Location of Adenomas Missed by Optical Colonoscopy
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous estimates of the adenoma miss rate with optical colonoscopy (OC) are hindered by the use of OC as its own reference standard. OBJECTIVE: To evaluate the frequency and characteristics of colorectal neoplasms that are missed prospectively on OC by using virtual colonoscopy (VC) as a separate reference standard. DESIGN: Prospective, multicenter screening trial. SETTING: 3 medical centers. PARTICIPANTS: 1233 asymptomatic adults who underwent same-day VC and OC. MEASUREMENTS: Colorectal neoplasms (adenomatous polyps) missed at OC before VC results were unblinded. RESULTS: Fourteen (93.3%) of 15 nonrectal neoplasms were located on a fold; 10 (71.4%) of these were located on the backside of a fold. Five (83.3%) of 6 rectal lesions were located within 10 cm of the anal verge. LIMITATIONS: Estimation of the OC miss rate depended on polyp detection on both VC and second-look OC and therefore underestimates the true OC miss rate, particularly for smaller polyps. CONCLUSIONS: Most clinically significant adenomas missed prospectively on OC are located behind a fold or near the anal verge. The 12% OC miss rate for large adenomas (>or=10 mm) when state-of-the-art 3-dimensional VC is used as a separate reference standard is increased from the previous 0% to 6% estimates derived by using OC as its own reference standard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
Pickhardt, P. J., Choi, J. R., Hwang, I., Butler, J. A., Puckett, M. L., Hildebrandt, H. A., Wong, R. K., Nugent, P. A., Mysliwiec, P. A., & Schindler, W. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031618 · Cited by 1,972
Self-citationColonoscopic miss rates of adenomas determined by back-to-back colonoscopies
Rex, D., Cutler, C., Lemmel, G., Rahmani, E., Clark, D., Helper, D., Lehman, G., & Mark, D. (1997) · Gastroenterology · doi:10.1016/s0016-5085(97)70214-2 · Cited by 1,553
Cotton, P. B., Durkalski, V. L., Pineau, B. C., Palesch, Y. Y., Mauldin, P. D., Hoffman, B., Vining, D. J., Small, W. C., Affronti, J., Rex, D., et al. (2004) · JAMA · doi:10.1001/jama.291.14.1713 · Cited by 673
A Comparison of Colonoscopy and Double-Contrast Barium Enema for Surveillance after Polypectomy
Winawer, S. J., Stewart, E. T., Zauber, A. G., Bond, J. H., Ansel, H., Waye, J. D., Hall, D., Hamlin, J. A., Schapiro, M., O'Brien, M. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200006153422401 · Cited by 588
Prospective blinded trial of the colonoscopic miss-rate of large colorectal polyps
Hixson, L. J., Fennerty, M. B., Sampliner, R. E., & Garewal, H. S. (1991) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(91)70668-8 · Cited by 273
Pineau, B. C., Paskett, E. D., Chen, G. J., Espeland, M. A., Phillips, K., Han, J. P., Mikulaninec, C., & Vining, D. J. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00885-0 · Cited by 192
Surveillance Intervals after Colonoscopic Polypectomy
Waye, J. D., & Braunfeld, S. F. (1982) · Endoscopy · doi:10.1055/s-2007-1021585 · Cited by 137
Bond, J. (2001) · Endoscopy · doi:10.1055/s-2001-11185 · Cited by 98
Cited by
Levin, B., Lieberman, D. A., McFarland, B., Andrews, K. S., Brooks, D., Bond, J., Dash, C., Giardiello, F. M., Glick, S., Johnson, D., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.02.002 · Cited by 2,990
Self-citationAdenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Levin, B., Lieberman, D. A., McFarland, B., Smith, R. A., Brooks, D., Andrews, K. S., Dash, C., Giardiello, F. M., Glick, S., Levin, T. R., et al. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0018 · Cited by 1,801
Self-citationQuality indicators for colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, M. B., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.07.058 · Cited by 1,764
Quality Indicators for Colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, B. M., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.385 · Cited by 1,401
Colonoscopic Withdrawal Times and Adenoma Detection during Screening Colonoscopy
Barclay, R. L., Vicari, J. J., Doughty, A. S., Johanson, J. F., & Greenlaw, R. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa055498 · Cited by 1,313
Quality Indicators for Colonoscopy
Rex, D. K., Petrini, J. L., Baron, T. H., Chak, A., Cohen, J., Deal, S. E., Hoffman, B., Jacobson, B. C., Mergener, K., Petersen, B. T., et al. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00673.x · Cited by 845
Zhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660
Rockey, D., Paulson, E., Niedzwiecki, D., Davis, W., Bosworth, H., Sanders, L., Yee, J., Henderson, J., Hatten, P., Burdick, S., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17784-8 · Cited by 603
Hassan, C., Quintero, E., Dumonceau, J.-M., Regula, J., Brandão, C., Chaussade, S., Dekker, E., Dinis-Ribeiro, M., Ferlitsch, M., Gimeno-García, A., et al. (2013) · Endoscopy · doi:10.1055/s-0033-1344548 · Cited by 554
MORIKAWA, T., KATO, J., YAMAJI, Y., WADA, R., MITSUSHIMA, T., & SHIRATORI, Y. (2005) · Gastroenterology · doi:10.1016/j.gastro.2005.05.056 · Cited by 539
Quality indicators for colonoscopy
Rex, D. K., Petrini, J. L., Baron, T. H., Chak, A., Cohen, J., Deal, S. E., Hoffman, B., Jacobson, B. C., Mergener, K., Petersen, B. T., et al. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.02.021 · Cited by 493
Colorectal Cancer: CT Colonography and Colonoscopy for Detection—Systematic Review and Meta-Analysis
Pickhardt, P. J., Hassan, C., Halligan, S., & Marmo, R. (2011) · Radiology · doi:10.1148/radiol.11101887 · Cited by 467
Self-citationStandards of Practice Committee, Dominitz, J. A., Eisen, G. M., Baron, T. H., Goldstein, J. L., Hirota, W. K., Jacobson, B. C., Johanson, J. F., Leighton, J. A., Mallery, J. S., et al. (2003) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(03)80005-6 · Cited by 451
Singh, H., Turner, D., Xue, L., Targownik, L. E., & Bernstein, C. N. (2006) · JAMA · doi:10.1001/jama.295.20.2366 · Cited by 427
Five-Year Colon Surveillance After Screening Colonoscopy
Lieberman, D. A., Weiss, D. G., Harford, W. V., Ahnen, D. J., Provenzale, D., Sontag, S. J., Schnell, T. G., Chejfec, G., Campbell, D. R., Kidao, J., et al. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.07.006 · Cited by 406
Gong, D., Wu, L., Zhang, J., Mu, G., Shen, L., Liu, J., Wang, Z., Zhou, W., An, P., Huang, X., et al. (2020) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(19)30413-3 · Cited by 393
Graser, A., Stieber, P., Nagel, D., Schafer, C., Horst, D., Becker, C. R., Nikolaou, K., Lottes, A., Geisbusch, S., Kramer, H., et al. (2009) · Gut · doi:10.1136/gut.2008.156448 · Cited by 389
Rex, D. K., & Helbig, C. C. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.04.029 · Cited by 386
Allison, J. E., Sakoda, L. C., Levin, T. R., Tucker, J. P., Tekawa, I. S., Cuff, T., Pauly, M. P., Shlager, L., Palitz, A. M., Zhao, W. K., et al. (2007) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djm150 · Cited by 372
Stoop, E. M., de Haan, M. C., de Wijkerslooth, T. R., Bossuyt, P. M., van Ballegooijen, M., Nio, C. Y., van de Vijver, M. J., Biermann, K., Thomeer, M., van Leerdam, M. E., et al. (2012) · The Lancet Oncology · doi:10.1016/s1470-2045(11)70283-2 · Cited by 367
ASGE guideline: colorectal cancer screening and surveillance
Davila, R. E., Rajan, E., & Baron, T. H. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.02.002 · Cited by 339
Five-Year Colon Surveillance After Screening Colonoscopy
Barkin, J. S. (2008) · Yearbook of Medicine · doi:10.1016/s0084-3873(08)79033-3 · Cited by 335
Rembacken, B., Hassan, C., Riemann, J., Chilton, A., Rutter, M., Dumonceau, J.-M., Omar, M., & Ponchon, T. (2012) · Endoscopy · doi:10.1055/s-0032-1325686 · Cited by 333
A Quantitative Immunochemical Fecal Occult Blood Test for Colorectal Neoplasia
Levi, Z., Rozen, P., Hazazi, R., Vilkin, A., Waked, A., Maoz, E., Birkenfeld, S., Leshno, M., & Niv, Y. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-4-200702200-00003 · Cited by 326
Fisher, D. A., Maple, J. T., Ben-Menachem, T., Cash, B. D., Decker, G. A., Early, D. S., Evans, J. A., Fanelli, R. D., Fukami, N., Hwang, J. H., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.07.025 · Cited by 324
Park, D. I., Ryu, S., Kim, Y.-H., Lee, S.-H., Lee, C. K., Eun, C. S., & Han, D. S. (2010) · American Journal of Gastroenterology · doi:10.1038/ajg.2010.179 · Cited by 318
Colorectal Cancers Detected After Colonoscopy Frequently Result From Missed Lesions
Pohl, H., & Robertson, D. J. (2010) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2010.06.028 · Cited by 280
Computed Tomographic Virtual Colonoscopy Computer-Aided Polyp Detection in a Screening Population
Summers, R. M., Yao, J., Pickhardt, P. J., Franaszek, M., Bitter, I., Brickman, D., Krishna, V., & Choi, J. R. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.08.054 · Cited by 276
Self-citationBarclay, R. L., Vicari, J. J., & Greenlaw, R. L. (2008) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2008.04.018 · Cited by 271
Second-generation colon capsule endoscopy compared with colonoscopy
Spada, C., Hassan, C., Munoz-Navas, M., Neuhaus, H., Deviere, J., Fockens, P., Coron, E., Gay, G., Toth, E., Riccioni, M. E., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.03.1125 · Cited by 266
Maximizing Detection of Adenomas and Cancers During Colonoscopy
Rex, D. K. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00905.x · Cited by 264
Regge, D. (2009) · JAMA · doi:10.1001/jama.2009.832 · Cited by 241
“If a polyp measuring 6 mm or larger was detected at CT colonography but not at colonoscopy, the segment was reexamined to resolve the discrepancy.(20) The duration of colonoscopy and any adverse events were recorded.”
Gralnek, I. M., Siersema, P. D., Halpern, Z., Segol, O., Melhem, A., Suissa, A., Santo, E., Sloyer, A., Fenster, J., Moons, L. M. G., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70020-8 · Cited by 238
Butterly, L., Robinson, C. M., Anderson, J. C., Weiss, J. E., Goodrich, M., Onega, T. L., Amos, C. I., & Beach, M. L. (2014) · American Journal of Gastroenterology · doi:10.1038/ajg.2013.442 · Cited by 221
Collins, J. F., Lieberman, D. A., Durbin, T. E., Weiss, D. G., & and the Veterans Affairs Cooperative Study #380 Group* (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-2-200501180-00006 · Cited by 209
Leufkens, A. M., DeMarco, D. C., Rastogi, A., Akerman, P. A., Azzouzi, K., Rothstein, R. I., Vleggaar, F. P., Repici, A., Rando, G., Okolo, P. I., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2010.09.004 · Cited by 199
Kaminski, M., Bretthauer, M., Zauber, A., Kuipers, E., Adami, H.-O., van Ballegooijen, M., Regula, J., van Leerdam, M., Stefansson, T., Påhlman, L., et al. (2012) · Endoscopy · doi:10.1055/s-0032-1306895 · Cited by 173
Screening CT Colonography: How I Do It
Pickhardt, P. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2136 · Cited by 173
“For colonoscopic referral, we provide the gastroenterologist with digital images showing the polyp location on the 3D map, 3D endoluminal projections, and 2D multiplanar reconstructions (Fig. 6). Special note is made of polyps located on the backside of folds, which are more easily missed at colonoscopy [ 41 ].”
MethodSelf-citationHewett, D. G., & Rex, D. K. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.04.005 · Cited by 169
HASSAN, C., PICKHARDT, P. J., KIM, D. H., DI GIULIO, E., ZULLO, A., LAGHI, A., REPICI, A., IAFRATE, F., OSBORN, J., & ANNIBALE, B. (2010) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2009.04160.x · Cited by 163
Self-citationPickhardt, P. J., Taylor, A. J., Kim, D. H., Reichelderfer, M., Gopal, D. V., & Pfau, P. R. (2006) · Radiology · doi:10.1148/radiol.2412052007 · Cited by 161
Self-citationAniwan, S., Orkoonsawat, P., Viriyautsahakul, V., Angsuwatcharakon, P., Pittayanon, R., Wisedopas, N., Sumdin, S., Ponuthai, Y., Wiangngoen, S., Kullavanijaya, P., et al. (2016) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.440 · Cited by 87
Shah, S., Park, N., Chehade, N. E. H., Chahine, A., Monachese, M., Tiritilli, A., Moosvi, Z., Ortizo, R., & Samarasena, J. (2023) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.16059 · Cited by 52
Dachman, A. H., Kelly, K. B., Zintsmaster, M. P., Rana, R., Khankari, S., Novak, J. D., Ali, A. N., Qalbani, A., & Fletcher, J. G. (2008) · Radiology · doi:10.1148/radiol.2491080059 · Cited by 44
Microcomputed tomography colonography for polyp detection in an in vivo mouse tumor model
Pickhardt, P. J., Halberg, R. B., Taylor, A. J., Durkee, B. Y., Fine, J., Lee, F. T., & Weichert, J. P. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409915102 · Cited by 43
Self-citationLu, Z., Zhang, L., Yao, L., Gong, D., Wu, L., Xia, M., Zhang, J., Zhou, W., Huang, X., He, C., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.53840 · Cited by 16
Metadata
- Authors
- Pickhardt, P. J., Nugent, P. A., Mysliwiec, P. A., Choi, J. R., & Schindler, W. R.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2004-09-07
- Volume
- 141
- Issue
- 5
- Pages
- 352-359
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2050696607
- Cited by
- 446
- References
- 8
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.