The DOI matches its Crossref record.
Towards Steering Magnetic Nanoparticles in Drug Targeting Using a Linear Halbach Array
Open accessPublished version of a preprint
Abstract
Magnetic nanoparticles offer numerous promising biomedical applications, e.g. magnetic drug targeting. Here, magnetic drug carriers inside the human body are directed towards tumorous tissue by an external magnetic field. However, the success of the treatment strongly depends on the amount of drug carriers, reaching the desired tumor region. This steering process is still an open research topic. In this paper, the previous study of a linear Halbach array is extended by an additional Halbach array with different magnetization angles between two adjacent magnets and investigated numerically using COMSOL Multiphysics. The Halbach arrays are arranged with permanent magnets and generate a relatively large region of a moderately homogeneous, high magnetic field while having a strong gradient. This results in a strong magnetic force, trapping many particles at the magnets. Afterwards, to avoid particle agglomeration, the Halbach array is flipped to its weak side. Therefore, the magnetic flux density, its gradient and the resulting magnetic force are computed for the different Halbach arrays with different constellations of magnetization directions. Since the calculation of the gradient can lead to high errors due to the used mesh in Comsol, the gradient was derived analytically by investigating two different fitting functions. Overall, the array with a 90 ∘ shifted magnetization performs best, changing the magnetic sides of the array easily and deflecting more particles. Besides, the results revealed that the magnetic force dominates directly underneath the magnets compared to the other existing forces on the SPIONS. Summarized, the results depict that the magnetic force and, thus, the region where the particles are able to get washed out, can be adjusted using low-cost permanent magnets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Halbach arrays generate the strongest magnetic force over a large distance.
“In the literature, so-called Halbach arrays have proven to be particularly suitable for particle steering, as they generate the strongest magnetic force over a large distance [7][8][9].”
From Experimental and Simulative Analysis of Magnetic Nanoparticle Accumulation Using Various Halbach Arrays (2024) · cites this paper as [7]
Section 2.1 reports stronger magnetic force from a linear Halbach array than from an alternating-magnetization array. Section 3.3 says the gradient on its strong side remains high over a larger distance, but does not establish that Halbach arrays generate the strongest magnetic force over a large distance compared with other configurations. Page numbers are unavailable in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 32
- Alexiou, C., Diehl, D., Henninger, P., Iro, H., Rockelein, R., Schmidt, W., and Weber, H.: A High Field Gradient Magnet for Magnetic Drug Targeting, IEEE T. Appl. Supercon., 16, 1527–1530, 10.1109/TASC.2005.864457, 2006. · DOI
- Alnaimat, F., Karam, S., Mathew, B., and Mathew, B.: Magnetophoresis and Microfluidics: A Great Union, IEEE Nanotechnol. Mag., 14, 24–41, 10.1109/MNANO.2020.2966029, 2020. · DOI
- Baun, O. and Blümler, P.: Permanent magnet system to guide superparamagnetic particles, J. Magn. Magn. Mater., 439, 294–304, 10.1016/j.jmmm.2017.05.001, 2017. · DOI
- Bjørk, R. and Insinga, A. R.: A topology optimized switchable permanent magnet system, J. Magn. Magn. Mater., 465, 106–113, 10.1016/j.jmmm.2018.05.076, 2018. · DOI
- Bjørk, R., Bahl, C., Smith, A., and Pryds, N.: Comparison of adjustable permanent magnetic field sources, J. Magn. Magn. Mater., 322, 3664–3671, 10.1016/j.jmmm.2010.07.022, 2010. · DOI
- Blümler, P.: Magnetic Guiding with Permanent Magnets: Concept, Realization and Applications to Nanoparticles and Cells, Cells, 10, 2708, 10.3390/cells10102708, 2021. · DOI
- Cullity, B. D. and Graham, C. D.: Introduction to Magnetic Materials, 1st edn., John Wiley & Sons, Inc, Hoboken, NJ, USA, 10.1002/9780470386323, 2008. · DOI
- Fink, M., Rupitsch, S. J., Lyer, S., and Ermert, H.: Quantitative Determination of Local Density of Iron Oxide Nanoparticles Used for Drug Targeting Employing Inverse Magnetomotive Ultrasound, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 68, 2482–2495, 10.1109/TUFFC.2021.3068791, 2021. · DOI
- Hilton, J. E. and McMurry, S. M.: An adjustable linear Halbach array, J. Magn. Magn. Mater., 324, 2051–2056, 10.1016/j.jmmm.2012.02.014, 2012. · DOI · Paper page
- Hoshiar, A. K., Le, T.-A., Amin, F. U., Kim, M. O., and Yoon, J.: Studies of aggregated nanoparticles steering during magnetic-guided drug delivery in the blood vessels, J. Magn. Magn. Mater., 427, 181–187, 10.1016/j.jmmm.2016.11.016, 2017. · DOI
- Ijiri, Y., Poudel, C., Williams, P. S., Moore, L. R., Orita, T., and Zborowski, M.: Inverted Linear Halbach Array for Separation of Magnetic Nanoparticles, IEEE T. Magn., 49, 3449–3452, 10.1109/TMAG.2013.2244577, 2013. · DOI
- Jackson, J. D.: Classical electrodynamics, 3rd edn., John Wiley & Sons, New York, USA, ISBN 978-0-47130-932-1, 1998.
- Kang, J. H., Driscoll, H., Super, M., and Ingber, D. E.: Application of a Halbach magnetic array for long-range cell and particle separations in biological samples, Appl. Phys. Lett., 108, 213702, 10.1063/1.4952612, 2016. · DOI · Paper page
- Kim, Y., Chae, J. K., Lee, J.-H., Choi, E., Lee, Y. K., and Song, J.: Free manipulation system for nanorobot cluster based on complicated multi-coil electromagnetic actuator, IEEE T. Magn., 43, 2956–2958, 10.1109/TMAG.2007.893798, 2021. · DOI
- Mues, B., Bauer, B., Roeth, A. A., Ortega, J., Buhl, E. M., Radon, P., Wiekhorst, F., Gries, T., Schmitz-Rode, T., and Slabu, I.: Nanomagnetic Actuation of Hybrid Stents for Hyperthermia Treatment of Hollow Organ Tumors, Nanomaterials-Basel, 11, 618, 10.3390/nano11030618, 2021. · DOI
- Myrovali, E., Papadopoulos, K., Iglesias, I., Spasova, M., Farle, M., Wiedwald, U., and Angelakeris, M.: Long-Range Ordering Effects in Magnetic Nanoparticles, ACS Appl. Mater. Inter., 13, 21602–21612, 10.1021/acsami.1c01820, 2021. · DOI
- Nacev, A., Komaee, A., Sarwar, A., Probst, R., Kim, S. H., Emmert-Buck, M., and Shapiro, B.: Towards Control of Magnetic Fluids in Patients: Directing Therapeutic Nanoparticles to Disease Locations, IEEE Contr. Syst. Mag., 32, 32–74, 10.1109/MCS.2012.2189052, 2012. · DOI
- Park, M., Le, T.-A., Eizad, A., and Yoon, J.: A Novel Shared Guidance Scheme for Intelligent Haptic Interaction Based Swarm Control of Magnetic Nanoparticles in Blood Vessels, IEEE Access, 8, 106714–106725, 10.1109/ACCESS.2020.3000329, 2020. · DOI
- Peng, J. and Zhou, Y.: Modeling and Analysis of a New 2-D Halbach Array for Magnetically Levitated Planar Motor, IEEE T. Magn., 49, 618–627, 10.1109/TMAG.2012.2210435, 2013. · DOI
- Sakuma, H. and Nakagawara, T.: Optimization of rotation patterns of a mangle-type magnetic field source using covariance matrix adaptation evolution strategy, J. Magn. Magn. Mater., 527, 167752, 10.1016/j.jmmm.2021.167752, 2021. · DOI · Paper page
- Shen, Y. and Zhu, Z.-Q.: General analytical model for calculating electromagnetic performance of permanent magnet brushless machines having segmented Halbach array, IET Electr. Syst. Transp., 3, 57–66, 10.1049/iet-est.2012.0055, 2013. · DOI
- Shiriny, A. and Bayareh, M.: On magnetophoretic separation of blood cells using Halbach array of magnets, Meccanica, 55, 1903–1916, 10.1007/s11012-020-01225-y, 2020. · DOI
- Sim, M.-S. and Ro, J.-S.: Semi-Analytical Modeling and Analysis of Halbach Array, Energies, 13, 1252, 10.3390/en13051252, 2020. · DOI
- Stevens, M., Liu, P., Niessink, T., Mentink, A., Abelmann, L., and Terstappen, L.: Optimal Halbach Configuration for Flow-through Immunomagnetic CTC Enrichment, Diagnostics, 11, 1020, 10.3390/diagnostics11061020, 2021. · DOI
- Thalmayer, A., Zeising, S., Fischer, G., and Kirchner, J.: Investigation of Particle Steering for Different Cylindrical Permanent Magnets in Magnetic Drug Targeting, in: Proceedings of 7th International Electronic Conference on Sensors and Applications (MDPI), Basel, Switzerland, 13–30 November 2020, p. 8269, 10.3390/ecsa-7-08269, 2020. · DOI
- Thalmayer, A. S., Zeising, S., Fischer, G., and Kirchner, J.: Steering Magnetic Nanoparticles by Utilizing an Adjustable Linear Halbach Array, in: 2021 Kleinheubach Conference, Miltenberg, Germany, 28–30 September 2021, 1–4, 10.23919/IEEECONF54431.2021.9598436, 2021. · DOI · Paper page
- Tietze, R., Lyer, S., Dürr, S., Struffert, T., Engelhorn, T., Schwarz, M., Eckert, E., Göen, T., Vasylyev, S., Peukert, W., Wiekhorst, F., Trahms, L., Dörfler, A., and Alexiou, C.: Efficient drug-delivery using magnetic nanoparticles–biodistribution and therapeutic effects in tumour bearing rabbits, Nanomed.-Nanotechnol., 9, 961–971, 10.1016/j.nano.2013.05.001, 2013. · DOI · Paper page
- Vogel, P., Kampf, T., Herz, S., Ruckert, M. A., Bley, T. A., and Behr, V. C.: Adjustable Hardware Lens for Traveling Wave Magnetic Particle Imaging, IEEE T. Magn., 56, 1–6, 10.1109/TMAG.2020.3023686, 2020. · DOI
- Wei, W. and Wang, Z.: Investigation of Magnetic Nanoparticle Motion under a Gradient Magnetic Field by an Electromagnet, J. Nanomater., 2018, 1–5, 10.1155/2018/6246917, 2018. · DOI
- Zaloga, J., Janko, C., Nowak, J., Matuszak, J., Knaup, S., Eberbeck, D., Tietze, R., Unterweger, H., Friedrich, R. P., Duerr, S., Heimke-Brinck, R., Baum, E., Cicha, I., Dörje, F., Odenbach, S., Lyer, S., Lee, G., and Alexiou, C.: Development of a lauric acid/albumin hybrid iron oxide nanoparticle system with improved biocompatibility, Int. J. Nanomed., 9, 4847–4866, 10.2147/IJN.S68539, 2014. · DOI
- Zhang, H. S., Deng, Z. X., Yang, M. L., Zhang, Y., Tuo, J. Y., and Xu, J.: Analytical Prediction of Halbach Array Permanent Magnet Machines Considering Finite Tooth Permeability, IEEE T. Magn., 56, 1–10, 10.1109/TMAG.2020.2982844, 2020. · DOI
- Zhang, X., Li, Y. G., Cheng, H., and Liu, H. K.: Analysis of the Planar Magnetic Field of Linear Permanent Magnet Halbach Array, Appl. Mech. Mater., 66–68, 1336–1341, 10.4028/www.scientific.net/AMM.66-68.1336, 2011. · DOI
Cited by
Sorted by citations
Thalmayer, A. S., Götz, K., Lübke, M., & Fischer, G. (2024) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2024-2159
Self-citation
Metadata
- Authors
- Thalmayer, A. S., Zeising, S., Lübke, M., & Fischer, G.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Corresponding author
- Thalmayer, Angelika S.
- Zeising, Samuel
- Lübke, Maximilian
- Fischer, Georg
- Venue
- Advances in Radio Science
- Publisher
- Copernicus GmbH
- Published
- 2023-03-21
- Volume
- 20
- Issue
- 0
- Pages
- 93-104
- ISSN
- 1684-9965 (ISSN-L)
- 1684-9973
- OpenAlex
- W4328130045
- Cited by
- 12
- References
- 0
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 3 · 2023: 4
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Advances in radio science (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
- Keywords
- magnetic nanoparticles, magnetic drug delivery, Halbach array, permanent magnets, magnetic force, superparamagnetic iron oxide nanoparticles, magnetization angle, particle agglomeration, tumor targeting, magnetic field homogeneity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review