QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 9,701–9,800 of 14,770
Akoğlu, E. Ü., & Akoğlu, H. (2021) · Hong Kong Journal of Emergency Medicine · doi:10.1177/10249079211029781 · Cited by 5
Morey, T., Stern, C., Foreman, A., & Hodge, J.-C. (2021) · JBI Evidence Synthesis · doi:10.11124/jbies-21-00164 · Cited by 5
Mardani, M., Rashedi, S., Keykhaei, M., Farrokhpour, H., Azadnajafabad, S., Tavolinejad, H., & Rezaei, N. (2021) · Pathology - Research and Practice · doi:10.1016/j.prp.2021.153726 · Cited by 5
Quality assessment in systematic reviews comparing the diagnostic accuracy of multiple tests
Leeflang, M. (2022) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2022.02.006 · Cited by 5
Self-citationBang, J.-I., & Kang, S. Y. (2022) · Clinical and Translational Imaging · doi:10.1007/s40336-022-00488-7 · Cited by 5
Ferreira, A., Vieira, R., Maia, S., Miranda, V., Parreira, R., & Menéres, P. M. A. M. (2022) · European Journal of Ophthalmology · doi:10.1177/11206721221099777 · Cited by 5
Comparison of Photographic Screening Methods for Diabetic Retinopathy – A Meta-analysis
Yan, W., McGuinness, M. B., Chakrabarti, R., Fotis, K., & Finger, R. P. (2022) · Ophthalmic Epidemiology · doi:10.1080/09286586.2022.2065311 · Cited by 5
Arthur, M., Pichamuthu, K. K., Turaka, V. P., Putta, T., Jeeyavudeen, M. S., Zachariah, A., Sathyendra, S., Hansdak, S. G., Iyadurai, R., Karuppusami, R., et al. (2022) · Postgraduate Medical Journal · doi:10.1136/pmj-2021-141343 · Cited by 5
Accuracy of self-assessment in gastrointestinal endoscopy: a systematic review and meta-analysis
Scaffidi, M. A., Li, J., Genis, S., Tipton, E., Khan, R., Pattni, C., Gimpaya, N., Bradley-Ridout, G., Walsh, C. M., & Grover, S. C. (2022) · Endoscopy · doi:10.1055/a-1929-1318 · Cited by 5
Shin, J., Lee, S., Yoon, J. K., Son, W. J., Roh, Y. H., Chung, Y. E., Choi, J., & Park, M. (2022) · Gut and Liver · doi:10.5009/gnl220115 · Cited by 6
Hidden sources of bias in diagnostic studies: the example of visceral leishmaniasis in east Africa
van Griensven, J., Diro, E., & Yansouni, C. P. (2022) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(22)00643-0 · Cited by 5
Hohlfeld, A., Abdullahi, L. H., Abou-Setta, A. M., & Engel, M. E. (2022) · New Microbes and New Infections · doi:10.1016/j.nmni.2022.101054 · Cited by 5
“There are no validated tools available to assess risk of bias of modelling studies; thus, we used the bespoke assessment tool described previously [1,5].”
Ding, X., Liang, T., Liang, B., Gao, H., Wang, J., Liu, H., Wang, F., Zheng, X., Li, P., Chen, S., et al. (2022) · Medicine · doi:10.1097/md.0000000000031793 · Cited by 5
Truenat MTB assays for pulmonary tuberculosis and rifampicin resistance in adults
Inbaraj, L. R., Daniel, J., Rajendran, P., Bhaskar, A., Srinivasalu, V. A., Narayanan, M. K. S., Shewade, H. D., Kirubakaran, R., Scandrett, K., Muniyandi, M., et al. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015543 · Cited by 8
Wang, P., Lin, T., Su, I.-M., Chang, K. C., Wu, W., & Özçakar, L. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e15458 · Cited by 6
Zhong, J., Xing, Y., Zhang, G., Hu, Y., Ding, D., Ge, X., Pan, Z., Yin, Q., Zhang, H., Yang, Q., et al. (2023) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-023-03863-w · Cited by 8
Zhang, Y., Liu, D., Mao, Y., Gao, Q., & Xiong, T. (2023) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2023-001859 · Cited by 5
Wang, C., Liu, S., Tang, Y., Yang, H., & Liu, J. (2023) · Journal of Medical Internet Research · doi:10.2196/46340 · Cited by 9
“However, QUADAS-2 cannot be evaluated against predictive models for diagnosis or prognosis [22], and to refine this, we further introduced the PROBAST (Prediction Model Risk of Bias Assessment Tool) [23], which is well suited to address DL predictive models for binary outcomes [24].”
Zhang, Q., Yang, S., Zhou, J., Li, Z., Wang, L., & Dong, Q. (2023) · Journal of Laboratory Medicine · doi:10.1515/labmed-2023-0004 · Cited by 5
Wang, Y., Wu, Y., Zhu, M., Tian, M., Liu, L., & Yin, L. (2023) · Diagnostics · doi:10.3390/diagnostics13152497 · Cited by 5
Liu, L., Wang, F., Yan, N., Zou, X., Jiang, D., & Zhong, W. (2023) · Medicine · doi:10.1097/md.0000000000035857 · Cited by 5
Yang, L., Zhou, Z., Wang, J., Lin, Q., Dong, Y., Guo, Z., & Shi, F. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111292 · Cited by 5
Kazma, J. M., Ebner, M. K., Slota, J., Berger, J. S., Farooq, F., Smith, E. R., & Ahmadzia, H. K. (2024) · Perfusion · doi:10.1177/02676591241226465 · Cited by 5
Delniotis, I., Bontinis, V., Ktenidis, K., Drakonaki, E. E., & Galanis, N. (2024) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-024-02451-9 · Cited by 5
“For assessing the risk of bias, judgements are categorized as “low,” “high,” or “unclear” based on the responses “yes,” “no,” or “unclear” to the signaling questions (Supplemental Material 3) [21].”
Waldrop, G. E., Cocuzzo, K., Schneider, C., Kim, C. Y., Goetz, T. G., Chomba, M., DeLaurentis, C., Smithgall, M. C., Francis, R. O., & Thakur, K. T. (2024) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.14236 · Cited by 5
“16 This review was not registered.”
BackgroundPoursalehian, M., Lotfi, M., & Mortazavi, S. M. J. (2024) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-024-05216-6 · Cited by 7
“Four domains comprise the QUADAS-2 instrument: patient selection, index test, reference standard, and flow and timing [30].”
Cao, L., Yang, W., Zhao, X., & Chen, Z. Z. (2024) · Asian Journal of Surgery · doi:10.1016/j.asjsur.2024.02.002 · Cited by 5
Valko, Y., Wirth, M. A., Fierz, F. C., Schesny, M. K., Rosengren, S. M., Meier, T. S., Bockisch, C. J., Straumann, D., Schreiner, B., & Weber, K. P. (2024) · Neurology · doi:10.1212/wnl.0000000000209395 · Cited by 5
Quartuccio, N., Ialuna, S., Pulizzi, S., D’Oppido, D., Nicolosi, S., & Moreci, A. M. (2024) · Tomography · doi:10.3390/tomography10060066 · Cited by 5
Kolahi, S., Tahamtan, M., Sarvari, M., Zarei, D., Afsharzadeh, M., Firouznia, K., & Yousem, D. M. (2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8420 · Cited by 5
Ouyang, T., Tang, Y., Zhang, C., & Yang, Q. (2024) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2023-002198 · Cited by 5
“26 This tool is frequently employed for the assessment of the quality of diagnostic studies.”
MethodZheng, W., Pang, K., Min, Y., & Wu, D. (2024) · Biomedicines · doi:10.3390/biomedicines12081815 · Cited by 10
“…excluded that analyzed VOCs from other bio fl uids including urine, serum, and gastric content, did not analyze VOCs from exhaled breath, and were published before 1990 ( The quality of each study included was assessed using the quality assessment tool for diagnostic accuracy studies (QUADAS-2) [8].”
MethodNiknejad, M. T., Mohajeri, S., Javadrashid, R., Eftekhar, M. S., Shojaeshafiei, F., Baradaran, M., Hatami, B., Klontzas, M. E., & Shahidi, R. (2025) · British Journal of Radiology · doi:10.1093/bjr/tqaf033 · Cited by 5
Carbon dioxide detection for testing nasogastric tube placement in adults
Holland, A., Smith, F., & Penny, K. I. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010773 · Cited by 5
Maheux‐Lacroix, S., Boutin, A., Moore, L., Bergeron, M.-È., Bujold, E., Laberge, P. Y., Lemyre, M., & Dodin, S. (2013) · Systematic Reviews · doi:10.1186/2046-4053-2-50 · Cited by 6
Lucassen, W. A. M., Kuijs-Augustijn, M., Erkens, P. M. G., Geersing, G., Buller, H. R., & van Weert, H. C. P. M. (2013) · European Journal of General Practice · doi:10.3109/13814788.2013.780019 · Cited by 5
Prenatal markers of neonatal fat mass: A systematic review
Roelants, J. A., de Jonge, R. C. J., Steegers‐Theunissen, R. P. M., Reiss, I. K. M., Joosten, K. F. M., & Vermeulen, M. J. (2015) · Clinical Nutrition · doi:10.1016/j.clnu.2015.09.003 · Cited by 5
Diagnostic Accuracy of Epithelial Membrane Antigen for Malignant Effusions: A Meta-Analysis
Lin, W., Liu, X., & Cen, Y. (2016) · The International Journal of Biological Markers · doi:10.5301/jbm.5000181 · Cited by 5
Zhang, X., Zhou, J., Wu, H., Ma, H., & Jiang, Z. (2017) · Oncotarget · doi:10.18632/oncotarget.17914 · Cited by 5
Giraldo‐Cadavid, L. F., Burguete, J., Rueda, F., Galvis, A. M., Castaneda, N., Arbulú, M. R., Balaguera, J. I., Páez, N., & Fernández, S. (2017) · Dysphagia · doi:10.1007/s00455-017-9826-y · Cited by 6
Liu, Y., Ma, J., & Liu, Y. (2017) · Oncotarget · doi:10.18632/oncotarget.21444 · Cited by 5
Usunier, K., Hynes, M., Schuster, J. M., Suen, A. C.-J., Sadi, J., & Walton, D. M. (2017) · Physiotherapy Canada · doi:10.3138/ptc.2016-89.mt · Cited by 5
Diagnostic value of circulating microRNAs for liver cirrhosis: a meta-analysis
Guo, L., Li, W., Hu, L., Zhou, H., Zheng, L., Yu, L., & Liang, W. (2017) · Oncotarget · doi:10.18632/oncotarget.23332 · Cited by 5
Heazell, A. E. P., Hayes, D. J. L., Whitworth, M. K., Takwoingi, Y., Bayliss, S. E., & Davenport, C. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012245 · Cited by 5
Stock, S. J., Wotherspoon, L. M., Boyd, K., Morris, R. K., Dorling, J. S., Jackson, L., Chandiramani, M., David, A. L., Khalil, A. A., Shennan, A. H., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-020796 · Cited by 5
Screening for spinal muscular atrophy
Sampaio, H. A., Wilcken, B., & Farrar, M. A. (2018) · The Medical Journal of Australia · doi:10.5694/mja17.00772 · Cited by 6
Abraha, I., Montedori, A., Renzo, G. C. D., Angelozzi, P., Micheli, M., Carloni, D., Germani, A., Palmieri, G., Casali, M., Nenz, C. M. G., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-021322 · Cited by 5
Gasse, C., Paquette, K., Demers, S., Roberge, S., Bujold, E., & Boutin, A. (2018) · Systematic Reviews · doi:10.1186/s13643-018-0885-4 · Cited by 5
Kubo, T., Furuta, T., Sakuda, T., Ochi, M., & Adachi, N. (2018) · Medicine · doi:10.1097/md.0000000000013308 · Cited by 6
Surveillance of non-muscle invasive bladder cancer using fluorescence in situ hybridization
Lin, T., Jin, H., Gong, L., Yu, R., Sun, S., Yang, L., Zhang, P., Han, P., Cheng, J., Liu, L., et al. (2019) · Medicine · doi:10.1097/md.0000000000014573 · Cited by 5
Mortensen, K. M., Itenov, T. S., Hansen, M. B., Hvid, K., Lundstrøm, L. H., & Bestle, M. H. (2019) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13339 · Cited by 5
Sterbova, M., Pazourková, E., Santorova, S., Zednikova, I., Tesařová, P., & Korabečná, M. (2019) · Neoplasma · doi:10.4149/neo_2018_180907n679 · Cited by 5
Lugo‐Agudelo, L. H., Ortiz, S. D., Rangel, A., Ospina, A., & Sénior, J. M. (2019) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2018.10.015 · Cited by 10
Relapsed ovarian cancer - diagnosis using 18F-FDG PET/CT; 4.
Esteves, F. P., Amorim, B. J., Martello, M., Matushita, C. S., Gomes, G. D. V., Brito, A. E., & Bernardo, W. M. (2019) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.65.4.509 · Cited by 5
Cervical cancer - staging and restaging with 18F-FDG PET/CT
Brito, A. E., Matushita, C. S., Esteves, F. P., Gomes, G. D. V., Bernardo, W. M., & Amorim, B. J. (2019) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.65.4.568 · Cited by 5
Iftikhar, I. H., Greer, M., & Jaiteh, A. (2019) · Lung · doi:10.1007/s00408-019-00233-4 · Cited by 5
Health Care for Mitochondrial Disorders in Canada: A Survey of Physicians
Paik, K., Lines, M. A., Chakraborty, P. K., Khangura, S. D., Latocki, M., Al‐Hertani, W., Brunel‐Guitton, C., Khan, A., Penny, B., Greenberg, C. R., et al. (2019) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/cjn.2019.240 · Cited by 6
“, random or sequential patients suspected of a mitochondrial disease) and ensuring comparable follow-up.(22,23) Stratification by phenotype may be important as the value of particular diagnostic strategies may differ depending on clinical manifestations and patient characteristics.”
Choosing an Adequate Test to Determine Fitness for Air Travel in Obese Individuals
Rooney, D., Herkenrath, S. D., Priegnitz, C., Putzke, M., Treml, M., Wenzel, J., Aeschbach, D., & Randerath, W. J. (2019) · CHEST Journal · doi:10.1016/j.chest.2019.07.022 · Cited by 5
Impact of ultrasound diagnosis for chronic pelvic pain
Wang, X., Xu, J.-J., Yang, G., & Xin, T. (2019) · Medicine · doi:10.1097/md.0000000000017281 · Cited by 5
IP-10 for the diagnosis of tuberculosis in children
Zhang, W. (2019) · Medicine · doi:10.1097/md.0000000000015977 · Cited by 5
Wu, H. (2019) · International Journal of Ophthalmology · doi:10.18240/ijo.2019.12.14 · Cited by 6
Ultrasound fetal anthropometry to identify large-for-gestational-age: a meta-analysis
Goto, E. (2020) · Minerva Obstetrics and Gynecology · doi:10.23736/s0026-4784.19.04460-5 · Cited by 5
Association between interleukin gene polymorphisms and multiple myeloma susceptibility
Shahzad, M. N., Ijaz, I., Naqvi, S., Yan, C., Lin, F., Li, S., & Huang, C. (2020) · Molecular and Clinical Oncology · doi:10.3892/mco.2020.1979 · Cited by 5
Soumya, S., Whitehorn, A., Ooi, E. H., & Lockwood, C. S. (2020) · The JBI Database of Systematic Reviews and Implementation Reports · doi:10.11124/jbisrir-d-19-00225 · Cited by 5
Goh, Y. M., Antonowicz, S., Boshier, P. R., & Hanna, G. B. (2020) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2020/2930347 · Cited by 9
Ni, Q., Li, C., & Lin, H. (2020) · BioMed Research International · doi:10.1155/2020/3472615 · Cited by 5
Reporting guidelines for journal and conference abstracts
Cohen, J. F., Korevaar, D. A., Boutron, I., Gatsonis, C., Hopewell, S., McInnes, M. D. F., Moher, D., von Elm, E. B., & Bossuyt, P. M. (2020) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2020.04.012 · Cited by 5
Self-citationChen, Y., Chen, X., Wang, X., Liu, Z., Zhou, H., & Xu, S. (2020) · Clinical Epidemiology · doi:10.2147/clep.s262939 · Cited by 5
Ganancia de peso gestacional como predictor de macrosomía y bajo peso al nacer: revisión sistemática
Santos-Antonio, G., Alvis-Chirinos, K., Aguilar-Esenarro, L., Bautista-Olórtegui, W., Velarde-Delgado, P., & Aramburú, A. (2020) · Revista Peruana de Medicina Experimental y Salud Pública · doi:10.17843/rpmesp.2020.373.4919 · Cited by 8
Stasio, G. D., & Montanelli, M. (2020) · Journal of the American Podiatric Medical Association · doi:10.7547/19-040 · Cited by 5
Yu, G., Shen, Y., Xu, X., & Lin, L. (2021) · PLoS ONE · doi:10.1371/journal.pone.0250470 · Cited by 5
Lappharat, S., & Liabsuetrakul, T. (2020) · Medicine · doi:10.1097/md.0000000000023161 · Cited by 8
Cheng, T., Liu, B., Han, T.-Y., Pan, P., Liu, J.-Z., & Yu, H. (2021) · Medicine · doi:10.1097/md.0000000000024658 · Cited by 6
Diagnostic value of lung ultrasound in COVID-19: systematic review and meta-analysis
Vetsheva, N. N., Reshetnikov, R. V., Leonov, D. V., Kulberg, N. S., & Mokienko, O. A. (2020) · Digital Diagnostics · doi:10.17816/dd46834 · Cited by 5
Wu, Y., Zheng, J., Sun, Y. T., Wang, X., Zhao, H., Qiu, F., Zhang, S., Jiang, X., & Yu, X. (2021) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2021.105762 · Cited by 5
Izsák, V. D., Soós, A., Szakács, Z., Hegyi, P., Juhász, M. F., Varannai, O., Martonosi, Á. R., Földi, M., Kozma, A., Vajda, Z., et al. (2021) · Biomolecules · doi:10.3390/biom11040520 · Cited by 6
Completeness of reporting for systematic reviews of point-of-care ultrasound: a meta-research study
Prager, R. T., Pratte, M., Guy, A., Bala, S., Bachar, R., Kim, D., Millington, S. J., Salameh, J., McGrath, T. A., & McInnes, M. D. F. (2021) · BMJ Evidence-Based Medicine · doi:10.1136/bmjebm-2020-111652 · Cited by 7
Consenso de tromboprofilaxis en cirugía ginecológica
Ginecológica, G. D. D. C. D. T. E. C., & y Ginecología, F. C. D. O. (2021) · Revista Colombiana de Obstetricia y Ginecología · doi:10.18597/rcog.3666 · Cited by 5
“Se utilizó la herramienta AMSTAR-2 (Ameasurement Tool to Assess Systematic Reviews) (12) como ins-trumento de evaluación crítica para las revisiones sistemáticas y cuando se trató de estudios prima-rios, los ensayos clínicos controlados fueron eva-luados aplicando el instrumento de riesgo de sesgos versión 2.0 sugerid…”
InfluentialDoes radiological conjugate eye deviation sign play a role in acute stroke imaging? A meta-analysis
Li, M., Liang, W., Yue, P., Jiang, X. G., Zhao, Z., Zhao, B., Xu, Z., & Mang, J. (2021) · Journal of Neurology · doi:10.1007/s00415-021-10540-7 · Cited by 5
Diagnostic Accuracy of 10/66 Dementia Protocol in Fijian-Indian Elders Living in New Zealand
Martínez-Ruiz, A., Krishnamurthi, R., Dahiya, E. S., Rai-Bala, R., Naicker, S., Yates, S., Rodriguez, C. R., Cheung, G., Dudley, M. D., Kerse, N. M., et al. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18094870 · Cited by 6
Meyer, H., Wienke, A., & Surov, A. (2021) · Urologic Oncology Seminars and Original Investigations · doi:10.1016/j.urolonc.2021.03.015 · Cited by 9
Liu, Y.-L., Xie, T.-A., Lin, G.-L., Deng, W., Lin, Q.-R., Pan, Z.-Y., Fan, S.-J., Li, Z.-X., Ouyang, S., Zhu, G.-D., et al. (2021) · Japanese Journal of Infectious Diseases · doi:10.7883/yoken.jjid.2020.987 · Cited by 5
Wang, M., Gao, S., Zhang, Y., & Zhang, M. (2021) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-021-05239-4 · Cited by 6
Wang, J., Zhao, S., Xu, D. R., Estill, J. A. M., Lv, M., Zhao, S., Zhang, M., Cai, Y., Liao, J., Lu, Y., et al. (2021) · Annals of Palliative Medicine · doi:10.21037/apm-21-712 · Cited by 5
Yip, K. C. J., Li, Y.-L., Chen, S., Ho, C. L., & Wartolowska, K. A. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00453-w · Cited by 5
Validation non-English version of modified checklist for autism in toddlers-revised with follow-up
Nukeshtayeva, K., Lubchenko, M., Omarkulov, B. K., & Delellis, N. O. (2021) · Journal of Clinical Medicine of Kazakhstan · doi:10.23950/jcmk/11041 · Cited by 5
Guo, H., Wang, Y., Wang, Z., Wang, Z., & Xue, S. (2021) · Open Medicine · doi:10.1515/med-2021-0347 · Cited by 6
Wang, J., Han, Y., Lin, L., Zhang, L., Li, J., Gao, H., & Fu, P. (2021) · Translational Andrology and Urology · doi:10.21037/tau-21-912 · Cited by 5
Nuijts, M. A., Imhof, S. M., Veldhuis, N., Dekkers, C., Meeteren, A. Y. N. S., & Stegeman, I. (2021) · PLoS ONE · doi:10.1371/journal.pone.0261631 · Cited by 5
dos Santos, L. S., Cerqueira, S. R. P. S., & Gomes, C. M. (2021) · Frontiers in Microbiology · doi:10.3389/fmicb.2021.758222 · Cited by 5
Wang, X., Zheng, X., Zhu, J., Li, Z., & Wei, T. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.757766 · Cited by 5
Validity of the four‐square step test in persons with haemophilia
Taylor, S., Pemberton, S., & Barker, K. L. (2022) · Haemophilia · doi:10.1111/hae.14482 · Cited by 5
Li, Y., & Li, S. (2022) · Clinical and Experimental Obstetrics & Gynecology · doi:10.31083/j.ceog4901015 · Cited by 5
Viviers, M., Edwards, L., Asir, M., Hibberd, J., Rowe, R., Phillips, S., Thomas, V., Keesing, M., Sugar, A., & Allen, J. (2022) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12695 · Cited by 5
Chen, H., Katakura, S., Horita, N., Namkoong, H., Kato, I., Hara, Y., Kobayashi, N., Fujii, S., & Kaneko, T. (2022) · Therapeutic Advances in Medical Oncology · doi:10.1177/17588359211065152 · Cited by 6
Wang, S., Hu, J., Sui, C., He, G., Qu, Z., Chen, X., Wang, Y., Guo, D., & Liu, X. (2022) · Microbial Pathogenesis · doi:10.1016/j.micpath.2022.105498 · Cited by 6
Singh, A., & Dwivedi, A. (2022) · Biomarkers · doi:10.1080/1354750x.2022.2064551 · Cited by 5
Meta-analysis of the robustness of COVID-19 diagnostic kit performance during the early pandemic
Shanmugam, C., Behring, M. P., Luthra, V., Leal, S. M., Diffalha, S. A., Varambally, S., Netto, G. J., & Manne, U. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-053912 · Cited by 5
Raji, S., Sahranavard, M., Mottaghi, M., & Sahebkar, A. (2022) · Cancer Cell International · doi:10.1186/s12935-022-02584-0 · Cited by 5
Wen, S. W. C., Wen, J., Hansen, T. F., Jakobsen, A. K. M., & Hilberg, O. (2022) · Cancers · doi:10.3390/cancers14092254 · Cited by 6
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.