QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 10,501–10,600 of 14,770
Yang, C., Wu, M., Zhang, J., Qian, H., Fu, X., Yang, J., Luo, Y., Qin, Z., & Shi, T. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1425078 · Cited by 4
Rangappa, A., Arul, B., Somasundaram, J., & Natanasabapathy, V. (2024) · Endodontology · doi:10.4103/endo.endo_5_24 · Cited by 3
How reliable is artificial intelligence in the diagnosis of cholesteatoma on CT images?
Avallone, E., Luca, P. D., Timm, M. E., Agnese, S., Viola, P., Ralli, M., Chiarella, G., Ricciardiello, F., Salzano, F. A., & Scarpa, A. (2024) · American Journal of Otolaryngology · doi:10.1016/j.amjoto.2024.104519 · Cited by 3
Bellia, C., Sardina, D. S., Scazzone, C., Lio, D., Scola, L., & Uasuf, C. G. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252312925 · Cited by 3
Mohammed, A. A., Mahon, E., Moore, N., Sweetman, L., Maher, M. M., O'Regan, P. W., England, A., & McEntee, M. F. (2024) · European Journal of Pediatrics · doi:10.1007/s00431-024-05894-9 · Cited by 3
“The validity of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Stud-ies-2 tool (QUADAS-2) [46].”
Etholm, L., Ivanović, J., Larsen, V. S., Sneve, M. H., Lossius, M. I., & Alfstad, K. Å. (2024) · Epileptic Disorders · doi:10.1002/epd2.20317 · Cited by 3
Kao, T., Chen, J., Liu, J.-H., Tseng, W., Hsieh, C.-C., Wu, V., Lin, Y., & Chen, Z. (2024) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188241303429 · Cited by 3
Long, Y., Zhao, R., & Du, X. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2024.1428929 · Cited by 3
Prenatal ultrasound for the diagnosis of the cerebellar abnormalities: a meta-analysis
Sun, Z. K., Chen, Y., & Su, Q. (2025) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2025.2453997 · Cited by 3
“the included studies underwent a quality assessment using the Quality Assessment tool for Diagnostic Accuracy Studies (QUADAS-2) scale [24], implemented with Robvis [25]. this evaluation involved categorizing each study as having either a low, high, or “some concerns” risk within each domain,…”
Khan, S. J., Qayyum, K., Qadeer, A., Khalid, M., Anthony, S., khan, W., Ghulam, M., Jamil, Z., & Anthony, N. (2025) · Cureus · doi:10.7759/cureus.78683 · Cited by 7
“Moreover, inconsistencies in the reported diagnostic performance of AI models raise concerns about their real-world applicability and clinical decision-making impact [7].”
Accuracy of diagnostic tests for feline sporotrichosis: A systematic review and meta-analysis
Domingos, E. L., Souza, D. A., Alves, F. M. S., Gorski, D., Tonin, F. S., Ferreira, L. M., & Pontarolo, R. (2025) · Acta Tropica · doi:10.1016/j.actatropica.2025.107549 · Cited by 3
Кримовський, К., Мілещенко, А., & Бричко, Т. (2024) · Archive of Ophthalmology and Maxillofacial Surgery of Ukraine · doi:10.22141/aomfs.1.1.2024.9 · Cited by 3
Salvatore, S. D., Brigato, P., Palombi, D., Oggiano, L., Sessa, S., Longo, U. G., & Costici, P. F. (2025) · Applied Sciences · doi:10.3390/app15041829 · Cited by 3
Frain, J. (2025) · Wiley eBooks · doi:10.1002/9781394219346.ch7 · Cited by 4
Shi, M., Wei, Y., Huang, H., Guo, R., & Luo, F. (2025) · Microbial Pathogenesis · doi:10.1016/j.micpath.2025.107417 · Cited by 5
Smith, G., Teng, W. H., Riley, N. D., Little, C. D. J., Sellon, E., Thurley, N., Dias, J., & Dean, B. J. F. (2025) · Bone & Joint Open · doi:10.1302/2633-1462.63.bjo-2024-0211.r1 · Cited by 3
Diagnostic accuracy of MRI and US for peroneal tendon tears: a systematic review and meta-analysis
Ghandour, S., Mercer, R. W., Strahan, J. A., Bejarano‐Pineda, L., & Stewart, Z. E. (2025) · European Radiology · doi:10.1007/s00330-025-11472-w · Cited by 3
“Similarly, a high concern for applicability was considered in a study if one or more of the related three QUADAS-2 domains was judged to be “ high ” or “ unclear ” [7].”
Reagan, E. D., Mrema, L. E., Ntinginya, N. E., Biraro, I. A., van Crevel, R., & Critchley, J. (2025) · Tropical Medicine & International Health · doi:10.1111/tmi.14103 · Cited by 5
“To assess the risk of bias of included studies, we applied the QUADAS-2 tool [22]; conducted by two researchers independently (EDR, ELM) with disagreements resolved by con-sultation with a third researcher (JAC) and results plotted using the Robvis tool [23].”
The French way of HTA: Between scientific rigor, independence and transparency
Baba, J., Guerrier, N., Guzina, I., Hernando, V., Ressencourt, V., Spasojevic, I., Thorrington, D., & Masia, C. (2025) · La Presse Médicale · doi:10.1016/j.lpm.2025.104281 · Cited by 3
Moreira, G. C., Ribeiro, C. S. D. C., Verner, F. S., & Lemos, C. A. A. (2025) · Dentomaxillofacial Radiology · doi:10.1093/dmfr/twaf027 · Cited by 4
Hu, S., Tian, Y., & He, M. (2025) · Frontiers in Pediatrics · doi:10.3389/fped.2025.1472382 · Cited by 3
Singh, S., Mahto, K., Kumar, A., Kumar, P., Kumar, S., & Prasad, M. K. (2025) · Infection and Chemotherapy · doi:10.3947/ic.2024.0139 · Cited by 3
“Each domain was further graded as low, high, and unclear risk [18].”
Li, L., Zhang, B., Yang, Y., Zhang, S., An, R., & Wan, Q. (2025) · Aging & Mental Health · doi:10.1080/13607863.2025.2495794 · Cited by 4
“Figure 5 presents the result of the QUADAS-2 (Whiting et al., 2011) quality assessment for all studies included.”
InfluentialLi, X., Han, B., Wu, T., Chen, T., Wang, G., & Zhang, H. (2025) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2025.110445 · Cited by 3
“We used the QUADAS-2 methodological quality graph and summary to assess the quality of eligible studies [13].”
Sönmez, G., & Ünlütürk, U. (2025) · Endocrine · doi:10.1007/s12020-025-04266-z · Cited by 6
“This tool evaluates studies based on four criteria: “ patient selection, ” “ index test, ” “ reference standard, ” and “ fl ow and timing ” [6].”
de Alencar, J. N., Rassi, F. M., Ríos, R., Scheffer, M. K., & de Carvalho, G. D. (2025) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240663 · Cited by 3
“…from previous studies into pooled data and setting a precedent for standardizing definitions in future research to prevent confusion and incorrect conclusions, 13 such as the notion that “the loss of a pre-excitation lacks the power to reduce the probability of a high-risk accessory pathway.””
Accuracy of Falls Screening Tools in Adult Patients With Cancer: A Systematic Review
Nielsen, K., Foley, M., Croarkin, E., Runde, P., Prinster, S., & Gilchrist, L. S. (2025) · Physical Therapy · doi:10.1093/ptj/pzaf068 · Cited by 3
Evaluation of Pulp Vitality Using Pulse Oximetry: A Systematic Review and Meta-analysis
Sabharwal, R. J., Dhull, K. S., Dutta, B., Devraj, I. M., Surana, P., Misra, A., & Gupta, A. (2025) · International Journal of Clinical Pediatric Dentistry · doi:10.5005/jp-journals-10005-3107 · Cited by 3
Han, Z., Zhao, Y., Tang, Y., Yi, X., Li, J., Li, X., Liao, D., Zhu, Y., & Ai, J. (2025) · World Journal of Urology · doi:10.1007/s00345-025-05728-9 · Cited by 3
“Two researchers independently evaluated the quality of included articles using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [22].”
Outcome measures of instrumented gait analysis in hereditary spastic paraplegia: a systematic review
Koch, V., Ibrahim, A., Winkler, J., Eskofier, B. M., Regensburger, M., & Gaßner, H. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01646-4 · Cited by 3
“The quality of the included studies was evaluated using the QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies) [21].”
Sabisz, A., Brzeska, B., Szurowska, E., & Szarmach, A. (2025) · Diagnostics · doi:10.3390/diagnostics15131578 · Cited by 5
“The quality assessment of selected studies was performed based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [17].”
Wang, D., & Sun, L. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.05.056 · Cited by 3
Dong, J., Hu, X., Li, L., Jing, F.-Y., Chen, J., & Chen, J. (2025) · Discover Oncology · doi:10.1007/s12672-025-03008-x · Cited by 3
“The methodological quality of each study was assessed by two evaluators using the Quality Assessment of Diagnostic Accuracy Studies-2 tool, which covers patient selection, index test, reference standard, bias risk, and applicability [20].”
Diagnosis of Systemic Rheumatic Disease Using the Connective Tissue Disease Screen
Kapuczinski, A., Parisis, D., Kassab, N., Smet, J., & Soyfoo, M. S. (2025) · Antibodies · doi:10.3390/antib14030056 · Cited by 3
Baszak-Radomańska, E., Wańczyk-Baszak, J., & Paszkowski, T. (2025) · Women s Health · doi:10.1177/17455057251338410 · Cited by 5
Prabhu, M. S., Kolekar, S. V., & Nandakumar, G. (2025) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0000000000000468 · Cited by 4
Houshi, S., Khodakarami, Z., Shaygannejad, A., Khosravi, F., & Shaygannejad, V. (2025) · Neurological Research · doi:10.1080/01616412.2025.2532038 · Cited by 4
“Two reviewers (SH and ZK) independently evaluated each study using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) criteria [26] to ensure a thorough evaluation.”
Whole-body imaging for distant staging of bone chondrosarcoma: a systematic review
Dejua, D., Flammineis, E. D., Zecca, F., Saba, L., Davies, M., & Botchu, R. (2025) · La radiologia medica · doi:10.1007/s11547-025-02054-3 · Cited by 3
“The quality of observational studies was assessed using the QUADAS-2 tool [24], while the quality of evidence summaries was assessed using the AMSTAR 2 tool [25].”
Development and application of meta-analysis in environmental health research
Li, Q., Liang, X., Yang, R., Yin, N., & Faiola, F. (2025) · Critical Reviews in Toxicology · doi:10.1080/10408444.2025.2530972 · Cited by 4
“QUADAS-2 (Whiting et al. 2011), qualitatively evaluates bias risk in diagnostic studies, while JBI checklists use yes/no/unclear responses with rationales for diverse designs (Zeng et al. 2015).”
Yousif, B. A. H., Abdallah, A. B. A. A., Abdelhalim, A. A. I., Mohammedosman, M. E., Sadaka, S. I. H., & Alzobeir, S. A. A. (2025) · Cureus · doi:10.7759/cureus.89093 · Cited by 3
“The methodological quality and risk of bias of the included studies were assessed using the QUADAS-2 tool [13], which is well-suited for evaluating diagnostic accuracy studies and adaptable for AI-based clinical research.”
Yu, L., Liu, D., Payne, J. M., Zhang, J., Moreira, J., Mukhopadhyay, E. S., Novotney, A., Chown, M.-M., Killam, J., & Hou, Y. (2025) · Neuropsychology Review · doi:10.1007/s11065-025-09673-7 · Cited by 6
“Guided by the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-II) (Whiting et al., 2011), this study considered several methodological factors that may bias estimates of group differences in visuospatial and visuo-motor abilities: participant selection, index test, reference standard, and…”
Xie, J., Ye, L., Yang, J., Zhong, Y., Xu, P., Gao, B., Wang, N., Ye, X., Tong, G., & Huang, J. (2025) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.70054 · Cited by 4
Cox, J., Bhatti, A., & Atapour–Abarghouei, A. (2025) · European Journal of Radiology Artificial Intelligence · doi:10.1016/j.ejrai.2025.100040 · Cited by 3
Gatta, E., Maltese, V., Dondi, F., Bellini, P., Ugoccioni, M., Silvestrini, I., Ceraso, A., Vita, A., Rotondi, M., Bertagna, F., et al. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1580854 · Cited by 3
Oo, M. M., Rudd, M., Shukalek, C. B., Kishibe, T., Hull, M., & Tan, D. H. S. (2025) · EClinicalMedicine · doi:10.1016/j.eclinm.2025.103487 · Cited by 6
“27 Risk of bias assessments were conducted for descriptive purposes only and did not influence the decision to include or exclude studies from the review.”
Liquid biopsy biomarkers in cervical cancer: A systematic review and meta-analysis
Njangiru, I. K., Tayeb, B. A., Ali, H. A., & Kamil, R. M. (2025) · The Journal of Liquid Biopsy · doi:10.1016/j.jlb.2025.100328 · Cited by 3
“Each of the included studies underwent independent assessment by two reviewers, BAT and IKN, via the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [17].”
Kéri, S. (2025) · Life · doi:10.3390/life15101599 · Cited by 5
“These studies and subsequent systematic reviews and meta-analyses should take into account standards for the quality assessments of diagnostic accuracy studies [65].”
Buxbom, C. T., Braithwaite, A., Hess, S., Hermansen, L. L., & Kusk, M. W. (2025) · European Journal of Radiology Open · doi:10.1016/j.ejro.2025.100686 · Cited by 3
“Risk of bias was assessed with QUADAS-2 [18].”
Antkowiak, Ł., Antkowiak, M., Kasperczuk, A., Kaspera, W., & Mandera, M. (2025) · Neurosurgical Review · doi:10.1007/s10143-025-03926-y · Cited by 3
Kim, B. J., Kang, S., Nam, S. Y., Bang, C. S., Min, B., Kim, S. E., Kim, S. Y., Lim, H. C., Tae, C. H., Lee, M. W., et al. (2026) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.70225 · Cited by 5
Rofananda, I. F., Pratiwi, A. D., Putra, E. S. J., Azhari, S. R. B., & setiawati, R. (2025) · Malaysian Journal of Medicine and Health Sciences · doi:10.47836/mjmhs.21.2.26 · Cited by 3
Haba, K. S., Kreuter, P., Qian, X., Agócs, G., Bányai, D., Rózsa, N. K., Hegyi, P., Hermann, P. M., Jurado, C. A., Haluszka, D., et al. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15051829 · Cited by 4
“Two reviewers independently analyzed the articles for risk of bias using the QUADAS-2 tool [15].”
Thirumala, P. D., Balzer, J. R., Szelényi, A., Seidel, K., Husain, A. M., Bossuyt, P. M., Drost, G., Absalom, A. R., Binzer, S., Fehlings, M. G., et al. (2026) · Clinical Neurophysiology · doi:10.1016/j.clinph.2026.2112364 · Cited by 3
Self-citationUnderstanding Bias in Diagnostic Research
Pines, J. M., Carpenter, C. R., Raja, A. S., & Schuur, J. D. (2012) · Wiley eBooks · doi:10.1002/9781118482117.ch6 · Cited by 4
Chappell, F. M., Andras, A., Welch, K., Nisio, M. D., Robertson, L., Stewart, M. C. W., & Crawford, F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012356 · Cited by 3
Heirene, R. M., Roderique‐Davies, G., Roberts, P., & John, B. (2016) · Cogent Psychology · doi:10.1080/23311908.2016.1229841 · Cited by 3
Schwendicke, F., Elhennawy, K., Shahawy, O. I. E., Maher, R., Gimenez, T., Mendes, F. M., & Willis, B. H. (2018) · BMC Oral Health · doi:10.1186/s12903-018-0561-z · Cited by 3
Manterola, C., Cartes‐Velásquez, R., Burgos, M. E., Sanhueza, A., & Otzen, T. (2018) · International Journal of Morphology · doi:10.4067/s0717-95022018000200743 · Cited by 3
Kritisch beoordelen van een artikel over primair onderzoek
Offringa, M., Assendelft, W. J., Scholten, R. J. P. M., Leeflang, M., Bossuyt, P. M., Groenwold, R. H. H., Reitsma, J. B., de Laar, F. A. V., van Puijenbroek, E., Broeders, M. J. M., et al. (2018) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-1978-7_4 · Cited by 3
Self-citationRETRACTED: Potential biomarker for breast cancer screening: A systematic review and meta-analysis
Wang, Y., Zhang, G., Hao, X., Ma, Y., Ma, M., Yan, X., Jiang, X., Bie, F., & Yuan, N. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2018.09.030 · Cited by 3
RetractedDavis, C., Immormino, J., Higgins, B., Clark, K., Engebose, S., Garcia, A. N., & Cook, C. E. (2018) · Shoulder & Elbow · doi:10.1177/1758573218811656 · Cited by 3
Mander, G., Dobeli, K., Steffensen, C., & Munn, Z. (2018) · The JBI Database of Systematic Reviews and Implementation Reports · doi:10.11124/jbisrir-2017-003883 · Cited by 3
Díaz, J. J. S., Tejeda, M., Yate, J. A., Fernández, J. J. D., & González, E. (2017) · Archivos de cardiología de México · doi:10.1016/j.acmx.2017.03.002 · Cited by 3
About the diagnostic value of BAP-1 antibody in malignant pleural mesothelioma: a meta-analysis
Mlika, M., Zorgati, M. M., Khelil, M. B., & Mezni, F. E. (2019) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2019.1574814 · Cited by 3
Shamloo, A. S., Dinov, B., Bertagnolli, L., Sommer, P., Husser-Bollmann, D., Bollmann, A., Hindricks, G., & Arya, A. (2019) · International Heart Journal · doi:10.1536/ihj.18-391 · Cited by 3
Monitorização não invasiva da hemoglobina em ensaios clínicos: uma revisão sistemática e metanálise
Zortéa, T., Wizbicki, D. P. D. S., Madeira, K., Ambrósio, P. G., de Souza, R. O. B., & Durães, E. S. M. (2020) · Brazilian Journal of Anesthesiology · doi:10.1016/j.bjan.2019.05.006 · Cited by 3
Othman, R., Jayakaran, P., Tumilty, S., Swain, N., & Mani, R. (2019) · Physical Therapy Reviews · doi:10.1080/10833196.2019.1648715 · Cited by 4
The role of systematic review and meta‐analysis in modern cytopathology
Trimboli, P., Treglia, G., Giovanella, L., & Bongiovanni, M. (2019) · Cancer Cytopathology · doi:10.1002/cncy.22173 · Cited by 3
Systematic review of the accuracy of plasma preparation tubes for HIV viral load testing
Luo, R. F., Markby, J. L., Sacks, J. A., & Vojnov, L. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225393 · Cited by 3
Validity and reliability of three-dimensional imaging to measure limb volume: A systematic review
Kremer, R. L., Wolfe, M. E., Brueckner, N. J., Viola, M. C., & Fisher, M. I. (2019) · Physical Therapy Reviews · doi:10.1080/10833196.2019.1698160 · Cited by 3
Yu, Y., Zhao, Y., Wang, C., Zhang, X., & Liu, X. (2020) · Revista Española de Enfermedades Digestivas · doi:10.17235/reed.2020.5450/2018 · Cited by 3
“Quality assessment We used the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool to assess the qualities of each incorporated study (15).”
Tecnologias para o Diagnóstico da Radiodermite: uma Revisão Sistemática
Shiguihara, D. S. I., Oselame, G. B., & Neves, E. B. (2020) · Archivos de Medicina (Manizales) · doi:10.30554/archmed.20.2.3706 · Cited by 3
Wu, F., Huang, Y., Huang, X., Fang, S., Huang, X., Huang, X., Zhang, Z., & Shao, Z. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.00762 · Cited by 3
The Noninvasive Fetal Electrocardiogram During Labor: A Review of the Literature
Lempersz, C., Noben, L., de Vries, B., van Laar, J. O. E. H., Westerhuis, M. E. M. H., & Oei, S. G. (2020) · Obstetrical & Gynecological Survey · doi:10.1097/ogx.0000000000000798 · Cited by 3
Diagnostic performance of circulating MicroRNAs in acute ischemic stroke
Cao, W., Zhang, T., Wang, L., Fu, J., & Jin, H. (2020) · Medicine · doi:10.1097/md.0000000000022353 · Cited by 3
Toe-brachial index and toe systolic blood pressure for the diagnosis of peripheral arterial disease
Tehan, P. E., Mills, J. L., Sebastian, M. G., Oldmeadow, C. J., & Chuter, V. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013783 · Cited by 3
Peng, L., Li, J., Meng, C., Li, J., Tang, D., Guan, F., Xu, P., Wei, T., & Li, Y. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.570127 · Cited by 3
Komolafe, T. E., Agbo, J., Olaniyi, E. O., Komolafe, K., & Yang, X. (2020) · Diagnostics · doi:10.3390/diagnostics10121023 · Cited by 3
Foley, K., Jeffries, J., Hannon, C., Coles, B., Bradley, K. M., & Smyth, E. C. (2020) · International Journal of Clinical Practice · doi:10.1111/ijcp.13906 · Cited by 3
Research Note: Diagnostic test accuracy studies
Verhagen, A. P., & Hancock, M. J. (2020) · Journal of physiotherapy · doi:10.1016/j.jphys.2020.12.004 · Cited by 3
Urinary markers in the surveillance of non-muscle invasive bladder cancer. A literature review
Castañeda, F. Á., Raventos, C. X., & Moróte, J. (2019) · Actas Urológicas Españolas (English Edition) · doi:10.1016/j.acuroe.2019.03.014 · Cited by 3
Quartuccio, N., & Rubello, D. (2021) · Journal of Cancer Metastasis and Treatment · doi:10.20517/2394-4722.2020.118 · Cited by 3
Critical Appraisal of Studies of Diagnostic Test Accuracy
Newman, T. B., & Kohn, M. A. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108500111.005 · Cited by 3
Shaffer, S. M., Kavchak, A. J. E., Burr, M. R., Einhorn, L., & Naze, G. S. (2021) · Physical Therapy Reviews · doi:10.1080/10833196.2021.1914955 · Cited by 3
Cytology for the diagnosis of endometrial cancer in symptomatic women
O’Flynn, H., Jones, E. R., Njoku, K., Rana, D. N., Shelton, D., Narine, N., Ramchander, N. C., Patel, V., Walter, F. M., Walsh, T., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014560 · Cited by 3
Chen, H., Luo, Y., Li, C., Zhan, W., Tan, Q., Xie, C., Sharma, A., Sharma, H. S., & Zhang, Z. (2021) · Progress in brain research · doi:10.1016/bs.pbr.2021.06.011 · Cited by 3
Ojiambo, K. O., Kisangala, E., Nakalembe, L., Namisango, E., Nalugoda, F. K., Ndagire, R., Wangi, R. N., Kawala, B. A., Katairo, T., Okullo, A. E., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-050296 · Cited by 4
Chua, T. H., & Chuah, K. L. (2021) · Acta Cytologica · doi:10.1159/000519380 · Cited by 4
Hashimoto, H., Yamamoto, S., Nakagawa, H., Suido, Y., Sato, S., Tabata, E., Okamori, S., Yoshida, T., Andō, K., Yoshitake, S., et al. (2021) · Respiration · doi:10.1159/000519675 · Cited by 3
Diagnostic value of microRNA-148/152 family in non-small-cell lung cancer (NSCLC)
Cheng, L., Li, Q., Tan, B., Ma, D., & Du, G. (2021) · Medicine · doi:10.1097/md.0000000000028061 · Cited by 3
Sun, M.-T., Gu, M.-M., Zhang, J.-Y., Yu, Q.-F., Lamberton, P. H. L., & Lu, D. (2022) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0010136 · Cited by 3
Zapf, A. (2018) · Springer eBooks · doi:10.1007/978-3-319-78966-8_11 · Cited by 3
Ovenden, C. D., Hiwase, A. D., Gyi, A.-A., Abou‐Hamden, A., & Kleinig, T. J. (2022) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2022.106379 · Cited by 3
Deb, A. A., Agag, A. A., Naushad, N., Rajbabu, K., & Serag, H. A. (2022) · Current Urology · doi:10.1097/cu9.0000000000000089 · Cited by 3
Diagnostic significance of long non-coding RNAs expression in tuberculosis patients
Zhong, X., Guo, Q., Zhao, J., Li, Y., Li, X., Ren, M., & Shu, M. (2022) · Medicine · doi:10.1097/md.0000000000028879 · Cited by 3
Choi, N., Jang, S., Yoo, K. H., Rhee, C. K., & Kim, Y. (2022) · Journal of Korean Medical Science · doi:10.3346/jkms.2022.37.e117 · Cited by 3
Ghoneim, M. M. R., Eid, R., Hamdy, N., Shokry, D., Salem, M. A., Elmorsy, A., & Elmokadem, A. H. (2022) · Polish Journal of Radiology · doi:10.5114/pjr.2022.114505 · Cited by 3
Sounderajah, V., Normahani, P., Aggarwal, R., Jayakumar, S., Markar, S. R., Ashrafian, H., & Darzi, A. W. (2022) · Springer eBooks · doi:10.1007/978-3-030-64573-1_34 · Cited by 3
Zhu, C., Feng, Z., Hong, F., Sun, H., Wang, Z., Zhao, Z. Z., & Zhang, F. (2022) · Pathology - Research and Practice · doi:10.1016/j.prp.2022.153871 · Cited by 3
Systematic Reviews of Diagnostic Test Accuracy
Pammi, M., & Takwoingi, Y. (2021) · Springer eBooks · doi:10.1007/978-3-030-71921-0_15 · Cited by 3
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.