The DOI matches its Crossref record.
A microfluidic platform for generating large-scale nearly identical human microphysiological vascularized tissue arrays
Open accessAbstract
This paper reports a polydimethylsiloxane microfluidic model system that can develop an array of nearly identical human microtissues with interconnected vascular networks. The microfluidic system design is based on an analogy with an electric circuit, applying resistive circuit concepts to design pressure dividers in serially-connected microtissue chambers. A long microchannel (550, 620 and 775 mm) creates a resistive circuit with a large hydraulic resistance. Two media reservoirs with a large cross-sectional area and of different heights are connected to the entrance and exit of the long microchannel to serve as a pressure source, and create a near constant pressure drop along the long microchannel. Microtissue chambers (0.12 μl) serve as a two-terminal resistive component with an input impedance >50-fold larger than the long microchannel. Connecting each microtissue chamber to two different positions along the long microchannel creates a series of pressure dividers. Each microtissue chamber enables a controlled pressure drop of a segment of the microchannel without altering the hydrodynamic behaviour of the microchannel. The result is a controlled and predictable microphysiological environment within the microchamber. Interstitial flow, a mechanical cue for stimulating vasculogenesis, was verified by finite element simulation and experiments. The simplicity of this design enabled the development of multiple microtissue arrays (5, 12, and 30 microtissues) by co-culturing endothelial cells, stromal cells, and fibrin within the microchambers over two and three week periods. This methodology enables the culturing of a large array of microtissues with interconnected vascular networks for biological studies and applications such as drug development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 28
- Griffith, 2006, Nat. Rev. Mol. Cell Biol., 7, 211, 10.1038/nrm1858 · DOI · Paper page
- Chung, 2010, Ann. Biomed. Eng., 38, 1164, 10.1007/s10439-010-9899-3 · DOI
- Chung, 2009, Lab Chip, 9, 269, 10.1039/B807585A · DOI · Paper page
- Shin, 2011, Lab Chip, 11, 2175, 10.1039/c1lc20039a · DOI · Paper page
- Chung, 2009, Adv. Mater., 21, 4863, 10.1002/adma.200901727 · DOI
- Chrobak, 2006, Microvasc. Res., 71, 185, 10.1016/j.mvr.2006.02.005 · DOI · Paper page
- Borenstein, 2007, Tissue Eng., 13, 1837, 10.1089/ten.2006.0156 · DOI · Paper page
- Shin, 2004, Biomed. Microdevices, 6, 269, 10.1023/B:BMMD.0000048559.29932.27 · DOI · Paper page
- Berthiera, 2007, Lab Chip, 7, 1475, 10.1039/b707637a · DOI · Paper page
- Sudo, 2009, FASEB J., 23, 2155, 10.1096/fj.08-122820 · DOI · Paper page
- Jaasma, 2008, J. Biotechnol., 133, 490, 10.1016/j.jbiotec.2007.11.010 · doi:10.1016/j.jbiotec.2007.11.010
- Hegab, 2013, Biomicrofluidics, 7, 021502, 10.1063/1.4799966 · DOI
- Bonvin, 2010, Biotechnol. Bioeng., 105, 982, 10.1002/bit.22608 · DOI
- Nga, 2004, Microvasc. Res., 68, 258, 10.1016/j.mvr.2004.08.002 · DOI · Paper page
- Helm, 2005, Proc. Natl. Acad. Sci. U. S. A., 102, 15779, 10.1073/pnas.0503681102 · DOI · Paper page
- Hsu, 2013, Lab Chip, 13, 81, 10.1039/C2LC40787F · DOI
- Oh, 2012, Lab Chip, 12, 515, 10.1039/C2LC20799K · DOI · Paper page
- Walker, 2007, Lab Chip, 7, 226, 10.1039/B608990A · DOI
- Lee, 2009, Lab Chip, 9, 709, 10.1039/B813582G · DOI
- Jeon, 2000, Langmuir, 16, 8311, 10.1021/la000600b · DOI · Paper page
- Hung, 2005, Biotechnol. Bioeng., 89, 1, 10.1002/bit.20289 · DOI · Paper page
- Kim, 2011, Lab Chip, 11, 874, 10.1039/c0lc00516a · DOI
- Moya, 2013, Tissue Eng., Part C, 10.1089/ten.TEC.2012.0430 · DOI · Paper page
- Griffith, 2005, Tissue Eng., 11, 257, 10.1089/ten.2005.11.257 · DOI · Paper page
- Cox, 1986, J. Polym. Sci., Part A: Polym. Chem., 24, 621, 10.1002/pola.1986.080240405 · DOI
- Cho, 2007, J. Colloid Interface Sci., 306, 379, 10.1016/j.jcis.2006.10.077 · DOI · Paper page
- Chen, 2010, Tissue Eng. A, 16, 585, 10.1089/ten.tea.2009.0491 · DOI · Paper page
- Kamei, 2006, Nature, 442, 453, 10.1038/nature04923 · DOI · Paper page
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Vascularization and Angiogenesis in Tissue Engineering: Beyond Creating Static Networks
Rouwkema, J., & Khademhosseini, A. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.03.002 · Cited by 651
Consensus guidelines for the use and interpretation of angiogenesis assays
Nowak-Sliwinska, P., Alitalo, K., Allen, E., Anisimov, A., Aplin, A. C., Auerbach, R., Augustin, H. G., Bates, D. O., van Beijnum, J. R., Bender, R. H. F., et al. (2018) · Angiogenesis · doi:10.1007/s10456-018-9613-x · Cited by 590
Self-citation
Metadata
- Authors
- Hsu, Y.-H., Moya, M. L., Hughes, C. C. W., George, S. C., & Lee, A. P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 15
- Pages
- 2990
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2024343337
- Cited by
- 192
- References
- 0
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfluidic platform for generating large-scale nearly identical human microphysiological vascularized tissue arrays. https://app.cochat.ai/papers/10.1039/c3lc50424g
- The paper
- Hsu, Y.-H., Moya, M. L., Hughes, C. C. W., George, S. C., & Lee, A. P. (2013). A microfluidic platform for generating large-scale nearly identical human microphysiological vascularized tissue arrays. Lab on a Chip. https://doi.org/10.1039/c3lc50424g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.