Longitudinal Ramsey spectroscopy of atoms for continuous operation of optical clocks
Open accessThe DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
We propose a longitudinal Ramsey spectroscopy of atoms in a moving optical lattice. Spatially separated magnetic fields, which open the forbidden 1 S 0 − 3 P 0 transition by mixing with the dipole-allowed states, create Ramsey pulses for a probe laser introduced along the optical lattice. Excitation of atoms in the Lamb-Dicke regime by a single probe laser avoids residual Doppler effects as well as mechanical instabilities that deteriorate Ramsey spectroscopy on an atomic beam. Continuous measurement and control of the probe laser improves the Allan deviation as τ −1 for an averaging time τ until the quantum projection noise limit is reached. For 88 Sr atoms with an atomic flux of 10 4 s −1 , we speculate a clock instability of 5 × 10 −16 ( τ s −1 ) −1 down to its floor at around 10 −18 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The main contribution is Dick noise [61] of the transportable clock laser [56].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [56]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The instability is slightly higher in the remote clock comparison (1 . 7 × 10 -15 / √ τ/ s, Fig. 4) than in the local one (1 . 0 × 10 -15 / √ τ/ s, Fig. 2) as the transportable clock laser [56] was pre-stabilized to the ultrastable lasers at PTB [57, 58] during the local comparisons.”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [56]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
A Molecular Beam Resonance Method with Separated Oscillating Fields
Ramsey, N. F. (1950) · Physical Review · doi:10.1103/physrev.78.695 · Cited by 1,045
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Quantum Logic Gates in Optical Lattices
Brennen, G. K., Caves, C. M., Jessen, P. S., & Deutsch, I. H. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.1060 · Cited by 665
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Self-citationQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Self-citationOptical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer
Riehle, F., Kisters, T., Witte, A., Helmcke, J., & Bordé, C. J. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.177 · Cited by 541
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Self-citationDemonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Ultralow noise miniature external cavity semiconductor laser
Liang, W., Ilchenko, V. S., Eliyahu, D., Savchenkov, A. A., Matsko, A. B., Seidel, D., & Maleki, L. (2015) · Nature Communications · doi:10.1038/ncomms8371 · Cited by 398
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Monoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Santarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Optical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 275
Taichenachev, A., Yudin, V., Oates, C., Hoyt, C., Barber, Z., & Hollberg, L. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.083001 · Cited by 266
Kennedy, C. J., Oelker, E., Robinson, J. M., Bothwell, T., Kedar, D., Milner, W. R., Marti, G. E., Derevianko, A., & Ye, J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.201302 · Cited by 219
Microscopic Control and Detection of Ultracold Strontium in Optical-Tweezer Arrays
Norcia, M. A., Young, A. W., & Kaufman, A. M. (2018) · Physical Review X · doi:10.1103/physrevx.8.041054 · Cited by 207
LOCAL OSCILLATOR INDUCED INSTABILITIES IN TRAPPED ION FREQUENCY STANDARDS
Dick, G. J. (1987) · Cited by 193
Optical lattice clocks with non-interacting bosons and fermions
Akatsuka, T., Takamoto, M., & Katori, H. (2008) · Nature Physics · doi:10.1038/nphys1108 · Cited by 166
Self-citationFrequency Measurements of Superradiance from the Strontium Clock Transition
Norcia, M. A., Cline, J. R. K., Muniz, J. A., Robinson, J. M., Hutson, R. B., Goban, A., Marti, G. E., Ye, J., & Thompson, J. K. (2018) · Physical Review X · doi:10.1103/physrevx.8.021036 · Cited by 139
Prospects for using laser-prepared atomic fountains for optical frequency standards applications
Hall, J. L., Zhu, M., & Buch, P. (1989) · Journal of the Optical Society of America B · doi:10.1364/josab.6.002194 · Cited by 130
Nondestructive measurement of the transition probability in a Sr optical lattice clock
Lodewyck, J., Westergaard, P. G., & Lemonde, P. (2009) · Physical Review A · doi:10.1103/physreva.79.061401 · Cited by 108
Optical clock intercomparison with $6\times 10^{-19}$ precision in one hour
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1902.02741 · Cited by 98
Local oscillator induced degradation of medium-term stability in passive atomic frequency standards
Dick, G. J., Prestage, J. D., Greenhall, C. A., & Maleki, L. (1990) · Cited by 80
Strategies for reducing the light shift in atomic clocks
Katori, H., Ovsiannikov, V. D., Marmo, S. I., & Palchikov, V. G. (2015) · Physical Review A · doi:10.1103/physreva.91.052503 · Cited by 74
Self-citationZero-Dead-Time Operation of Interleaved Atomic Clocks
Biedermann, G. W., Takase, K., Wu, X., Deslauriers, L., Roy, S., & Kasevich, M. A. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.170802 · Cited by 70
Olson, J., Fox, R. W., Fortier, T. M., Sheerin, T. F., Brown, R. C., Leopardi, H., Stoner, R. E., Oates, C. W., & Ludlow, A. D. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.073202 · Cited by 70
Laser-Frequency Stabilization Based on Steady-State Spectral-Hole Burning inEu3+∶Y2SiO5
Cook, S., Rosenband, T., & Leibrandt, D. R. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.253902 · Cited by 60
Compact, thermal-noise-limited reference cavity for ultra-low-noise microwave generation
Davila-Rodriguez, J., Baynes, F. N., Ludlow, A. D., Fortier, T. M., Leopardi, H., Diddams, S. A., & Quinlan, F. (2017) · Optics Letters · doi:10.1364/ol.42.001277 · Cited by 57
Ground-based optical atomic clocks as a tool to monitor vertical surface motion
Bondarescu, R., Schärer, A., Lundgren, A., Hetényi, G., Houlié, N., Jetzer, P., & Bondarescu, M. (2015) · Geophysical Journal International · doi:10.1093/gji/ggv246 · Cited by 56
Continuous Guided Strontium Beam with High Phase-Space Density
Chen, C.-C., Bennetts, S., Escudero, R. G., Pasquiou, B., & Schreck, F. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.044014 · Cited by 49
Improving the Q Factor of an Optical Atomic Clock Using Quantum Nondemolition Measurement
Bowden, W., Vianello, A., Hill, I. R., Schioppo, M., & Hobson, R. (2020) · Physical Review X · doi:10.1103/physrevx.10.041052 · Cited by 40
Takano, T., Mizushima, R., & Katori, H. (2017) · Applied Physics Express · doi:10.7567/apex.10.072801 · Cited by 35
Self-citationSuperradiance from lattice-confined atoms inside hollow core fibre
Okaba, S., Yu, D., Vincetti, L., Benabid, F., & Katori, H. (2019) · Communications Physics · doi:10.1038/s42005-019-0237-2 · Cited by 33
Self-citationFrequency stability of optical lattice clocks
Lodewyck, J., Westergaard, P. G., Lecallier, A., Lorini, L., & Lemonde, P. (2010) · New Journal of Physics · doi:10.1088/1367-2630/12/6/065026 · Cited by 31
Dynamical decoupling of laser phase noise in compound atomic clocks
Dörscher, S., Al-Masoudi, A., Bober, M., Schwarz, R., Hobson, R., Sterr, U., & Lisdat, C. (2020) · Communications Physics · doi:10.1038/s42005-020-00452-9 · Cited by 31
Three-stage laser cooling of Sr atoms using the 5s5pP23 metastable state below Doppler temperatures
Akatsuka, T., Hashiguchi, K., TAKAHASHI, T., Ohmae, N., Takamoto, M., & Katori, H. (2021) · Physical Review A · doi:10.1103/physreva.103.023331 · Cited by 22
Self-citationLongitudinal ramsey-fringe spectroscopy in a calcium beam
Snyder, J. J., Helmcke, J., & Zevgolis, D. (1983) · Applied Physics B · doi:10.1007/bf00688771 · Cited by 15
Hall, J. L. (1976) · Optics Communications · doi:10.1016/0030-4018(76)90536-8 · Cited by 9
Dick, G. J., & Stowers, D. A. (2002) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.1995.483899 · Cited by 2
Improving the Q factor of an optical atomic clock using quantum non-demolition measurementPreprint
Bowden, W., Vianello, A., Hill, I. R., Schioppo, M., & Hobson, R. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2010.10419 · Cited by 1
Cited by
A perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40
Self-citationLong-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“Consequently, it offers an attractive way to resolve existing discrepancies (at the centimeter to decimeter level) between the established geodetic methods, overcome their limitations, improve continental and global height reference frames, connect island and mainland height systems, connect tide gauges for sea level…”
InfluentialExploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
“2016; Katori 2021), which improves clocks’ stability as −1 , will be used to access low 10−19 uncertainty in an averaging time of less than an hour (dashed-green line).”
BackgroundSelf-citationQuantum enhanced time synchronisation for communication network
Nande, S. S., Paul, M., Senk, S., Ulbricht, M., Bassoli, R., Fitzek, F. H. P., & Boche, H. (2023) · Computer Networks · doi:10.1016/j.comnet.2023.109772 · Cited by 30
“These phase oscillations are fundamental and can provide us time using a protocol like Ramsey interferometry [12].”
MethodSubnatural Linewidth Superradiant Lasing with Cold Sr 88 Atoms
Kristensen, S. L., Bohr, E. A., Robinson-Tait, J., Zelevinsky, T., Thomsen, J. W., & Müller, J. H. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.223402 · Cited by 41
Metadata
- Authors
- Katori, H.
- Affiliations
- RIKEN (JP)
- Corresponding author
- Katori, Hidetoshi
- ORCID
- Katori, Hidetoshi
- Venue
- Applied Physics Express
- Publisher
- IOP Publishing
- Published
- 2021-07-01
- Volume
- 14
- Issue
- 7
- Pages
- 072006
- ISSN
- 1882-0778 (ISSN-L)
- 1882-0786
- OpenAlex
- W3174162694
- Cited by
- 31
- References
- 47
- Citations by year
- 2026: 2 · 2025: 7 · 2024: 7 · 2023: 8 · 2022: 5 · 2021: 2
- FWCI
- 2.40
- Type
- journal article
- Language
- lv
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor, 4 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 4 d)
- Locations
- Applied Physics Express (publishedVersion, cc-by)
- Funders
- Japan Science and Technology Agency (JPMJMI18A1)
- Japan Society for the Promotion of Science (JP16H06284)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- optical atomic clocks, moving optical lattice, 88Sr, 1S0-3P0 transition, Lamb-Dicke regime, Allan deviation, quantum projection noise, clock instability, Doppler-free spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.