Utility of Nocturnal Home Oximetry for Case Finding in Patients with Suspected Sleep Apnea Hypopnea Syndrome
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate prospectively the validity of home oximetry for case finding in patients clinically suspected of having the sleep apnea hypopnea syndrome (SAHS). DESIGN: Blinded comparison of home oximetry and polysomnographic nocturnal recordings. SETTING: Sleep clinic of a tertiary referral center. PATIENTS: A total of 240 outpatients referred because of reported sleep disturbances or daytime hypersomnia compatible with the diagnosis of SAHS. MEASUREMENTS: All participants had nocturnal home oximetry followed by a conventional polysomnographic study. The two recordings were interpreted blindly. Home oximetry test results were classified as abnormal (suspicion of sleep-related breathing abnormalities) in the presence of repetitive, short-duration arterial oxyhemoglobin saturation. (SaO2) fluctuations without any absolute or relative decrease in the SaO2 threshold. The diagnosis of SAHS was confirmed when the apnea-plus-hypopnea index was greater than 10. RESULTS: Based on the results of the polysomnographic sleep study, 110 patients had SAHS (apnea-plus-hypopnea index, 38.1 +/- 2.5/h; mean +/- SE). Home oximetry test results were interpreted as abnormal in 176 patients (this included 108 patients with SAHS and 68 without SAHS) and were read as normal in 62 patients without SAHS and in 2 with SAHS. Home oximetry testing had a sensitivity of 108/110 or 98.2% (95% Cl, 93.6% to 99.8%); a specificity of 62/130 or 47.7% (Cl, 38.8% to 56.6%); a positive predictive value of 108/176 or 61.4%; and a negative predictive value of 62/64 or 96.9%. CONCLUSIONS: A negative home oximetry test result is helpful in ruling out the diagnosis of SAHS in patients clinically suspected of having this syndrome, because a negative test result reduced the probability from 54.1% to 3.1% in our patients. However, a positive oximetry test increased the probability from 46% to 61.4% in our group of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Nocturnal Pulse Oximetry as an Abbreviated Testing Modality for Pediatric Obstructive Sleep Apnea
Brouillette, R. T., Morielli, A., Leimanis, A., Waters, K. A., Luciano, R., & Ducharme, F. M. (2000) · Pediatrics · doi:10.1542/peds.105.2.405 · Cited by 576
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Pulmonary Complications of Obesity
Koenig, S. M. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200104000-00006 · Cited by 530
Portable Recording in the Assessment of Obstructive Sleep Apnea
Ferber, R., Millman, R., Coppola, M., Fleetham, J., Murray, C. F., Iber, C., McCall, W. V., Nino-Murcia, G., Pressman, M., Sanders, M., et al. (1994) · Sleep · doi:10.1093/sleep/17.4.378 · Cited by 433
Sleep-Disordered Breathing and Poor Functional Outcome After Stroke
Good, D. C., Henkle, J. Q., Gelber, D., Welsh, J., & Verhulst, S. (1996) · Stroke · doi:10.1161/01.str.27.2.252 · Cited by 417
The effect of obesity on chronic respiratory diseases: pathophysiology and therapeutic strategies
Poulain, M. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.051299 · Cited by 415
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
Flemons, W. W. (2002) · New England Journal of Medicine · doi:10.1056/nejmcp012849 · Cited by 362
The Indications for Polysomnography and Related Procedures
Chesson, A. L., Ferber, R. A., Fry, J. M., Grigg-Damberger, M., Hartse, K. M., Hurwitz, T. D., Johnson, S., Kader, G. A., Littner, M., Rosen, G., et al. (1997) · Sleep · doi:10.1093/sleep/20.6.423 · Cited by 362
Obesity and obstructive sleep apnea
Gami, A. S., Caples, S. M., & Somers, V. K. (2003) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(03)00069-0 · Cited by 338
Health-related quality of life in obstructive sleep apnoea
Lacasse, Y., Godbout, C., & Sériès, F. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00216902 · Cited by 320
Diagnosis of Obstructive Sleep Apnea in Adults
McNicholas, W. T. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-118mg · Cited by 285
HealthGear: A Real-time Wearable System for Monitoring and Analyzing Physiological Signals
Oliver, N., & Flores-Mangas, F. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06) · doi:10.1109/bsn.2006.27 · Cited by 255
Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
Vazquez, J.-C. (2000) · Thorax · doi:10.1136/thorax.55.4.302 · Cited by 254
King, A. C., Pruitt, L. A., Woo, S., Castro, C. M., Ahn, D. K., Vitiello, M. V., Woodward, S. H., & Bliwise, D. L. (2008) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/63.9.997 · Cited by 246
Association of Sleep-Disordered Breathing With Postoperative Complications
Hwang, D., Shakir, N., Limann, B., Sison, C., Kalra, S., Shulman, L., Souza, A. D. C., & Greenberg, H. (2008) · Chest · doi:10.1378/chest.07-1488 · Cited by 244
Chung, F., Liao, P., Elsaid, H., Islam, S., Shapiro, C. M., & Sun, Y. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318248f4f5 · Cited by 243
“Several studies used PSG on a different night to evaluate the predictive performance of the oximeter.(13,24,26) Because of the environmental difference between home and sleep laboratory, and night-to-night variability in the frequency of sleep apnea and hypopnea,(27,28) PSG not performed on the same night as oximetry…”
MethodRECOGNITION AND CONSEQUENCES OF OBSTRUCTIVE SLEEP APNEA HYPOPNEA SYNDROME
Redline, S., & Strohl, K. P. (1998) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(05)70428-7 · Cited by 191
Accuracy of Oximetry for Detection of Respiratory Disturbances in Sleep Apnea Syndrome
Lévy, P., Louis Pépin, J., Deschaux-Blanc, C., Paramelle, B., & Brambilla, C. (1996) · Chest · doi:10.1378/chest.109.2.395 · Cited by 188
Jafari, B., & Mohsenin, V. (2010) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2010.02.005 · Cited by 172
Nocturnal Hypoxemia Predicts Incident Cardiovascular Complications in Dialysis Patients
Zoccali, C., Mallamaci, F., & Tripepi, G. (2002) · Journal of the American Society of Nephrology · doi:10.1681/asn.v133729 · Cited by 163
The Value of Oxygen Desaturation Index for Diagnosing Obstructive Sleep Apnea: A Systematic Review
Rashid, N. H., Zaghi, S., Scapuccin, M., Camacho, M., Certal, V., & Capasso, R. (2021) · The Laryngoscope · doi:10.1002/lary.28663 · Cited by 115
Sériès, F., Kimoff, R. J., Morrison, D., Leblanc, M. H., Smilovitch, M., Howlett, J., Logan, A. G., Floras, J. S., & Bradley, T. D. (2005) · Chest · doi:10.1378/chest.127.5.1507 · Cited by 83
Self-citationDelta Sleep Response to Metyrapone in Post-Traumatic Stress Disorder
Neylan, T. C., Lenoci, M., Maglione, M. L., Rosenlicht, N. Z., Metzler, T. J., Otte, C., Schoenfeld, F. B., Yehuda, R., & Marmar, C. R. (2003) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300215 · Cited by 75
Upper Airway Resistance Syndrome: Effect of Nasal Dilation, Sleep Stage, and Sleep Position
(1999) · Sleep · doi:10.1093/sleep/22.5.592 · Cited by 60
BUMAN, M. P., HEKLER, E. B., BLIWISE, D. L., & KING, A. C. (2011) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2010.00866.x · Cited by 57
“…for oxygen saturation (<10% cumulative time at <90% SaO2) and desaturation index (>3% falls in SaO2 per sleep hour, <10 per hour; George et al., 1988; Series et al., 1993); and (e) mild to moderate sleep complaints (defined by scores ‡3 on at least two of three items: focused on getting to sleep;…”
BackgroundOxygen saturation regularity analysis in the diagnosis of obstructive sleep apnea
del Campo, F., Hornero, R., Zamarrón, C., Abasolo, D. E., & Álvarez, D. (2006) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2005.10.005 · Cited by 56
“found an OSA sensitivity of 98% for the visual inspection of the temporal oximetry recording, but specificity was only 48% [26].”
Gurubhagavatula, I., Nkwuo, J. E., Maislin, G., & Pack, A. I. (2008) · Accident Analysis & Prevention · doi:10.1016/j.aap.2007.04.011 · Cited by 51
Bureau, M. P. (2000) · Thorax · doi:10.1136/thorax.55.9.741 · Cited by 23
Yaddanapudi, S. S., Pineda, M. C., Boorman, D. W., Bryne, R. E., Hing, K. L., & Sharma, S. (2018) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2018.06.030 · Cited by 11
Metadata
- Authors
- Series, F., Marc, I., Cormier, Y., & La Forge, J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1993-09-15
- Volume
- 119
- Issue
- 6
- Pages
- 449-453
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2090009913
- Cited by
- 196
- References
- 0
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.