · Science · doi:10.1126/science.abc4346 · Cited by 261 · cited 1×
“It is well known that the fundamental structural and functional unit of the liver is the polyhedral and prismatic hepatic lobule [16, 17]; in the center of that, a longitudinal central vein is distributed in which the hepatocytes arrange radially to form the hepatic plate.”
Background
Cited by
The horizon of bone organoid: A perspective on construction and application
Chen, S., Chen, X., Geng, Z., & Su, J. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.01.048 · Cited by 195
From Organ-on-a-Chip to Human-on-a-Chip: A Review of Research Progress and Latest Applications
Huang, Y., Liu, T., Huang, Q., & Wang, Y. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00004 · Cited by 109
Wang, Y., Jiang, X., Li, X., Ding, K., Liu, X., Huang, B., Ding, J., Qu, K., Sun, W., Xue, Z., et al. (2023) · Materials Horizons · doi:10.1039/d3mh00326d · Cited by 98
Recent Advances of Organ-on-a-Chip in Cancer Modeling Research
Liu, X., Su, Q., Zhang, X., Yang, W., Ning, J., Jia, K., Xin, J., Li, H., Yu, L., Liao, Y., et al. (2022) · Biosensors · doi:10.3390/bios12111045 · Cited by 75
Liu, X., Zhou, S., Cai, B., Wang, Y., Deng, D., & Wang, X. (2022) · Biomaterials Science · doi:10.1039/d2bm00224h · Cited by 60
Metadata
- Authors
- Zhu, L., Shao, C., Chen, H., Chen, Z., & Zhao, Y.
- Affiliations
- Nanjing Drum Tower Hospital (CN)
- State Key Laboratory of Digital Medical Engineering (CN)
- Corresponding author
- Zhao, Yuanjin
- Venue
- Research
- Published
- 2021-01
- Volume
- 2021
- Pages
- 9845679-9845679
- ISSN
- 2639-5274 (ISSN-L)
- PMC
- PMC8724685
- OpenAlex
- W4200036397
- Cited by
- 41
- References
- 40
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 10 · 2023: 12 · 2022: 12
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Research (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Strategic Priority Research Program of the Chinese Academy of Science (XDA16021103)
- Shenzhen Fundamental Research Program (JCYJ20190813152616459)
- National Natural Science Foundation of China (61927805, 52073060)
- National Key Research and Development Program of China (2020YFA0908200)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- drug screening, hepatocellular carcinoma, micro/nanostructures, cell spheroids, nutrient supply, microfluidics, concentration gradient, personalized medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.