QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 10,001–10,100 of 14,770
Mortaki, A., Douligeris, A., Panagiotopoulos, M. G., Daskalaki, M.-A., Vasilios, P., Panagiotis, A., George, D., & Marianna, T. (2024) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2024.102663 · Cited by 4
Diagnostic Value of Contrast‐Enhanced Ultrasound in Benign and Malignant Adnexal Masses
Zhang, B., & Han, X. (2024) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16580 · Cited by 4
Scaglione, G., Travaglino, A., Raffone, A., Santoro, A., Arciuolo, D., Fulgione, C., D’Alessandris, N., Pannone, G., Urtueta, B. P., Narducci, N., et al. (2024) · Pathology - Research and Practice · doi:10.1016/j.prp.2024.155714 · Cited by 6
Zhang, Y., Xie, Y., Zhang, C., Wang, J., Liao, B., & Feng, J. (2024) · Current Vascular Pharmacology · doi:10.2174/0115701611328810241028112700 · Cited by 5
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to determine the risk of bias, which is recommended for diagnostic study evaluation by the Cochrane Handbook [25].”
A Systematic Review Evaluating Methods for Diagnosis, Treatment and Prevention of Dental Erosions
Jarkander, M. S., Domeij, H., Edebert, I., Ástvaldsdóttir, Á., Grindefjord, M., & Johannsen, A. (2024) · International Journal of Dental Hygiene · doi:10.1111/idh.12876 · Cited by 4
Pitcher, M. J., Moulson, A., Pitcher, D., Herbland, A., Cert, G., & Cairns, M. C. (2024) · Foot & Ankle Orthopaedics · doi:10.1177/24730114241291055 · Cited by 4
“The QUADAS-2 risk of bias tool 48 has been specifically designed for use in systematic reviews of quality of diagnostic accuracy studies and is recommended for such use by Cochrane.”
Gamas, L., Fragão-Marques, M., Zlatanović, P., Andrade, J. P., & Rocha-Neves, J. P. (2024) · Scandinavian Journal of Surgery · doi:10.1177/14574969241282611 · Cited by 5
Myint, T. M., Chong, C. H., Huben, A. V., Attia, J., Webster, A. C., Blosser, C. D., Craig, J. C., Teixeira-Pinto, A. M., & Wong, G. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014839.pub2 · Cited by 4
Yoshimura, S., Hashimoto, K., Shono, Y., Tamura, T., Uchimido, R., Andō, K., Okamori, S., Yoshida, T., Yoshitake, S., & Okada, Y. (2024) · Internal Medicine · doi:10.2169/internalmedicine.4292-24 · Cited by 7
“Two 151 investigators evaluated the risk of bias using the Quality Assessment Tool for Diagnostic 152 Accuracy Studies-2 (QUADAS-2) tool [10], which is widely accepted and includes four 153 risk of bias domains and three domains of applicability.”
Zhang, F., Wang, P., Cao, C., Pan, X., Zhang, T., Fan, M., & Guan, Y. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1502296 · Cited by 4
Pang, J., Gao, Y., Yin, N., & Liu, X. (2024) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2024.12.040 · Cited by 4
Quinteros, P. M. T., Gutierrez, L. V. T., & Yovera-Aldana, M. (2024) · ACTA MEDICA PERUANA · doi:10.35663/amp.2024.413.2925 · Cited by 5
Yu, P., Zhou, X., Li, Y., Zhang, L., Zhou, Y., & Jiang, F. (2025) · BMC Medical Imaging · doi:10.1186/s12880-024-01541-9 · Cited by 4
Wang, C., Zhu, S., & Liang, J. (2025) · Academic Radiology · doi:10.1016/j.acra.2024.12.024 · Cited by 6
Kim, Y. E., Kim, P. H., Yoon, H. M., Lee, J., Jung, A. Y., Cho, Y. A., Oh, S. H., & Kim, K. M. (2025) · Digestive Diseases and Sciences · doi:10.1007/s10620-024-08835-6 · Cited by 4
“The quality of the selected studies was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [5].”
Transtracheal ultrasound for identifying endotracheal intubation in adults
Gottlieb, M. A., Kim, D. J., Peksa, G. D., Westrick, J. C., & Marks, A. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015936 · Cited by 5
“Two review authors (MG, DJK) will independently assess methodological quality using the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) tool (Whiting 2011).”
Tong, Y., Li, P., Liu, W., Tan, S., Wang, X., Zhang, Y., Ran, Y., Fang, Y., Fan, Y., Wei, T., et al. (2025) · Surgical Endoscopy · doi:10.1007/s00464-025-11568-w · Cited by 5
“The methodological quality of the included studies was rigorously evaluated independently by two authors using the modified 15-item Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [19].”
A Perspective on Artificial Intelligence for Molecular Pathologists
O’Leary, T. J., O'Leary, B. J., & O’Leary, D. P. (2025) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2025.01.005 · Cited by 6
Diagnosing portal vein stenosis after pediatric liver transplantation: A systematic review
Alfares, B. A., Verhagen, M. V., Dierckx, R., van der Doef, H. P. J., de Haas, R. J., & Bokkers, R. P. H. (2025) · Transplantation Reviews · doi:10.1016/j.trre.2025.100912 · Cited by 4
Lomer, N. B., Khalaj, F., Ghorani, H., Mohammadi, M., Ghadimi, D. J., Zakavi, S. S., Afsharzadeh, M., & Sotoudeh, H. (2025) · Clinical Imaging · doi:10.1016/j.clinimag.2025.110436 · Cited by 4
Kwan, C.-K., Young, J. H., Lai, J. C.-H., Lai, K. K., Yang, G., Hung, A. L.-H., Chu, C. W., Lau, A. Y.-C., Lee, T. T., Cheng, J. C. Y., et al. (2025) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-025-08467-5 · Cited by 4
“Risk of bias and concerns regarding applicability of each included study were evaluated using the Quality Assessment of Diagnostic Studies-2 (QUADAS-2) instrument (Appendix II) [28].”
A Meta-analysis of 68Ga-FAPI PET in Assessment of Ovarian Cancer
Sun, L., Zheng, L., & Zhang, B. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.02.040 · Cited by 4
Diagnostic accuracy of IgG 4/IgG and IgG 4 in patients with IgG 4-related disease: a meta-analysis
Lee, Y. H., & Song, G. G. (2025) · Zeitschrift für Rheumatologie · doi:10.1007/s00393-025-01637-9 · Cited by 4
“The quality of each study was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) [18].”
Jin, Y., & Zhou, C. (2025) · Clinical Radiology · doi:10.1016/j.crad.2025.106868 · Cited by 4
Kolańska, K., Zerbib, E., Dabi, Y., Chabbert‐Buffet, N., d’Argent, E. M., Favier, A., Ferrier, C., Touboul, C., Hamamah, S., & Daraï, É. (2025) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2025.104957 · Cited by 4
Anagnostopoulos, I., Vrachatis, D. A., Kousta, M. S., Giotaki, S. G., Katsoulotou, D., Karavasilis, C., Deftereos, G., Schizas, N. C., Avramidis, D., Γιαννόπουλος, Γ., et al. (2025) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd12040122 · Cited by 9
Hajikarimloo, B., Tos, S. M., Kooshki, A., Alvani, M. S., Eftekhar, M. S., Hasanzade, A., Tavanaei, R., Akhlaghpasand, M., Hashemi, R., Ghaffarzadeh-Esfahani, M., et al. (2025) · Neuroradiology · doi:10.1007/s00234-025-03597-y · Cited by 4
“The Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2) was utilized to assess the risk of bias assessment (ROB) of the included studies [26].”
Dessau, R. B., Raffetin, A., Eikeland, R., Fingerle, V., Henningsson, A. J., Hunfeld, K., Jaulhac, B., Lienhard, R., Lindgren, P., Markowicz, M., et al. (2025) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2025.04.001 · Cited by 4
Shinohara, Y., Yamaguchi, M., Wannous, M., Luo, Y., Yamamoto, K., & Sato, M. (2025) · BMC Pulmonary Medicine · doi:10.1186/s12890-025-03649-2 · Cited by 4
“The Quality Assessment of Diagnostic Accuracy Studies tool was proposed in 2003 and updated in 2011 [10].”
Hsiao, K., Lin, H.-L., Chen, H., & Chen, C. (2025) · International Journal of Gynecological Cancer · doi:10.1016/j.ijgc.2025.101904 · Cited by 5
Hidayat, R., Audrey, J., Tandaju, J. R., & Fauzia, F. (2025) · Rheumatology & autoimmunity · doi:10.1002/rai2.70008 · Cited by 4
Santos, M. S. N. D., & Stayt, L. C. (2025) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2025.104048 · Cited by 4
Chen, I., Wang, W.-T., Wu, J., Yu, C., Chang, Y.-J., & Hung, K. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1532253 · Cited by 4
Yu, J., Shen, Y., Xu, Y., Feng, Z., Shen, Y., Zhu, Y., Huan, J., & Peng, Q. (2025) · BMC Medical Genomics · doi:10.1186/s12920-025-02158-9 · Cited by 4
“Each domain was rated as low, high, or unclear risk of bias based on predefined criteria [11].”
Salieti, H. A., Qasem, H. M., Alshwayyat, S., Almasri, N., Alshwayyat, M., Aboali, A. A., Alsarayrah, F., Khasawneh, L., & Al‐kurdi, M. A. (2025) · Frontiers in Dental Medicine · doi:10.3389/fdmed.2025.1534406 · Cited by 4
Diagnostic Value of 18 F-FDG PET/CT Radiomics in Lymphoma: A Systematic Review and Meta-Analysis
Liu, C., Zhao, J., Zhang, H., & Ni, X. (2025) · Technology in Cancer Research & Treatment · doi:10.1177/15330338251342860 · Cited by 5
“15 This tool includes four domains in terms of risk of bias (patient selection, index test, reference standard, as well as fl ow and timing) and three domains in terms of applicability concerns (patient selection, index test, and reference standard).”
Hwang, A., Rashid, S., Shi, S., Blew, C., Levine, M., & Saha, A. (2025) · Current Oncology · doi:10.3390/curroncol32060300 · Cited by 4
“A tailored QUADAS-2 assessment tool [20] was developed a priori and used to assess the risk of bias and applicability of the included articles, under four domains: patient selection, index test, reference standard, and flow and timing (Supplemental S2).”
Aghayan, A. H., Mirazimi, Y., Hosseini, Z. S., & Rafiee, M. (2025) · Journal of Research in Medical Sciences · doi:10.4103/jrms.jrms_287_24 · Cited by 4
“[13] With the QUADAS‑2 tool, four key domains were evaluated, including patient selection, index test, reference standard, flow, and timing.”
Fathi, A., Heidari, M., Rasouli, J., & Ghasemnejad‐Berenji, H. (2025) · BMC Women s Health · doi:10.1186/s12905-025-03766-4 · Cited by 4
“Additionally, it evaluates applicability concerns in three domains, including Patient Selection, Index Test, and Reference Standard [24].”
Byrne, A., Pace, N. L., Thomas, P. S., Symons, R. G., Chatterji, R., & Bennett, M. H. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010841.pub2 · Cited by 4
Lasne, D., Testa, S., Kitchen, S., Gardiner, C., Meijer, P., & Mullier, F. (2025) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.14506 · Cited by 5
Lee, S.-W., Jeong, S. Y., & Kim, S. (2025) · Annals of Nuclear Medicine · doi:10.1007/s12149-025-02075-y · Cited by 4
“Quality of the included studies was assessed based on 15-item modified Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [12].”
He, Z., Liu, M., Ying, P., Song, M., & Tan, X. (2025) · Heart · doi:10.1136/heartjnl-2025-325916 · Cited by 4
“14 Disagreements in study selection, data extraction or methodological quality assessment were settled through discussion, or by consulting a third review author as an arbitrator.”
PET imaging and radionuclide therapy in neuroendocrine prostate cancer: a systematic review
Abdlkadir, A. S., Al-Adhami, D. A., Al-Rasheed, U., Jreige, M., Mahafza, W. S., Alkhawaldeh, K. M., Estrada-Lobato, E., & Al‐Ibraheem, A. (2025) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.25.03638-6 · Cited by 4
Singh, T., Jha, S., Bhatt, N., Handa, P., Goel, N., & Indu, S. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.111659 · Cited by 5
Fácila, L., Vidal-Pérez, R., Benedito, M., Andreu, M. L. S., Cervantes, C. E., & Fort, A. C. (2025) · REC CardioClinics · doi:10.1016/j.rccl.2025.07.001 · Cited by 4
Poursalehian, M., Farsani, A. S., Irani, P. T., Firoozabadi, M. A., Parvizi, J., & Mortazavi, S. M. J. (2025) · Arthroplasty · doi:10.1186/s42836-025-00325-y · Cited by 4
“The quality of the studies was assessed using the QUADAS-2 tool [28].”
Mojahedi, A., Kalogeropoulos, A. P., Chen, O., & Skopicki, H. A. (2025) · Reviews in Cardiovascular Medicine · doi:10.31083/rcm36643 · Cited by 4
“To determine the possibility of bias in each of the evaluated studies, the QUADAS-2 instrument was used to evaluate the population, technique, analysis, and reporting requirements of each study [ 24].”
Faltinsen, E. G., Østengaard, L., Boutron, I., Stewart, L. A., Hróbjartsson, A., & Lundh, A. (2025) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2025.112003 · Cited by 5
Nayana, M. A., Avinash, J. L., Jayachandra, M. Y., Bhat, P. K., Kumar, S., & Bhuyan, L. (2025) · Journal of International Society of Preventive and Community Dentistry · doi:10.4103/jispcd.jispcd_116_25 · Cited by 4
Klopper, G. J., & Adeniyi, O. V. (2025) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-025-09773-3 · Cited by 4
“The methodological quality of the included studies, assessed using the QUADAS-2 tool [28 ], is presented in Table 2 ; Fig.”
InfluentialElsaigh, M., Baqar, S., Awan, B., Saleh, O. S., Gamal, M. H., Abara, N., Hawkins, A., & Beqo, B. P. (2025) · Cureus · doi:10.7759/cureus.95484 · Cited by 4
“…potential bias across four key areas as follows: patient selection methods, the diagnostic test being evaluated, the reference standard used for comparison, and study flow and timing, along with three additional domains that assess the applicability of the findings to our research question [17].”
Radiolabeled LHRH and FSH Analogues as Cancer Theranostic Agents: A Systematic Review
Giorgio, A., Varani, M., Lauri, C., Bentivoglio, V., & Nayak, P. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14217811 · Cited by 4
Yin, M., Dai, J., Sun, R., & Wang, Y. (2025) · Annals of Medicine · doi:10.1080/07853890.2025.2583319 · Cited by 4
“We assessed the quality of each included study using the QUADAS-2 assessment tool [14], and as shown in Figure 5, all seven studies showed a low risk of bias, indicating a relatively high overall quality of the included analyses.”
Rani, S., Gao, E. Y., Ong, J. Z. E., Tan, N. K. W., Ng, A. C. W., Leong, Z. H., Phua, C. Q., Ong, T. H., Leow, L. C., Huang, G.-B., et al. (2025) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-025-09808-9 · Cited by 6
Howlett, P. J., Durairaj, A., Lesosky, M., & Feary, J. R. (2025) · Occupational and Environmental Medicine · doi:10.1136/oemed-2024-110000 · Cited by 4
“While we applied our risk of bias tool according to the guidance 13 and have attempted to do so transparently (including publication of our raw data), we felt the QUADAS-2 may overestimate risk of bias in some cases.”
Duplex ultrasound for the diagnosis of symptomatic deep vein thrombosis in the lower limb
Chappell, F. M., Crawford, F., Andras, A., Goodacre, S. W., McCaslin, J. E., Welch, K., & Oates, C. P. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010930 · Cited by 4
van Gruting, I. M. A., Stankiewicz, A., Thakar, R., IntHout, J., Santoro, G. A., & Sultan, A. H. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011482 · Cited by 5
Manterola, C., Otzen, T., Lorenzini, N., Díaz, A., Torres-Quevedo, R., & Claros, N. (2013) · International Journal of Morphology · doi:10.4067/s0717-95022013000300029 · Cited by 4
STARD guideline in diagnostic accuracy tests: perspective from a systematic reviewer.
Hu, Z.-D. (2016) · PubMed Central · doi:10.3978/j.issn.2305-5839.2016.01.03 · Cited by 4
Meta-analysis of microRNAs as biomarkers for muscle-invasive bladder cancer
Zheng, L., & Sun, W. (2016) · Biomedical Reports · doi:10.3892/br.2016.705 · Cited by 4
Assessment of the Utility of Cognitive Screening Instruments
Quinn, T. J., & Takwoingi, Y. (2016) · Springer eBooks · doi:10.1007/978-3-319-44775-9_2 · Cited by 6
Checklin, M., & Pizzari, T. (2018) · Dysphagia · doi:10.1007/s00455-018-9902-y · Cited by 5
Reporting Guidelines for Imaging Research
McInnes, M. D. F., Lim, C. S., van der Pol, C. B., Salameh, J., McGrath, T. A., & Frank, R. A. (2018) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2018.11.008 · Cited by 7
Zervikaler „joint position error“ bei Kopfschmerzen
Meise, R., Lüdtke, K., Probst, A., Stude, P., & Schöttker-Königer, T. (2019) · Der Schmerz · doi:10.1007/s00482-019-0369-z · Cited by 4
PET/PET-CT Evidenz zum Bedarf und zur Planung in Deutschland und Österreich: Update 2018
Fuchs, S., Grössmann, N., Eckhardt, H., Busse, R., & Wild, C. (2019) · DepositOnce · doi:10.14279/depositonce-7574 · Cited by 4
Fan, M., Meng, L., Shi, H., Wang, W., Han, C., Hou, X., Ding, Z., & Lin, R. (2020) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-020-03199-6 · Cited by 4
Hussain, M. L., Hamid, P., & Chakane, N. (2020) · Biomarkers · doi:10.1080/1354750x.2020.1777199 · Cited by 4
Niculescu, I., Arora, T., & Iaboni, A. (2020) · Aging & Mental Health · doi:10.1080/13607863.2020.1793899 · Cited by 6
Diagnostic and prognostic factors in patients with prostate cancer: a systematic review protocol
Beyer, K., Moris, L., Lardas, M., Haire, A., Barletta, F. M., Scuderi, S., Vradi, E., Gandaglia, G., Omar, M. I., MacLennan, S., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-040531 · Cited by 7
Delirium screening tools in the emergency department
Zhang, Q., Li, S., Chen, M., Yang, Q., Cao, X. Q., Ge, L., & Di, B. (2021) · Medicine · doi:10.1097/md.0000000000024779 · Cited by 4
Santos, F. D. S., Verma, N., Watte, G., Marchiori, E. D. S., Mohammed, T.-L. H., Medeiros, T. M., & Hochhegger, B. (2021) · Radiologia Brasileira · doi:10.1590/0100-3984.2020.0084 · Cited by 4
Liu, F., Wu, X., Zhu, H., & Wang, F. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-044267 · Cited by 4
Bhatta, M., Banerjee, S., Nandi, S., Dutta, S., & Saha, M. K. (2021) · Journal of Clinical Virology · doi:10.1016/j.jcv.2021.105047 · Cited by 4
Diagnostic and prognostic value of Bcl-2 in uterine leiomyosarcoma
Travaglino, A., Raffone, A., Raimondo, D., Gencarelli, A., Esposito, I., Gallo, C., Improda, F. P., Vitale, S. G., Mollo, A., Casadio, P., et al. (2022) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-022-06531-2 · Cited by 4
Jiang, Y., & Qi, S. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.878946 · Cited by 4
Aggarwal, A. N., Agarwal, R., Dhooria, S., Prasad, K. T., Sehgal, I. S., & Muthu, V. (2022) · Lung India · doi:10.4103/lungindia.lungindia_738_21 · Cited by 4
Instrumentos de rastreio da disfagia pós-intubação prolongada: revisão sistemática da literatura
Azevedo, P., Saraiva, M., Oliveira, M., & Oliveira, I. (2023) · Revista Portuguesa de Enfermagem de Reabilitação · doi:10.33194/rper.2023.264 · Cited by 4
Ssedyabane, F., Niyonzima, N., Ngonzi, J. N. J., Tusubira, D., Ocan, M., Akena, D. H., Namisango, E., Apunyo, R., Kinengyere, A. A., & Obuku, E. A. (2023) · Diagnostic and Prognostic Research · doi:10.1186/s41512-023-00142-4 · Cited by 4
Rana, D. R., & Pokhrel, N. (2023) · Journal of Helminthology · doi:10.1017/s0022149x2200092x · Cited by 4
Chen, H., Li, B., Xiao, Y., Wang, H., Kuang, M., Sun, H., & Yang, L. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285508 · Cited by 4
Clinical Applications of Conebeam CTP Imaging in Cerebral Disease: A Systematic Review
Al-Kaylani, A. H. A. Z., Schuurmann, R. C. L., Maathuis, W. D., Slart, R. H. J. A., de Vries, J. P. P. M., & Bokkers, R. P. H. (2023) · American Journal of Neuroradiology · doi:10.3174/ajnr.a7930 · Cited by 4
Gandhi, T., Shah, A., Gautam, N., & Meena, N. K. (2023) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2023.07.010 · Cited by 5
Association of EDN levels in patients with asthma and correlation with FEV1%: A meta-analysis
Kuai, S., & Zhao, P. (2023) · Allergy and Asthma Proceedings · doi:10.2500/aap.2023.44.230016 · Cited by 4
Pinho, J., & Correia-Coelho, D. A. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01056-8 · Cited by 4
A guide to conducting systematic reviews of clinical laboratory tests
Don-Wauchope, A., Rodríguez-Capote, K., Assaad, R. S., Bhargava, S., & Zemlin, A. E. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0333 · Cited by 4
Li, Y., Fang, D., & Wu, Q. (2023) · PLoS ONE · doi:10.1371/journal.pone.0278800 · Cited by 4
Reddy, R. P., Gorijala, V. K., Kaithi, V. R., Shandal, V., Anetakis, K., Balzer, J. R., Crammond, D. J., Shaw, J. D., Lee, J. Y., & Thirumala, P. D. (2023) · European Spine Journal · doi:10.1007/s00586-023-07879-y · Cited by 7
Naik, S., Gupta, P., Khaitan, T., & Shukla, A. K. (2023) · Journal of Indian Academy of Oral Medicine and Radiology · doi:10.4103/jiaomr.jiaomr_31_22 · Cited by 4
MRI for the detection of small malignant renal masses: a systematic review and meta-analysis
Shang, W., Hong, G., & Li, W. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1194128 · Cited by 4
Giri, S. (2023) · Annals of Gastroenterology · doi:10.20524/aog.2023.0831 · Cited by 4
Sanders, S., Barratt, A. L., Buchbinder, R., Doust, J. A., Kazda, L., Jones, M., Glasziou, P., & Bell, K. (2023) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2023.11.005 · Cited by 16
Borg, S. A., Cao, J., Nguyen, P., Aziz, S., & Vogel, J. P. (2023) · BMC Medicine · doi:10.1186/s12916-023-03186-x · Cited by 4
Diagnostic performance of GcfDNA in kidney allograft rejection: a meta-analysis
Yang, H., Wang, D., Sun, X., Wang, H., Lan, Y., & Wei, L. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2023.1293402 · Cited by 4
Fiz, F., Piticchio, T., Bottoni, G., Sorrentino, S., Fragola, M., Livellara, V., Trimboli, P., & Piccardo, A. (2024) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.24.03552-0 · Cited by 5
Zhou, X., Hu, C., Pan, J., Xu, C., Xu, Z., Pan, T., & Chen, B. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1350847 · Cited by 4
Shen, L., Altmayer, S., & Tse, J. R. (2024) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.29279 · Cited by 4
“…certain subtypes of HCAs), 37 were excluded due to signal intensity on HBP that was not extractable (or not performed) for individual subtypes, 24 were excluded as the studies presented data on other non-HCA liver tumors only, and 2 were excluded as they were conference abstracts without…”
Araújo, D., Martins, J. P., Ferreira, S. L., Mota, S. M. D. S., Ferreira, P. L., & Pimenta, R. E. (2024) · Frontiers in Microbiology · doi:10.3389/fmicb.2024.1361626 · Cited by 4
Muchandifunga Trust Muchadeyi, Hernández-Villafuerte, K., Tanna, G. L. D., Eckford, R. D., Feng, Y., Meregaglia, M., Peasgood, T., Petrou, S., Ubels, J., & Schlander, M. (2024) · PharmacoEconomics · doi:10.1007/s40273-024-01365-z · Cited by 4
“Existing definitions range widely, from the likelihood of generating unbiased results in comparative clinical effectiveness science [61] to including dimensions such as relevance and applicability [62, 63], generalisability and imprecision in other research fields [13, 58, 64–66].”
Łajczak, P. M., Jóźwik, K., & Nawrat, Z. (2024) · Artificial Intelligence Surgery · doi:10.20517/ais.2024.05 · Cited by 4
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.