CoChat

Management of coronary artery disease in patients undergoing transcatheter aortic valve implantation. A clinical consensus statement from the European Association of Percutaneous Cardiovascular Interventions in collaboration with the ESC Working Group on Cardiovascular Surgery

Open access
Tarantini, Giuseppe, Tang, Gilbert, Nai Fovino, Luca, Blackman, Daniel, Van Mieghem, Nicolas M., Kim, Won-Keun, Karam, Nicole, Carrilho-Ferreira, Pedro, Fournier, Stephane, Pręgowski, Jerzy, Fraccaro, Chiara, Vincent, Flavien, Campante Teles, Rui, Mylotte, Darren, Wong, Ivan, Bieliauskas, Gintautas, Czerny, Martin, Bonaros, Nikolaos, Parolari, Alessandro, Dudek, Darius, Tchetche, Didier, Eltchaninoff, Hélène, de Backer, Ole, Stefanini, Giulio, Sondergaard, Lars · 2023 · EuroIntervention
Cited by 164

The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.

Abstract

Significant coronary artery disease (CAD) is a frequent finding in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI), and the management of these two conditions becomes of particular importance with the extension of the procedure to younger and lower-risk patients.Yet, the preprocedural diagnostic evaluation and the indications for treatment of significant CAD in TAVI candidates remain a matter of debate.In this clinical consensus statement, a group of experts from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the European Society of Cardiology (ESC) Working Group on Cardiovascular Surgery aims to review the available evidence on the topic and proposes a rationale for the diagnostic evaluation and indications for percutaneous revascularisation of CAD in patients with severe aortic stenosis undergoing transcatheter treatment.Moreover, it also focuses on commissural alignment of transcatheter heart valves and coronary re-access after TAVI and redo-TAVI.KEYWORDS • aortic stenosis • coronary artery disease • TAVI ACS acute coronary syndrome AS aortic stenosis BASILICA Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction CABG coronary artery bypass grafting CAD coronary artery disease CMR cardiac magnetic resonance EAPCI European Association of Percutaneous Cardiovascular Interventions FFR fractional flow reserve ICA invasive coronary angiography iFR instantaneous wave-free ratio MSCT multislice computed tomography PCI percutaneous coronary intervention SAVR surgical aortic valve replacement TAVI transcatheter aortic valve implantation THV transcatheter heart valve

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4244/eij-d-22-00958

Cites

78 of 78 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 164

Metadata

Authors
Tarantini, G., Tang, G., Nai Fovino, L., Blackman, D., Van Mieghem, N. M., Kim, W.-K., Karam, N., Carrilho-Ferreira, P., Fournier, S., Pręgowski, J., Fraccaro, C., Vincent, F., Campante Teles, R., Mylotte, D., Wong, I., Bieliauskas, G., Czerny, M., Bonaros, N., Parolari, A., Dudek, D., Tchetche, D., Eltchaninoff, H., de Backer, O., Stefanini, G., & Sondergaard, L.
Venue
EuroIntervention
Published
2023-05
Volume
19
Issue
1
Pages
37-52
ISSN
1774-024X (ISSN-L)
OpenAlex
W4321612395
Cited by
164
References
78
FWCI
28.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.