QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 10,901–11,000 of 14,770
Pourakbar, N., Kiani, I., Toutounchian, S., Razavi, F., Daneshrad, S., Bahrami, O., & Lomer, N. B. (2026) · European Journal of Radiology Artificial Intelligence · doi:10.1016/j.ejrai.2026.100072 · Cited by 2
Petrosian, D., Giedraitienė, N., Kizlaitienė, R., Jatuzis, D., Kaubrys, G., & Vaišvilas, M. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2025.1579206 · Cited by 2
Patabendige, S., Falster, C., Langkilde, H. Z., Harders, S. W., Bendstrup, E. M., Durheim, M. T., & Davidsen, J. R. (2026) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-2785-1857 · Cited by 2
Vatteroni, G., Pötsch, N., Clauser, P., & Baltzer, P. (2026) · European Radiology · doi:10.1007/s00330-025-12291-9 · Cited by 2
“Two independent readers (G.V., P.A.T.B.) selected eligible studies and extracted the data in a prede fi ned Excel spreadsheet, assessed risk of bias and applicability concerns according to Quality Assessment of Diagnostic Accuracy Studies (QUADAS) – 2 [12].”
Cessa, R., Ghiani, A., Cenk, E., & Bertamini, M. (2026) · Schizophrenia Research · doi:10.1016/j.schres.2026.01.004 · Cited by 2
Bruinsma, J. D., Tharakan, N., Temperley, H. C., Curtain, B. M. M., Chau, M., & Bangash, H. K. (2026) · World Journal of Urology · doi:10.1007/s00345-026-06191-w · Cited by 5
“Quality assessment was performed according the Quality Assessment of Diagnostic Accuracy Studies 2 (QUA-DAS-2) and Radiomics Quality Score (RQS) [32, 33].”
Storozhenko, T. Y., Collison, D. G., Johnson, N. P., Sakai, K., Mizukami, T., Shinke, T., Matsuo, H., Munhoz, D., Buytaert, D., Ando, H., et al. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.124.040916 · Cited by 2
Diagnostic Performance of Artificial Intelligence in Detecting COVID-19 Pneumonia on Chest Imaging
Chapman, S. R., Willner, L., Abouafech, A., Roberti, C., & Willner, C. (2026) · Cureus · doi:10.7759/cureus.101775 · Cited by 2
A systematic review of artificial intelligence models in ocular tumour diagnosis
Sachdeva, K. S., Butt, F. R., Mihalache, A., Nassrallah, G. B., Muni, R. H., & Popovic, M. M. (2026) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2025.12.020 · Cited by 2
Remote sensing-based approaches for automatic vineyard area identification: a systematic review
Costa, D. S., Barriguinha, A., Areosa, I., Caetano, M. R., Teixeira, I., & Vanneschi, L. (2026) · Smart Agricultural Technology · doi:10.1016/j.atech.2026.101812 · Cited by 2
Estebanez‐Pérez, M., Estebanez, P. P., Viñolo-Gil, M. J., Martín‐Valero, R., & Pastora‐Bernal, J. (2026) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2025.12.030 · Cited by 2
Simadibrata, D. M., Koo, T. H., Murlidhar, M., Lamichhane, R., Rampengan, D. D. C. H., Danpanichkul, P., & Wong, R. C. K. (2026) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.70224 · Cited by 3
“The quality of included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [16].”
Fernández-Aedo, I., Ballesteros-Peña, S., Tobar-Cabrera, S., la Hoz, G. V.-D., & Fernandez-Alonso, J. (2026) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2026.01.030 · Cited by 2
Woima, R., Chiu, D. S., Khalil, E. A., El‐Halabi, S., Neilson, A., Bernard, L., McAlpine, J. N., & Talhouk, A. (2026) · Diagnostics · doi:10.3390/diagnostics16030378 · Cited by 3
“Risk of Bias: Two reviewers independently assessed study quality by adapting the QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies) [25] to include items on the definition and application of the PCT. Full criteria are available in Supplementary File S2.”
Hajikarimloo, B., Mohammadzadeh, I., Tos, S. M., Mortezaei, A., & Habibi, M. A. (2026) · Acta Neurochirurgica · doi:10.1007/s00701-026-06775-w · Cited by 2
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was used to assess the risk of bias (RoB) and applicability concerns across four domains: patient selection, index test, reference standard, and flow and timing [41].”
Greene, A., Young, R., Rainey, C., Greene, C., Gavin, A., McLaughlin, L., England, A., & McEntee, P. M. (2026) · Radiography · doi:10.1016/j.radi.2026.103332 · Cited by 2
Lim, K. S. A., Tng, W. X. A., Theng, W. D. B., Lee, B. T. K., Chin, C. F., Li, K. Z., & Moss, H. E. (2026) · Frontiers in Ophthalmology · doi:10.3389/fopht.2025.1691582 · Cited by 3
Turpo-Peqqueña, A. G., Santos-Vargas, S. A., Chipa, H. L., Lamas, F. M., Espinoza-Laura, G. A., Basurco, C. S. N., Medina-Neira, D. N., Benites-Bustamante, V. A., Osorio-Pacheco, R. R., Turpo-Peqqueña, J. R., et al. (2026) · Acta Neurochirurgica · doi:10.1007/s00701-026-06779-6 · Cited by 2
“The methodological quality and risk of bias of the included studies were evaluated using the QUADAS-2 tool [38], which is specifically designed for diagnostic accuracy studies.”
Use of Artificial Intelligence in Diagnosing Vertical Root Fractures—A Systematic Review
Alshahrani, A. S., Alelyani, A. A., Jabali, A. H., Malwi, A. A. A., Alroomy, R., Shaiban, A. S., Almnea, R. A., Mehta, V., & Moaleem, M. M. A. (2026) · Diagnostics · doi:10.3390/diagnostics16030406 · Cited by 6
Linhares, B. G., Linhares, D. G., Vale, R. G. D. S., & Gonçalves, D. M. (2026) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2026.103289 · Cited by 2
Come sintetizzare i risultati degli studi biomedici: una rassegna metodologica
PECORARO, V. (2026) · Biochimica Clinica · doi:10.23736/s0393-0564.26.00111-1 · Cited by 2
Parida, P., Mehta, A., Raj, E. A., Guruvare, S., Rao, M., Damerla, R. R., & Lewis, S. C. (2026) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2026.105161 · Cited by 2
The emerging role of mixed reality and artificial intelligence in sarcoma care: A systematic review
Joshi, S., Njessi, P., Camuzard, O., Gauci, M.-O., Bonvalot, S., & Lupon, E. L. (2026) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2026.111447 · Cited by 2
Helbling, C., Yeung, S., & DeMarco, M. L. (2026) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2026.111093 · Cited by 3
Tonsillar Asymmetry and Malignancy: A Meta‐analysis of Diagnostic Accuracy
Gao, E. Y., See, A. S. Y., Tan, B. K. J., Chan, S. W. D., Zhou, Y., See, A., Kiong, K. L., Chan, C. Y., Koh, L. H., Tan, H. K. K., et al. (2026) · Otolaryngology · doi:10.1002/ohn.70132 · Cited by 3
“26 Two authors independently graded study bias and applicability as low, high, or unclear, based on four key domains: patient selection, index test, reference standard, and fl ow and timing.”
Bharadwaj, H. R., Ali, S. H., Ali, H., Dalal, P., Gaur, A., Rayamajhi, S., Dhali, A., Akram, U., Koo, T. H., Shah, Y., et al. (2026) · Colorectal Disease · doi:10.1111/codi.70370 · Cited by 2
Laguna, G. G. D. C., Aguiar, M. F. S., Cordeiro, M. G. L., Gabbardo, G. Z. A., Lopes, P. M. O., Paulo, V. S., Evangelista, K. D. C., & Costa, D. T. (2025) · Jornal Brasileiro de Psiquiatria · doi:10.1590/0047-2085-2025-0037 · Cited by 2
Qiu, C., Cai, M., Lyu, L., & Xu, P. (2026) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.12.020 · Cited by 3
Hsiao, K., Lin, H., & Chen, C. (2026) · Cytopathology · doi:10.1111/cyt.70057 · Cited by 2
“The quality of individual studies was judged on the basis of the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [17].”
Ohannesian, V. A., Rajchenberg, D., Menezes, I. R., Han, M. L., Pereira, K. D. L. A., de Castro, W. C. N., Fagundes, A. F., Motta, R. F. O. S., Neto, M. J. F., Braga, C. A. P., et al. (2026) · Clinical Imaging · doi:10.1016/j.clinimag.2026.110743 · Cited by 2
Ardila, C. M., Pineda‐Vélez, E., & Vivares‐Builes, A. M. (2026) · Dentistry Journal · doi:10.3390/dj14020079 · Cited by 2
Mukminin, M. A., Chuang, L., Chen, P.-Y., Huan-xi, H., Rohmah, I., & Chiu, H. (2026) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2026.102254 · Cited by 5
Soto-Fajardo, C., Cervantes-Ramírez, R.-E., Montiel-Castañeda, C.-V., Morales-Meza, A.-R., Rojas-Abarca, D.-I., Sánchez-Zamudio, F.-B., Sandoval, H., & Pineda, C. (2026) · Frontiers in Immunology · doi:10.3389/fimmu.2026.1767181 · Cited by 2
Boers, N., Haverkamp, M., Eligh, A. M., Cabezas, M. C., Coert, J. H., & Rinkel, W. D. (2026) · JBJS Reviews · doi:10.2106/jbjs.rvw.25.00222 · Cited by 3
Walton, M., Llewellyn, A., Uphoff, E., Lord, J., Harden, M., Hodgson, R. M., & Simmonds, M. C. (2025) · Health Technology Assessment · doi:10.3310/gjms0317 · Cited by 3
Jayakody, N. K., Gordon, C. A., Wickramasinghe, N. D., Silva, A., Wickramasinghe, S., & Weerakoon, K. (2026) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0013974 · Cited by 2
“Two reviewers (NJ and KW) independently evaluated the risk of bias in each included article and reported it according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [33].”
Millán, F. P., Campo, M. C., Arroyo, J. A. D., Roig, M. C., Bartolomé, E. M., Haimovich, S., de la Blanca, E. P., Ziarrusta, G. B., Águeda, J. M. P., Zambrano, J. L. A., et al. (2026) · Journal of Minimally Invasive Gynecology · doi:10.1016/j.jmig.2026.02.021 · Cited by 2
Gierlotka, A., Bielecki, I., Sordyl, J., & Mizia-Malarz, A. J. (2026) · European Journal of Cancer Care · doi:10.1155/ecc/9403921 · Cited by 2
Kamal, M. M., Reshidi, B. M. A., Bedier, H. M., Albariqi, A. O., Almotrafie, W. A., Alshreef, B. S., Wahbi, M. O., Aly, W., Alyami, S. A., Abdallah, H., et al. (2026) · Cureus · doi:10.7759/cureus.103503 · Cited by 3
“The risk of bias and applicability concerns were evaluated using the QUADAS-2 tool [11].”
InfluentialDevcich, B. G., Ang, L.-M., Wang, M., & Larue, G. S. (2026) · Journal of Safety Research · doi:10.1016/j.jsr.2026.01.021 · Cited by 3
Biaggioni, P. A., & Gonzalez, C. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1376 · Cited by 2
“Both the risk of bias and concerns about applicability were rated as low, high, or unclear [18].”
Artificial intelligence–enhanced microsurgical training: a systematic review
Jamel, W. A., Jameel, M., Riaz, I. S. M., Yousif, Y. F., Rocio Perez, H., de la Torre, V. A., & Seth, I. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02452-5 · Cited by 2
“ThePredictionmodelRiskOfBiasAssessmentTool(PROBAST)tool was applied to evaluate prediction model studies, while Quality Assessment of Diagnostic Accuracy Studies, version 2 (QUADAS-2) was used for diagnosticaccuracystudies 55,56 .”
Virtual Autopsy in Medicolegal Investigations: A Systematic Review of Accuracy and Practical Utility
Nair, P. K. (2026) · International Journal of Applied and Basic Medical Research · doi:10.4103/ijabmr.ijabmr_332_25 · Cited by 2
Gelsolin as a diagnostic biomarker in non-small cell lung Cancer
Kazmi, I. A., Rahman, S., Ghamdi, S. A. H. A., Al-Zharani, M., Ashraf, T. H., Afzal, M., Nasr, F. A., Almutairi, F. M., & Alzarea, S. I. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.120916 · Cited by 2
Wee, M. A. T., Dobbe, J. G. G., Kievit, A. J., Schafroth, M. U., Maas, M. M., Blankevoort, L., & Streekstra, G. J. (2026) · Acta Orthopaedica · doi:10.2340/17453674.2026.45512 · Cited by 2
“Risk of bias and applicability for diagnostic ID-CT studies were evaluated with the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool [ 16 ] by 1 reviewer (MAtW).”
Mapping the degenerating intervertebral disc: a systematic review of histological evidence
Veronesi, F., Salamanna, F., Tedesco, G., Ruffilli, A., Rosa, F., Faldini, C., & Giavaresi, G. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1753988 · Cited by 2
Sheth, S. A. M., Lemoniatis, E., Ejaz, T., Kennedy, E., & Charalambous, G. (2026) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-026-07276-6 · Cited by 2
Wen, Q., Zhang, R., Zhu, Y., Ling, Y., & Xiong, D. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1636981 · Cited by 2
Gete, K. Y., Durga, P., Bekele, B. A., Tesfay, R. H., Jibat, N., Assefa, A. B., Gebre, M. E., Yimer, K. A., Kassahun, N. B. B., & Ayele, B. A. (2026) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-026-01897-0 · Cited by 2
Okwara, C., Black, T. A., Haff, P. L., Nammour, H. M., Bassett, R. L., Das, J. B., Qian, J. H., Schandua, H., Teixeira, A. J., Gonna, N., et al. (2026) · JAMA Dermatology · doi:10.1001/jamadermatol.2026.0071 · Cited by 3
Zhao, C., Zhang, Z., Wang, X., Zhang, T., Guo, S., Xin, Y., Zhu, G., & Hu, Z. (2026) · Scientific Reports · doi:10.1038/s41598-026-43461-4 · Cited by 3
“The quality of the included studies was independently assessed by two authors (CCZ and XJW) according to the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool 23 .”
Cheng, Y.-H., Dong, J., Wang, Z., Zhao, H., Chen, M., & Ma, T. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1748473 · Cited by 2
Benomar, A., Ghumman, S., Ouahdi, Y., Ghozy, S. A., Soliman, H., Zeng, K. L., Tseng, C., Detsky, J. S., Chen, H., Dinakaran, D., et al. (2026) · American Journal of Neuroradiology · doi:10.3174/ajnr.a9294 · Cited by 2
Almaabreh, O., Al-Dafi, R., Tabassum, A., Othman, A., & Abd-alrazaq, A. (2026) · Journal of Medical Internet Research · doi:10.2196/78377 · Cited by 3
“To evaluate the quality and reliability of the included studies, two reviewers independently conducted a risk of bias assessment using an adapted version of the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool [19].”
Vrieze, M. D., Zhang, N., Seibold, P., Gerhäuser, C., Albers, P., & Krilavičiūtė, A. (2026) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-25-1820 · Cited by 2
Bayu, P., Prasetiyo, P. D., & Wijaya, J. H. (2026) · Cancers · doi:10.3390/cancers18060960 · Cited by 2
Artificial Intelligence in ALK-Rearranged NSCLC: Forecasting Response and Resistance
Koulouris, A., Tsagkaris, C., Kalaitzidis, K., Tsakonas, G., & Mountzios, G. (2026) · Cancers · doi:10.3390/cancers18060973 · Cited by 2
“Instead, a structured qualitative risk-of-bias assessment was performed based on methodological domains commonly considered in AI prediction research and inspired by established frameworks such as QUADAS-2 and PROBAST [27–29].”
Werid, G. M., Ibrahim, Y. M., Wubshet, A. K., Aleri, J. W., Hemmatzadeh, F., & Petrovski, K. R. (2026) · Animals · doi:10.3390/ani16060960 · Cited by 2
Wan, Q.-C., Min, K.-Y., Wei, L., Xie, L., & Ji, B. (2026) · Prostate Cancer and Prostatic Diseases · doi:10.1038/s41391-026-01103-w · Cited by 2
“The quality of the included studies was assessed based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [20].”
Arachchige, A. S. P. M., Alves, G. A. M., Zal, A., D’Acunto, G., Węglarz, M., Voicu, O., Maffei, E., & Cademartiri, F. (2026) · Diagnostics · doi:10.3390/diagnostics16060937 · Cited by 2
“…than QUADAS-2, which is primarily designed for diagnostic accuracy studies with clearly defined index tests, reference standards, and clinical outcomes, and may not be fully applicable to exploratory technical imaging investigations without standardized comparators or accuracy endpoints [13].”
Diffusion-weighted imaging of bone and soft tissue tumors: a systematic review
Mittal, M., Sharma, R., Kim, L., Bankston, M. E., Weinschenk, C., Chhabra, A. B., & Weinschenk, R. C. (2026) · Acta Radiologica · doi:10.1177/02841851261429386 · Cited by 2
“This modi fi cation was made to ensure QUADAS-2 was applied appropriately for each topic discussed in this systematic review (20).”
Li, T., Ma, J., Pang, C., Wang, Y., Li, F., 耿云平, & You, G. (2026) · Academic Radiology · doi:10.1016/j.acra.2026.03.006 · Cited by 2
Lim, C. T., Pruijt, M., Lim, G., van Etten‐Jamaludin, F. S., Teichert, C., de Voogd, F. A. E., D’Haens, G., Christensen, B., Maconi, G., & Gecse, K. B. (2026) · Journal of Crohn s and Colitis · doi:10.1093/ecco-jcc/jjag032 · Cited by 2
Ramos-Morro, O. D., Mareque-Ameijeiras, S., Giovannini, G., Paz-Cortés, M. M., Serrano-Velasco, D., Aragoneses, J. M., & Martín-Vacas, A. (2026) · Frontiers in Oral Health · doi:10.3389/froh.2026.1733387 · Cited by 2
Daniel, J., Narayanan, M. K. S., Srinivasalu, V. A., Bhaskar, A., Suresh, S., Daniel, B. D., Ramraj, B., Nair, D., James, D., Vasudevan, S., et al. (2026) · Systematic Reviews · doi:10.1186/s13643-026-03166-1 · Cited by 2
“The methodological quality of the selected studies will be assessed independently by teams of two reviewers using the QUADAS-2 tool [28].”
Fuller, G. W., Baird, J., Keating, S., Miller, J., Pilbery, R., Scotney, N., McKnee, K., Turner, J., Lecky, F. E., Edwards, A., et al. (2026) · PLoS ONE · doi:10.1371/journal.pone.0344996 · Cited by 3
“A detailed critical appraisal of potential biases, classified according to QUADAS-2 criteria, is provided in the supplementary materials (S6 Table) [40].”
Few FDA Approved AI/ML Orthopaedic Devices Have EU MDR Equivalents or Peer-Reviewed Validation
Bracken, A., Whelehan, S. P., Merghani, K., Sheehan, E. C., & Feeley, I. H. (2025) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000003788 · Cited by 2
Liu, L., Hou, J., Tao, Y., Zhou, G., Xiao, L., Li, J., Liu, F., Quan, S., Zhang, Q., & Zhang, D. (2026) · Journal of Wound Care · doi:10.12968/jowc.2025.0340 · Cited by 2
Srivali, N., & Cheungpasitporn, W. (2026) · Sleep Medicine · doi:10.1016/j.sleep.2026.108941 · Cited by 4
Yadav, N. K., Singh, S., Singhal, S., Sajimon, S., Ragunath, R., & Garcha, A. S. (2026) · IP International Journal of Ocular Oncology and Oculoplasty · doi:10.18231/j.ijooo.14754.1773837023 · Cited by 2
Tietz, L., Weissheimer, T., Rõsing, C. K., & Só, M. V. R. (2026) · International Endodontic Journal · doi:10.1111/iej.70156 · Cited by 3
Warych, M., Zabłocki, J., Krawczyk, J., Herc, J., Wieniawski, P., & Pietrzak, R. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15082883 · Cited by 2
Azmi, A., McArthur, A., McDonald, S., Hareendranathan, A. R., & Jaremko, J. L. (2026) · Pediatric Radiology · doi:10.1007/s00247-026-06601-6 · Cited by 2
Wearable ECG and PPG for anxiety detection: a translational digital medicine perspective
Elgendi, M., Elkhalifa, A., Alhashmi, N., Aldahmani, A., Aljneibi, N., Alamro, D., Jelinek, H. F., Khandoker, A. H., & Ward, R. K. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02620-7 · Cited by 3
Nagasawa, K., Nihashi, T., Iwata, M., & Terasawa, T. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-103045 · Cited by 2
Leketas, M., Stonkutė, I., Miškinytė, M., & Afanasjevas, D. (2026) · Healthcare · doi:10.3390/healthcare14081066 · Cited by 2
de Andrade, J. B. C., Froio, N. D. L., Nascimento, P. S., Querobin, S. O., de Oliveira, N. S., & Carneiro, T. S. (2026) · Neurocritical Care · doi:10.1007/s12028-026-02509-z · Cited by 4
“Application of the QUADAS-2 tool [13] to diagnostic accuracy studies revealed generally high methodological quality in key domains.”
Sahafi, A., Koulaouzidis, A., & Naemi, A. (2026) · Diagnostics · doi:10.3390/diagnostics16091269 · Cited by 2
Hildebrand, L., Clarke, L. M., White, S. J., Perperidis, A., Gorayski, P., Doig, M., & To, M. (2026) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2026.112021 · Cited by 2
Gupta, D., Hegde, V., Shaw, A. K., Mali, S. D., Patil, A. H., & Priyadarshini, S. R. (2026) · Saudi Endodontic Journal · doi:10.4103/sej.sej_257_25 · Cited by 2
Mehta, V., Vathani, A., Kamma, P. K. G., Chaturvedi, S., Mathur, A. S., & Noor, T. (2026) · Clinical and Experimental Dental Research · doi:10.1002/cre2.70370 · Cited by 2
“Two reviewers (A.N.V.J. and S.C.) independently and in duplicate evaluated the risk of bias and applicability concerns in the primary diagnostic accuracy studies included in the analysis, utilizing the QUADAS‐2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool (Whiting et al. 2011).”
Pentraxin-3 as a diagnostic and prognostic biomarker in inflammatory lung diseases
Singh, Y., Gupta, A., Gupta, S., Goud, P., Pandey, S. N., Goyal, K., Kumbhar, P., Singh, S. K., Dua, K., & Gupta, G. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121044 · Cited by 2
Pugliesi, R. A., Mansour, K. B., Apitzsch, J., Maalouf, N., Krysiak, R. G., Andrisani, A., Billone, V., Ferrero, S., & Gullo, G. (2026) · Surgical Oncology · doi:10.1016/j.suronc.2026.102444 · Cited by 2
Diagnostic Accuracy and Complementary Value of Biomarkers for Primary Vitreoretinal Lymphoma
Lou, Y., Ma, C., Zhang, X., Zhang, M., Chai, H., Zhao, Y., & liu, X. (2026) · Ophthalmology · doi:10.1016/j.ophtha.2026.04.034 · Cited by 2
Glinkowski, W., Kamiński, P., & Obuchowicz, R. (2026) · Diagnostics · doi:10.3390/diagnostics16101420 · Cited by 2
“Instead, potential sources of bias and methodological limitations were qualitatively considered during the synthesis, informed by established frameworks for diagnostic accuracy studies, including QUADAS-2 and emerging AI-specific reporting guidance [42,43].”
Alharbi, A. A., & Altherwi, T. I. (2026) · Eurasian Journal of Medicine and Oncology · doi:10.36922/ejmo.8319 · Cited by 2
Guo, K., Ku, J. C.-K., Yang, Y., McGrath, C. P. J., & Lam, P. P. Y. (2026) · Journal of Evidence Based Dental Practice · doi:10.1016/j.jebdp.2026.102306 · Cited by 2
Urrego, J. D. R., Parra-López, C., Isaza-Ruget, M. A., & Pacheco, Y. (2026) · Frontiers in Genetics · doi:10.3389/fgene.2026.1716692 · Cited by 2
“The methodological quality and risk of bias of the included diagnostic studies were independently assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (Whiting et al., 2011).”
Sadus, T., Matrai, S. P., Luca, F. D., Martin, H., & Delgado, A. F. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016353 · Cited by 2
Mustakin, Arief, M., Nurahmi, & Kurniawan, L. B. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113318 · Cited by 2
Diagnostic Performance of FAPI PET in Patients with Breast Cancer: A Systematic Review
Duijx, L. E. H. W., Lenaerts, M., Smidt, M. L., Vaz, S. C., Backhaus, P., Bauwens, M., Mottaghy, F. M., Wildberger, J. E., & van Nijnatten, T. J. A. (2026) · Journal of Nuclear Medicine · doi:10.2967/jnumed.126.272191 · Cited by 2
Yadav, R., Banerjee, D., & James Raj, K. (2026) · Middle East Fertility Society Journal · doi:10.1186/s43043-026-00334-0 · Cited by 2
“The methods of validation used were also quite diverse; the majority of the studies used only internal validation methods such as k-fold cross-validation or a holdout test set, whereas only a small number of studies used external validation meth-ods on separate datasets from multiple centers [24].”
InfluentialZawadka, M., Czarnik, T., Gawda, R., Miłobędzka, M., Trzebicka, J., Królicki, T., Owczuk, R., Czuczwar, M., Białka, S., Gola, W., et al. (2026) · Anaesthesiology Intensive Therapy · doi:10.5114/ait/220388 · Cited by 2
“…the Risk of Bias-2 (RoB-2) tool [7] was used; for diagnostic studies, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) scale [8] was used; and for publications evaluating the effect of positioning on cannulation conditions, a custom study quality assessment tool was designed.”
af Burén, S., Romdhani, N. S., Ulaner, G. A., Yeh, R., Tran, T. A., Axelsson, R., & Altena, R. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112961 · Cited by 2
Patil, S., Licari, F. W., Bhandi, S., & Venkataiah, V. S. (2026) · Odontology · doi:10.1007/s10266-026-01412-5 · Cited by 2
Agostinho, M., Borges, M., Pereira, T. S., Borges, D. F., & Soares, J. I. (2026) · Behavioral Sleep Medicine · doi:10.1080/15402002.2026.2673893 · Cited by 2
CT-Based Radiomics in the Characterization of Solid Renal Tumors: A Systematic Review
Koumpis, P., Vartholomatos, E., Romeo, E., Alexiou, G. Α., Argyropoulou, M. I., & Tsili, A. C. (2026) · Cancers · doi:10.3390/cancers18111758 · Cited by 3
Chen, J., Marwick, T. H., & Soh, C. H. (2026) · American Journal of Preventive Cardiology · doi:10.1016/j.ajpc.2026.101691 · Cited by 3
“The risk of bias assessment was conducted using the QUADAS-2 tool [4].”
Warren, T., van der Weegen, W., Kool, R. B., Hoogendoorn, M., & Timmers, T. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106525 · Cited by 2
Gibson, B. N., Chodapuneedi, S., Koh, H. Y., Gupta, S., Gašević, D., Wang, A. Y., Marzolini, C., Khoo, S., Romero, L., Dalli, L. L., et al. (2026) · British Journal of Pharmacology · doi:10.1111/bph.70515 · Cited by 3
“…quality and potential risk of bias in the included studies, we employed the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) and QUADAS-C tools, which are widely used for evaluating diagnostic accuracy and comparative studies, respectively (Whiting et al., 2011; Yang et al., 2021).”
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.