QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 10,801–10,900 of 14,770
Damkjær, M. W., Laursen, D. R. T., Elkjær, M., Gerke, O., Lundh, A., Hróbjartsson, A., & Schroll, J. B. (2025) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2025.07.009 · Cited by 2
Junior, L. C. D. L. D., de Souza, D. L., Bezerra, A. P., Corrêa, M., Teixeira, C. D. S., Bortoluzzi, E. A., & Garcia, L. D. F. R. (2025) · International Journal of Dentistry · doi:10.1155/ijod/8824867 · Cited by 2
“For this systematic review, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [25] was adapted, as certain questions (e.g., patient randomization and the index test threshold) were not applicable.”
Monteiro, M. D. C., Ostolin, T. L. V. D. P., Pérez‐Cruz, M., & da Rocha, L. S. N. (2025) · Prenatal Diagnosis · doi:10.1002/pd.6862 · Cited by 3
“…of the studies were evaluated independently by the same reviewers using the Quality Assessment of Studies of Diagnostic Accuracy Included in Systematic Reviews (QUADAS‐2) tool [21], which evaluates four key domains: patient selection, index test, reference standard, and flow and timing.”
Al-Rumaihi, G., Khan, M. M., Saleh, A., Ali, A., Al-Romaihi, L., Al-Jaber, N., Al-Suliaiti, G., Chowdhury, M. E. H., Babu, G. R., & Pedersen, S. (2025) · Cureus · doi:10.7759/cureus.88915 · Cited by 6
“…review, we conducted a comprehensive assessment of the methodological rigor of the chosen studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [19,20], which is crucial to ensure the reliability and applicability of findings in the field of medical diagnostic research.”
Waki, R., Haketa, S., Aburaki, R., & Horita, N. (2025) · Cancers · doi:10.3390/cancers17152544 · Cited by 2
“The quality of the included studies and the risk of bias were assessed using the QUADAS-2 tool [28].”
Baptista, J. M., Brenner, L. B. O., Koga, J. V., Ohannesian, V. A., Ito, L. A., Nabarro, P. H., Santos, L. P., Henrique, A., Almeida, G. D. O., Berbet, L. U., et al. (2025) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2025.110624 · Cited by 2
Dean, B. W., Geropoulos, G., Richardson-Jones, T., Fornasiero, M., Papapanou, M., Konstantinidis, C. I., Madouros, N., Spinos, D., Koimtzis, G. D., Giannis, D., et al. (2025) · World Journal of Clinical Cases · doi:10.12998/wjcc.v13.i27.104916 · Cited by 5
“The included studies were assessed by the standardized Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool[20].”
Sood, A., Narayan, B., Raghavan, S., Mishra, D., Surya, V., & Mehrotra, R. (2025) · Journal of the American Society of Cytopathology · doi:10.1016/j.jasc.2025.07.011 · Cited by 2
Exosomal RNA biomarkers in pancreatic ductal adenocarcinoma: Systematic review and meta-analysis
Tiyuri, A., Hatami, H., Mobarezi, Z., Zareardalan, M., Salari, G., Abadi, A. Z. A., Mirzazad, M., Mojaveri, A. E., & Jafari, D. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120532 · Cited by 2
Cohen, S., Zantvoord, J., de Boer, T., Mattila, T., van Wingen, G. V., & Denys, D. (2025) · Psychological Medicine · doi:10.1017/s0033291725101335 · Cited by 1
“We evaluated the risk of bias and applicability of the results with the quality assessment tool for diagnostic accuracy studies (QUADAS) 2 tool (Whiting et al., 2011).”
Ma, C., Wang, Y., Ding, Z., Liang, X., Yuan, M., Liu, X., Li, Q., Lv, H., Qiao, N., & Liu, X. (2025) · Oncology Letters · doi:10.3892/ol.2025.15225 · Cited by 2
Loy, L. M., Acharyya, S., Low, H. M., Pua, U., & Tan, C. H. (2025) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2025.08.006 · Cited by 2
Liu, S., Chen, H., Song, Z., Guo, Q., Zhang, X., Shi, B., Zhai, S., Zhang, L., Miao, L., Cui, L., et al. (2025) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b2400069 · Cited by 2
Baarsen, A. M., van den Broek, N., Hilgenkamp, T. I. M., Festen, D. A. M., Elbers, R. G., & Huisman, S. A. (2025) · Journal of Sleep Research · doi:10.1111/jsr.70148 · Cited by 2
“To assess the risk of bias in the included studies, the QUADAS-2 (Whiting et al. 2011) (Quality Assessment of Diagnostic Accuracy Studies) was used.”
Li, N., Wu, M., & Li, Y. (2025) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2025-0078 · Cited by 3
Lu, J., Xu, X., Zhang, Y., Zhuang, K., Fang, T., Zhang, C., Chen, K., Huang, X., & Li, Y. (2025) · Clinical Breast Cancer · doi:10.1016/j.clbc.2025.08.013 · Cited by 3
de la Torre, E. C., & Pinto, E. P. (2025) · Children · doi:10.3390/children12091106 · Cited by 2
Aghayan, A. H., Arab, A., Haddadi, S., & Atashi, A. (2025) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2025.102048 · Cited by 2
Waters, C., Hall, T., Temperley, H. C., Jones, H., O’Sullivan, N. J., McHugh, A., Tohidinezhad, F., & Subramaniam, T. (2025) · Clinical Otolaryngology · doi:10.1111/coa.70031 · Cited by 3
“Quality assessment of the included studies was performed according to the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and Radiomics Quality Score (RQS) [13, 19, 20].”
InfluentialBreast Cancer Detection Algorithms: A Comparative Review of Leading Artificial Intelligence Models
Bojnordi, T. E., Pourali, S., Haghighat, F., Rad, F. N., Padash, Y., & Sharafkhah, A. (2025) · InfoScience Trends · doi:10.61882/ist.202502.08.05 · Cited by 2
Is blood the new stool? Status of blood tests for CRC screening
Symonds, E. L., Dix, M., Wassie, M. M., Bulamu, N. B., Young, G. P., & Winter, J. M. (2025) · Best Practice & Research Clinical Gastroenterology · doi:10.1016/j.bpg.2025.102049 · Cited by 3
Elhaie, M., Koozari, A., & Alshammari, Q. T. (2025) · Die Radiologie · doi:10.1007/s00117-025-01513-2 · Cited by 2
Methodology for research and scientific publication in pediatrics. Main methodological designs
Pérez‐Moneo, B., Olcina, M. J. E., Villar, S. F., Rodríguez, C. B., Rubio, M. V. M., & Arias, M. M. (2025) · Anales de Pediatría (English Edition) · doi:10.1016/j.anpede.2025.503933 · Cited by 2
Hollander, A. V., & NONAKA, T. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1569877 · Cited by 2
Gkampenis, A., Koukoulithras, I., Lampros, M. G., Zagorianakou, P., Voulgaris, S., & Alexiou, G. Α. (2025) · Journal of Ultrasound · doi:10.1007/s40477-025-01076-x · Cited by 2
A literature review on disease detection with automated machine learning
Eryılmaz, E. E., & Kılıç, E. (2025) · PeerJ Computer Science · doi:10.7717/peerj-cs.3193 · Cited by 2
Darrudi, R., Hosseini, A., Emami, H., Roshanpoor, A., & Nahayati, M. (2025) · Medicine · doi:10.1097/md.0000000000044493 · Cited by 4
“[20] Table 1 Basic information of included studies.”
Influentialde Barros, I. C., Fernandes, M. V., Villafuerte, S. R., & Brandão, A. B. D. M. (2025) · World Journal of Hepatology · doi:10.4254/wjh.v17.i9.111126 · Cited by 2
Alsabri, M., Elkarargy, M. A., Ata, I. M., Khalifa, M., Hamid, A. K., Elsnhory, A. B., Abdelwahab, O. A., & Urbon, S. C. (2025) · BMC Emergency Medicine · doi:10.1186/s12873-025-01347-0 · Cited by 2
“Then they assessed the risk of bias using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [8] (Supplementary Table S3) and the Newcastle-Ottawa Scale (NOS) tool [9].”
Artificial Intelligence to Detect Developmental Dysplasia of Hip: A Systematic Review
Bhavsar, S., Gowda, B. B., Bhavsar, M., Patole, S., Rao, S. C., & Rath, C. P. (2025) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.70172 · Cited by 6
Harnan, S., Biz, A. N., Hamilton, J., Whyte, S., Simpson, E. L., Ren, S., Cooper, K. L., Clowes, M., Abulafi, M., Ball, A., et al. (2024) · Health Technology Assessment · doi:10.3310/ahpe4211 · Cited by 16
Allenzara, A., Stachowski, J., Jones, E. P., Nelson, A. E., & Foulke, G. (2025) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2025.152830 · Cited by 2
Forensic significance of condom traces in sexual assault investigations: A systematic review
Мусабекова, С. А., Frascione, N., & Assylbayeva, L. B. (2025) · Science & Justice · doi:10.1016/j.scijus.2025.101341 · Cited by 2
Rodriguez, N. G., Mercado, N. C., Panjiyar, K., & Kunwor, R. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1634694 · Cited by 3
Yang, Y., Zhao, X., Zhao, P., Ying, D., Wang, J., Jiang, Y., & Wan, Q. (2025) · BMJ Evidence-Based Medicine · doi:10.1136/bmjebm-2025-113759 · Cited by 3
“Following the recommendation of QUADAS-2 developers, who discourage creating an overall quality score, 8 we selected domains with greater variability to guide subgroup”
Danaei, S., Dehghanian, Z., Meftah, E., Naderi, N., Safavi‐Naini, S. A. A., Khorasanizade, F., & Rabiee, H. R. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001567 · Cited by 2
Capraș, R.-D., Badea, I. C., Moldovan, M. A., Gaia‐Oltean, A. I., Badea, A.-F., & Telecan, T. (2025) · Healthcare · doi:10.3390/healthcare13202548 · Cited by 3
Wongrith, P., Dangkrajang, S., & Nam, T. T. (2025) · Diabetes Mellitus · doi:10.14341/dm13324 · Cited by 2
Guedes, I. H. L., Uvinha, F., Costa, I. L., de Ferreira, G. M., Azevedo, L. C. P., & Lins, P. R. G. (2025) · Einstein (São Paulo) · doi:10.31744/einstein_journal/2025rw1555 · Cited by 2
Kang, S. K., Brooks, E., Wolk, R. A., Siriruchatanon, M., & Kerr, A. R. (2025) · Oral Oncology · doi:10.1016/j.oraloncology.2025.107535 · Cited by 2
da Luz-Silva, G., Castellaci, J. C. D. O. S., Veit, T. D., & Visioli, F. (2025) · Journal of Oral and Maxillofacial Surgery Medicine and Pathology · doi:10.1016/j.ajoms.2025.10.005 · Cited by 3
Elhaie, M., Koozari, A., Koohi, H., & Albeshan, S. M. (2025) · Journal of Medical Imaging and Interventional Radiology · doi:10.1007/s44326-025-00082-x · Cited by 2
“The methodological quality of included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool for diagnostic studies and the Radiomics Quality Score (RQS) 2.0 for radiomics-based ML studies [23].”
InfluentialAlrasheed, A. S., Almutairi, R. A., Khoja, R. H., Baeesa, S. S., Alves, O. L., Alhalal, I. A., & Alsalmi, S. O. (2025) · The International Journal of Spine Surgery · doi:10.14444/8801 · Cited by 2
Koopaie, M., Fatahzadeh, M., & Kolahdooz, S. (2025) · Journal of Oral Microbiology · doi:10.1080/20002297.2025.2571188 · Cited by 2
Niznik, T., York, A. A., Bialek, S., Kimmell, M., Ho, J., Battiste, J. D., Dunn, I. F., Zuccato, J., & Graffeo, C. S. (2025) · Neurosurgery · doi:10.1227/neu.0000000000003813 · Cited by 4
Huang, Y.-E., Huang, C.-K., Huang, Y.-T., & Tseng, J. (2025) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000006349 · Cited by 2
The Operative Role of Artificial Intelligence in Vascular Surgery: A Systematic Review of Literature
Abara, N., Mustapha, A., Kalichetty, R., & Elsaigh, M. (2025) · Cureus · doi:10.7759/cureus.95515 · Cited by 2
“Furthermore, the first three domains are evaluated for concerns regarding applicability [12]. software (Microsoft, Redmond, WA, USA).”
Influential2025 ICM: Diagnostic Imaging for Periprosthetic Joint Infection
Noor, S., Megaloikonomos, P. D., Abedi, A. A., Abbaszadeh, A., Adi, M. M., Farii, H. A., Aliyev, H., Alizadeh, C., bin Shakeel, M. S., Borjón, E. D., et al. (2025) · The Journal of Arthroplasty · doi:10.1016/j.arth.2025.10.083 · Cited by 2
Huang, S.-M., Yeh, Y.-H., Sun, C., & Chu, H.-W. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14217726 · Cited by 2
“The same two independent reviewers (SMH and YHY) assessed the risk of bias for the included studies using the Quality Assessment of Diagnostic Accuracy Studies—2 (QUADAS-2) tool [21], specifically tailored to this systematic review.”
Silva, M. H. L. E., Ramos, P. V. N., dos Santos, D. S. R., da Silva, M. A. B., do Amaral, F. A., & Mamede, M. H. (2025) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-025-07640-1 · Cited by 2
Ayaz, A., Hashmi, S. A., Ibrahim, M., Sharma, S., Abbas, M. A., & Zawar, I. (2025) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2025.110794 · Cited by 4
van Hees, J. E., Vlaming, M., Flach, R. N., Stathonikos, N., Suelmann, B. B. M., Meijer, R. P., Willemse, P.-P. M., & van Diest, P. J. (2025) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2025.105011 · Cited by 2
Masood, S., Shaikh, A., & Brar, Y. (2025) · Cureus · doi:10.7759/cureus.96824 · Cited by 2
“For diagnostic accuracy investigations, the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [12] framework was applied, evaluating bias in patient selection, index tests, reference standards, and study flow.”
Hajikarimloo, B., Mohammadzadeh, I., Shirzadi, P., Tos, S. M., Mortezaei, A., & Habibi, M. A. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-025-01757-3 · Cited by 3
“Two independent authors conducted the risk of bias (RoB) assessment with the “Quality Assessment of Diagnostic Accuracy Stud-ies-2” (QUADAS-2) tool [12].”
D’Alberti, E., Mascio, D. D., Giancotti, A., Impey, L. W. M., Stabile, G., Papageorghiou, A. T., Rizzo, G., & Stampalija, T. (2025) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2025.101845 · Cited by 3
Pahlevan‐Fallahy, M., Hosseinzadeh, N., Shaker, F., Asgari, A.-M., Athar, M. M. T., & Rouzrokh, P. (2025) · Skeletal Radiology · doi:10.1007/s00256-025-05078-y · Cited by 2
“A. using the QUA-DAS-2 tool [16].”
Huang, S., Liu, X., Zhu, L., & Ai, K. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-05296-x · Cited by 2
Lewis, S., Peeraully, R., Ghazy, E., Corbett, H. J., Maconochie, I. K., Kenny, S. E., & Harwood, R. (2025) · British Journal of Urology · doi:10.1111/bju.70080 · Cited by 2
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [12] was used to assess studies describing the performance of clinical risk scores and US.”
Montero, J. A., & Rico-Jiménez, M. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112538 · Cited by 2
Dantic, D. E., Jaya, R. S., Gafoor, R., & Marston, L. (2025) · Journal of Affective Disorders Reports · doi:10.1016/j.jadr.2025.100999 · Cited by 4
Wang, Y., Chen, C., Gao, Y., Hu, Q., Gao, P., Zheng, Q., Wang, L., Xie, Z., & Chen, X. (2025) · European Journal of Cancer · doi:10.1016/j.ejca.2025.116118 · Cited by 2
Wang, Z., Chang, F., Wu, H., Yuan, X., Chen, Y., & Han, J. (2025) · Clinical Colorectal Cancer · doi:10.1016/j.clcc.2025.09.004 · Cited by 4
Buonocore, S., Pommella, M., Bettiol, A., MASI, S. D., & Barba, C. (2025) · Epileptic Disorders · doi:10.1002/epd2.70137 · Cited by 2
Hasanain, M., Akram, A., Kabir, A., Javed, H., Usman, M. A., Jaffar, H., Khan, A. A., Malik, G. M. A., Tabassum, M., Faizan, M., et al. (2025) · Sleep And Breathing · doi:10.1007/s11325-025-03544-4 · Cited by 3
“The risk of bias and applicability across studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool for diagnostic tests [21].”
Singh, S., Charan, M. L., Vojjala, N., Kaur, P., Mahesh, K. V., Soundappan, K., Takkar, A., Prakash, G., Gupta, V., & Lal, V. (2025) · Annals of Indian Academy of Neurology · doi:10.4103/aian.aian_335_25 · Cited by 2
“The Quality Assessment of Diagnostic Accuracy Studies‑2 (QUADAS‑2) [17] tool was used to assess the quality of diagnostic accuracy of the included studies by NV and PK.”
Baksa, B., Reddy, S. S., Bundula, S., Nagy, K., Beke, S., Száraz, L., Györke, T., & Maurovich‐Horvat, P. (2025) · EANM Innovation · doi:10.1186/s13550-025-01335-2 · Cited by 2
“Risk of bias was assessed using the QUADAS-2 tool across four domains (patient selection, index test, reference standard, and flow/timing), following standard criteria tailored to the specific study settings [15].”
Babbitt, K., Funnell, E. L., Martin-Key, N. A., Barker, E., & Bahn, S. (2026) · JMIR Research Protocols · doi:10.2196/73492 · Cited by 2
“To evaluate the quality of the selected studies, the Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) is being used [26].”
Quazi, T., Rashid, H., Shah, A. M., & Khalid, E. (2025) · Swiss Journal of Radiology and Nuclear Medicine · doi:10.59667/sjoranm.v25i1.16 · Cited by 2
Sun, Y., Li, B., Ju, C., Hu, L., Sun, H., An, J., Kim, T.-H., Bu, Z., Shi, Z., Liu, J., et al. (2025) · JMIR Medical Informatics · doi:10.2196/78644 · Cited by 3
“On the other hand, 13 [ The RoB and concerns regarding applicability for each included study were rigorously assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [33].”
Salimi, M., Vadipour, P., Abdolizadeh, A., Fayedeh, F., & Seifi, S. (2025) · BMC Medical Imaging · doi:10.1186/s12880-025-02068-3 · Cited by 2
“To evaluate the quality of the included studies, two primary assessment tools were utilized: QUADAS-2 [24] and the Methodological Radiomics Score (METRICS) [25].”
Gebeyehu, T. F., Alvani, M. S., Failla, G., Sami, A., Shah, Y., Kharichev, A., Dian, J. A., Matsoukas, S., Vaccaro, A. R., Schroeder, G. D., et al. (2025) · Spinal Cord · doi:10.1038/s41393-025-01155-0 · Cited by 2
“Quality of development and ROB for diagnostic models was assessed utilizing the domains of quality assessment of diagnostic accuracy studies (QUADAS-2) tool [16] with a custom modi fi cation based on PROBAST + AI and another study suggesting areas of potential bias for AI based diagnostic tools [17].”
Song, D., Zhang, P., Meng, T., Yao, J., & Sheng, M. (2025) · Clinical and Experimental Optometry · doi:10.1080/08164622.2025.2597413 · Cited by 2
“The methodological quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool proposed by Whiting et al. 15 This tool assesses risk of bias and concerns regarding clinical applicability.”
Akram, N., Karimaghaei, D., Mattoo, S., Selvarajan, D. P., & Radha, S. S. (2025) · Cureus · doi:10.7759/cureus.98486 · Cited by 2
“Methodological quality was appraised using AI-specific adaptations of QUADAS-AI for diagnostic accuracy studies and PROBAST-AI for prediction and measurement models [16,17].”
Xie, C., Zhang, H., Feng, B., & Wang, Q. (2025) · Annals of Nuclear Medicine · doi:10.1007/s12149-025-02136-2 · Cited by 2
Vrotniakaite-Bajerciene, K., Mallick, R., Takada, T., Kraaijpoel, N., van Smeden, M., Moons, K. G. M., Kline, J. A., Huisman, M. V., Martens, E., Righini, M., et al. (2025) · Journal of Thrombosis and Haemostasis · doi:10.1016/j.jtha.2025.10.035 · Cited by 2
Monserratt, L. H., Morales, J. A., Mohammed, A., Ovalle-Eliseo, S., Islas-Huerta, G., Perez, L. A., & Díaz‐Santos, M. (2025) · Alzheimer s & Dementia · doi:10.1002/alz.70918 · Cited by 2
“76 The patient selection domain assesses whether participants were chosen in a manner that avoided bias.”
van de Laar, B. C. T., Sikkenk, D. J., Kats‐Ugurlu, G., de Groot, D. J. A., Nagengast, W. B., & Consten, E. C. J. (2025) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2025.105089 · Cited by 2
Ocampo-Navia, M. I., Agudelo-Arrieta, M., Marín-Navas, F., Taub-Krivoy, A., Perez-Mendez, W., Arana-Isaac, N., Mitre, L. P., & Feo-Lee, O. H. (2025) · Neurosurgical Review · doi:10.1007/s10143-025-03947-7 · Cited by 2
“The risk of bias and applicability concerns of the included studies were assessed using the Quality Assessment of Diag - nostic Accuracy Studies 2 (QUADAS-2) [ 22 ].”
Arráez‐Aybar, L. A., García-de-Pereda-Notario, C. M., Palomeque-del-Cerro, L., & Montoya, J. J. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10040478 · Cited by 2
Zhong, X., Yang, H., Zhang, R., Xie, L., & Luo, R. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1712404 · Cited by 2
Quader, T., Pai, S., Tan, Y. M., Deshmukh, H., Malabu, U. H., & Emeto, T. I. (2025) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-025-01820-4 · Cited by 2
“Each domain has one query in relation to the risk of bias (guided by several signalling questions) or applicability which are rated as either “low”, “high” or “unclear”[10 ].”
InfluentialChen, K., Xue, M., Meng, X., Li, G., Wang, X., Long, Y., & Li, H. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000004443 · Cited by 4
Hersi, L., Kant, T., Kaziev, C. L., Farrar, D. S., Bryan, N., Cunningham, J., Mtaweh, H., Mahant, S., Morris, S. K., & Gill, P. J. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.50298 · Cited by 3
Analysis of Statistical Biases in Studies Used to Formulate Guidelines
Cook, T. S., Zimmerman, S. L., & Jha, S. K. (2015) · Academic Radiology · doi:10.1016/j.acra.2015.04.009 · Cited by 2
Lazăr, A. M., Pini, C., Sollini, M., Wang, H., Li, B., Belcari, N., & Chiti, A. (2025) · EANM Innovation · doi:10.1016/j.eanmi.2025.100006 · Cited by 2
Borges, G. L., Tardelli, J. D. C., Botelho, A. L., & dos Reis, A. C. (2025) · Heliyon · doi:10.1016/j.heliyon.2025.e44288 · Cited by 2
AMSTAR-PF: a critical appraisal tool for systematic reviews of prognostic factor studies
Henry, M. L., O'Connell, N. E., Riley, R. D., Moons, K. G. M., Shea, B., Hooft, L., Damen, J. A., Skoetz, N., Wallwork, S. B., & Moseley, G. L. (2025) · BMJ · doi:10.1136/bmj-2025-085718 · Cited by 2
Hassankhani, A., Valizadeh, P., Jannatdoust, P., Amoukhteh, M., Mohammadi, A., Bilgin, C., Gholamrezanezhad, A., & Haq, A. (2025) · Clinical Imaging · doi:10.1016/j.clinimag.2025.110706 · Cited by 2
Qafesha, R. M., Hindawi, M. D., Sharabati, I., Dervis, M., Najah, Q., Albostani, A., & Ali, A. H. G. (2025) · British Journal of Radiology · doi:10.1093/bjr/tqaf309 · Cited by 2
Diagnostic performance of artificial intelligence in detecting bladder carcinoma
Yuan, S., Yang, K., Wu, H., Peng, L., Li, R., Deng, D., & Liu, X. (2025) · World Journal of Urology · doi:10.1007/s00345-025-06144-9 · Cited by 2
“To evaluate the methodological quality of the included studies, we employed the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool, which consists of 14 items that assess the risk of bias and concerns regarding applicability across key domains [ 19].”
Shang, J., Wang, C., Li, N., Wu, Y., Chen, Y., Zhang, Z., Dong, J., Wei, C., Zhou, L.-P., Hong, W., et al. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000004010 · Cited by 2
Kawtharany, H., Azzam, M., Nazzal, J., Hamarsha, Q., Alkhader, A., Khraise, T., Al-Masri, M. M., Zeid, H. K. A., Alwan, I., Alzabibi, M. A., et al. (2026) · Amyloid · doi:10.1080/13506129.2025.2596145 · Cited by 2
Ahmed, A. E., Aljohani, W. F., Moafa, A. K. A., Hattan, F. A., Altalhi, Y., Alsulamy, N. S., Albalawi, Z. M., Aldhubayi, F. M., Alatawi, A. A., & Alqahtani, N. K. (2026) · Cureus · doi:10.7759/cureus.100607 · Cited by 3
“Study quality and risk of bias were assessed using an adapted Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool covering case selection, marker assessment, wound age determination, and flow/timing [17].”
Guo, K., Yon, M. J. Y., Yang, Y., McGrath, C. P. J., & Lam, P. P. Y. (2026) · Journal of Evidence Based Dental Practice · doi:10.1016/j.jebdp.2025.102225 · Cited by 2
Tasevski, S., Treglia, G., Marin, A., Bertagna, F., & Albano, D. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2025.1726567 · Cited by 2
Nair, A. S., Sujir, N., Sen, D., Ahmed, J., Shenoy, N., Shenoy, R., & Mallya, S. M. (2026) · International Dental Journal · doi:10.1016/j.identj.2025.109305 · Cited by 2
“22 In total, 7 articles were included for combined data extraction (3 systematic reviews/ meta-analyses and 4 original research publications).”
Chaudhuri, D., Lazarte, J., Shah, K., Pitre, T., Pekkarinen, P. T., Sendagire, C., Martin, G., Jung, C., Laffey, J. G., Rochwerg, B. N., et al. (2026) · Critical Care Medicine · doi:10.1097/ccm.0000000000007018 · Cited by 2
Yaman, M. E., Khan, F., Al-Lami, B. S., Saeed, A. O., Al-Lami, B., Al-Lami, Y. S., & Yaman, L. E. (2026) · Cureus · doi:10.7759/cureus.101096 · Cited by 3
“Each study was assessed with Quality Assessment of Diagnostic Accuracy Studies 2 tool (QUADAS-2) [10].”
Klopper, G. J., & Adeniyi, O. V. (2026) · Egyptian Journal of Bronchology · doi:10.1186/s43168-026-00515-5 · Cited by 2
“This involved evaluating five domains: Risk of Bias (using QUADAS-2 [62]); Indirect-ness (applicability to PROGRESS-Plus populations [55, 56]); Imprecision (width of CIs); Inconsistency (I²); and Publication Bias (via funnel plots where feasible).”
Sbampato, V., Marco, G. D., Tsoupras, A., Khan, A. A., Beauge, A., Dayer, R., Tabard-Fougère, A., & Ceroni, D. (2026) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2026.108380 · Cited by 4
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.