“Sensitivity” and “Specificity” Reconsidered: The Meaning of These Terms in Analytical and Diagnostic Settings
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Imprecise usage of the terms "sensitivity" and "specificity" produces confusion in the diagnostic use of sophisticated laboratory test results. "Analytical sensitivity" represents the smallest amount of substance in a sample that can accurately be measured by an assay. "Analytical specificity" refers to the ability of an assay to measure on particular organism or substance, rather than others, in a sample. An assay's analytical sensitivity and analytical specificity are distinct from that assay's clinical diagnostic sensitivity and diagnostic specificity. "Diagnostic sensitivity" is the percentage of persons who have a given disorder who are identified by the assay as positive for the disorder. High analytical sensitivity does not guarantee acceptable diagnostic sensitivity. "Diagnostic specificity" is the percentage of persons who do not have a given condition who are identified by the assay as negative for the condition. False-positive reactions occur because of sample contamination and diminish the diagnostic specificity of the assay. The terms "sensitivity" and "specificity" should be used with the requisite adjectives because the "diagnostic" and the "analytical" meanings of these terms are very different.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719 · cited 1×
“Since it was invented 11 years ago, PCR has gained wide applicability because the amplification process has been automated [12-14].”
BackgroundCao, Y., Qin, L., Zhang, L., Safrit, J., & Ho, D. D. (1995) · New England Journal of Medicine · doi:10.1056/nejm199501263320401 · Cited by 1,037
DNA Amplification for Direct Detection of HIV-1 in DNA of Peripheral Blood Mononuclear Cells
Ou, C.-Y., Kwok, S., Mitchell, S. W., Mack, D. H., Sninsky, J. J., Krebs, J. W., Feorino, P., Warfield, D., & Schochetman, G. (1988) · Science · doi:10.1126/science.3336784 · Cited by 972
Nocton, J. J., Dressler, F., Rutledge, B. J., Rys, P. N., Persing, D. H., & Steere, A. C. (1994) · New England Journal of Medicine · doi:10.1056/nejm199401273300401 · Cited by 591
Gordon, S. M., Eaton, M. E., George, R., Larsen, S., Lukehart, S. A., Kuypers, J., Marra, C. M., & Thompson, S. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312201 · Cited by 188
Rossi, A. D., Ades, A. E., Mammano, F., Mistro, A. D., Amadori, A., Giaquinto, C., & Chieco‐Bianchi, L. (1991) · AIDS · doi:10.1097/00002030-199101000-00002 · Cited by 121
Horowitz, H. W., Valsamis, M. P., Wicher, V., Abbruscato, F. C., Larsen, S. A., Wormser, G. P., & Wicher, K. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312204 · Cited by 74
Noordhoek, G. T., van Embden, J. D. A., & Kolk, A. H. J. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292713 · Cited by 44
Coutlée, F., Viscidi, R. P., Saint–Antoine, P., Kessous, A., & Yolken, R. H. (1991) · Molecular and Cellular Probes · doi:10.1016/0890-8508(91)90046-m · Cited by 40
Cited by
Diagnostic accuracy of serological tests for covid-19: systematic review and meta-analysis
Lisboa Bastos, M., Tavaziva, G., Abidi, S. K., Campbell, J. R., Haraoui, L.-P., Johnston, J. C., Lan, Z., Law, S., MacLean, E., Trajman, A., et al. (2020) · BMJ · doi:10.1136/bmj.m2516 · Cited by 832
Review: a comprehensive summary of a decade development of the recombinase polymerase amplification
Li, J., Macdonald, J., & von Stetten, F. (2019) · The Analyst · doi:10.1039/c8an01621f · Cited by 648
Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Burd, E. M. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00074-09 · Cited by 550
Statistical Evaluation of a Biomarker
Ray, P., Manach, Y. L., Riou, B., Houle, T. T., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181d47604 · Cited by 503
Molecular Biomarkers in Cancer
Sarhadi, V. K., & Armengol, G. (2022) · Biomolecules · doi:10.3390/biom12081021 · Cited by 467
Malaria rapid diagnostic tests: challenges and prospects
Mouatcho, J. C., & Goldring, J. P. D. (2013) · Journal of Medical Microbiology · doi:10.1099/jmm.0.052506-0 · Cited by 291
Cytokines as Biomarkers in Rheumatoid Arthritis
Burska, A., Boissinot, M., & Ponchel, F. (2014) · Mediators of Inflammation · doi:10.1155/2014/545493 · Cited by 222
Kristensen, L. S., & Hansen, L. L. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.121962 · Cited by 212
Reddy, M. M., Wilson, R., Wilson, J., Connell, S., Gocke, A., Hynan, L., German, D., & Kodadek, T. (2011) · Cell · doi:10.1016/j.cell.2010.11.054 · Cited by 203
“This preliminary study is promising in that it represents a high level of diagnostic sensitivity and specificity (Saah and Hoover, 1997), at least within the relatively limited range of samples analyzed.”
Review: Detection and quantification of proteins in human urine
Aitekenov, S., Gaipov, A., & Bukasov, R. (2021) · Talanta · doi:10.1016/j.talanta.2020.121718 · Cited by 181
Monitoring wastewater for assessing community health: Sewage Chemical-Information Mining (SCIM)
Daughton, C. G. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.11.102 · Cited by 178
The US Food and Drug Administration perspective on cancer biomarker development
Gutman, S., & Kessler, L. G. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1911 · Cited by 176
Guidelines on the laboratory aspects of assays used in haemostasis and thrombosis
Mackie, I., Cooper, P., Lawrie, A., Kitchen, S., Gray, E., Laffan, M., & British Committee for Standards in Haematology (2013) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12004 · Cited by 161
“It is important to know the lower limit of detection for most analytes [21].”
BackgroundEvaluation of Drugs With Specific Organ Toxicities in Organ-Specific Cell Lines
Lin, Z., & Will, Y. (2012) · Toxicological Sciences · doi:10.1093/toxsci/kfr339 · Cited by 158
“Next, for each IC50 value, the sensitivity (defined as the fraction of correctly predicted positives to all true positives in the clinic) and the specificity (defined as the fraction of correctly predicted negatives to all true negatives in the clinic) were calculated (Saah and Hoover, 1997).”
BackgroundChin, E. L., da Silva, C., & Hegde, M. (2013) · BMC Genetics · doi:10.1186/1471-2156-14-6 · Cited by 92
“The analytical specificity of an assay is its ability to identify only a specific substance [10].”
BackgroundMasny, A., Sałamatin, R., Rozej-Bielicka, W., & Golab, E. (2016) · Parasitology Research · doi:10.1007/s00436-015-4767-6 · Cited by 20
Metadata
- Authors
- Saah, A. J., & Hoover, D. R.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1997-01-01
- Volume
- 126
- Issue
- 1
- Pages
- 91-94
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2076873445
- Cited by
- 269
- References
- 9
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.