Human Thermoregulation and Measurement of Body Temperature in Exercise and Clinical Settings
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
This review discusses human thermoregulation during exercise and the measurement of body temperature in clinical and exercise settings. The thermoregulatory mechanisms play important roles in maintaining physiological homeostasis during rest and physical exercise. Physical exertion poses a challenge to thermoregulation by causing a substantial increase in metabolic heat production. However, within a non-thermolytic range, the thermoregulatory mechanisms are capable of adapting to sustain physiological functions under these conditions. The central nervous system may also rely on hyperthermia to protect the body from “overheating.” Hyperthermia may serve as a self-limiting signal that triggers central inhibition of exercise performance when a temperature threshold is achieved. Exposure to sub-lethal heat stress may also confer tolerance against higher doses of heat stress by inducing the production of heat shock proteins, which protect cells against the thermolytic effects of heat. Advances in body temperature measurement also contribute to research in thermoregulation. Current evidence supports the use of oral temperature measurement in the clinical setting, although it may not be as convenient as tympanic temperature measurement using the infrared temperature scanner. Rectal and oesophagus temperatures are widely accepted surrogate measurements of core temperature (Tc), but they cause discomfort and are less likely to be accepted by users. Gastrointestinal temperature measurement using the ingestible temperature sensor provides an acceptable level of accuracy as a surrogate measure of Tc without causing discomfort to the user. This form of Tc measurement also allows Tc to be measured continuously in the field and has gained wider acceptance in the last decade. Key words: Core temperature, Gastrointestinal temperature, Ingestible temperature sensor, Thermoregulation
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindquist, S., & Craig, E. A. (1988) · Annual Review of Genetics · doi:10.1146/annurev.ge.22.120188.003215 · Cited by 5,284
American College of Sports Medicine position stand
Otis, C. L. (1997) · Medical Entomology and Zoology · Cited by 4,407
Bouchama, A., & Knochel, J. P. (2002) · New England Journal of Medicine · doi:10.1056/nejmra011089 · Cited by 1,898
Influence of body temperature on the development of fatigue during prolonged exercise in the heat
González-Alonso, J., Teller, C., Andersen, S. L., Jensen, F. B., Hyldig, T., & Nielsen, B. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.3.1032 · Cited by 1,129
Craig, E. A., & Schlesinger, M. J. (1985) · Critical Reviews in Biochemistry · doi:10.3109/10409238509085135 · Cited by 801
Li, G. C., & Werb, Z. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.10.3218 · Cited by 735
Stress protein systems of mammalian cells
Subjeck, J. R., & Shyy, T. T. (1986) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1986.250.1.c1 · Cited by 557
Byrne, C., & Lim, C. L. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.026344 · Cited by 456
Self-citationRectal temperatures, weight losses, and sweat rates in marathon running.
Pugh, L. G., Corbett, J. L., & Johnson, R. H. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.347 · Cited by 316
Core Temperature Measurement: Methods and Current Insights
Moran, D. S., & Mendal, L. (2002) · Sports Medicine · doi:10.2165/00007256-200232140-00001 · Cited by 275
Cerebral Changes During Exercise in the Heat
Nielsen, B., & Nybo, L. (2003) · Sports Medicine · doi:10.2165/00007256-200333010-00001 · Cited by 236
Telemetry pill measurement of core temperature in humans during active heating and cooling
O'BRIEN, C., HOYT, R. W., BULLER, M. J., CASTELLANI, J. W., & YOUNG, A. J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199803000-00020 · Cited by 219
Field and clinical observations of exertional heat stroke patients
SHAPIRO, Y., & SEIDMAN, D. S. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199002000-00003 · Cited by 207
Specific protection from phenocopy induction by heat shock
Mitchell, H. K., Moller, G., Petersen, N. S., & Lipps‐Sarmiento, L. (1979) · Developmental Genetics · doi:10.1002/dvg.1020010206 · Cited by 200
Continuous Thermoregulatory Responses to Mass-Participation Distance Running in Heat
BYRNE, C., LEE, J. K. W., CHEW, S. A. N., LIM, C. L., & TAN, E. Y. M. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000218134.74238.6a · Cited by 196
Self-citationThe Effect of Cool Water Ingestion on Gastrointestinal Pill Temperature
WILKINSON, D. M., CARTER, J. M., RICHMOND, V. L., BLACKER, S. D., & RAYSON, M. P. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815cc43e · Cited by 195
Lim, C. L., & Mackinnon, L. T. (2006) · Sports Medicine · doi:10.2165/00007256-200636010-00004 · Cited by 176
Self-citationValidation of a new telemetric core temperature monitor
McKenzie, J. E., & Osgood, D. W. (2004) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2004.08.020 · Cited by 165
Thermometry in paediatric practice
El-Radhi, A. S. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088831 · Cited by 160
SPECULATIONS ON THE ORIGINS AND EVOLUTION OF PHOTOSYNTHESIS
Granick, S. (1957) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1957.tb49665.x · Cited by 155
McMurray, R. G., Lamb, D. R., & GISOLFI, C. V. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199306000-00020 · Cited by 147
Metabolic rate, not percent dehydration, predicts rectal temperature in marathon runners
NOAKES, T. D., MYBURGH, K. H., PLESSIS, J. D., LANG, L., LAMBERT, M., VAN DER RIET, C., & SCHALL, R. (1991) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199104000-00009 · Cited by 128
Temperature measurement in term and preterm neonates
Mayfield, S., Bhatia, J., Nakamura, K. T., Rios, G. R., & Bell, E. F. (1984) · The Journal of Pediatrics · doi:10.1016/s0022-3476(84)81011-2 · Cited by 127
Lee, S. M. C., Williams, W. J., & Schneider, S. M. (2000) · PubMed · Cited by 103
Thermotolerance in Mammalian Cells: A Possible Role for Heat Shock Proteins
Li, G. C., & Laszlo, A. (1985) · Elsevier eBooks · doi:10.1016/b978-0-12-066290-6.50017-6 · Cited by 103
Cattaneo, C. G., Frank, S. M., Hesel, T. W., El-Rahmany, H. K., Kim, L. J., & Tran, K. M. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200004000-00030 · Cited by 98
Axillary temperature as a screening test for fever in children
Kresch, M. J. (1984) · The Journal of Pediatrics · doi:10.1016/s0022-3476(84)80558-2 · Cited by 84
Couch, R. B. (1984) · Journal of Infectious Diseases · doi:10.1093/infdis/150.2.167 · Cited by 83
Nimmo, M. A. (2004) · Journal of Sports Sciences · doi:10.1080/0264041400005883 · Cited by 78
HEAT STROKE AND HYPERTHERMIA IN MARATHON RUNNERS
Wyndham, C. H. (1977) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1977.tb38192.x · Cited by 78
The Hot Brain: Survival, Temperature, and the Human Body
GISOLFI, C. V., & Mora, F. (2000) · Cited by 76
Temperature measurement: comparison of non‐invasive methods used in adult critical care
Farnell, S., Maxwell, L., Tan, S. S., Rhodes, A., & Philips, B. J. (2005) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2004.00916.x · Cited by 76
The effect of exercise training on the severity and duration of a viral upper respiratory illness
Weidner, T. G., Cranston, T. E., SCHURR, T., & Kaminsky, L. A. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199811000-00004 · Cited by 74
Accuracy of an Infrared Tympanic Thermometer
Amoateng-Adjepong, Y., Del Mundo, J., & Manthous, C. A. (1999) · Chest · doi:10.1378/chest.115.4.1002 · Cited by 72
Use of an ingestible telemetry sensor to measure core temperature under chemical protective clothing
Kolka, M. A., Levine, L., & Stephenson, L. A. (1997) · Journal of Thermal Biology · doi:10.1016/s0306-4565(97)00032-6 · Cited by 61
OUTBREAK OF SALMONELLA EIMSBUETTEL IN NEWBORN INFANTS SPREAD BY RECTAL THERMOMETERS
McAllister, T. A., Marshall, A., Roud, J. A., Holland, B. M., & Turner, T. L. (1986) · The Lancet · doi:10.1016/s0140-6736(86)91397-8 · Cited by 60
Muller, A. W. J. (1995) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(95)00004-7 · Cited by 59
An Evaluation of Body Temperature Measurement
Ilsley, A. H., Rutten, A. J., & Runciman, W. B. (1983) · Anaesthesia and Intensive Care · doi:10.1177/0310057x8301100107 · Cited by 55
When body temperature changes, does rectal temperature lag?
Greenes, D. S., & FLEISHER, G. R. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.02.037 · Cited by 52
Heat injuries in Canadian mass participation runs.
Hughson, R. L., Green, H. J., Houston, M. E., Thomson, J. A., MacLean, D. R., & Sutton, J. R. (1980) · PubMed Central · Cited by 51
Infrared ear thermometers—parameters influencing their reading and accuracy
Pušnik, I., & Drnovšek, J. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/016 · Cited by 39
Lim, C. L., Chung, K. K., & Hock, L. L. K. (1997) · Military Medicine · doi:10.1093/milmed/162.9.623 · Cited by 37
Self-citationEnvironment and Human Performance
Haymes, E. M., & Wells, C. L. (1986) · Medical Entomology and Zoology · Cited by 36
Weidner, T. G., Anderson, B. N., Kaminsky, L. A., Dick, E. C., & SCHURR, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199705000-00003 · Cited by 33
[Central regulation of body temperature].
Nakayama, A. (1972) · PubMed · Cited by 32
The falling grace of axillary temperatures.
Haddock, B. J., Merrow, D. L., & Swanson, M. S. (1996) · PubMed · Cited by 30
Fluid Balance for Optimal Performance
GISOLFI, C. V. (2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.1996.tb03912.x · Cited by 25
Need for a reliable system to measure body temperature
Rupp, M. E., Heermann, J. A., & Uphoff, M. E. (2004) · American Journal of Infection Control · doi:10.1016/j.ajic.2003.06.005 · Cited by 4
Cited by
Physiological Parameters for Oral Delivery and in Vitro Testing
Mudie, D. M., Amidon, G. L., & Amidon, G. E. (2010) · Molecular Pharmaceutics · doi:10.1021/mp100149j · Cited by 490
Asmundson, G. J. G., Fetzner, M. G., DeBoer, L. B., Powers, M. B., Otto, M. W., & Smits, J. A. J. (2013) · Depression and Anxiety · doi:10.1002/da.22043 · Cited by 361
“Thermoregulatory mechanisms are known to influence homeostasis, which becomes threatened during physiological arousal (for reviews see[60, 61]).”
BackgroundWearable and flexible sensors for user-interactive health-monitoring devices
Ha, M., Lim, S., & Ko, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb01063c · Cited by 352
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Fever, fever patterns and diseases called “fever”—A review
Ogoina, D. (2011) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2011.05.002 · Cited by 305
Metadata
- Authors
- Lim, C. L., Byrne, C., & Lee, J. K.
- Venue
- Annals of the Academy of Medicine, Singapore
- Publisher
- Academy of Medicine, Singapore
- Published
- 2008-04-15
- Volume
- 37
- Issue
- 4
- Pages
- 347-353
- ISSN
- 0304-4602 (ISSN-L)
- OpenAlex
- W2164446273
- Cited by
- 373
- References
- 48
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.