The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Quantitative Magnetic Particle Imaging Monitors the Transplantation, Biodistribution, and Clearance of Stem Cells In Vivo
Open accessAbstract
Stem cell therapies have enormous potential for treating many debilitating diseases, including heart failure, stroke and traumatic brain injury. For maximal efficacy, these therapies require targeted cell delivery to specific tissues followed by successful cell engraftment. However, targeted delivery remains an open challenge. As one example, it is common for intravenous deliveries of mesenchymal stem cells (MSCs) to become entrapped in lung microvasculature instead of the target tissue. Hence, a robust, quantitative imaging method would be essential for developing efficacious cell therapies. Here we show that Magnetic Particle Imaging (MPI), a novel technique that directly images iron-oxide nanoparticle-tagged cells, can longitudinally monitor and quantify MSC administration in vivo. MPI offers near-ideal image contrast, depth penetration, and robustness; these properties make MPI both ultra-sensitive and linearly quantitative. Here, we imaged, for the first time, the dynamic trafficking of intravenous MSC administrations using MPI. Our results indicate that labeled MSC injections are immediately entrapped in lung tissue and then clear to the liver within one day, whereas standard iron oxide particle (Resovist) injections are immediately taken up by liver and spleen. Longitudinal MPI-CT imaging also indicated a clearance half-life of MSC iron oxide labels in the liver at 4.6 days. Finally, our ex vivo MPI biodistribution measurements of iron in liver, spleen, heart, and lungs after injection showed excellent agreement (R(2) = 0.943) with measurements from induction coupled plasma spectrometry. These results demonstrate that MPI offers strong utility for noninvasively imaging and quantifying the systemic distribution of cell therapies and other therapeutic agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,163
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Mesenchymal Stem Cell Homing: The Devil Is in the Details
Karp, J. M., & Leng Teo, G. S. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.02.001 · Cited by 1,445
Fischer, U. M., Harting, M. T., Jimenez, F., Monzon-Posadas, W. O., Xue, H., Savitz, S. I., Laine, G. A., & Cox, C. S. (2009) · Stem Cells and Development · doi:10.1089/scd.2008.0253 · Cited by 1,292
The Dynamic in vivo Distribution of Bone Marrow-Derived Mesenchymal Stem Cells after Infusion
Gao, J., Dennis, J. E., Muzic, R. F., Lundberg, M., & Caplan, A. I. (2001) · Cells Tissues Organs · doi:10.1159/000047856 · Cited by 952
Gupta, N., Su, X., Popov, B. V., Lee, J. W., Serikov, V. B., & Matthay, M. A. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.179.3.1855 · Cited by 933
Bone Marrow–Derived Mesenchymal Stem Cells in Repair of the Injured Lung
Rojas, M., Xu, J., Woods, C. R., Mora, A. L., Spears, W., Roman, J., & Brigham, K. L. (2005) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2004-0330oc · Cited by 849
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Eggenhofer, E., Benseler, V., Kroemer, A., Popp, F. C., Geissler, E. K., Schlitt, H. J., Baan, C. C., Dahlke, M. H., & Hoogduijn, M. J. (2012) · Frontiers in Immunology · doi:10.3389/fimmu.2012.00297 · Cited by 804
Schlomka, J., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 803
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–300 of 321
Makela, A. V., Gaudet, J. M., Murrell, D. H., Mansfield, J. R., Wintermark, M., & Contag, C. H. (2020) · Neuroscience · doi:10.1016/j.neuroscience.2020.10.036 · Cited by 9
Magnetic Particle Imaging for Vascular, Cellular and Molecular Imaging
Chandrasekharan, P., Tay, Z. W., Zhou, X. Y., Yu, E. Y., Fung, B. K., Colson, C., Fellows, B. D., Lu, Y., Huynh, Q., Saayujya, C., et al. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-816386-3.00015-6 · Cited by 9
Zheng, B., Lu, K., Konkle, J., Hensley, D. W., Keselman, P., Orendorff, R. D., Tay, Z. W., Yu, E. Y., Zhou, X. Y., Bishop, M. D., et al. (2016) · Springer eBooks · doi:10.1007/978-3-319-42169-8_4 · Cited by 8
Sequential Scan-Based High-Resolution 3-D Open-Sided Magnetic Particle Imaging System
He, J., Zhang, H., Lei, S., Li, G., Li, Y., Zhu, T., Qian, Z., Xiong, F., Feng, Y., An, Y., et al. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3396830 · Cited by 8
“It has been shown to offer high-resolution, high-sensitivity, and real-time imaging capabilities [2], [3], [4].”
BackgroundHe, J., Zhang, H., Li, Y., Li, G., Lei, S., Qian, Z., Xiong, F., Feng, Y., Zhu, T., An, Y., et al. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3404602 · Cited by 8
“Furthermore, the differing magnetization response of in vivo SPIONs and in vitro SPIONs poses a significant challenge in accurately quantifying SPION concentrations [19], [20].”
BackgroundSun, R., Wang, N., Zheng, S.-S., Wang, H., & Xie, H. (2024) · Transplantation · doi:10.1097/tp.0000000000004913 · Cited by 9
Wei, J. H., Sun, S., Xia, C., Ivanov, A. O., Elfimova, E. A., Yin, C., Cai, R., Sun, S., Xu, L., & Zhong, J. (2024) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-024-01312-1 · Cited by 8
Sehl, O. C., Yang, Y., Anjier, A., Nevozhay, D., Cheng, D., Guo, K., Fellows, B. D., Mohtasebzadeh, A. R., Mason, E. E., Sanders, T., et al. (2024) · Molecular Imaging and Biology · doi:10.1007/s11307-024-01969-z · Cited by 9
Cao, G., Zhang, R., Jia, X., Jiang, B., Li, Y., Xuan, X., Tian, J., Hui, H., Xin, S., & Dong, H. (2024) · Cardiovascular Research · doi:10.1093/cvr/cvae255 · Cited by 8
Multifunctional Magnetic Resonance Imaging Probes
Biegger, P., Ladd, M. E., & Komljenovic, D. (2020) · Recent results in cancer research/Recent Results in Cancer Research · doi:10.1007/978-3-030-42618-7_6 · Cited by 8
Zhang, B., Zhang, H., Gao, P., Hui, H., An, Y., & Tian, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3450917 · Cited by 8
“Its imaging principle relies on the generation of nonlinear magnetic response signals from superparamagnetic iron oxide nanoparticles (SPIONs), thus allowing for high-contrast imaging capability due to the absence of signals from biological tissue [2], [3].”
BackgroundMultihead Attention U‐Net for Magnetic Particle Imaging–Computed Tomography Image Segmentation
Juhong, A., Li, B., Liu, Y., Yang, C., Yao, C., Agnew, D., Lei, Y. L., Luker, G. D., Bumpers, H. L., Huang, X., et al. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400007 · Cited by 9
Pi, S., Liu, W., Wei, K., & Mosiniewicz-Szablewska, E. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2636805 · Cited by 8
“[9] has shown that there is no significant dependence of magnetic signal intensity on tissue depth in contrast to the exponential decrease of optical signal intensity with increasing tissue depth.”
BackgroundSobhani, T., Shahbazi‐Gahrouei, D., Zahraei, M., Hejazi, S. H., Dousti, F., & Rostami, M. R. (2022) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-022-04427-x · Cited by 8
Jiang, T., Pi, S., Shi, J., Zhang, P., Liu, W., & Cheng, J. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/ab2d40 · Cited by 8
Heidel, J. S., Fischer, A. G., Tang, X., Sadri, G., Wu, W., Moisa, C. R., Stowers, H. L., Sandella, N., Wysoczynski, M., Uchida, S., et al. (2020) · Theranostics · doi:10.7150/thno.41000 · Cited by 8
Development of Magnetic Particle Imaging (MPI) for Cell Tracking and DetectionPreprint
Melo, K. P., Makela, A. V., Knier, N. N., Hamilton, A. M., & Foster, P. J. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.07.12.197780 · Cited by 8
Thermal dose feedback control systems applied to magnetic nanoparticle hyperthermia
Lad, Y. S., Pawar, S., Arepally, N., Carlton, H., Hadjipanayis, C. G., Ivkov, R., Abu-Ayyad, M., & Attaluri, A. (2025) · International Journal of Hyperthermia · doi:10.1080/02656736.2025.2491519 · Cited by 7
Spatial Manipulation of Particles and Cells at Micro- and Nanoscale via Magnetic Forces
Panina, L. V., Gurevich, A., Beklemisheva, A. V., Omelyanchik, A. S., Levada, K. V., & Rodionova, V. V. (2022) · Vide Leaf, Hyderabad eBooks · doi:10.37247/pamolb2ed.2.22.11 · Cited by 7
Hu, X., Wang, Z., Zhu, Y., Li, Z., Yan, H., Zhao, L., & Wang, Q. (2025) · Nanoscale Advances · doi:10.1039/d4na01080a · Cited by 6
Río, C., Jahn, A. K., Martín-Medina, A., Bota, A. M. C., Casado, M. T. D. F., Antona, P. J. P., Gigirey, O., Carvajal, Á. F., Villena, C., Bellvert, C. G., et al. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24065813 · Cited by 6
Multifunctional Liposomes to Attain Targeting, Stimuli Sensitive Drug Release and Imaging Cancer
Kumar, V., Kewlani, P., Singh, A., Sanjay, Gautam, A. K., & Rajamanickam, V. M. (2023) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/978-981-99-6564-9_3 · Cited by 6
Chinchilla, C., McDonough, C., Negash, A., Pagan, J., & Tonyushkin, A. (2020) · International journal on magnetic particle imaging · doi:10.18416/ijmpi.2021.2104001 · Cited by 6
Lee, J.-Y., Sohn, H., Kim, C., Kim, T., & Lee, H. S. (2022) · Biomedicines · doi:10.3390/biomedicines10123223 · Cited by 6
Molecular imaging of cardiac regenerative medicine
Qin, X., Han, D., & Wu, J. C. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.04.006 · Cited by 6
Current Progress and Perspective: Clinical Imaging of Islet Transplantation
Richards, T. M., Sun, A., Hayat, H., Robertson, N., Zhang, Z., Fan, J., & Wang, P. (2020) · Life · doi:10.3390/life10090213 · Cited by 6
“This new imaging technology has already been utilized for stem cell tracking [48,49] and islet transplantation [50], and other indications.”
MethodIron oxide nanoparticles: current and future applications in nanomedicine
Ezealigo, B. N., Ezealigo, U. S., Ighodalo, K. I., & Ezema, F. I. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822819-7.00011-9 · Cited by 5
Soares, G. A., Pinto, L. A., Liebl, M., Biasotti, G. G. D. A., Prospero, A. G., Stoppa, E. G., Bakuzis, A. F., Baffa, O., Wiekhorst, F., & Miranda, J. R. D. A. (2022) · Journal of Biological Engineering · doi:10.1186/s13036-022-00305-9 · Cited by 5
Saline bolus for negative contrast perfusion imaging in magnetic particle imaging
Mohn, F., Exner, M., Szwargulski, P., Möddel, M., Knopp, T., & Graeser, M. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ace309 · Cited by 5
Advanced Nanotechnology Approaches as Emerging Tools in Cellular-Based Technologies
Soleymani-Goloujeh, M., Hosseini, S., & Eslaminejad, M. B. (2022) · Advances in experimental medicine and biology · doi:10.1007/5584_2022_725 · Cited by 5
Barrera, G., Allia, P., & Tiberto, P. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.034029 · Cited by 5
Evidence that SPIO Chain Formation is Essential for High-Resolution MPIPreprint
Colson, C., Fung, K. B., Bryan, J. T., Tay, Z. W., Fellows, B. D., Saayuja, C., Kuo, R., Chandrasekharan, P., & Conolly, S. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.11.27.518061 · Cited by 5
“The electronic magnetization of SPIOs is 22 million times greater than the nuclear magnetization of (1)H at 7T; so MPI scanners can measure even 5 nanograms of iron per voxel (roughly 200 cells) [2], [3].”
BackgroundMethodMiniaturization and low energy consumption approach to magnetic particle imaging
Fan, L., Wang, C., Tian, Y., Lou, D., Ma, Q., & Gu, N. (2025) · Nano Today · doi:10.1016/j.nantod.2025.102706 · Cited by 4
Chen, Z., Bian, Z., Ye, J., He, J., An, Y., & Tian, J. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae0861 · Cited by 4
“…(Haegele et al 2012, Salamon et al 2016, Ludewig et al 2022, Mason et al 2023), brain perfusion (Gräser et al 2019), tumor detection (Gräfe et al 2012, Yu et al 2017, Zhuo et al 2023), cell tracking (Them et al 2016, Zheng et al 2016), and targeted drug delivery (Hui et al 2023, Tong et al 2023).”
Saayujya, C., Fellows, B. D., Shi, Y., Sagar, R., Cary, B. G., Bryan, J. T., Yu, C., Kim, M., Hartley, A., Huynh, Q., et al. (2025) · Small · doi:10.1002/smll.202504794 · Cited by 4
Multi-Slice Knowledge-Driven System Matrix Calibration in Magnetic Particle Imaging
Guo, P., Wei, Z., Zeng, Y., Wang, B., Liao, Y., Hu, J., Hou, L., Liu, K., He, N., Wang, Q., et al. (2025) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2025.3636749 · Cited by 4
Elucidating Iron Metabolism through Molecular Imaging
Liao, F., Yang, W., Long, L., Yu, R., Qu, H., Peng, Y., Lu, J., Ren, C., Wang, Y., & Fu, C. (2024) · Current Issues in Molecular Biology · doi:10.3390/cimb46040175 · Cited by 4
Molecular Imaging in Medicine: Past, Present, and Future
Shu, K., Zurutuza, I. R., & Zaman, R. T. (2023) · JSM cardiothoracic surgery. · doi:10.47739/2573-1297.cardiothoracicsurgery.1019 · Cited by 4
Imaging technology in tracking the intravital fate of transplanted stem cells
Shen, L., Li, C., Li, Y., Guan, X., Zou, W., & Liu, J. (2025) · Pharmacological Research · doi:10.1016/j.phrs.2025.107752 · Cited by 4
Labeling T Cells to Track Immune Response to Immunotherapy in Glioblastoma
Rhee, J. Y., Ghannam, J. Y., Choi, B. D., & Gerstner, E. R. (2023) · Tomography · doi:10.3390/tomography9010022 · Cited by 4
One-pot synthesis of iron core—iron oxide shell nanoparticles with potential for magnetic imaging
Williams, A. G., Liu, L., Johnson, C. E., & Johnson, J. A. (2023) · Journal of Nanoparticle Research · doi:10.1007/s11051-023-05851-x · Cited by 4
“MPI offers increased depth penetration, no radiation, no background signal from tissues, and allows for real-time quantitative analysis of cells [14, 15].”
BackgroundShen, Y., Zhang, L., Hui, H., Guo, L., Wang, T., Yang, G., & Tian, J. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108250 · Cited by 4
Magnetic Particle Imaging and its Application
Ghorbani, F., Seyedi, S., & Montazerabadi, A. (2021) · Frontiers in biomedical technologies · doi:10.18502/fbt.v8i2.6518 · Cited by 4
Bai, Y., Tian, D., Ren, Z., Yue, D., Ren, Q., Li, P., & Pan, J. P. (2023) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37534 · Cited by 4
Song, C., Wang, Y., Lü, Y., & Wu, R. (2020) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2019-0900 · Cited by 4
Biomedical Applications of Nanoparticle Ferrites
Kalogirou, O. (2022) · Wiley eBooks · doi:10.1002/9781394156146.ch10 · Cited by 4
Precision nanoparticles for drug delivery, cell therapy tracking, and theranostics
Felder‐Flesch, D., Talamini, L., & Muller, S. (2024) · Comptes Rendus Chimie · doi:10.5802/crchim.348 · Cited by 3
Dadfar, S. M., Barmin, R. A., Li, Y., Schrank, F., Pantke, D., Roemhild, K., Dadfar, S. M. M., Rama, E., Möckel, D., Weiler, M., et al. (2026) · Nano Letters · doi:10.1021/acs.nanolett.5c04908 · Cited by 3
Shakeri‐Zadeh, A., Kuddannaya, S., Chu, C., Sood, K., Itoo, A. M., Zivko, C., Thomas, A. M., Mahairaki, V., Walczak, P., & Bulte, J. W. M. (2026) · Science Advances · doi:10.1126/sciadv.aec4482 · Cited by 3
“…diameter or 8,000 µm 3 for a spherical volume, which the cells have following trypsinization before injection) used before in pre-clinical MPI ( 8, 26 ) and clinical MRI ( 27 ) cell tracking studies, and human neural precursor cells (hNPCs), representing smaller cells (~10 µm in diameter or ~500…”
InfluentialA Simulation Study for Three Dimensional Tomographic Field Free Line Magnetic Particle Imaging
Soydan, D. A., Güngör, A., & Top, C. B. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9631111 · Cited by 3
“These particles are usually administered intravenously and used for various applications including vascular imaging, cell tracking and targeting, drug release, and hyperthermia [2]– [5].”
BackgroundNanoparticle-Based Treatment and Imaging of Brain Tumors Potentials and Limitations
Sina, E. M., Israel, L. L., Bong-Seop, L., Hanson, C. J., Amatya, R., Chung, E. H., Ghani, M. A., Yen, A., Black, K. L., Perez, J. M., et al. (2024) · Springer eBooks · doi:10.1007/978-3-030-80662-0_23 · Cited by 3
Knier, N. N., Dubois, V. P., Chen, Y., Ronald, J. A., & Foster, P. J. (2021) · Journal of Biological Methods · doi:10.14440/jbm.2021.356 · Cited by 3
Immune response treated with bone marrow mesenchymal stromal cells after stroke
Wang, Z., Wang, X., Liao, Y., Chen, G., & Xu, K. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.991379 · Cited by 3
“observed that intravenously delivered BMSCs are entrapped in lung microvasculature and are cleared to the liver in 1 day (14).”
BackgroundCorbin, B. A., Lutter, J. C., White, S. A., Al-Ani, E., Biros, E. S., Karns, J. P., & Allen, M. J. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823144-9.00157-6 · Cited by 3
Tang, Y., 陈, M. 鸣. C., Flesch, R. C. C., & 金, T. 涛. J. (2023) · Chinese Physics B · doi:10.1088/1674-1056/acde50 · Cited by 3
Magnetic nanoparticle-based hybrid materials in the biomedical field: fundamentals and applications
Baryeh, K., Attia, M., Ulloa, J. C., & Ye, J. Y. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823688-8.00005-3 · Cited by 3
A 4.8 T/m Magnetic Particle Imaging Scanner Design and Construction
Ütkür, M., Muslu, Y., & Sarıtaş, E. Ü. (2017) · National Biomedical Engineering Meeting · doi:10.1109/biyomut.2017.8479214 · Cited by 3
“MPG ile halihazırda anjiyografi [2, 3], kök hücre takibi [4, 5] ve kanser görüntüleme [6] gibi uygulama alanlarında ilerlemeler kaydedilmiştir.”
Regenerative Medicine Applied to the Treatment of Musculoskeletal Pathologies
González-González, A., García‐Sánchez, D., Alfonso-Fernández, A., Haider, K. H., Rodríguez-Rey, J. C., & Pérez-Campo, F. M. (2022) · Springer eBooks · doi:10.1007/978-981-19-2655-6_50 · Cited by 3
Mostufa, S., Azizi, E., Rezaei, B., Li, C., Gómez‐Pastora, J., He, R., & Wu, K. (2025) · AIP Advances · doi:10.1063/9.0000854 · Cited by 2
Enhanced performance of a single-sided MPI scanner with a hybrid surface-volume excitation coil
McDonough, C., Chrisekos, J., Hunt, C., & Tonyushkin, A. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae1f78 · Cited by 2
“…and safety, due to both the absence of ionizing radiation and the low toxicity of SPIO tracers, make it well-suited for clinical applications such as vascular imaging (Weizenecker et al 2009), cancer detection (Yu et al 2017), and cell tracking (Bulte et al 2015, Zheng et al 2015, 2016).”
Pawar, S., Lad, Y. S., Arepally, N., Carlton, H., Abu-Ayyad, M., Ivkov, R., & Attaluri, A. (2026) · International Journal of Hyperthermia · doi:10.1080/02656736.2026.2635293 · Cited by 2
Franke, J., & Chacon‐Caldera, J. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822532-5.00015-7 · Cited by 5
Rapid Analysis of Cell–Nanoparticle Interactions using Single‐Cell Raman Trapping Microscopy
Steinke, M. R., Zunhammer, F., Chatzopoulou, E. I., Teller, H., Schütze, K., Walles, H., Rädler, J. O., & Grüttner, C. (2018) · Angewandte Chemie · doi:10.1002/ange.201713151 · Cited by 2
Tracking of Stem Cells in Chronic Liver Diseases: Current Trends and Developments
He, J.-L., You, Y.-X., Xiong, P., Jiang, W., Zeng, Q., Chen, B., Wang, Y., Chen, E., Tang, H., Gao, X.-F., et al. (2023) · Stem Cell Reviews and Reports · doi:10.1007/s12015-023-10659-2 · Cited by 2
“Moreover, it has successfully addressed issues related to quantification of cells and eliminated the ambiguity associated with assigning contrast [17].”
Magnetic nanoparticles in magnetic particle imaging: principles and applications
Tay, Z. W., Saayujya, C., Huynh, Q., Bryan, J. T., Kuo, R., Yu, E. Y., Fellows, B. D., Chandrasekharan, P., & Conolly, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21668-8.00014-6 · Cited by 2
Wen, J., An, Y., Shao, L., Yin, L., Peng, Z., Liu, Y., Tian, J., & Du, Y. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108783 · Cited by 2
Wei, N., Chen, X., Liu, D., Bu, X., Wang, G., Sun, X., & Zhang, J. (2024) · Journal of Materials Chemistry B · doi:10.1039/d4tb00914b · Cited by 2
Dervis, M., Marey, A., Toumaj, S., Qafesha, R. M., Mashaly, D., Afify, A. Z., Langham, A., Jambawalikar, S., & Umair, M. (2025) · Bioengineering · doi:10.3390/bioengineering12111235 · Cited by 2
“…MRI detects signals from hydrogen protons and provides structural images, MPI detects iron oxide nanoparticles directly, offering superior sensitivity for tracer detection, and imaging of distribution over time, making it a modality of choice for biodistribution-based imaging, for example [47,48].”
Preparation and In Vitro Characterization of Magnetized miR-modified Endothelial Cells
Voronina, N., Lemcke, H., Wiekhorst, F., Kühn, J., Frank, M., Steinhoff, G., & David, R. (2017) · Journal of Visualized Experiments · doi:10.3791/55567 · Cited by 2
Nucleic Acid Amplification Strategies-Based Chemiluminescence Biosensors
Bi, S., & Yan, Y. (2019) · Springer eBooks · doi:10.1007/978-981-13-7044-1_3 · Cited by 2
Three-dimensional image reconstruction in projection-based magnetic particle imaging
Murase, K. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac15ad · Cited by 2
Hsu, F., Sun, R. Y., & Hsieh, C. (2019) · SPIN · doi:10.1142/s2010324719400071 · Cited by 2
Fink, C., Gevaert, J. J., Barrett, J. W., Dikeakos, J. D., Foster, P. J., & Dekaban, G. A. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.03.14.532667 · Cited by 2
Gevaert, J. J., Konkle, J., Goodwill, P. W., & Foster, P. J. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.22.545970 · Cited by 2
Evaluation of a Mouse-Sized Radial Gradiometer Receive Coil for Magnetic Particle Imaging
Schrank, F., Radermacher, H., Franke, J., Breham, S., Kiessling, F. M., & Schulz, V. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3568947 · Cited by 1
“MPI shows promising applications in fields such as vascular and perfusion imaging [2], [3], [4], [5], oncology imaging [6], [7], [8], and cell tracking [9], [10], [11], [12], [13].”
Cancer theranostics with magnetic particle imaging
Tay, Z. W., Yu, E. Y., Fung, K. B., Kuo, R., Fellows, B. D., Chandrasekharan, P., & Conolly, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-22253-5.00005-4 · Cited by 1
The application of magnetic therapy in stroke treatment: Traditional treatment and biomaterials
Fan, Y., Zhang, X., Zhang, L., Han, X., Zhao, H., Zhong, Y., Jiang, X., Wei, Y., Pi, Y., Wang, Y., et al. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.172060 · Cited by 1
Toumaj, S., Afifi, A., Dervis, M., Mashaly, D., AbuDraz, A., Hassan, A., Rustm, M., Jambawalikar, S., & Umair, M. (2026) · Bioengineering · doi:10.3390/bioengineering13060635 · Cited by 1
“This has prevented its translation into the clinic aside from vascular-based processes and diseases [5,34].”
Coded scenes for fast system calibration in magnetic particle imaging
İlbey, S., Top, C. B., Güngör, A., Sarıtaş, E. Ü., & Güven, E. (2018) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2018.8363582 · Cited by 1
Nanoengineering of stem cells for neural regenerative medicine
Altuntaş, E., Gözütok, K., & Özkan, B. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-820223-4.00006-1 · Cited by 1
Mesenchymal Stromal Cell Therapy for Thoracic Surgeons: An Update
Petrella, F., Cassina, E. M., Libretti, L., Pirondini, E., Raveglia, F., & Tuoro, A. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13121632 · Cited by 1
“Basal cells can operate as tissue-specific stem cells of the airway epithelium in the proximal airway, while in the distal airway, the bronchiolar epithelium is silent until damage happens when variant club cells—representing a group of secretory cells—disclose the ability to proliferate in response…”
BackgroundFunctionalized magnetic nanogels for diagnostic tools and devices
Dey, P., Ghosh, S., Chatterjee, A., Khanra, R., & Biswas, G. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-19012-4.00002-3 · Cited by 1
In Vivo Tracking of Amniotic Fluid Derived Stem Cells on Acellular Nerve Graft
Ma, X., Henry, K., Healy, K. M., Luo, T. D., Smith, T. L., & Li, Z. (2025) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2025.02.012 · Cited by 1
Fujii, Y., Furukawa, A., Iizuka, M., Seino, S., & Nakagawa, T. (2025) · Journal of the Magnetics Society of Japan · doi:10.3379/msjmag.2509r004 · Cited by 1
Molecular Imaging and Stem Cell Imaging
Shaikh, S. (2022) · Springer eBooks · doi:10.1007/978-981-16-9535-3_20 · Cited by 1
Recent Progress in Applications of Magnetic Nanoparticles in Medicine: A Review
-, R., Kaur, J., Singhal, S., & Kaushik, A. (2022) · Springer eBooks · doi:10.1007/978-981-16-9232-1_24 · Cited by 1
Magnetic Nanoparticles in Nanomedicine
STIUFIUC, G., Iacoviță, C., Toma, V., Stiufiuc, R. I., Tetean, R., & Lucaciu, C. M. (2021) · Wiley eBooks · doi:10.1002/9781119754725.ch2 · Cited by 1
Effects of scanning and reconstruction parameters on image quality in magnetic particle imaging
Bozkurt, E. (2018) · Bilkent University Institutional Repository (Bilkent University)
Variability of Excitation Coil Design and Performance in Magnetic Particle Imaging: A Review
Birahim, M. F. S., Othman, N. B., Sapuan, S. Z., Tomari, R., & Mohamad, E. J. (2019) · IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA) · doi:10.1109/icsima47653.2019.9057302
Yan, X., Hu, Y., Chen, W., Shi, X., Pan, Y., & Xu, Z. (2021) · Progress In Electromagnetics Research C · doi:10.2528/pierc21071201
Regenerative Medicine Applied to the Treatment of Musculoskeletal Pathologies
González-González, A., García‐Sánchez, D., Alfonso-Fernández, A., Haider, K. H., Rodríguez-Rey, J. C., & Pérez-Campo, F. M. (2022) · Springer eBooks · doi:10.1007/978-981-16-6016-0_50-1
Soares, G. A., Pinto, L. A., Liebl, M., Biasotti, G. G. D. A., Prospero, A. G., Stoppa, E. G., Bakuzis, A. F., Baffa, O., Wiekhorst, F., & Miranda, J. R. D. A. (2022) · Research Square · doi:10.21203/rs.3.rs-1616879/v1
A Review of Enabling Technologies for Magnetic Particle Imaging
Khandani, M. K., & Vosoughi, A. (2022) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas54063.2022.9859431
“Thus, these methods can be used for imaging cancerous tissue [17], imaging the brain [14], monitoring cardiovascular diseases [15], angiography [18], tracking stem cells [19] magnetic fluid hyperthermia [20], and investigating of the blood-brain barrier [21][22].”
Saline bolus for negative contrast perfusion imaging in magnetic particle imagingPreprint
Mohn, F., Exner, M., Szwargulski, P., Möddel, M., Knopp, T., & Graeser, M. (2023) · arXiv (Cornell University) · doi:10.15480/882.8557
An Improved Design of Detection Coil for Magnetic Particle Imaging
Zhang, R., Sun, S., Sun, S., Wei, J. H., Li, X., Zhong, J., & Xu, L. (2023) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc53148.2023.10175881
“The SPION magnetization is proportional to its concentration, in principle allowing quantitative imaging, which is of great significance for biomedical applications [4-8].”
BackgroundHuynh, Q., Doyle, O., Guo, K., Swamynathan, A., Huang, L., Garlepp, J., Dambal, N., Bryan, J. T., Ramdani, S., Saayujya, C., et al. (2023) · doi:10.36227/techrxiv.24309607.v1
Huynh, Q., Doyle, O., Guo, K., Swamynathan, A., Huang, L., Garlepp, J., Dambal, N., Bryan, J. T., Ramdani, S., Saayujya, C., et al. (2023) · doi:10.36227/techrxiv.24309607
Pant, A., Singh, G., Barnwal, R. P., Saini, S., Jain, A., & Singh, B. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13474-6.00010-x
Three-Dimensional Magnetic Particle Imaging Utilizing an Open-type System: A Feasibility Study
Nan, J., Nguyen, K. T., Park, J., Choi, E., & Kim, J. (2025) · Journal of Sensor Science and Technology · doi:10.46670/jsst.2025.34.1.1
Vašíček, J., Baláži, A., Tirpáková, M., Tomka, M., & Chrenek, P. (2025) · Journal of Developmental Biology · doi:10.3390/jdb13010006
“Moreover, several studies have been published studying the cellular uptake of different elements, such as ruthenium, platinum, gallium, silver, or iron, etc., by various cell lines [15–20] or cell efflux of, e.g., potassium during inflammasome activation [21].”
Metadata
- Authors
- Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Zheng, Bo
- ORCID
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2016
- Volume
- 6
- Issue
- 3
- Pages
- 291-301
- ISSN
- 1838-7640 (ISSN-L)
- PMC
- PMC4737718
- OpenAlex
- W2275153700
- Cited by
- 322
- References
- 53
- Citations by year
- 2026: 18 · 2025: 25 · 2024: 29 · 2023: 36 · 2022: 37 · 2021: 35 · 2020: 34 · 2019: 30 · 2018: 30 · 2017: 35 · 2016: 13
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Theranostics (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- tub.dok (Hamburg University of Technology) (submittedVersion, cc-by-nc)
- TUHH Open Research
- Funders
- W. M. Keck Foundation (009323)
- ACT Government
- Siebel Scholars Foundation
- National Institutes of Health (009323, NIH-R01)
- National Institute of Mental Health (R24MH106053)
- National Institute of Biomedical Imaging and Bioengineering (R01EB019458, R01EB013689)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Mesenchymal stem cell research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- magnetic particle imaging, mesenchymal stem cells, stem cell transplantation, cell biodistribution, cell clearance, stem cell therapy
- MeSH terms
- Animals, Diagnostic Imaging, Female, Ferric Compounds, Humans, Magnetics, Rats, Inbred F344, Staining and Labeling, Tissue Distribution, Mesenchymal Stem Cell Transplantation, Mice, Nanoparticles, Administration, Intravenous
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review