QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 9,901–10,000 of 14,770
Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Berhane, S., Walsh, J., Reidy, P., Doherty, A., Hillier, B., Scandrett, K., Hettiarachchi, D., Islam, F., Mathangasinghe, Y., et al. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub4 · Cited by 14
Self-citationÇelik, A., Topaloğlu, E., & Yazıcı, M. M. (2025) · BMC Emergency Medicine · doi:10.1186/s12873-025-01431-5 · Cited by 4
Girardi, L., Zarka, F., Pradier, M., Visintini, S. M., Poletti, M., Gal, G. L., Wang, T., & Delluc, A. (2025) · Thrombosis Research · doi:10.1016/j.thromres.2025.109560 · Cited by 4
The Role of Intraoperative Flow Cytometry in Surgical Oncology: A Systematic Review
Romeo, E., Markopoulos, G. S., Vartholomatos, G., Voulgaris, S., & Alexiou, G. Α. (2025) · Cancers · doi:10.3390/cancers17243898 · Cited by 4
Gao, E. Y., Hao, Y., Tan, N. K. W., Ng, A. C. W., Leong, Z. H., Phua, C. Q., Ong, T. H., Leow, L. C., Huang, G.-B., Tan, B. K. J., et al. (2025) · Journal of Clinical Sleep Medicine · doi:10.1007/s44470-025-00013-3 · Cited by 4
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to evaluate the risk of bias and applicability of diagnostic accuracy studies [27].”
Exosomal microRNA biomarkers in ovarian cancer detection: systematic review and meta-analysis
Huang, Q., Chen, J., & Huang, J. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120771 · Cited by 5
Deragon, V., Baati, Y., Trudelle, L., Merabtine, A., Chapman, N., Picone, D. S., & Goupil, R. (2025) · Journal of the American Heart Association · doi:10.1161/jaha.125.042797 · Cited by 5
“The SPRINT trial 9 was highly influential and led to recommendation of a lower BP threshold in the 2017 US clinical practice guideline, 8 but the method of BP measurement used has come under close scrutiny.”
Zhang, X., Qi, Y., Wang, X., Chen, H., & Li, J. (2025) · Journal of Medical Internet Research · doi:10.2196/80981 · Cited by 4
“We evaluated the quality of the included studies using the Quality Assessment of Diagnostic Performance Studies (QUADAS-2) tool [18], replacing some of the unrelated criteria with more relevant standards from another applicable tool (the Prediction Model Risk of Bias Assessment Tool) [19].”
Geysels, A., Garofalo, G., Timmerman, S., Ceusters, J., Buonomo, F., Fischerová, D., Testa, A. C., Moro, F., Sladkevicius, P., Jokubkiene, L., et al. (2025) · npj Precision Oncology · doi:10.1038/s41698-025-01215-x · Cited by 7
Díaz, G., Prado, C. M. M., González, M. C., & Rugeles, M.-P. (2025) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2025.106121 · Cited by 5
Alsabri, M., Abouelmagd, K., Elsnhory, A. B., Hasan, M. T., Rath, S., Elnady, M. I., Cheng, Y., Abady, E. M. A., Tawfik, A. M., Elshabrawi, M. N., et al. (2025) · BMC Emergency Medicine · doi:10.1186/s12873-025-01455-x · Cited by 7
“This tool assesses the risk of bias in four domains: patient selection, index test, reference standard, and flow and timing, as well as the applicability concerns of these domains to the review question [15].”
Corso, M., Martin, K., Salmi, L., Wright, D. S., Quon, J., Cancelliere, C., Mior, S. A., Murnaghan, K., & Côté, P. (2025) · BMC Family Practice · doi:10.1186/s12875-025-03132-1 · Cited by 4
“We used Risk-of-Bias 2 (ROB 2) tool for RCTs, [20] Quality Appraisal of Diagnostic Reliability Checklist (QAREL) for reliability studies, [21] and Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) for diagnostic accuracy studies [22].”
Wang, H., Wang, J., & Li, G. (2025) · Journal of Cancer Research and Therapeutics · doi:10.4103/jcrt.jcrt_1144_25 · Cited by 4
Salih, E. L. M., Farah, A., Mohammed, H., Adam, H. S. B., & Abdullah, R. B. A. (2026) · Cureus · doi:10.7759/cureus.100734 · Cited by 4
“The quality of included studies and risk of bias were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [11], which evaluates patient selection, index test, reference standard, and flow and timing.”
Saliva and blood miRNAs as complementary biomarkers for esophageal cancer detection
Maxwell, M. K., & NONAKA, T. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2025.1642705 · Cited by 5
“To ensure methodological robustness, study quality was assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool (35).”
Elhaie, M., Koozari, A., & Abedi, I. (2026) · Egyptian Liver Journal · doi:10.1186/s43066-025-00479-z · Cited by 4
“The methodological quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [14].”
Cara, M. D., Domenico, C. D., Piccolo, A., Alito, A., Costa, L., Quartarone, A., & Cucinotta, F. (2026) · Medical Sciences · doi:10.3390/medsci14010028 · Cited by 4
Zhao, C., Li, M., Chen, R., Zhao, Y., Li, J., Zhao, W., Li, X., Zhang, J. J., Yu, S., & Wei, L. (2026) · Systematic Reviews · doi:10.1186/s13643-025-02947-4 · Cited by 4
“The QUADAS-2 scale was used to assess the design and reporting quality of cross-sectional studies [20].”
Scobie, C., Dean, R. S., Stavisky, J., & Plüddemann, A. (2026) · Veterinary Record · doi:10.1002/vetr.70216 · Cited by 4
Sadabad, F. E., Honhar, P., Houshi, S., Nejati, S. F., Bagherieh, S., Brackett, A. L., Yazdanpanah, F., Çayır, S., Hosseini, M., Tagare, H. D., et al. (2026) · Neurological Sciences · doi:10.1007/s10072-025-08768-6 · Cited by 5
“Quality assessment of included studies was performed using eight domains adapted from the PRISMA 2020 guidelines and the QUADAS-2 framework for diagnostic accuracy studies [20].”
Zhao, R., Yang, H., Li, Y., Li, X., Yang, Z., Lin, Y., Huang, J., Wan, L., & Huang, H. (2026) · Journal of Medical Internet Research · doi:10.2196/75965 · Cited by 4
“The bias of risk in the eligible studies was assessed via Quality Assessment of Diagnostic Accuracy Studies-2, a tool for evaluating the collation risk of bias and clinical applicability of original diagnostic studies [13].”
Harrison, H. S. G., Peters, E. J. G., Maas, M. M., Lavery, L. A., & Beekman, K. M. (2026) · Wound Repair and Regeneration · doi:10.1111/wrr.70128 · Cited by 4
Medication adherence tools and measures in chronic kidney disease: a systematic review
Roohi, E., Rahmatian, D., Borkum, M. S., Bredenkamp, N., Ho, C., Wu, H., Haubrich, K., Pietrobon, A., Gregson, S., Atiquzzaman, M., et al. (2026) · BMC Nephrology · doi:10.1186/s12882-025-04734-8 · Cited by 4
Sadeghpour, S., Aghaee, A., Sadeghpour, S., Rizzo, A., Pizzuto, D. A., Annunziata, S., Treglia, G., & Sadeghi, R. (2026) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-025-07735-9 · Cited by 4
Wu, X., & Yao, W. (2026) · Journal of Surgical Oncology · doi:10.1002/jso.70167 · Cited by 5
Treglia, G., Albano, D., Wittebole, X., Glaudemans, A. W. J. M., Pillay, J., & Gheysens, O. S. (2026) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-025-07759-1 · Cited by 5
Liu, J., Li, D., Zhuo, Y., & Zhang, S. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2026.1734591 · Cited by 4
Deep Learning for Brain Tumor Analysis: A Systematic Review of the BraTS Dataset
Shirehjini, O. F., & Mofrad, F. B. (2026) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-026-10493-y · Cited by 6
You, H., He, J., & Tian, T. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1735752 · Cited by 4
Fujimoto, Y., Yamada, K., & Yoshida, T. (2026) · Critical Care · doi:10.1186/s13054-026-05849-6 · Cited by 4
Becerra, C. A. G., Gallardo, M. I. A., Garcia, J. E. J., Soltero-Molinar, V., Rassi, A. J. E., Rivera-Rocha, M. I., Parra-Camaño, L. F., Ruiz, M., Garcia-Becerra, N., Cordeiro, M., et al. (2026) · Prostate Cancer and Prostatic Diseases · doi:10.1038/s41391-026-01079-7 · Cited by 4
“…was independently assessed by two reviewers (C.A.G.B. and L.F.P.C.) using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, [17] the revised Cochrane Risk of Bias tool for randomized trials (RoB-2), [18] and the Risk of Bias in Non-randomized Studies of Interventions…”
Khavandegar, A., Ramezani, Z., Khodadoust, E., Tabatabaei, M. S. H. Z., Maleki, T., Dehnavi, N. S., Ganau, M., Prisco, L., Kheiri, G., Ramzi, N., et al. (2026) · Neurosurgical Review · doi:10.1007/s10143-025-04091-y · Cited by 4
“Disagreements were resolved through discussion, and when consensus could not be reached, a third reviewer was consulted [15].”
Alsabri, M., Rath, S., Elkarargy, M. A., Aboali, A. A., Abouelmagd, K., Ramadan, A. A. A., Gamboa, L. L., Yoo, P., & Cheng, Y. (2026) · International Journal of Emergency Medicine · doi:10.1186/s12245-026-01134-z · Cited by 4
“Methodological quality and risk of bias were assessed independently by two reviewers using the QUADAS-2 tool [17], with any disagreements resolved through discussion or adjudication by a third reviewer.”
Chen, H., Fan, B., Yuan, M., Wang, D., Qiao, C., Qiu, N., Quan, X., & Hou, W. (2026) · Frontiers in Immunology · doi:10.3389/fimmu.2026.1753166 · Cited by 5
“The Radiomics Quality Score version 2.0 (RQS) checklist and the QUADAS-2 tool were employed to evaluate the included studies (21, 22).”
Influentialde Oliveira, D. S., Costa, G. J., Lévy, S., & Delgado, A. (2026) · Pediatric Pulmonology · doi:10.1002/ppul.71537 · Cited by 4
Prabhakaran, S., Bell, S. W., Lee, J. C., & Kong, J. C. H. (2026) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2026.111741 · Cited by 5
Carbone, F., Ciardiello, D., Granieri, S., Fazio, N., Avallone, A., & Delrio, P. (2026) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2026.105289 · Cited by 4
Multimodal biomarker AI techniques for early neurocognitive disorder diagnosis: A systematic review
Catino, F., Castellana, F., Zupo, R., Giannoccaro, V., Lampignano, L., Petrosillo, A. M., Addabbo, F., Sborgia, G., Colacicco, G., Santoro, C., et al. (2026) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2026.103389 · Cited by 5
Tariq, U., Ahmed, I., Shaukat, K., & Ihsan, M. (2026) · International Journal of Computational Intelligence Systems · doi:10.1007/s44196-026-01283-2 · Cited by 4
The Crossroads of Neuroinflammation and Biomarkers in Multiple Sclerosis: A Systematic Review
Gavrilă, M.-G., Albu, C. V., Albu, B. C., Burada, E., Sandu, R. E., & Surugiu, R. (2026) · Cells · doi:10.3390/cells15070610 · Cited by 5
Ardila, C. M., Pineda‐Vélez, E., Vivares‐Builes, A. M., & Díaz-Laclaustra, A. I. (2026) · Medical Sciences · doi:10.3390/medsci14020183 · Cited by 5
Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review
Chen, X., Yang, Y., Fischer, N., Robertshaw, H. H., Jackson, B., Shikh‐Bahaei, M., Bergeles, C., & Booth, T. C. (2026) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2026.3681030 · Cited by 4
“To evaluate methodological rigor and potential biases in the included studies, this systematic review employed two established tools: the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) [44] and the Risk Of Bias In Non-randomized Studies of Interventions (ROBINS-I) [45].”
Does This Child Have a Concussion? The Rational Clinical Examination Systematic Review
Shah, S. N., Chizuk, H. M., Fong, H., Hannon, M., & Mannix, R. (2026) · JAMA · doi:10.1001/jama.2026.1233 · Cited by 5
Suganya, P., Duppada, P., Sruthi, K. G., Panda, P., & Mohanty, J. R. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106433 · Cited by 6
AI in Oral Health Surveillance: Critical Review
Chen, Z., Liu, P., Han, K., Liao, P., Yang, Y., Wong, M., Yiu, C. K. Y., & Lo, E. C. M. (2026) · Journal of Dental Research · doi:10.1177/00220345261434568 · Cited by 5
“Given that conventional tools like QUADAS-2 (Whiting et al 2011) are insufficient for evaluating AI-specific risks of bias, such as annotation ambiguity, algorithmic bias, and model generalizability, we developed a specialized quality assessment checklist (Appendix Tables 3 and 4).”
Zhou, H., Dai, Y., Zhang, H., Yang, Y., Pi, R., Zhu, L., & Chen, W. (2026) · Journal of Gynecologic Oncology · doi:10.3802/jgo.2026.37.e68 · Cited by 4
Susanti, L., Cuandra, K. N., Tristan, C. D., Fatahillah, M. Z., Shofiy, A. R., Sihombing, N. M. I., Siahaan, S. R. U., Onggowasito, L. A., Widnyana, I. K. T. Y., Rahmah, S. A. Z., et al. (2026) · Neurology Research International · doi:10.1155/nri/5709868 · Cited by 4
AI‐Enabled Imaging for Pathogen Detection Under Stress Conditions: A Systematic Review
Papa, M., Kuehnle, G., Oh, Y. J., & Yi, J. (2026) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.70468 · Cited by 4
Boostani, M., Siegel, A. P., Eathara, A., Kiss, N., Paragh, G., Tsoukas, M. M., & Avanaki, K. (2026) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2026.02.021 · Cited by 5
MRI Diagnosis of Meniscus Tears in the Knee: An Updated Systematic Review and Meta-analysis
Nguyen, J. C., Yaya-Quezada, C., Lerebo, W. T., Patel, V. S., Chalian, M., Flores, D. V., Gorbachova, T., Kani, K. K., Mills, M. K., Stevens, K. J., et al. (2026) · Radiology · doi:10.1148/radiol.252288 · Cited by 7
Guimarães, H. H. D. S. D., & Matos, K. (2026) · Journal of Dentistry · doi:10.1016/j.jdent.2026.106736 · Cited by 5
The potential of clustering methods for pre-test triage in sleep medicine: A systematic review
Almeida, F., Martín‐Montero, A., Gutiérrez‐Tobal, G. C., Gómez‐Pilar, J., Hornero, R., Rodrigues, P. P., Amorim, P., Monteiro‐Soares, M., & Ferreira-Santos, D. (2026) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2026.102308 · Cited by 4
Rouhi, A. D., Menon, S. V., Ghanem, Y. K., & Han, J. J. (2026) · Cardiology and Therapy · doi:10.1007/s40119-026-00453-9 · Cited by 4
Klompmaker, P., Opschoor, K., ten Dalen, J., de Vries, M. R., Balan, C. I., Veelo, D. P., Vlaar, A. P. J., & Tuinman, P. R. (2026) · Critical Care Medicine · doi:10.1097/ccm.0000000000007219 · Cited by 4
Holiel, A. A., Nakouzi, M. M. A., Cuevas‐Suárez, C. E., Flores‐Ledesma, A., Drouri, S., & Bourgi, R. (2026) · Biomedical Engineering and Computational Biology · doi:10.1177/11795972261463709 · Cited by 4
Miguel, L. S., Jespers, V., & Roberfroid, D. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15134858 · Cited by 4
Lotsu, J. S., Frimpong, S., & Raza, M. A. (2026) · Mining · doi:10.3390/mining6030045 · Cited by 4
Tyldesley‐Marshall, N., Chen, Y., Buendía, J. A., Brown, A., Matthews, T., Parr, J., Chockalingam, S., Elfeky, A., Grove, A., Andronis, L., et al. (2026) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.70637 · Cited by 4
Gee, M. F. W., Chalfin, D. B., Devol, E. B., Levy, H. R., Boltyenkov, A., Casale, M. G., & Sanyal, A. J. (2026) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.70846 · Cited by 5
Gardner, I. A., Burnley, T., & Caraguel, C. (2014) · Journal of Aquatic Animal Health · doi:10.1080/08997659.2014.938867 · Cited by 4
Elias-Sonnenschein, L. S., Viechtbauer, W., Ramakers, I. H. G. B., Ukoumunne, O. C., Verhey, F. R. J., & Visser, P. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010948 · Cited by 4
RetractedKim, J. F., Nwaru, B. I., McCleary, N., Stoddart, A., & Sheikh, A. (2017) · npj Primary Care Respiratory Medicine · doi:10.1038/s41533-017-0015-0 · Cited by 5
Tang, A., McInnes, M. D. F., Hope, T. A., Vu, K., Amre, D. K., Wolfson, T. J., Roy, C., Mâsse, B. R., & Sirlin, C. B. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012766 · Cited by 4
RetractedBarčot, O., Borić, M., Ćavar, M., Poropat, G., & Puljak, L. (2020) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2020.12.005 · Cited by 5
Sacerdoțianu, V. M., Ungureanu, B. S., Iordache, S., Turcu-Ştiolică, A., Facciorusso, A., Crinò, S. F., & Săftoiu, A. (2022) · Diagnostics · doi:10.3390/diagnostics12010100 · Cited by 4
Kazi, S., Frank, R. A., Salameh, J., Fabiano, N., Absi, M., Pozdnyakov, A., Islam, N., Korevaar, D. A., Cohen, J. F., Bossuyt, P. M., et al. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28116 · Cited by 5
Self-citationElias-Sonnenschein, L. S., Viechtbauer, W., Ramakers, I. H. G. B., Ukoumunne, O. C., Verhey, F. R. J., & Visser, P. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010949 · Cited by 4
RetractedElias-Sonnenschein, L. S., Viechtbauer, W., Ramakers, I. H. G. B., Ukoumunne, O. C., Verhey, F. R. J., & Visser, P. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010950 · Cited by 4
RetractedKim, D. H., Kim, S. W., Basurrah, M. A., & Hwang, S. H. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11206069 · Cited by 4
Cardozo, L. C. M., Lemos, G. S. D., & Besen, B. A. M. P. (2022) · Medicina Intensiva (English Edition) · doi:10.1016/j.medine.2021.12.018 · Cited by 4
Wang, Y., Jin, Y., Li, M., Zhang, J., Wang, S., Zhang, H., & Song, B. (2022) · Medicine · doi:10.1097/md.0000000000031574 · Cited by 4
Oh, J. S., Jayasimhan, D., & Sithamparanathan, S. (2023) · Internal Medicine Journal · doi:10.1111/imj.16021 · Cited by 5
Kim, D. H., Kim, S. W., Han, J. S., Kim, G., Basurrah, M. A., & Hwang, S. H. (2023) · Medicina · doi:10.3390/medicina59030540 · Cited by 4
Zhu, M., Lü, Z., Guo, H., Gu, X., Wei, D., & Zhang, Z. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1136049 · Cited by 4
Procalcitonin for the diagnosis of sepsis in neonates: a diagnostic test accuracy review
Srinivasan, L., Balasubramanian, H., Stewart, M. T., Weiss, E. M., Kirpalani, H. M., Cooper, C., & Gautham, K. S. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014196 · Cited by 10
Jannatdoust, P., Valizadeh, P., Razaghi, M., Rouzbahani, M., Abbasi, A., & Arian, A. (2023) · Research in Diagnostic and Interventional Imaging · doi:10.1016/j.redii.2023.100030 · Cited by 4
Kondo, Y., Mihara, T., Nakamura, E., Noma, H., Shimizu, S., & Goto, T. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-069309 · Cited by 4
Sabrie, N., Khan, R., Jogendran, R., Scaffidi, M., Bansal, R., Gimpaya, N., Youssef, M., Forbes, N., Mosko, J. D., Berzin, T. M., et al. (2023) · iGIE · doi:10.1016/j.igie.2023.07.012 · Cited by 5
“14”
FDG–PET in patients with autoimmune encephalitis: a review of findings and new perspectives
Baldissin, M. M., de Souza, E. M., Watanabe, N., Etchebehere, E., Cendes, F., & Amorim, B. J. (2023) · Clinical and Translational Imaging · doi:10.1007/s40336-023-00581-5 · Cited by 4
“The quality of the methodological approaches of the articles was assessed based on the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) [41].”
Pierce, Z. P., & Black, J. M. (2023) · Journal of Affective Disorders Reports · doi:10.1016/j.jadr.2023.100674 · Cited by 4
RetractedKobeissy, A. A., Merza, N., Nawras, Y., Bahbah, E. I., Al‐Hillan, A., Ahmed, Z., Hassan, M. M., & Alastal, Y. (2023) · International Journal of Colorectal Disease · doi:10.1007/s00384-023-04544-0 · Cited by 4
Ko, W. S., & Kim, S.-J. (2023) · Clinical Radiology · doi:10.1016/j.crad.2023.10.021 · Cited by 4
Tang, L., Pan, M., & Wu, F. (2024) · Pediatric Neurology · doi:10.1016/j.pediatrneurol.2024.01.010 · Cited by 7
Ashiq, N., Khan, S., & Yousaf, A. (2024) · Indian journal of radiology and imaging - new series/Indian journal of radiology and imaging/Indian Journal of Radiology & Imaging · doi:10.1055/s-0044-1778726 · Cited by 4
MacNevin, W., Chua, M. E., Kraus, M. S., & Keefe, D. T. (2024) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2024.03.007 · Cited by 4
Liu, Q., Liu, T., Liu, X., Zhang, F., Yang, J., Cheng, Y., & Yang, Q. (2024) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-23-1184 · Cited by 4
Sesgundo, J. A., Maeng, D. C., Tukay, J. A., Ascano, M. P., Suba-Cohen, J., & Sampang, V. (2024) · JMIR Research Protocols · doi:10.2196/57292 · Cited by 4
miRNA-143 as a potential biomarker in the detection of bladder cancer: a meta-analysis
Li, J., Li, H., Yang, Y., Sen, Y., & Ye, J. (2024) · Future Oncology · doi:10.2217/fon-2023-0922 · Cited by 4
Gebregergs, G. B., Berhe, G., Gebrehiwot, K. G., & Mulugeta, A. (2024) · SAGE Open Medicine · doi:10.1177/20503121241243238 · Cited by 4
Zhang, A., Zhang, J., Liu, Y., Wang, S., Bai, J., Sun, L., & Li, T. (2024) · Journal of Oral Pathology and Medicine · doi:10.1111/jop.13542 · Cited by 5
Aditya, A., Kore, A., Patil, S., Vinay, V., & Happy, D. (2023) · Journal of Indian Academy of Oral Medicine and Radiology · doi:10.4103/jiaomr.jiaomr_319_23 · Cited by 5
Kientzy, M., Bursztejn, A. ‐., Allaudeen, A. P., Chenuel, B. J., Hamroun, A., & Allado, E. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-085969 · Cited by 4
Ssedyabane, F., Obuku, E. A., Namisango, E., Ngonzi, J. N. J., Castro, C. M., Lee, H., Randall, T. C., Ocan, M., Apunyo, R., Kinengyere, A. A., et al. (2024) · Gynecologic Oncology Reports · doi:10.1016/j.gore.2024.101424 · Cited by 6
Dizaji, S. R., Ahmadzadeh, K., Zarei, H., Miri, R., & Yousefifard, M. (2024) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000001147 · Cited by 5
“The risk of bias in included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) tool [16].”
Mishra, A., Jena, P. K., & Panda, S. K. (2024) · Pediatrics & Neonatology · doi:10.1016/j.pedneo.2024.03.007 · Cited by 4
Hearing Screening for Older Adults With Cognitive Impairment: A Systematic Review
Limkitisupasin, P., Jongpradubgiat, P., & Utoomprurkporn, N. (2024) · Journal of Audiology & Otology · doi:10.7874/jao.2023.00507 · Cited by 4
“We used Quality Assessment of Diagnostic Accuracy-2 (QUADAS-2) [17] to assess the methodological quality of studies included in the review.”
Li, X., Liang, Y., & Lin, X. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1389813 · Cited by 6
Iqhrammullah, M., Yusnaini, R., Amirah, S., Mulya, I. C., Tsurayya, G., Naufal, M. A., Santosa, S. F., Harapan, H., & Zulkifli, B. (2024) · Microbes and Infection · doi:10.1016/j.micinf.2024.105396 · Cited by 4
Shafiq, Y., Fung, A., Driker, S., Rees, C. A., Mediratta, R. P., Rosenberg, R. E., Hussaini, A. S., Adnan, J., Wade, C. G., Chou, R., et al. (2024) · PEDIATRICS · doi:10.1542/peds.2024-066588e · Cited by 5
Schipaanboord, D. J. M., Woudstra, J., Appelman, Y., Rittersma, S. Z. H., van de Hoef, T. P., van Es, R., Coronel, R., Damman, P., van der Harst, P., Onland‐Moret, N. C., et al. (2024) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.70003 · Cited by 4
“DS and JW independently performed the methodological quality assessment using the QUADAS-2 tool (Whiting et al. 2011).”
Method
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.