CoChat

Air Leak is Associated with Poor Adherence to Autopap Therapy

Open access
Valentin, Alexandra, Subramanian, Shyam, Quan, Stuart F., Berry, Richard B., Parthasarathy, Sairam · 2011 · Sleep
Cited by 96

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: To our knowledge, a systematic study of the effect of air leak on adherence to auto-titrating positive airway pressure (autoPAP) therapy has not been reported. We hypothesized that in patients with obstructive sleep apnea (OSA), greater levels of air leak were associated with poor adherence to autoPAP therapy. DESIGN: Retrospective cohort study SETTING: Academic Center PARTICIPANTS: Ninety-six consecutive patients with high probability for OSA. INTERVENTIONS: N/A. MEASUREMENTS: Patients with OSA received 1 week of autoPAP therapy following which both adherence data and air leak information was downloaded from the device. Continuous positive airway pressure (CPAP) therapy was issued for a 5-week period with pressure determined by 90th percentile of that delivered during autoPAP therapy. Adequate adherence was defined as average usage > 4 h per night on all nights. RESULTS: Forty-three patients were adherent to autoPAP therapy (350 ± 67[SD] min/day), whereas 53 patients were not (122 ± 65 min/day; P < 0.0001). Air leak that was adjusted for pressure delivered was greater in non-adherent patients (7.0 ± 3.5 L/min/cm H(2)O) than that in adherent patients (4.9 ± 1.7 L/min/cm H(2)O; P < 0.0001). Greater residual respiratory events (measured as autoPAP-derived hypopnea index) and proportion of time spent at large leak levels were associated with non-adherence. Patients who were adherent to autoPAP therapy received higher average therapeutic pressures from the autoPAP device than non-adherent patients. Multivariate logistic regression revealed that higher levels of air leak were associated with non-adherence to autoPAP therapy (odds ratio 1.43; 95% CI, 1.03, 1.98; P = 0.03). Moreover, adherence to autoPAP therapy was strongly correlated with subsequent adherence to CPAP therapy (R(2) = 0.74; P < 0.0001). CONCLUSION: Air leak was associated with poor adherence to autoPAP therapy. We speculate that air leak could be a potential target for future studies aimed at enhancing adherence to autoPAP therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.1054

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 96

Metadata

Authors
Valentin, A., Subramanian, S., Quan, S. F., Berry, R. B., & Parthasarathy, S.
Venue
Sleep
Published
2011-06
Volume
34
Issue
6
Pages
801-806
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2136113712
Cited by
96
References
11
FWCI
3.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.