Sleep Estimates Using Microelectromechanical Systems (MEMS)
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVES: Although currently more affordable than polysomnography, actigraphic sleep estimates have disadvantages. Brand-specific differences in data reduction impede pooling of data in large-scale cohorts and may not fully exploit movement information. Sleep estimate reliability might improve by advanced analyses of three-axial, linear accelerometry data sampled at a high rate, which is now feasible using microelectromechanical systems (MEMS). However, it might take some time before these analyses become available. To provide ongoing studies with backward compatibility while already switching from actigraphy to MEMS accelerometry, we designed and validated a method to transform accelerometry data into the traditional actigraphic movement counts, thus allowing for the use of validated algorithms to estimate sleep parameters. DESIGN: Simultaneous actigraphy and MEMS-accelerometry recording. SETTING: Home, unrestrained. PARTICIPANTS: Fifteen healthy adults (23-36 y, 10 males, 5 females). INTERVENTIONS: None. MEASUREMENTS: Actigraphic movement counts/15-sec and 50-Hz digitized MEMS-accelerometry. ANALYSES: Passing-Bablok regression optimized transformation of MEMS-accelerometry signals to movement counts. Kappa statistics calculated agreement between individual epochs scored as wake or sleep. Bland-Altman plots evaluated reliability of common sleep variables both between and within actigraphs and MEMS-accelerometers. RESULTS: Agreement between epochs was almost perfect at the low, medium, and high threshold (kappa = 0.87 ± 0.05, 0.85 ± 0.06, and 0.83 ± 0.07). Sleep parameter agreement was better between two MEMS-accelerometers or a MEMS-accelerometer and an actigraph than between two actigraphs. CONCLUSIONS: The algorithm allows for continuity of outcome parameters in ongoing actigraphy studies that consider switching to MEMS-accelerometers. Its implementation makes backward compatibility feasible, while collecting raw data that, in time, could provide better sleep estimates and promote cross-study data pooling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Mechanisms and functions of coupling between sleep and temperature rhythms
Van Someren, E. J. W. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)53018-3 · Cited by 209
Sleep propensity is modulated by circadian and behavior-induced changes in cutaneous temperature
Van Someren, E. J. W. (2004) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2004.08.003 · Cited by 98
van Someren, E. J. W., van Gool, W. A., Vonk, B. F. M., Mirmiran, M., Speelman, J. D., Bosch, D. A., & Swaab, D. F. (1993) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(93)90148-r · Cited by 56
Correlated Fluctuations of Daytime Skin Temperature and Vigilance
Romeijn, N., & Van Someren, E. J. W. (2011) · Journal of Biological Rhythms · doi:10.1177/0748730410391894 · Cited by 48
Cited by
A novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744
“Previously published methods for sleep detection using accelerometers optimized their parameters to best fit with polysomnography-derived periods of sleep [14,18].”
BackgroundMethodBrain mechanisms of insomnia: new perspectives on causes and consequences
Van Someren, E. J. W. (2021) · Physiological Reviews · doi:10.1152/physrev.00046.2019 · Cited by 543
Self-citationWalch, O., Huang, Y., Forger, D., & Goldstein, C. (2019) · Sleep · doi:10.1093/sleep/zsz180 · Cited by 240
“Three types of features were considered as inputs to the classification algorithms tested: motion (activity counts, converted from raw acceleration in m/s 2 using the method outlined in [34]), heart rate, and a “clock proxy” term representing simulated input to sleep from the circadian clock.”
MethodAlternatives to polysomnography (PSG): a validation of wrist actigraphy and a partial-PSG system
Kosmadopoulos, A., Sargent, C., Darwent, D., Zhou, X., & Roach, G. D. (2014) · Behavior Research Methods · doi:10.3758/s13428-013-0438-7 · Cited by 160
Automating sleep stage classification using wireless, wearable sensors
Boe, A. J., McGee Koch, L. L., O’Brien, M. K., Shawen, N., Rogers, J. A., Lieber, R. L., Reid, K. J., Zee, P. C., & Jayaraman, A. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0210-1 · Cited by 98
Metadata
- Authors
- te Lindert, B. H. W., & Van Someren, E. J. W.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-05-01
- Volume
- 36
- Issue
- 5
- Pages
- 781-789
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W332128417
- Cited by
- 139
- References
- 10
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sleep Estimates Using Microelectromechanical Systems (MEMS). https://app.cochat.ai/papers/10.5665/sleep.2648
- The paper
- te Lindert, B. H. W., & Van Someren, E. J. W. (2013). Sleep Estimates Using Microelectromechanical Systems (MEMS). Sleep. https://doi.org/10.5665/sleep.2648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.