QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 9,601–9,700 of 14,770
Detecting Anxiety in Long-Term Care Residents: A Systematic Review
Atchison, K., Shafiq, S., Ewert, D., Leung, A. A. C., & Goodarzi, Z. (2022) · Canadian Journal on Aging / La Revue canadienne du vieillissement · doi:10.1017/s0714980822000101 · Cited by 5
“The risk of bias assessment for all included studies was completed independently in duplicate using the Quality Assessment for Diagnostic Accuracy Studies-2 (QUADAS-2) tool (Whiting et al., 2011).”
Ho, L. T. F., Chen, S., Ho, F. F., Wong, C. H. L., Ching, J. Y. L., Cheong, P. K., Wu, X., Liu, X., Leung, T. H., Wu, J. C. Y., et al. (2022) · BMC Gastroenterology · doi:10.1186/s12876-022-02520-6 · Cited by 6
Thompson, J. A., Bertoni, D., Decuzzi, J., Isaiah, A., & Pereira, K. D. (2023) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2023.111485 · Cited by 5
Huang, Z., Liu, W., Li, T., Liu, Z., & Zhao, P. (2023) · Medicine · doi:10.1097/md.0000000000032963 · Cited by 5
Gao, D., Lu, L., & Zhao, Z. (2023) · International Urology and Nephrology · doi:10.1007/s11255-023-03561-w · Cited by 5
Duan, Y., Dong, B., Li, S., & Zhang, C. (2023) · Expert Review of Gastroenterology & Hepatology · doi:10.1080/17474124.2023.2196402 · Cited by 6
Yang, S., Su, F., Jia, H.-R., Liu, C., Lu, Q.-D., Yang, Y., Liu, Y., Wang, J.-J., & Jie, Q. (2023) · Frontiers in Pediatrics · doi:10.3389/fped.2023.1124123 · Cited by 5
The influence of Spanish language on autism spectrum disorder screening: a systematic review
Morgan, C. H., Abdul-Chani, M. M., Sherrod, G., King, K. P., & Guest, K. C. (2023) · International Journal of Developmental Disabilities · doi:10.1080/20473869.2023.2193490 · Cited by 5
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2; Whiting et al. 2011) was used to evaluate risk of bias and applicability concerns related to patient selection, index tests, reference standard, and flow and timing in cross-sectional studies evaluating ASD screening measures.”
Sun, H., Lv, Q., Liu, T., Zhang, N., & Shi, F. (2023) · Scottish Medical Journal · doi:10.1177/00369330231178910 · Cited by 6
RetractedStürzlinger, H., Conrads‐Frank, A., Eisenmann, A., Invansits, S., Jahn, B., Janžič, A., Jelenc, M., Kostnapfel, T., Mencej-Bedrač, S., Mühlberger, N., et al. (2023) · German medical science · doi:10.3205/000320 · Cited by 19
Point-of-Care HIV and Syphilis Screening
Brett, K., & Askin, N. (2023) · Canadian Journal of Health Technologies · doi:10.51731/cjht.2023.689 · Cited by 5
Tang, C., Ruan, R., & Xiong, Z. (2023) · Clinical and Translational Imaging · doi:10.1007/s40336-023-00585-1 · Cited by 5
Matushita, C. S., Coelho, F. F., Stasiak, C. E. S., Rodrigues, D. D. M., Pianta, D. B., Kurkowski, F. D., da Silva, M. M., de Souza, S. A. L., Lopes, R. W., & Rosado-de-Castro, P. H. (2023) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.2023s116 · Cited by 5
Diagnostic clinical prediction rules for categorising low back pain: A systematic review
Hill, C., Banerjee, A., Hill, J. C., & Stapleton, C. H. (2023) · Musculoskeletal Care · doi:10.1002/msc.1816 · Cited by 5
Luo, Y., Mao, M., Fan, W., Kang-hua, M., Chang, J., & Xiang, R. (2023) · Acta cardiologica. Supplementum · doi:10.1080/00015385.2023.2250944 · Cited by 5
Hattangadi, N., Kay, T., Parkin, P. C., Birken, C. S., Maguire, J. L., Szatmári, P., van den Heuvel, M., Borkhoff, C. M., & Charach, A. (2023) · Academic Pediatrics · doi:10.1016/j.acap.2023.10.007 · Cited by 5
Association of noncoding RNAs with Kawasaki disease: A meta-analysis based on the current evidences
Zhong, X., Wang, H., Jia, X., Chen, G., Li, H., Li, P., Liu, W., Yang, T., & Xie, J. (2023) · Medicine · doi:10.1097/md.0000000000035736 · Cited by 5
Aryal, S., Sharma, Y., & Prabhu, P. (2023) · The Egyptian Journal of Otolaryngology · doi:10.1186/s43163-023-00542-9 · Cited by 5
Li, X., Stassen, L., Schrotz‐King, P., Zhao, Z., Cardoso, R., Raut, J. R., Bhardwaj, M., & Brenner, H. (2023) · Cancers · doi:10.3390/cancers15235656 · Cited by 5
Eeles, E. M., Tran, D. D., Boyd, J., Tronstad, O., Teodorczuk, A., Flaws, D., Fraser, J. F., & Dissanayaka, N. N. (2023) · Australian Critical Care · doi:10.1016/j.aucc.2023.11.006 · Cited by 5
Rodriguez, D. A., Dahlwi, G., Gould, M. J., MARCON, M. A., & Benninga, M. A. (2024) · Gastrointestinal Disorders · doi:10.3390/gidisord6010006 · Cited by 5
Wen, S. W. C., Borg, M. H., Timm, S., Hansen, T. F., Hilberg, O., & Andersen, R. F. (2024) · Cancers · doi:10.3390/cancers16030506 · Cited by 5
Tian, M., Chen, M., Huang, L., & Liu, Q. (2024) · iScience · doi:10.1016/j.isci.2024.109026 · Cited by 5
Sabater-Martos, M., Ferrer, M., Morata, L., Soriano, À., & Martínez-Pastor, J. C. (2024) · Journal of Bone and Joint Infection · doi:10.5194/jbji-9-17-2024 · Cited by 5
Zhou, H.-Y., Cheng, J.-M., Chen, T., Zhang, X., Ou, J., Cao, J., & Li, H.-J. (2024) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/0115734056256824231204073534 · Cited by 5
Xing, Y., Shi, H., Guo, Q., Wang, C., Li, C., & Hao, C. (2024) · International Journal of Urology · doi:10.1111/iju.15423 · Cited by 7
Kazemian, S., Zarei, D., Bozorgi, A., Nazarian, S., Issaiy, M., Tavolinejad, H., Tabatabaei‐Malazy, O., & Ashraf, H. (2024) · International Journal of Cardiology Cardiovascular Risk and Prevention · doi:10.1016/j.ijcrp.2024.200249 · Cited by 6
Jiao, Y., Huang, M. M. C., Liang, M. M. J.-W., & Lei, M. M. Y.-C. (2024) · Clinics and Research in Hepatology and Gastroenterology · doi:10.1016/j.clinre.2024.102317 · Cited by 7
Liu, L., Liao, H., Zhao, Y., Yin, J., Wang, C., Duan, L., Xie, P., Wei, W., Xu, M., & Su, D. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1267596 · Cited by 7
A Systematic Review of Anti-Adhesion Agents in Hand Trauma
Forbes, M., Cavallaro, D., & Power, D. (2024) · Hand · doi:10.1177/15589447241238374 · Cited by 7
“Finally, the risk of bias tool used to assess the non-randomized studies in our report was the ROBINS-I tool, 15 rather than the originally planned QUADAS-2 tool, 37 based on the Cochrane recommendations for tools to assess bias.”
A meta-analysis of UCA1 accuracy in the detection of bladder cancer
He, S., Xu, J., Chen, M., Li, J., Li, S., & Ye, J. (2024) · Expert Review of Anticancer Therapy · doi:10.1080/14737140.2024.2342528 · Cited by 5
Noncontact respiration monitoring techniques in young children: A scoping review
van der Linden, M., Veldhoen, E. S., Arasteh, E., Long, X., Alderliesten, T., de Goederen, R., & Dudink, J. (2024) · Pediatric Pulmonology · doi:10.1002/ppul.27028 · Cited by 5
Li, J., Zhu, Y., Ni, J.-R., Wang, L., & Lei, J. (2024) · Diagnostic and Interventional Radiology · doi:10.4274/dir.2024.242723 · Cited by 8
Fernandes, D. A., Martins, E. C., Melo, G., Locks, R., Adam, G. P., & Neves, F. S. (2024) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0000000000001229 · Cited by 7
Du, F., Zhang, X., Zheng, X.-L., Zhang, R., & Wang, Q. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-078527 · Cited by 5
Fan, S., Zhang, H., Meng, Z., Li, A., Luo, Y., & Liu, Y. (2024) · Journal of Clinical Pathology · doi:10.1136/jcp-2024-209597 · Cited by 5
Vikram, S., Robinson, J., Thanawala, T., Franklin, J. D., Boeckstaens, S., Hall, M., Sanusi, F. A., PADWICK, M. L., & Stanciu, P. I. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014568 · Cited by 11
Musco, H., Beecher, K., Chand, K. K., Boyd, R. N., Colditz, P. B., & Wixey, J. A. (2024) · Frontiers in Pediatrics · doi:10.3389/fped.2024.1396102 · Cited by 5
Ultrasound in bone fracture diagnosis – a comparative meta-analysis and systematic review
Matschiner, E., Şerban, O., Fodor, D., Blaivas, M., Horn, R., Koch, J., Jakobi, M.-L., Grevelding, L., Osterwalder, J. J., Srivastava, D., et al. (2024) · Medical Ultrasonography · doi:10.11152/mu-4407 · Cited by 9
Hu, Y., Zhang, L., Zhang, H., Zhang, B., Yang, J., & Li, R. (2024) · Medicine · doi:10.1097/md.0000000000038721 · Cited by 5
Fomenko, A., Dähne, T., Weibel, S., Panning, M., Grummich, K., Schlesinger, S., Rücker, G., & Hengel, H. (2024) · Reviews in Medical Virology · doi:10.1002/rmv.2569 · Cited by 6
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS ‐ 2) tool has been used in studies with single index test, 31 while in comparative DTA studies we additionally used QUADAS ‐ C. 32 In both tools signalling questions are incorporated that allow for the assessment of risk of bias and…”
Canali, L., Costantino, A., Mari, G., Festa, B. M., Russo, E., Giannitto, C., Spriano, G., & VIRGILIO, A. D. (2024) · Otolaryngology · doi:10.1002/ohn.949 · Cited by 5
Gopal, S. H., Zebda, R., Mohan, A., Borovsky, K. A., Takwoingi, Y., Scandrett, K., & Pammi, M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0307837 · Cited by 5
Wang, C., Zhou, L., Zhou, F., & Fu, T. (2024) · Neurological Sciences · doi:10.1007/s10072-024-07731-1 · Cited by 8
Clinical Utility of Ocular Assessments in Sport-Related Concussion: A Scoping Review
Walshe, A., Daly, E., & Ryan, L. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9030157 · Cited by 6
“The revised tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used to assess diagnostic accuracy across four domains (patient selection, index tests, reference standards, flow and timing) related to the risk of bias and applicability concerns of studies [28].”
MethodLu, Y.-A., Chuang, Y., Huang, T., & Gautama, M. S. N. (2024) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2024.104496 · Cited by 5
Li, T., Isautier, J., Lee, J. M., Marinovich, M. L., & Houssami, N. (2024) · Clinical Breast Cancer · doi:10.1016/j.clbc.2024.09.013 · Cited by 5
Yuan, J., Chen, X., Liu, C., & Yan, R. (2024) · Discover Oncology · doi:10.1007/s12672-024-01234-3 · Cited by 5
“…abstracts, speeches, or partial content missing; (II) individuals suffering from various benign and malignant conditions that could impact the expression level of serum HE4; and (III) studies that received a low score on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) [8].”
BackgroundRibeiro, I., Woods, L., Maund, E., Scott, D. A., Lord, J., Picot, J., & Shepherd, J. (2024) · Health Technology Assessment · doi:10.3310/zktw8214 · Cited by 10
Aggarwal, P., Gunasekaran, V., Singh, H., Kumar, R., Satapathy, S., & Mittal, B. R. (2024) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000005501 · Cited by 13
Pape, S., Gulma, K. A., Shivalli, S., & de Kiev, L. C. (2024) · Journal of Medicine and Life · doi:10.25122/jml-2024-0155 · Cited by 5
Rizzo, A., Albano, D., Marchiò, C., Dondi, F., Racca, M., Bertagna, F., Fiz, F., Piccardo, A., & Treglia, G. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252111413 · Cited by 6
“This systematic review was performed according to a predefined protocol [18], and the “Preferred Reporting Items for a Systematic Review and Meta-Analysis” (PRISMA 2020 statement) was employed as a guide in its development [19].”
MethodBaana, M., Arkwazi, M., Zhao, Y., Ofagbor, O., Bhardwaj, G., Lami, M., Bolton, E. M., & Heer, R. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-089125 · Cited by 5
Meta-analysis of the diagnostic value of exosomal microRNAs in renal cell carcinoma
Li, Q., Tian, J., Chen, C., Liu, H. S., & Li, B. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1441429 · Cited by 5
Shabaninejad, H., Kenny, R. P. W., Robinson, T., Stoniute, A., O’Keefe, H., Still, M., Thornton, C., Pearson, F., Beyer, F. R., & Meader, N. (2024) · Health Technology Assessment · doi:10.3310/tgac4201 · Cited by 5
Acker, L. V., Toribio, L. M., Chachage, M., Zeng, H., Devleesschauwer, B., García, H. H., & Gabriël, S. (2024) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0012643 · Cited by 5
Antemortem diagnostic tests for the detection of Aspergillus infection in birds: A systematic review
Vieu, S., Guillot, J., & Beaudeau, F. (2024) · Medical Mycology · doi:10.1093/mmy/myae112 · Cited by 5
Willems, S. A., van Bennekom, O. O., Schepers, A., van Schaik, J., van der Vorst, J. R., Hamming, J. F., & Brouwers, J. J. W. M. (2024) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2024.10.021 · Cited by 5
Chen, C.-C., Chen, Y., Kuo, Y., Liu, Y., & Huang, S.-W. (2024) · EFORT Open Reviews · doi:10.1530/eor-23-0206 · Cited by 5
Antimicrobial properties of denture adhesives: A scoping review
An, S., Yaparathna, N., Evans, J. L., & Love, R. M. (2024) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2024.11.007 · Cited by 5
O’Connor, A. D., Rengifo, C., Griffiths, B., Cornish, J. A., Tiernan, J. P., Khan, J. S., Nunoo-Mensah, J. W., Telford, K., & Harji, D. P. (2024) · Techniques in Coloproctology · doi:10.1007/s10151-024-03043-w · Cited by 6
“The risk of bias was assessed using the The Cochrane Collaboration-recommended QUADS-2 tool for diagnostic accuracy studies [23] by two independent blinded researchers (AOC & CR).”
Diagnosis of bicuspid aortic valves: CT vs. TTE
Sylivris, A., Liu, Z. F., Theuerle, J. D., & Lim, R. (2024) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-024-03290-w · Cited by 5
“Quality assessment was performed by two independent reviewers (AS and ZL) using the QUADAS-2 tool, which has been specifically designed for diagnostic accuracy stud - ies [26 ].”
Vatteroni, G., Dietzel, M., & Baltzer, P. (2024) · European Radiology · doi:10.1007/s00330-024-11274-6 · Cited by 5
“B) selected eligible studies and extracted the data into a prede fi ned Excel spreadsheet, and assessed the risk of bias and applicability concerns according to Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 [18].”
da Costa, G. D. F. S., Petroski, G. T., Machado, L. G., Santos, B. E., Ramos, F. D. O., Neto, L. M. F., & Canto, G. D. L. (2024) · Abdominal Radiology · doi:10.1007/s00261-024-04771-1 · Cited by 5
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [18] was used to assess the risk of bias in the included studies.”
Dondi, F., Gatta, R., Gazzilli, M., Bellini, P., Viganò, G. L., Ferrari, C., Pisani, A. R., Rubini, G., & Bertagna, F. (2025) · Information · doi:10.3390/info16010058 · Cited by 6
Zhou, T., Han, X., Xiao, C., Lei, X., Lan, X., Wei, X., Liang, Y., & Wu, H. (2025) · European Radiology · doi:10.1007/s00330-024-11344-9 · Cited by 5
“The same two reviewers independently evaluated the quality of the included literature using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2), which consisted of four key domains in the risk of bias: patient selection, index test, reference standard, and fl ow and timing [18].”
Diagnostic Accuracy of Breath Tests to Detect Pulmonary Tuberculosis: A Systematic Review
Chew, N., Yun, S., & See, K. C. (2025) · Lung · doi:10.1007/s00408-024-00779-y · Cited by 6
“Risk-of-bias was assessed using the QUADAS-2 tool [15].”
Performance of ultrasound in detecting fetal hypospadias during pregnancy: a pooled analysis
Zhang, Q., Chen, H., Wang, C., Liu, Z., Wei, G., Zhang, Z., & Liu, X. (2025) · EClinicalMedicine · doi:10.1016/j.eclinm.2025.103091 · Cited by 5
“16 In case any discrepancies remain, they are resolved by seeking a third opinion (HGW, CZZ, XL).”
Edwards, A., Agarwal, R., Bates, J., Bray, A., Milosevic, S., Thomas‐Jones, E., Drinnan, M. J., Drake, M. J., Mitchell, P. J., Pell, B., et al. (2025) · Health Technology Assessment · doi:10.3310/rgtw5711 · Cited by 7
Chen, Y., Zhang, X., Bi, J., & Wang, J. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.01.011 · Cited by 5
Inggriani, S., Rahmawati, D. L., & Octavius, G. S. (2025) · Radiography · doi:10.1016/j.radi.2025.01.019 · Cited by 5
Chou, Y.-J., Chang, C., & Tsai, Y. (2025) · European Urology Open Science · doi:10.1016/j.euros.2025.02.002 · Cited by 5
“All included studies were assessed for the risk of bias and applicability using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [16].”
Li, C., Chen, Y., Gao, Y., & Duan, Y. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112108 · Cited by 7
Zorzato, P. C., Garzon, S., Bosco, M., Ferrari, F. A., Magni, F., Laterza, R. M., Laganà, A. S., Fanfani, F., & Uccella, S. (2025) · Medicina · doi:10.3390/medicina61040699 · Cited by 6
Bai, Z., Xu, L., Ding, Z., Cao, Y., Wang, Z., Yang, W., Xu, W., & Li, H. (2025) · European Radiology · doi:10.1007/s00330-025-11519-y · Cited by 5
“To thoroughly evaluate the quality of the included studies, we adapted a widely recognized tool, the modi fi ed quality assessment of diagnostic accuracy studies (QUADAS-2) tool [22].”
Sesti, F. F., Feola, T., Dolce, P., Guarnotta, V., Veresani, A., Guadagno, E., Bottiglieri, F., Tarsitano, M. G., Isidori, A. M., Colao, A., et al. (2025) · European Thyroid Journal · doi:10.1530/etj-24-0347 · Cited by 5
“The risk of bias was independently assessed for all studies by two reviewers (T F and F S) involved in study selection and extraction using the Quality Assessment of Diagnostic Accuracy Study-2 (QUADAS-2) tool (26).”
Machine Learning Models for Predicting Mortality in Hemodialysis Patients: A Systematic Review
Motofelea, A. C., Mihăescu, A., Olariu, N., Marc, L., Chisavu, L. A., Pop, G. N., Crintea, A., Jura, A. M. C., Ivan, V. M., Apostol, A., et al. (2025) · Applied Sciences · doi:10.3390/app15105776 · Cited by 5
Kumaran, R., Abdalla, M. M. I., Caszo, B. A., & Somanath, S. D. (2025) · PLoS ONE · doi:10.1371/journal.pone.0324251 · Cited by 5
Ali, S. G., Yang, X., Masood, S., Ghazanfar, Z., Jung, Y., Chen, T., & Wang, X. (2025) · The Visual Computer · doi:10.1007/s00371-025-04024-2 · Cited by 6
“For studies evaluating the diagnostic accuracy of AI models (e.g., detecting DR/DME), the QUADAS-2 tool [99] was applied.”
Fan, W., Wu, Z., Zhao, W., Jia, L., Li, S., Wei, W., & Chen, X. (2025) · Annals of Medicine · doi:10.1080/07853890.2025.2515473 · Cited by 5
“This new evaluation method is a specific extension of artificial intelligence to QUADAS-2 [21] and QUADAS-c [22], providing researchers with a specific framework to evaluate the risks of bias and applicability when reviewing the accuracy of diagnostic tests centred on AI.”
Blyth, U., Fourie, H., Akinola, L., Smith, C. S., Melo, P., & Granne, I. (2025) · Human Fertility · doi:10.1080/14647273.2025.2522054 · Cited by 5
“The risk of bias was assessed using QUADAS-2 (Whiting et al., 2011).”
Din, N. U., Maronnat, F., Zolnowski‐Kolp, V., Otmane, S., & Belmin, J. (2025) · Age and Ageing · doi:10.1093/ageing/afaf204 · Cited by 7
“The quality of the selected articles was assessed by two authors (N.U.D., F.M.) using the Quality Assessment of Diagnostic Accuracy Studies 2 instr ument (QUADAS-2) [12] which evaluates the risk of bias and applicability of diagnostic accuracy studies.”
What is the Utility of Point-of-Care Ultrasound for Diagnosing Pulmonary Edema?
Jeffers, K., Keim, S. M., Long, B., Gottlieb, M. A., & Adhikari, S. R. (2025) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2025.07.024 · Cited by 6
Appropriate Use Criteria for Molecular Breast Imaging
Dibble, E. H., Vaz, S. C., Arun, B. K., Fowler, A. M., de Geus‐Oei, L., Hunt, K. N., Jain, R. K., Rauch, G. M., Teshome, M. K., & Covington, M. F. (2025) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.125.270865 · Cited by 5
Predictive accuracy of surgeon gestalt for adverse postoperative outcomes: systematic review
Yang, J. J., Mullan, S. J., Rayhan, T. M., Sandhu, C., Ramaiya, A. N., & Heneghan, C. J. (2025) · British journal of surgery · doi:10.1093/bjs/znaf249 · Cited by 5
Contribution of PET–CT in radiotherapy planning of oesophageal carcinoma: A review
Cheung, G. S. M. (2013) · Radiography · doi:10.1016/j.radi.2013.01.002 · Cited by 5
Coenen, M., Schuetz, G. M., & Dewey, M. (2013) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0033-1350140 · Cited by 8
Inadequate critical appraisal of studies in systematic reviews of time to diagnosis
Launay, E., Cohen, J. F., Morfouace, M., Guen, C. G., Ravaud, P., & Chalumeau, M. (2016) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2016.03.013 · Cited by 5
Fractional flow reserve using computed tomography for assessing coronary artery disease
Panchal, H. B., Veeranki, S. P., Bhatheja, S., Barry, N., Mahmud, E., Budoff, M. J., Lavine, S. J., Mamudu, H. M., & Paul, T. K. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000415 · Cited by 5
Accuracy of ultrasound to detect thrombosis in pregnancy: A systematic review
Castro, A. A., de Lima, F. J. C., de Sousa‐Rodrigues, C. F., & Barbosa, F. T. (2017) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.63.03.278 · Cited by 5
Ritchie, B. K., Porritt, K. A., Marín, T., & Williams, N. (2019) · JBI Evidence Synthesis · doi:10.11124/jbisrir-d-19-00139 · Cited by 6
Corr, M., Waterfield, T., Fairley, D., McKenna, J. P., & Shields, M. D. (2020) · Systematic Reviews · doi:10.1186/s13643-020-01338-1 · Cited by 5
Powers, W. J., Kam, C. H., Ritter, V., & Fine, J. P. (2020) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2020.104849 · Cited by 5
FDG PET correlates weakly with HIF-1 α expression in solid tumors: a meta-analysis
Surov, A., Schmidt, S. A., Prasad, V., Beer, A. J., & Wienke, A. (2020) · Acta Radiologica · doi:10.1177/0284185120932378 · Cited by 5
Sensory descriptors which identify neuropathic pain mechanisms in low back pain: a systematic review
Heraughty, M., & Ridehalgh, C. (2020) · Current Medical Research and Opinion · doi:10.1080/03007995.2020.1790349 · Cited by 6
Zhang, T., Yin, M., Wang, L., Cao, W., & Zhong, S. (2020) · Medicine · doi:10.1097/md.0000000000022594 · Cited by 5
Prognostic value of red blood cell distribution width in patients with acute pulmonary embolism
Liao, Y. H., Yang, C., & Bakeer, B. (2021) · Medicine · doi:10.1097/md.0000000000025571 · Cited by 5
Druce, P., Calanzani, N., Snudden, C. M., Milley, K. M., Boscott, R. A., Behiyat, D., Martínez-Gutiérrez, J., Saji, S., Oberoi, J., Funston, G., et al. (2021) · Advances in Therapy · doi:10.1007/s12325-021-01645-6 · Cited by 5
Chen, Y., Liu, X., & He, L. (2021) · Medicine · doi:10.1097/md.0000000000026036 · Cited by 5
“The risk of bias in the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) score system.([20])”
Seol, H. Y., Kim, Y. S., & Kim, S.-J. (2021) · Clinical Radiology · doi:10.1016/j.crad.2021.06.012 · Cited by 5
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.