Computed tomography and patient risk: Facts, perceptions and uncertainties
Open accessThe DOI matches its Crossref record; 112 of the 112 references it cites were found in a registry or an index.
Abstract
Since its introduction in the 1970s, computed tomography (CT) has revolutionized diagnostic decision-making. One of the major concerns associated with the widespread use of CT is the associated increased radiation exposure incurred by patients. The link between ionizing radiation and the subsequent development of neoplasia has been largely based on extrapolating data from studies of survivors of the atomic bombs dropped in Japan in 1945 and on assessments of the increased relative risk of neoplasia in those occupationally exposed to radiation within the nuclear industry. However, the association between exposure to low-dose radiation from diagnostic imaging examinations and oncogenesis remains unclear. With improved technology, significant advances have already been achieved with regards to radiation dose reduction. There are several dose optimization strategies available that may be readily employed including omitting unnecessary images at the ends of acquired series, minimizing the number of phases acquired, and the use of automated exposure control as opposed to fixed tube current techniques. In addition, new image reconstruction techniques that reduce radiation dose have been developed in recent years with promising results. These techniques use iterative reconstruction algorithms to attain diagnostic quality images with reduced image noise at lower radiation doses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
Brenner, D. J., Doll, R., Goodhead, D. T., Hall, E. J., Land, C. E., Little, J. B., Lubin, J. H., Preston, D. L., Preston, R. J., Puskin, J. S., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2235592100 · Cited by 1,765
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Survival of Patients with Stage I Lung Cancer Detected on CT Screening
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa060476 · Cited by 1,706
Kuppermann, N., Holmes, J. F., Dayan, P. S., Hoyle, J. D., Atabaki, S. M., Holubkov, R., Nadel, F. M., Monroe, D., Stanley, R. M., Borgialli, D. A., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61558-0 · Cited by 1,631
Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., et al. (2013) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901249 · Cited by 1,338
Cancer risk in patients with inflammatory bowel disease: A population-based study
Bernstein, C. N., Blanchard, J. F., Kliewer, E., & Wajda, A. (2001) · Cancer · doi:10.1002/1097-0142(20010215)91:4<854::aid-cncr1073>3.0.co;2-z · Cited by 1,165
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Self-citationA three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Tumors of the Brain and Nervous System after Radiotherapy in Childhood
Ron, E., Modan, B., Boice, J. D., Alfandary, E., Stovall, M., Chetrit, A., & Katz, L. (1988) · New England Journal of Medicine · doi:10.1056/nejm198810203191601 · Cited by 934
Smith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898
Mettler, F. A., Bhargavan, M., Faulkner, K., Gilley, D. B., Gray, J. E., Ibbott, G. S., Lipoti, J. A., Mahesh, M., McCrohan, J. L., Stabin, M. G., et al. (2009) · Radiology · doi:10.1148/radiol.2532082010 · Cited by 853
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
CT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · RadioGraphics · doi:10.1148/rg.262055138 · Cited by 768
Lee, C. I., Haims, A. H., Monico, E. P., Brink, J. A., & Forman, H. P. (2004) · Radiology · doi:10.1148/radiol.2312030767 · Cited by 700
Cardis, E., Vrijheid, M., Blettner, M., Gilbert, E., Hakama, M., Hill, C., Howe, G., Kaldor, J., Muirhead, C. R., Schubauer-Berigan, M., et al. (2007) · Radiation Research · doi:10.1667/rr0553.1 · Cited by 679
CT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
Radiation Protection in Medicine
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2008.07.001 · Cited by 641
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Silva, A. C., Lawder, H. J., Hara, A., Kujak, J., & Pavlicek, W. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.2953 · Cited by 560
The Linear No-Threshold Relationship Is Inconsistent with Radiation Biologic and Experimental Data
Tubiana, M., Feinendegen, L. E., Yang, C., & Kaminski, J. M. (2009) · Radiology · doi:10.1148/radiol.2511080671 · Cited by 509
MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTS
Mettler, F. A., Thomadsen, B. R., Bhargavan, M., Gilley, D. B., Gray, J. E., Lipoti, J. A., McCrohan, J., Yoshizumi, T. T., & Mahesh, M. (2008) · Health Physics · doi:10.1097/01.hp.0000326333.42287.a2 · Cited by 507
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Guidelines for Computed Tomography and Magnetic Resonance Imaging Use During Pregnancy and Lactation
Chen, M. M., Coakley, F. V., Kaimal, A., & Laros, R. K. (2008) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e318180a505 · Cited by 468
Muirhead, C. R., O'Hagan, J. A., Haylock, R. G. E., Phillipson, M. A., Willcock, T., Berridge, G. L. C., & Zhang, W. (2009) · British Journal of Cancer · doi:10.1038/sj.bjc.6604825 · Cited by 423
Brent, R. L. (1989) · PubMed · Cited by 400
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380
Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique
Prakash, P., Kalra, M. K., Kambadakone, A., et al. (2010) · Investigative Radiology · doi:10.1097/rli.ob013e3181dzfeec · Cited by 366
Doctors' knowledge of radiation exposure: questionnaire study: TABLE 1
Shiralkar, S., Rennie, A., Snow, M., Galland, R. B., Lewis, M. H., & Gower-Thomas, K. (2003) · BMJ · doi:10.1136/bmj.327.7411.371 · Cited by 362
van Randen, A., Bipat, S., Zwinderman, A. H., Ubbink, D. T., Stoker, J., & Boermeester, M. A. (2008) · Radiology · doi:10.1148/radiol.2483071652 · Cited by 357
Radiation Risks of Medical Imaging: Separating Fact from Fantasy
Hendee, W. R., & O’Connor, M. K. (2012) · Radiology · doi:10.1148/radiol.12112678 · Cited by 354
Managing Radiation Use in Medical Imaging: A Multifaceted Challenge
Hricak, H., Brenner, D. J., Adelstein, S. J., Frush, D. P., Hall, E. J., Howell, R. W., McCollough, C. H., Mettler, F. A., Pearce, M. S., Suleiman, O. H., et al. (2011) · Radiology · doi:10.1148/radiol.10101157 · Cited by 342
Crohn's disease: factors associated with exposure to high levels of diagnostic radiation
Desmond, A. N., O'Regan, K., Curran, C., McWilliams, S., Fitzgerald, T., Maher, M. M., & Shanahan, F. (2008) · Gut · doi:10.1136/gut.2008.151415 · Cited by 324
Self-citation120 Crohn's Disease: Factors Associated with Exposure to High Levels of Diagnostic Radiation
Desmond, A. N., O'Regan, K. N., Curran, C., McWilliams, S., Maher, M. M., & Shanahan, F. (2008) · Gastroenterology · doi:10.1016/s0016-5085(08)60102-x · Cited by 307
Self-citationStrauss, K. J., Goske, M. J., Kaste, S. C., Bulas, D., Frush, D. P., Butler, P., Morrison, G., Callahan, M. J., & Applegate, K. E. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4091 · Cited by 305
Lehnert, B. E., & Bree, R. L. (2010) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2009.11.010 · Cited by 303
on behalf of the OPTIMA study group, van Randen, A., Laméris, W., van Es, H. W., van Heesewijk, H. P. M., van Ramshorst, B., ten Hove, W., Bouma, W. H., van Leeuwen, M. S., van Keulen, E. M., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2087-5 · Cited by 300
Negative Appendectomy Rate in the Era of CT: An 18-year Perspective
Raja, A. S., Wright, C., Sodickson, A. D., Zane, R. D., Schiff, G. D., Hanson, R., Baeyens, P. F., & Khorasani, R. (2010) · Radiology · doi:10.1148/radiol.10091570 · Cited by 298
Sistrom, C. L., Dang, P. A., Weilburg, J. B., Dreyer, K. J., Rosenthal, D. I., & Thrall, J. H. (2009) · Radiology · doi:10.1148/radiol.2511081174 · Cited by 279
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton-Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
Automatic selection of tube potential for radiation dose reduction in CT: A general strategy
Yu, L., Li, H., Fletcher, J. G., & McCollough, C. H. (2010) · Medical Physics · doi:10.1118/1.3264614 · Cited by 230
Rosen, M. P., Sands, D. Z., Longmaid, H. E., Reynolds, K. F., Wagner, M., & Raptopoulos, V. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.5.1741391 · Cited by 222
Tubiana, M. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.06.013 · Cited by 221
Radiation Exposures to Patients from CT: Reality, Public Perception, and Policy
Nickoloff, E. L., & Alderson, P. O. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770285 · Cited by 220
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217
Huang, W.-Y., Muo, C.-H., Lin, C.-Y., Jen, Y.-M., Yang, M.-H., Lin, J.-C., Sung, F.-C., & Kao, C.-H. (2014) · British Journal of Cancer · doi:10.1038/bjc.2014.103 · Cited by 213
Ginde, A. A., Foianini, A., Renner, D. M., Valley, M., & Camargo, Jr. (2008) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2008.00192.x · Cited by 197
Establishment of CT diagnostic reference levels in Ireland
Foley, S. J., McEntee, M. F., & Rainford, L. A. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15839549 · Cited by 186
Split-Bolus MDCT Urography with Synchronous Nephrographic and Excretory Phase Enhancement
Chow, L. C., Kwan, S. W., Olcott, E. W., & Sommer, G. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2288 · Cited by 185
A survey of awareness of radiation dose among health professionals in Northern Ireland
SOYE, J. A., & PATERSON, A. (2008) · The British Journal of Radiology · doi:10.1259/bjr/94101717 · Cited by 185
Multiple Diagnostic X-rays for Spine Deformities and Risk of Breast Cancer
Ronckers, C. M., Doody, M. M., Lonstein, J. E., Stovall, M., & Land, C. E. (2008) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-07-2628 · Cited by 176
Schauer, D. A., & Linton, O. W. (2009) · Radiology · doi:10.1148/radiol.2532090494 · Cited by 171
Flohr, T. G., Leng, S., Yu, L., Allmendinger, T., Bruder, H., Petersilka, M., Eusemann, C. D., Stierstorfer, K., Schmidt, B., & McCollough, C. H. (2009) · Medical Physics · doi:10.1118/1.3259739 · Cited by 167
Patient Radiation Dose at CT Urography and Conventional Urography
Nawfel, R. D., Judy, P. F., Schleipman, A. R., & Silverman, S. G. (2004) · Radiology · doi:10.1148/radiol.2321030222 · Cited by 163
Editorial: FOUNDATIONS AND FUNDAMENTALS
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2008.08.001 · Cited by 157
Radiation Effective Doses to Patients Undergoing Abdominal CT Examinations
Ware, D. E., Huda, W., Mergo, P. J., & Litwiller, A. L. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr05645 · Cited by 153
What are the risks from medical X-rays and other low dose radiation?
Wall, B. F., Kendall, G. M., Edwards, A. A., Bouffler, S. D., Muirhead, C. R., & Meara, J. R. (2006) · British Journal of Radiology · doi:10.1259/bjr/55733882 · Cited by 153
Radiology Order Entry With Decision Support: Initial Clinical Experience
Rosenthal, D. I., Weilburg, J. B., Schultz, T., Miller, J. C., Nixon, V. L., Dreyer, K. J., & Thrall, J. H. (2006) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2006.05.006 · Cited by 152
Leung, A. N., Bull, T. M., Jaeschke, R., Lockwood, C. J., Boiselle, P. M., Hurwitz, L. M., James, A. H., McCullough, L. B., Menda, Y., Paidas, M. J., et al. (2012) · Radiology · doi:10.1148/radiol.11114045 · Cited by 144
Cognitive function and prenatal exposure to ionizing radiation
Schull, W. J., & Ôtake, M. (1999) · Teratology · doi:10.1002/(sici)1096-9926(199904)59:4<222::aid-tera6>3.0.co;2-m · Cited by 141
Baumann, B. M., Chen, E. H., Mills, A. M., et al. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.10.018 · Cited by 138
Informing Parents About CT Radiation Exposure in Children: It's OK to Tell Them
Larson, D. B., Rader, S. B., Forman, H. P., & Fenton, L. Z. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2248 · Cited by 134
The Chernobyl Disaster: Cancer following the Accident at the Chernobyl Nuclear Power Plant
HATCH, M. C., Ron, E., Bouville, A. C., Zablotska, L. B., & Howe, G. R. (2005) · Epidemiologic Reviews · doi:10.1093/epirev/mxi012 · Cited by 131
Radiation Doses and Risks in Chest Computed Tomography Examinations
Huda, W. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200611-172ht · Cited by 131
Stein, S. C., Fabbri, A., Servadei, F., & Glick, H. A. (2008) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2008.01.002 · Cited by 128
Krille, L., Hammer, G. P., Merzenich, H., & Zeeb, H. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.08.025 · Cited by 126
Tsapaki, V., Ahmed, N. A., AlSuwaidi, J. S., Beganović, A., Benider, A., Omrane, L. B., Borisova, R. I., Economides, S., El-Nachef, L., Faj, D., et al. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2115 · Cited by 121
Dauer, L. T., Thornton, R. H., Miller, D. L., Damilakis, J. E., Dixon, R. G., Marx, M. V., Schueler, B. A., Vano, E., Venkatesan, A. M., Bartal, G., et al. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.09.007 · Cited by 120
Mendrik, A. M., Vonken, E.-J. P. A., Rutten, A., Viergever, M. A., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2022368 · Cited by 116
Linear No-Threshold Model vs. Radiation Hormesis
Doss, M. (2013) · Dose-Response · doi:10.2203/dose-response.13-005.doss · Cited by 115
Impact of Reduced Patient Life Expectancy on Potential Cancer Risks from Radiologic Imaging
Brenner, D. J., Shuryak, I., & Einstein, A. J. (2011) · Radiology · doi:10.1148/radiol.11102452 · Cited by 114
Little, M. P., & Boice, J. D. (1999) · Radiation Research · doi:10.2307/3579773 · Cited by 113
The use of helical computed tomography in pregnancy for the diagnosis of acute appendicitis
Castro, M. A., SHIPP, T. D., Castro, E. E., Ouzounian, J. G., & Rao, P. M. (2001) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2001.111721 · Cited by 112
Diagnostic reference levels from the ACR CT accreditation program
McCollough, C., Branham, T., Herlihy, V., Bhargavan, M., Robbins, L., Bush, K., McNitt-Gray, M., Payne, J. T., Ruckdeschel, T., Pfeiffer, D., et al. (2011) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2011.03.014 · Cited by 98
Yamazaki, J. N., & Schull, W. J. (1990) · PubMed · Cited by 96
CT DOSE: HOW TO MEASURE, HOW TO REDUCE
McCollough, C. H. (2008) · Health Physics · doi:10.1097/01.hp.0000326343.35884.03 · Cited by 95
O’Connor, O. J., Vandeleur, M., McGarrigle, A. M., Moore, N., McWilliams, S., McSweeney, S. E., O‘Neill, M. F., Chróinín, M. N., & Maher, M. M. (2010) · Radiology · doi:10.1148/radiol.10100278 · Cited by 90
Self-citationRice, H. E., Frush, D. P., Harker, M. J., Farmer, D. L., & Waldhausen, J. H. T. (2007) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2007.02.007 · Cited by 87
Potential Impact of the American College of Radiology Appropriateness Criteria on CT for Trauma
Hadley, J. L., Agola, J., & Wong, P. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0041 · Cited by 86
Keijzers, G., & Britton, C. J. (2010) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2010.tb03998.x · Cited by 84
Flint-Richter, P., & Sadetzki, S. (2007) · The Lancet Oncology · doi:10.1016/s1470-2045(07)70107-9 · Cited by 80
O’Sullivan, J., O’Connor, O. J., O'Regan, K. N., Clarke, B., Burgoyne, L. N., Ryan, M. F., & Maher, M. M. (2010) · Insights into Imaging · doi:10.1007/s13244-010-0009-8 · Cited by 79
Self-citationEffects of Low Level Radiation—What's New?
Royal, H. D. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.05.006 · Cited by 77
Radiation Safety Knowledge and Perceptions among Residents
Sadigh, G., Khan, R. N., Kassin, M. T., & Applegate, K. E. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.01.016 · Cited by 72
Vassileva, J., Rehani, M. M., Applegate, K. E., Ahmed, N. A., Al-Dhuhli, H., AlNaemi, H., Suwaidi, J. S. A., Arandjic, D., Beganović, A., Benavente, T., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2639-3 · Cited by 72
Kim, S. Y., Lee, K. H., Kim, K., Kim, T., Lee, H. S., Hwang, S.-S., Song, K., Kang, H. S., Kim, Y. H., & Rhee, J. E. (2011) · Radiology · doi:10.1148/radiol.11102247 · Cited by 69
Kim, K. P., Berrington de Gonzalez, A., Pearce, M. S., Salotti, J. A., Parker, L., McHugh, K., Craft, A. W., & Lee, C. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr429 · Cited by 66
Image Gently: A Campaign to Reduce Children's and Adolescents' Risk for Cancer During Adulthood
Applegate, K. E., & Cost, N. G. (2013) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2013.03.006 · Cited by 65
Invited article: Helical/spiral CT scanning: a pediatric radiology perspective
White, K. S. (1996) · Pediatric Radiology · doi:10.1007/bf01403695 · Cited by 62
Volume‐of‐interest (VOI) imaging in C‐arm flat‐detector CT for high image quality at reduced dose
Kolditz, D., Kyriakou, Y., & Kalender, W. A. (2010) · Medical Physics · doi:10.1118/1.3427641 · Cited by 62
The value of ultrafast computed tomography in the investigation of pediatric chest disease
Coren, M., Ng, V., Rubens, M. B., Rosenthal, M., & Bush, A. (1998) · Pediatric Pulmonology · Cited by 58
Image Gently, Step Lightly: Promoting Radiation Safety in Pediatric Interventional Radiology
Sidhu, M. K., Goske, M. J., Connolly, B. L., Racadio, J. M., Yoshizumi, T. T., Strauss, K. J., Coley, B. D., & Utley, T. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3938 · Cited by 57
Brisse, H. J., Robilliard, M., Savignoni, A., Pierrat, N., Gaboriaud, G., Rycke, Y. D., Neuenschwander, S., Aubert, B., & Rosenwald, J. (2009) · Health Physics · doi:10.1097/hp.0b013e3181ad00ed · Cited by 46
Second Thoughts About CT Imaging
Schenkman, L. (2011) · Science · doi:10.1126/science.331.6020.1002 · Cited by 43
Wagner, L., & Huda, W. (2004) · Pediatric Radiology · doi:10.1007/s00247-004-1206-8 · Cited by 34
Shifting the Paradigm in Radiation Safety
Doss, M. (2012) · Dose-Response · doi:10.2203/dose-response.11-056.doss · Cited by 32
CT utilization: the emergency department perspective
Broder, J. S. (2008) · Pediatric Radiology · doi:10.1007/s00247-008-0892-z · Cited by 31
Personalized Technologist Dose Audit Feedback for Reducing Patient Radiation Exposure From CT
Miglioretti, D. L., Zhang, Y., Johnson, E., Lee, C., Morin, R. L., Vanneman, N., & Smith‐Bindman, R. (2014) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2013.10.017 · Cited by 16
Responsible Use of CT [letter]
Frush, D. P. (2003) · Radiology · doi:10.1148/radiol.2291030373 · Cited by 16
Rodrigues, J. C. L., Negus, I. S., Manghat, N. E., & Hamilton, M. C. K. (2013) · Clinical Radiology · doi:10.1016/j.crad.2012.11.016 · Cited by 11
Evaluating Outcomes of Labor Inductions Beyond 39 Weeks of Gestation
Johnson, A. M., Bellerose, L., Billstrom, R., Deckers, E. A., & Beller, P. (2014) · Obstetrics and Gynecology · doi:10.1097/01.aog.0000447356.77081.e5 · Cited by 10
Cited by
TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images
Wasserthal, J., Breit, H.-C., Meyer, M. T., Pradella, M., Hinck, D., Sauter, A. W., Heye, T., Boll, D. T., Cyriac, J., Yang, S., et al. (2023) · Radiology: Artificial Intelligence · doi:10.1148/ryai.230024 · Cited by 1,657
Magnetic Nanoparticles in Cancer Therapy and Diagnosis
Farzin, A., Etesami, S. A., Quint, J., Memic, A., & Tamayol, A. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901058 · Cited by 562
Naghavi, M., Reeves, A. P., Atlas, K., Zhang, C., Atlas, T., Henschke, C. I., Yankelevitz, D. F., Budoff, M. J., Li, D., Roy, S. K., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01308-0 · Cited by 45
Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
Bouchareb, Y., Al-Maimani, A., Al-Balushi, A.-Y., Al-Kalbani, M., Al-Maskari, H., Al-Dhuhli, H., & Al-Kindi, F. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad225 · Cited by 7
Al Ewaidat, H., Balawi, S., Bataineh, Z., Al‐Dwairi, A., Al‐Khalily, M., Azez, K. A., & Almakhadmeh, A. (2023) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22855 · Cited by 4
Metadata
- Authors
- Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M.
- Venue
- World Journal of Radiology
- Publisher
- Baishideng Publishing Group Inc.
- Published
- 2016
- Volume
- 8
- Issue
- 12
- Pages
- 902
- ISSN
- 1949-8470 (ISSN-L)
- OpenAlex
- W2562439620
- Cited by
- 335
- References
- 112
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.