Corneal Aberrations and Visual Performance After Radial Keratotomy
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Refractive surgery and videokeratography have allowed us to study the effects on visual performance of relatively large changes in corneal aberration structure induced by surgical changes in corneal shape. METHODS: We quantified in one eye of nine normal and 23 radial keratotomy patients, the area under the log contrast sensitivity function (AULCSF) and corneal first surface wavefront variance for two artificial pupil sizes (3 and 7 mm). Contrast sensitivity was measured with sine-wave gratings at six spacial frequencies. Wavefront variance was derived from videokeratographs using Zernike polynomials. RESULTS: For normals eyes there were no significant changes over time. For eyes that had radial keratotomy, there were significant pupil sizedependent changes. For the 3 mm pupil, there were significant surgery-induced changes in the corneal wavefront variance which became large (approximately 30 times preoperative values) at 7 mm. Significant correlated changes in AULCSF for the 7 mm pupil but not for the 3 mm pupil occurred immediately following surgery and remained. CONCLUSIONS: Radial keratotomy, like photorefractive keratectomy, shifts the distribution of aberrations from third order dominance (coma-like aberrations) to fourth order dominance (sphericallike aberrations). Radial keratotomy-induced aberrations and loss in contrast sensitivity are reduced with increasing clear zone diameter. Radial keratotomy induces an increase in the optical aberrations of the eye and the increase for large pupils (7 mm) but not small (3 mm) is correlated to a decrease in contrast sensitivity. [J Retract Surg 1998;14:397-4071
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New Visual Acuity Charts for Clinical Research
Ferris, F. L., Kassoff, A., Bresnick, G. H., & Bailey, I. (1982) · American Journal of Ophthalmology · doi:10.1016/0002-9394(82)90197-0 · Cited by 2,142
(2007) · Wiley eBooks · doi:10.1002/9780470135976 · Cited by 2,092
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
New Design Principles for Visual Acuity Letter Charts
Bailey, I. L., & Lovie, J. E. (1976) · American journal of optometry and physiological optic · doi:10.1002/j.2330-9512.1976.tb02218.x · Cited by 1,407
Liang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195
Aberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Introductory Mathematical Statistics
Kreyszig, E. (1970) · Cited by 478
A subjective method for the measurement of monochromatic* aberrations of the eye
Howland, H. C., & Howland, B. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001508 · Cited by 379
Self-citationTheory and measurement of ocular chromatic aberration
Thibos, L. N., Bradley, A., Still, D. L., Zhang, X., & Howarth, P. A. (1990) · Vision Research · doi:10.1016/0042-6989(90)90126-6 · Cited by 257
Objective technique for the determination of monochromatic aberrations of the human eye
Walsh, G., Howland, H. C., & Charman, W. N. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000987 · Cited by 220
Self-citationMonochromatic aberrations and myopia
Collins, M. J., Wildsoet, C. F., & Atchison, D. A. (1995) · Vision Research · doi:10.1016/0042-6989(94)00236-f · Cited by 164
Corneal Optical Aberrations Induced by Photorefractive Keratectomy
Oliver, K. M., Hemenger, R. P., Corbett, M. C., O'Brart, D. P. S., Verma, S., Marshall, J., & Tomlinson, A. (1997) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19970501-10 · Cited by 163
Visual Performance After Photorefractive Keratectomy
Verdon, W. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100140663003 · Cited by 151
Rynders, M. C., Lidkea, B., Chisholm, W., & Thibos, L. N. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.002348 · Cited by 121
The optical transverse chromatic aberration on the fovea of the human eye
Simonet, P., & Campbell, M. C. W. (1990) · Vision Research · doi:10.1016/0042-6989(90)90035-j · Cited by 109
Optical Modeling of Radial Keratotomy Incision Patterns
Schwiegerling, J. T., Greivenkamp, J. E., Miller, J. M., Snyder, R. W., & Palmer, M. L. (1996) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)70377-0 · Cited by 26
Cited by
Bayesian adaptive estimation of the contrast sensitivity function: The quick CSF method
Lesmes, L. A. (2010) · Journal of Vision · doi:10.1167/10.3.17 · Cited by 333
The Cornea is Not a Piece of Plastic
Roberts, C. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000701-03 · Cited by 326
Owsley, C., & McGwin, G. (1999) · Survey of Ophthalmology · doi:10.1016/s0039-6257(99)00035-1 · Cited by 289
Corneal First Surface Optical Aberrations and Visual Performance
Applegate, R. A., Hilmantel, G., Howland, H. C., Tu, E. Y., Starck, T., & Zayac, E. J. (2000) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20000901-04 · Cited by 256
Self-citationYamane, N., Miyata, K., Samejima, T., Hiraoka, T., Kiuchi, T., Okamoto, F., Hirohara, Y., Mihashi, T., & Oshika, T. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0629 · Cited by 238
“Applegate et al.9 demonstrated that increases in the optical aberrations of the cornea after radial keratotomy correlated with decreases in AULCSF.”
BackgroundMethodInfluential
Metadata
- Authors
- Applegate, R. A., Howland, H. C., Sharp, R. P., Cottingham, A. J., & Yee, R. W.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 1998-07
- Volume
- 14
- Issue
- 4
- Pages
- 397-407
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2410184408
- Cited by
- 307
- References
- 16
- FWCI
- 10.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.