The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Quantitative Magnetic Particle Imaging Monitors the Transplantation, Biodistribution, and Clearance of Stem Cells In Vivo
Open accessAbstract
Stem cell therapies have enormous potential for treating many debilitating diseases, including heart failure, stroke and traumatic brain injury. For maximal efficacy, these therapies require targeted cell delivery to specific tissues followed by successful cell engraftment. However, targeted delivery remains an open challenge. As one example, it is common for intravenous deliveries of mesenchymal stem cells (MSCs) to become entrapped in lung microvasculature instead of the target tissue. Hence, a robust, quantitative imaging method would be essential for developing efficacious cell therapies. Here we show that Magnetic Particle Imaging (MPI), a novel technique that directly images iron-oxide nanoparticle-tagged cells, can longitudinally monitor and quantify MSC administration in vivo. MPI offers near-ideal image contrast, depth penetration, and robustness; these properties make MPI both ultra-sensitive and linearly quantitative. Here, we imaged, for the first time, the dynamic trafficking of intravenous MSC administrations using MPI. Our results indicate that labeled MSC injections are immediately entrapped in lung tissue and then clear to the liver within one day, whereas standard iron oxide particle (Resovist) injections are immediately taken up by liver and spleen. Longitudinal MPI-CT imaging also indicated a clearance half-life of MSC iron oxide labels in the liver at 4.6 days. Finally, our ex vivo MPI biodistribution measurements of iron in liver, spleen, heart, and lungs after injection showed excellent agreement (R(2) = 0.943) with measurements from induction coupled plasma spectrometry. These results demonstrate that MPI offers strong utility for noninvasively imaging and quantifying the systemic distribution of cell therapies and other therapeutic agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,163
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Mesenchymal Stem Cell Homing: The Devil Is in the Details
Karp, J. M., & Leng Teo, G. S. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.02.001 · Cited by 1,445
Fischer, U. M., Harting, M. T., Jimenez, F., Monzon-Posadas, W. O., Xue, H., Savitz, S. I., Laine, G. A., & Cox, C. S. (2009) · Stem Cells and Development · doi:10.1089/scd.2008.0253 · Cited by 1,292
The Dynamic in vivo Distribution of Bone Marrow-Derived Mesenchymal Stem Cells after Infusion
Gao, J., Dennis, J. E., Muzic, R. F., Lundberg, M., & Caplan, A. I. (2001) · Cells Tissues Organs · doi:10.1159/000047856 · Cited by 952
Gupta, N., Su, X., Popov, B. V., Lee, J. W., Serikov, V. B., & Matthay, M. A. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.179.3.1855 · Cited by 933
Bone Marrow–Derived Mesenchymal Stem Cells in Repair of the Injured Lung
Rojas, M., Xu, J., Woods, C. R., Mora, A. L., Spears, W., Roman, J., & Brigham, K. L. (2005) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2004-0330oc · Cited by 849
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Eggenhofer, E., Benseler, V., Kroemer, A., Popp, F. C., Geissler, E. K., Schlitt, H. J., Baan, C. C., Dahlke, M. H., & Hoogduijn, M. J. (2012) · Frontiers in Immunology · doi:10.3389/fimmu.2012.00297 · Cited by 804
Schlomka, J., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 803
Flagged first, then by citations
Cited by
Sorted by citations
Items 301–321 of 321
Ota, S., Yasuga, H., Akagawa, T., Kurashina, Y., Nakazawa, K., & Kikuchi, S. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70057
“In addition to individual cell manipulation, magnetic labeling of living cells creates opportunities for numerous biomedical applications, such as tracking by magnetic resonance imaging (Wilhelm and Gazeau 2008) and magnetic particle imaging (Zheng et al. 2016).”
Cao, T.-L., Tahir, M. U., Bùi, M. P., Ahmad, H. A., Gadelmowla, K. M., Oh, S., & Yoon, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3628415
“MPI has demonstrated potential for in vivo applications such as cell tracking [2], [3], vascular and perfusion imaging [4], targeted drug delivery [5], [6], and magnetic hyperthermia [7], [8].”
The Peculiar Effect of Scanning Trajectory Pattern Density on MPI-Reconstructed Image Quality
Duc, T., Kubasheva, A., Molnár, F., & Pham, T. T. (2025) · IEEE Access · doi:10.1109/access.2025.3638887
“Recent experimental MPI studies have demonstrated significant advances in biomedical applications, including vascular imaging [8], cell tracking [9], and interventional procedures [10], highlighting the growing clinical potential of this technique.”
The Synergy of Magnetic Particle Imaging and Magnetic Nanoparticle based Thermal Therapies
Tay, Z. W., Conolly, S., & Yoshinaka, K. (2025) · Thermal Medicine · doi:10.3191/thermalmed.41.25
Xu, Y., Liu, X., Li, Y., Dou, H., Liang, H., & Hou, Y. (2021) · Figshare · doi:10.6084/m9.figshare.16779451
Fink, C., Gevaert, J. J., Barrett, J. W., Dikeakos, J. D., Foster, P. J., & Dekaban, G. A. (2024) · Figshare · doi:10.6084/m9.figshare.26605774
Feinstein, J., Pujari, S., & Trubko, R. (2026) · Journal of Applied Physics · doi:10.1063/5.0299028
Iron Oxide Nanoparticles Enabled Ultrasound-Guided Theranostic Systems
Vicente, T. T., Periyathambi, P., Sanches, A. F., Nakakubo, M. Y. A., Zufelato, N., Salomão, K. B., Brassesco, M. S., Pavan, T. Z., Araki, K., & Carneiro, A. A. O. (2026) · Magnetochemistry · doi:10.3390/magnetochemistry12020021 · Cited by 1
“In addition, MPI has been widely investigated in various biomedical applications, including cardiovascular diagnosis [98–100], neuroimaging [101–103], and tumor detection [93], as well as cell tracking and monitoring [100,104–106].”
Gao, Y., Zhang, H., Zhao, J., Tong, R., Chen, J., Tian, J., & Zhang, H. (2026) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae5759
“…et al 2017, Yu et al 2017, Cooley et al 2018, Israel 2018), neuroimaging (Herb et al 2020, Shi et al 2023), cell tracking (Connell et al 2015, Zheng et al 2016, Lemaster et al 2018, Song et al 2018), and interventional surgical navigation (Vogel et al 2023, Wegner et al 2024, Guo et al 2025).”
Kampen, L., Kosch, O., Stach, A., Fiebig, N. D. C., Löwa, N., Wiekhorst, F., Ludwig, A., & Remmo, A. (2026) · Small Science · doi:10.1002/smsc.202500601
“In MPI, accurate read-outs rely on tracer retention and the physiological integrity of labeled cells [31 – 33].”
McDonough, C., Chrisekos, J., Jurj, M., Wiacek, A., & Tonyushkin, A. (2026) · Tomography · doi:10.3390/tomography12050060
“…MPI imaging was demonstrated in a range of preclinical applications, such as angiography [17,18], and perfusion [19]; cancer imaging [20], cell tracking [21,22], hyperthermia [23,24], and real-time tracking of interventional instruments: e.g., balloon catheters in cardiovascular procedures [25,26].”
Multifunctional Magnetic Resonance Imaging Probes
Komljenovic, D., Biegger, P., Abeln, H., & Ladd, M. E. (2026) · Recent results in cancer research/Recent Results in Cancer Research · doi:10.1007/978-3-032-15314-2_7
Semi-Wavelet Attention Transformer-Based MPI Reconstruction Algorithm
Cui, Y., Cai, Y., Zhang, J., Yin, L., Xiaowei, H. E., & Guo, H. (2026) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi61048.2026.11515796
“These include stem cell tracking, inflammatory imaging in traumatic brain injury, lung perfusion imaging, gastrointestinal bleeding detection, and tumor imaging [1].”
Ye, J., Chen, Z., Shi, G., Bian, Z., An, Y., & Tian, J. (2026) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi61048.2026.11515654
“Due to these features, MPI has been widely used in preclinical imaging, particularly in cancer detection[1], vascular imaging[2], and cellular tracking[3] studies, providing a novel approach for early disease diagnosis and functional imaging.”
Sun, Z., Guo, H., Su, L., Wen, J., He, K., Song, G., Niu, M., Tian, J., & Du, Y. (2026) · Small · doi:10.1002/smll.75514
A multi-angle Cartesian scanning strategy for large field-of-view Magnetic Particle Imaging
Huang, P., Zhou, G., Wang, C., Yang, J., Wang, R., An, Y., Tang, Z., & Tian, J. (2026) · Measurement · doi:10.1016/j.measurement.2026.123189
Magnetic nanoparticles in biomedicine
Bryan, J. T., Choi, C., & Wang, S. X. (2026) · Handbook of magnetic materials · doi:10.1016/bs.hmm.2026.08.001
A preclinical field-free line magnetic particle imaging system for molecular applications
Aderhold, E., Schumacher, J., Stagge, P., Knopp, T., Scheel, J., Volpert, T., Gräser, M., & Buzug, T. M. (2026) · Scientific Reports · doi:10.1038/s41598-026-74528-x
Size and Zinc Substitution Govern the MPI and MRI Performance of Ferrite Nanoparticle Tracers
Rezaei, B., Wang, H., Ponce, M. M., Shahriar, M. A., González, K. M. P., Tran, L. N. T., Chugh, V. K., Xu, C., Gómez-Pastora, J., He, R., et al. (2026) · ACS Materials Au · doi:10.1021/acsmaterialsau.6c00147
Metadata
- Authors
- Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Zheng, Bo
- ORCID
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2016
- Volume
- 6
- Issue
- 3
- Pages
- 291-301
- ISSN
- 1838-7640 (ISSN-L)
- PMC
- PMC4737718
- OpenAlex
- W2275153700
- Cited by
- 322
- References
- 53
- Citations by year
- 2026: 18 · 2025: 25 · 2024: 29 · 2023: 36 · 2022: 37 · 2021: 35 · 2020: 34 · 2019: 30 · 2018: 30 · 2017: 35 · 2016: 13
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Theranostics (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- tub.dok (Hamburg University of Technology) (submittedVersion, cc-by-nc)
- TUHH Open Research
- Funders
- W. M. Keck Foundation (009323)
- ACT Government
- Siebel Scholars Foundation
- National Institutes of Health (009323, NIH-R01)
- National Institute of Mental Health (R24MH106053)
- National Institute of Biomedical Imaging and Bioengineering (R01EB019458, R01EB013689)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Mesenchymal stem cell research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- magnetic particle imaging, mesenchymal stem cells, stem cell transplantation, cell biodistribution, cell clearance, stem cell therapy
- MeSH terms
- Animals, Diagnostic Imaging, Female, Ferric Compounds, Humans, Magnetics, Rats, Inbred F344, Staining and Labeling, Tissue Distribution, Mesenchymal Stem Cell Transplantation, Mice, Nanoparticles, Administration, Intravenous
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review