Effectiveness of D-dimer as a screening test for venous thromboembolism: An update
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Venous thromboembolism (VTE) is the leading cause of morbidity and mortality among hospitalized patients. We searched the PubMed database and reviewed the articles published until June 2011. Articles related to the D-dimer and VTE were considered to write this paper. Many factors play a key role in changing the sensitivity and specificity of D-dimer testing, including the extent of thrombosis and fibrinolytic activity, duration of symptoms, anticoagulant therapy, comorbidity due to surgical or medical illnesses, inflammatory diseases, cancer, elderly age, pregnancy and the postpartum period, and previous VTE. Many previous studies have shown that the D-dimer test is highly sensitive (>95%) in acute deep venous thrombosis or pulmonary embolism, usually with a cut-off value of 500 μg FEU/l, which reasonably rules out acute VTE, particularly in patients with low clinical probability (LCP) or intermediate clinical probability. Patients with high D-dimer levels upon presentation may prompt a more intense diagnostic approach, irrespective of pretest probability. Studies performed after a negative D-dimer for 3 months proved the high negative predictive value (NPV) of D-dimer testing together with LCP in patients with suspected VTE. Among oncology patients, D-dimer testing has the highest sensitivity and NPV in excluding VTE. The new cutoff values of D-dimer testing were analyzed in a recent prospective study of pregnant women; they are 286 ng DDU/ml, 457 ng DDU/ml, and 644 ng DDU/ml for the first, second, and third trimesters, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Differential Diagnosis of Glomerular Disease: A Systematic and Inclusive Approach
Hebert, L. A., Parikh, S., Prosek, J., Nadasdy, T., & Rovin, B. H. (2013) · American Journal of Nephrology · doi:10.1159/000354390 · Cited by 4,376
Antithrombotic Therapy for Venous Thromboembolic Disease
Hyers, T. M., Agnelli, G., Hull, R. D., Morris, T. A., Samama, M., Tapson, V., & Weg, J. G. (2001) · Chest · doi:10.1378/chest.119.1_suppl.176s · Cited by 2,042
Multidetector Computed Tomography for Acute Pulmonary Embolism
Stein, P. D., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Leeper, K. V., Popovich, J., Quinn, D. A., Sos, T. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052367 · Cited by 1,660 · cited 5×
“[3] In a prospective cohort study of 807 patients, the authors concluded that four CPRs-Wells’ rule, simpli fi ed Wells’ rule, revised Geneva score, and simplified revised Geneva score-show similar performance with a normal D-dimer to exclude PE.”
InfluentialAnderson, D., Rodger, M., Ginsberg, J., Kearon, C., Gent, M., Turpie, A., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., et al. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613830 · Cited by 1,659 · cited 2×
“North American Journal of Medical Sciences | Oct 2014 | Volume 6 | Issue 10 | 492 variables and is independent of physician judgment.[3,4] The prevalence of PE was 8%, 28%, and 74% in patients with LCP, ICP, and HCP, respectively.”
Evaluation of D-Dimer in the Diagnosis of Suspected Deep-Vein Thrombosis
Wells, P. S., Anderson, D. R., Rodger, M., Forgie, M., Kearon, C., Dreyer, J., Kovacs, G., Mitchell, M., Lewandowski, B., & Kovacs, M. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa023153 · Cited by 1,552 · cited 2×
“marker of endogenous fi brinolysis.[1] The purpose of this”
Antithrombotic Therapy for Venous Thromboembolic Disease
Büller, H. R., Agnelli, G., Hull, R. D., Hyers, T. M., Prins, M. H., & Raskob, G. E. (2004) · Chest · doi:10.1378/chest.126.3_suppl.401s · Cited by 1,249
Value of assessment of pretest probability of deep-vein thrombosis in clinical management
Wells, P. S., Anderson, D. R., Bormanis, J., Guy, F., Mitchell, M., Gray, L., Clement, C., Robinson, K. S., & Lewandowski, B. (1997) · The Lancet · doi:10.1016/s0140-6736(97)08140-3 · Cited by 1,229
The Role of CT Pulmonary Angiography in the Investigation of Unilateral Pleural Effusions
Hooper, C., Laurence, I., Harvey, J., Morley, A., Darby, M., Edey, A., & Maskell, N. (2014) · Respiration · doi:10.1159/000347003 · Cited by 1,184
(2006) · JAMA · doi:10.1001/jama.295.2.172 · Cited by 1,129 · cited 3×
“7% (7/1028) at a follow-up of 3 months.[21] In a study of 1096 patients with suspected DVT, who had LCP and negative D-dimer, the incidence of VTE in the next 3 months was 0.”
InfluentialPrediction of Pulmonary Embolism in the Emergency Department: The Revised Geneva Score
Le Gal, G., Righini, M., Roy, P.-M., Sanchez, O., Aujesky, D., Bounameaux, H., & Perrier, A. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-3-200602070-00004 · Cited by 1,121 · cited 2×
“North American Journal of Medical Sciences | Oct 2014 | Volume 6 | Issue 10 | 492 variables and is independent of physician judgment.[3,4] The prevalence of PE was 8%, 28%, and 74% in patients with LCP, ICP, and HCP, respectively.”
d-Dimer for the Exclusion of Acute Venous Thrombosis and Pulmonary Embolism: A Systematic Review
Stein, P. D., Hull, R. D., Patel, K. C., Olson, R. E., Ghali, W. A., Brant, R., Biel, R. K., Bharadia, V., & Kalra, N. K. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-8-200404200-00005 · Cited by 800 · cited 1×
“,[12] which included 31 studies to determine the accuracy of D-dimer testing in patients with suspected VTE, the prevalence of VTE ranged from 20% to 78% (average, 36%).”
Prandoni, P., Noventa, F., Ghirarduzzi, A., Pengo, V., Bernardi, E., Pesavento, R., Iotti, M., Tormene, D., Simioni, P., & Pagnan, A. (2007) · Haematologica · doi:10.3324/haematol.10516 · Cited by 776
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
Perrier, A., Roy, P.-M., Sanchez, O., Le Gal, G., Meyer, G., Gourdier, A.-L., Furber, A., Revel, M.-P., Howarth, N., Davido, A., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042905 · Cited by 642
Assessing Risk of Venous Thromboembolism in the Patient With Cancer
Khorana, A. A., & Connolly, G. C. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2009.22.3271 · Cited by 539 · cited 3×
“[45] Laboratory biomarkers that predict VTE are thrombocytosis or leukocytosis, tissue factor, soluble P-selectin, and D-dimer.[50] In the prospective study involving 2263 consecutive patients with suspected DVT, independent poor prognostic factors were found for overall survival, including D-dimer levels >8000 ng FEU…”
Eichinger, S., Heinze, G., Jandeck, L. M., & Kyrle, P. A. (2010) · Circulation · doi:10.1161/circulationaha.109.925214 · Cited by 510 · cited 1×
“Gender, proximal versus distal DVT, PE versus distal thrombosis, and elevated levels of D-dimer per doubling were related to a higher recurrence risk.[70]”
Diagnostic accuracy of D‐dimer test for exclusion of venous thromboembolism: a systematic review
DI NISIO, M., SQUIZZATO, A., RUTJES, A. W. S., BÜLLER, H. R., ZWINDERMAN, A. H., & BOSSUYT, P. M. M. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02328.x · Cited by 465 · cited 1×
“[21] In a meta-analysis, Di Nisio et al.[34] analyzed the accuracy of different D-dimer assays from 113 individual studies and confi rmed that the ELISA, the microplate ELISA, and the automated quantitative latex assays have a higher sensitivity but a lower specifi city, resulting in a more confi dent exclusion of the…”
Goldhaber, S. Z. (1998) · New England Journal of Medicine · doi:10.1056/nejm199807093390207 · Cited by 428
Righini, M., Le Gal, G., Aujesky, D., Roy, P.-M., Sanchez, O., Verschuren, F., Rutschmann, O., Nonent, M., Cornuz, J., Thys, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60594-2 · Cited by 420 · cited 3×
“[1] In a multicenter study, the D-dimer test excluded PE in 561 patients (n = 1819) with LCP or ICP, and none of these patients had VTE in the 3-month follow-up, with a D-dimer below 500 μg FEU/l.[36]”
D‐Dimer for venous thromboembolism diagnosis: 20 years later
RIGHINI, M., PERRIER, A., DE MOERLOOSE, P., & BOUNAMEAUX, H. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.02981.x · Cited by 374
Chronic Kidney Disease Increases Risk for Venous Thromboembolism
Wattanakit, K., Cushman, M., Stehman-Breen, C., Heckbert, S. R., & Folsom, A. R. (2008) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007030308 · Cited by 359
D-Dimer Levels and Risk of Recurrent Venous Thromboembolism
Eichinger, S. (2003) · JAMA · doi:10.1001/jama.290.8.1071 · Cited by 327
Appropriateness of Diagnostic Management and Outcomes of Suspected Pulmonary Embolism
Roy, P.-M., Meyer, G., Vielle, B., Le Gall, C., Verschuren, F., Carpentier, F., Leveau, P., Furber, A., & for the EMDEPU Study Group* (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-3-200602070-00003 · Cited by 324 · cited 2×
“[6] Another study showed that 40% of inappropriate diagnostic strategies were attributable to the physician’s failure to properly incorporate CPRs into their diagnostic decision.[7]”
Douma, R. A., Mos, I. C. M., Erkens, P. M. G., Nizet, T. A. C., Durian, M. F., Hovens, M. M., van Houten, A. A., Hofstee, H. M. A., Klok, F. A., ten Cate, H., et al. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-11-201106070-00002 · Cited by 261 · cited 5×
“[3] In a prospective cohort study of 807 patients, the authors concluded that four CPRs-Wells’ rule, simpli fi ed Wells’ rule, revised Geneva score, and simplified revised Geneva score-show similar performance with a normal D-dimer to exclude PE.”
InfluentialD-Dimer Concentrations in Normal Pregnancy: New Diagnostic Thresholds Are Needed
Kline, J. A., Williams, G. W., & Hernandez-Nino, J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.044883 · Cited by 251 · cited 1×
“5 mg FEU/l) during the fi rst, second, and third trimesters, respectively.[61] In another prospective study of 89 pregnant women, D-dimer testing had 100% sensitivity at the new cutoff values for the fi rst, second, and third trimesters (286 ng DDU/ml, 457 ng DDU/ml, and 644 ng DDU/ml, respectively).”
Douketis, J., Tosetto, A., Marcucci, M., Baglin, T., Cushman, M., Eichinger, S., Palareti, G., Poli, D., Tait, R. C., & Iorio, A. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-153-8-201010190-00009 · Cited by 175 · cited 1×
“This was independent of patient age or timing of the postanticoagulation D-dimer testing.[68] In another prospective cohort study, 79 (13%) of 610 patients had recurrent VTE with a mean follow-up of 38 months, and they had signifi cantly higher D-dimer levels.”
Brown, M. D., Rowe, B. H., Reeves, M. J., Bermingham, J. M., & Goldhaber, S. Z. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.124755 · Cited by 173
The use of D-dimer with new cutoff can be useful in diagnosis of venous thromboembolism in pregnancy
Kovac, M. K., Miković, Ž., Rakicevic, L. B., Srzentic, S. J., Mandić, V., Djordjevic, V. J., Radojkovic, D. P., & Elezović, I. V. (2009) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2009.09.005 · Cited by 135 · cited 1×
“[62] In his study on 48 pregnant women, Morse[63] tried to establish a new reference range for D-dimer levels during pregnancy.”
Clinical usefulness of D-dimer testing in cancer patients with suspected pulmonary embolism
Gal, G. L., Lucia, S. D., Roy, P., Meyer, G., Aujesky, D., Bounameaux, H., Perrier, A., & Righini, M. (2006) · Thrombosis and Haemostasis · doi:10.1160/th05-12-0791 · Cited by 135 · cited 1×
“The sensitivity and NPV were 100% in both cancer and noncancer patients.[57] Regarding VTE recurrence in oncology patients, D-dimer and residual venous obstruction (RVO) are considered independent risk factors, and may help tailor anticoagulation treatment duration.”
A Red Blood Cell Agglutination d-Dimer Test to Exclude Deep Venous Thrombosis in Pregnancy
Chan, W.-S., Chunilal, S., Lee, A., Crowther, M., Rodger, M., & Ginsberg, J. S. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-3-200708070-00005 · Cited by 134 · cited 2×
“The relative risk of recurrence was 60% lower in patients with D-dimer levels <250 ng FEU/ml compared with patients with higher D-dimer levels.[60] In a prospective cohort study, 929 patients after fi rst unprovoked VTE were followed for 43.”
Elevated levels of soluble fibrin or D‐dimer indicate high risk of thrombosis
Wada, H., Kobayashi, T., Abe, Y., Hatada, T., Yamada, N., Sudo, A., UCHIDA, A., & Nobori, T. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01942.x · Cited by 108 · cited 1×
“,[42] 87 out of 754 patients had DVT, and the highest levels of D-dimer were seen on the 2nd day of clinical presentation.”
Influence of age on the cost‐effectiveness of diagnostic strategies for suspected pulmonary embolism
Righini, M., NENDAZ, M. R., Gal, G. L., Bounameaux, H. M., & Perrier, A. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02667.x · Cited by 102 · cited 1×
“An analysis reported no clear advantage of measuring D-dimer after the age of 80, except when the risk of performing CT was too high due to impaired renal function.[47] In a study by Legnani et al.”
Help me, Doctor! My D-dimer is raised
Lippi, G., Franchini, M., Targher, G., & Favaloro, E. J. (2008) · Annals of Medicine · doi:10.1080/07853890802161015 · Cited by 94 · cited 1×
“[10] Pathologic causes for D-dimer elevation are listed in Table 2.[10,11] Many strategies have been proposed for diagnosing VTE, including testing for D-dimer after a fi rst negative imaging test to identify patients who require a new specifi c evaluation, initial D-dimer testing for the exclusion of VTE with further…”
Gal, G. L., Righini, M., Roy, P., Sanchez, O., Aujesky, D., Perrier, A., & Bounameaux, H. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.2.176 · Cited by 91 · cited 1×
“The recurrence risk was 0% during the next 3 months in patients with previous VTE and a negative D-dimer test who did not receive anticoagulation.[66] Surprisingly, the 2-fold lower chance of a negative D-dimer test result in patients with previous VTE was not infl uenced by older age, cancer, recent surgery, or acute…”
Runyon, M. S., Richman, P. B., & Kline, J. A. (2006) · Academic Emergency Medicine · doi:10.1197/j.aem.2006.07.032 · Cited by 85 · cited 2×
“[6] In this study, physicians did not apply CPRs for suspected VTE due to medico-legal concerns, dif fi culty in memorizing and implementing the rules, the belief that clinical con fi guration is better, and the belief that none of the rules has been validated to their satisfaction.”
Negative d -dimer Result To Exclude Recurrent Deep Venous Thrombosis: A Management Trial
Rathbun, S. W., Whitsett, T. L., & Raskob, G. E. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-11-200412070-00007 · Cited by 83 · cited 1×
“[64] Rathbun et al.[65] reported the results of a D-dimer test to exclude recurrent DVT in 300 patients with suspected DVT, who had a previous episode of DVT.”
Accuracy of d-dimer/fibrinogen ratio to predict pulmonary embolism: a prospective diagnostic study
Kucher, N., Kohler, H. P., Doernhoefer, T., Wallmann, D., & Lämmle, B. (2003) · Journal of Thrombosis and Haemostasis · doi:10.1046/j.1538-7836.2003.00145.x · Cited by 80
Speiser, W., Mallek, R., Koppensteiner, R., Andreas, S., Kapiotis, S., Minar, E., Ehringer, H., & Lechner, K. (1990) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1647284 · Cited by 79 · cited 1×
“[39] Similar fi ndings were noted by Speiser et al.[40] (n = 39) and Heit et al.”
D‐Dimer test in cancer patients with suspected acute pulmonary embolism
Nisio, M. D., Söhne, M., Kamphuisen, P. W., & Buller, H. R. (2005) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01323.x · Cited by 64 · cited 1×
“Another study reported a highest sensitivity (100%; 95% CI, 82-100%) and NPV (100%; 95% CI, 72-100%) in a sample of 72 cancer patients.[56] These data were confirmed in a second larger study, which involved a large cohort of 1721 outpatients.”
Lee-Lewandrowski, E., Nichols, J., Van Cott, E., Grisson, R., Louissaint, A., Benzer, T., & Lewandrowski, K. (2009) · American Journal of Clinical Pathology · doi:10.1309/ajcp6us3ilgearee · Cited by 56 · cited 1×
“9%), and the positive predictive value was poor for both tests.[30] The immunoturbidimetric monoclonal antibody method (Innovance D-dimer assay, Siemens Healthcare Diagnostics) has high enough sensitivity and NPV to be used as a standalone test in patients with a nonhigh PTP score, and the test provides quantitative a…”
Acquired Risk Factors for Venous Thromboembolism in Medical Patients
Prandoni, P. (2005) · Hematology · doi:10.1182/asheducation-2005.1.458 · Cited by 52 · cited 1×
“The risk factors for VTE are increasing age, cancer and its treatment, paralysis, prolonged immobility, long air travel, congestive heart failure, acute infection, pregnancy or puerperium, hormonal treatment, varicose veins, dehydration, previous VTE, infl ammatory bowel disease, rheumatologic disease, nephrotic syndr…”
Legnani, C., Palareti, G., Cosmi, B., Cini, M., Tosetto, A., & Tripodi, A. (2008) · Haematologica · doi:10.3324/haematol.12320 · Cited by 48 · cited 3×
“[27] In a study comparing the quantitative D-dimer levels to the presence of PE in symptomatic patients, PE prevalence was strongly related to the D-dimer level and increased 4 times with D-dimer levels >4000 ng FEU/ml compared with levels between 500 and 1000 ng FEU/ml. [28] In a study performed in an out-patient set…”
Cosmi, B., Legnani, C., Cini, M., Guazzaloca, G., & Palareti, G. (2005) · PubMed · Cited by 47
Legnani, C., Cini, M., Scarvelis, D., Toulon, P. A., Wu, J. R., & Palareti, G. (2009) · Thrombosis Research · doi:10.1016/j.thromres.2009.07.013 · Cited by 43
High D‐dimer levels increase the likelihood of pulmonary embolism
Tick, L. W., Nijkeuter, M., Kramer, M. H. H., et al. (2008) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2008.01972.x · Cited by 42 · cited 3×
“[27] In a study comparing the quantitative D-dimer levels to the presence of PE in symptomatic patients, PE prevalence was strongly related to the D-dimer level and increased 4 times with D-dimer levels >4000 ng FEU/ml compared with levels between 500 and 1000 ng FEU/ml. [28] In a study performed in an out-patient set…”
Nisio, M. D., Rutjes, A. W., & Buller, H. R. (2005) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01671.x · Cited by 40 · cited 1×
“[54] Di Nisio et al.[55] analyzed 2066 patients and found that the NPV for the test was 100% and 97% among cancer patients with LCP and ICP, respectively.”
Evaluation of Wells score and repeated D-dimer in diagnosing venous thromboembolism
Ljungqvist, M., Söderberg, M., Moritz, P., Ahlgren, A., & Lärfars, G. (2008) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2007.08.007 · Cited by 33 · cited 1×
“The authors concluded that the normal D-dimer and LCP safely excluded VTE in emergency department patients, and follow-up D-dimer testing added no further information.[18] In a study of 197 out-patients and in-patients, many patients were not included in the HCP category as the Wells chart for PE has a high verge for…”
Update on the predictive value of D-dimer in patients with idiopathic venous thromboembolism
Cosmi, B., & Palareti, G. (2010) · Thrombosis Research · doi:10.1016/s0049-3848(10)70016-5 · Cited by 28 · cited 2×
“2% annual recurrence rates, respectively.[67] In a study of 1818 patients, the risk of recurrent VTE was higher among patients with positive D-dimer levels than those with negative results during a follow-up period of 26.”
Lee, J., & Zierler, B. K. (2010) · Vascular and Endovascular Surgery · doi:10.1177/1538574410385873 · Cited by 11 · cited 3×
“In their retrospective study of 1161 patients, Lee and Zierler[8] made a statement about the under usage of the diagnostic strategy with CPRs and D-dimer as initial screening followed for suspected VTE.”
Cited by
Coagulation and anticoagulation in COVID-19
Hadid, T., Kafri, Z., & Al-Katib, A. (2021) · Blood Reviews · doi:10.1016/j.blre.2020.100761 · Cited by 223
“Quantitative D-dimer is a useful tool for the diagnosis and prediction of recurrence of VTE [29,30].”
The Developing Story of Predictive Biomarkers in Colorectal Cancer
Boussios, S., Ozturk, M., Moschetta, M., Karathanasi, A., Zakynthinakis-Kyriakou, N., Katsanos, K., Christodoulou, D., & Pavlidis, N. (2019) · Journal of Personalized Medicine · doi:10.3390/jpm9010012 · Cited by 168
Liu, X., Wang, S., Cao, S., He, X., Qin, L., He, M., Yang, Y., Hao, J., & Mao, W. (2018) · Marine Drugs · doi:10.3390/md16070243 · Cited by 63
Metadata
- Authors
- Gurram, M., & Pulivarthi, S.
- Venue
- North American Journal of Medical Sciences
- Publisher
- Medknow
- Published
- 2014
- Volume
- 6
- Issue
- 10
- Pages
- 491
- ISSN
- 1947-2714 (ISSN-L)
- OpenAlex
- W2016499071
- Cited by
- 181
- References
- 48
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.