Establishing a Physiologic Human Vascularized Micro-Tumor Model for Cancer Research
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, this model has been used to demonstrate the extravasation of T cells, underlining its potential in assessing tumor-stromal, tumor-immune and immune-stromal interactions (Hachey et al., 2023a).”
From Microphysiological systems as models for immunologically ‘cold’ tumors (2024) · cites this paper as Hachey et al., 2023a
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
3D microtumors in vitro supported by perfused vascular networks
Sobrino, A., Phan, D. T. T., Datta, R., Wang, X., Hachey, S. J., Romero-López, M., Gratton, E., Lee, A. P., George, S. C., & Hughes, C. C. W. (2016) · Scientific Reports · doi:10.1038/srep31589 · Cited by 387
Self-citationIn Vitro Perfused Human Capillary Networks
Moya, M. L., Hsu, Y.-H., Lee, A. P., Hughes, C. C. W., & George, S. C. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0430 · Cited by 387
Self-citationA vascularized and perfused organ-on-a-chip platform for large-scale drug screening applications
Phan, D. T. T., Wang, X., Craver, B. M., Sobrino, A., Zhao, D., Chen, J. C., Lee, L. Y. N., George, S. C., Lee, A. P., & Hughes, C. C. W. (2017) · Lab on a Chip · doi:10.1039/c6lc01422d · Cited by 325
Self-citationVascularized microfluidic organ-chips for drug screening, disease models and tissue engineering
Osaki, T., Sivathanu, V., & Kamm, R. D. (2018) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2018.03.011 · Cited by 141
Applications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
Self-citationRomero-López, M., Trinh, A. L., Sobrino, A., Hatch, M. M. S., Keating, M. T., Fimbres, C., Lewis, D. E., Gershon, P. D., Botvinick, E. L., Digman, M., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.11.034 · Cited by 125
Self-citationHachey, S. J., Movsesyan, S., Nguyen, Q. H., Burton-Sojo, G., Tankazyan, A., Wu, J., Hoang, T., Zhao, D., Wang, S., Hatch, M. M., et al. (2021) · Lab on a Chip · doi:10.1039/d0lc01216e · Cited by 124
Research works printed but not linked: 17
- Siegel, R. L., Miller, K. D., Wagle, N. S., Jemal, A. Cancer statistics, 2023. CA Cancer J Clin. 73(1), 17-48 (2023).
- Ewald, M. L., Chen, Y. H., Lee, A. P., Hughes, C. C. W. The vascular niche in next generation microphysiological systems. Lab Chip. 21(17), 3244-3262 (2021). Erratum in: Lab Chip. 21(18), 3615-3616 (2021). · doi:10.1039/d1lc90093e
- Shirure, V. S., Hughes, C. C. W., George, S. C. Engineering vascularized organoid-on-a-chip models. Annu Rev Biomed Eng. 23, 141-167 (2021). · DOI · Paper page
- Del Piccolo, N. et al. Tumor-on-chip modeling of organ-specific cancer and metastasis. Adv Drug Deliv Rev. 175, 113798 (2021). · DOI · Paper page
- Hachey, S. J. et al. A Human Vascularized Micro-Tumor Model of Patient-Derived Colorectal Cancer Recapitulates Clinical Disease. Transl Res. 255, 97-108 (2023). · DOI
- Liu, Y. et al. Human in vitro vascularized micro-organ and micro-tumor models are reproducible organ-on-a-chip platforms for studies of anticancer drugs. Toxicology. 445, 152601 (2020). · DOI
- Jahid, S. et al. Structure-based Design of CDC42 Effector Interaction Inhibitors for the Treatment of Cancer. Cell Rep. 39(4), 110760 (2022). · DOI
- Hsu, Y. H., Moya, M. L., Hughes, C. C. W., George, S. C., Lee, A. P. A microfluidic platform for generating large-scale nearly identical human microphysiological vascularized tissue arrays. Lab Chip. 13 (15), 2990-2998 (2013). · DOI · Paper page
- Wang, X. et al. An on-chip microfluidic pressure regulator that facilitates reproducible loading of cells and hydrogels into microphysiological system platforms. Lab Chip. 16 (5), 868-876 (2016). · DOI · Paper page
- Phan, D. T. et al. Blood-brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood-central nervous system interface. Exp Biol Med. 242 (17), 1669-1678 (2017). · DOI · Paper page
- Kurokawa, Y. K. et al. Human induced pluripotent stem cell-derived endothelial cells for three-dimensional microphysiological systems. Tissue Eng Part C: Methods. 23 (8), 474-484 (2017). · DOI · Paper page
- Schindelin, J. et al. Fiji: an open-source platform for biological-image analysis. Nat Methods. 9 (7), 676-682 (2012). · DOI · Paper page
- Carpenter, A. E. et al. CellProfiler: Image analysis software for identifying and quantifying cell phenotypes. Genome Biol. 7 (10), R100 (2006). · DOI · Paper page
- Zudaire, E., Gambardella, L., Kurcz, C., Vermeren, S. A computational tool for quantitative analysis of vascular networks. PLoS one. 6(11), e27385 (2011). · DOI · Paper page
- Corliss, B. A. et al. REAVER: A program for improved analysis of high-resolution vascular network images. Microcirculation. 27 (5), e12618 (2020). · DOI
- Urban, G. et al. Deep learning for drug discovery and cancer research: Automated analysis of vascularization images. IEEE/ACM Trans Comput Biol Bioinform. 16(3), 1029-1035 (2019). · DOI · Paper page
- COMSOL Multiphysics. www.comsol.com, COMSOL AB, Stockholm, Sweden. (2023).
Cited by
Hachey, S. J., Hatch, C. J., Gaebler, D., Mocherla, A., Nee, K., Kessenbrock, K., & Hughes, C. C. W. (2024) · Breast Cancer Research · doi:10.1186/s13058-023-01760-y · Cited by 24
“A published protocol was used to establish VMOs and VMTs [60].”
MethodSelf-citationMicrophysiological systems as models for immunologically ‘cold’ tumors
Gaebler, D., Hachey, S. J., & Hughes, C. C. W. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1389012 · Cited by 14
Self-citation
Metadata
- Authors
- Hachey, S. J., Gaebler, D., & Hughes, C. C. W.
- Venue
- Journal of Visualized Experiments
- Publisher
- MyJove Corporation
- Published
- 2023-09-15
- Issue
- 199
- ISSN
- 1940-087X
- Cited by
- 11
- References
- 8
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.