QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 11,701–11,800 of 14,770
Ghozy, S. A., Jazayeri, S. B., Ali, M. A., Ognard, J., Borkar, R. R., Dmytriw, A. A., Kadirvel, R., Brinjikji, W., & Kallmes, D. F. (2026) · Clinical Radiology · doi:10.1016/j.crad.2026.107402 · Cited by 1
Glassman, I., Fremont, D., Retta, A., Hoar-Stephens, C., Shorr, R., Kline, G. A., Leung, A. A. C., & Hundemer, G. L. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.126.049366 · Cited by 2
Eye-Tracking Technologies for Cognitive Assessment After Acquired Brain Injury: Systematic Review
Calderone, A., Luca, R. D., Corallo, F., Calapai, R., Mirabile, A., Quartarone, A., Nunzio, A. M. D., Casella, C., & Calabrò, R. S. (2026) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/81276 · Cited by 1
“…eye-tracking metrics, we evaluated risk of bias and applicability using Quality Assessment of Diagnostic Accuracy Studies 2 (QUA-DAS-2), which is specifically structured to address concerns in patient selection, index test conduct and interpretation, reference standards, and flow and timing [55].”
Aggarwal, R. V., Shah, N., Wong, J. J. E., & Dajani, Z. (2026) · Infection and Drug Resistance · doi:10.2147/idr.s614240 · Cited by 1
Al‐Ibraheem, A., Ruzzeh, S., Al-Muhtaseb, A., Abdlkadir, A. S., Moghrabi, S., Shi, H., Dadgar, H., Al-Foqahaa, M., Abdulrahman, M., Al-Qasem, S. F., et al. (2026) · Oncology Reviews · doi:10.3389/or.2026.1811291 · Cited by 3
“The risk of bias and quality assessment of the included studies were independently performed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (23).”
All you need to know about conducting a systematic review in cardiovascular research
Carmona, L., & Curbelo, R. (2026) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.26.07023-7 · Cited by 1
Gonzalez, C., Biaggioni, P. A., Matute, R. G., Iocoli, G. A., & Postemsky, P. D. (2026) · Biomass and Bioenergy · doi:10.1016/j.biombioe.2026.109648 · Cited by 1
Barlow, M., Bailey, S., Alessy, S. A., Al‐Bawardy, B., Aldarwesh, S., Bawaked, R. A., Alharith, H., Mahdi, A., Alaklabi, A., Mawardi, M., et al. (2026) · Clinical and Translational Gastroenterology · doi:10.14309/ctg.0000000000001058 · Cited by 2
“Two reviewers independently assessed the risk of bias of each included study using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool (9).”
Martins, O. C., Fernandes, M. V., Milioli, N. J., Baraldo, S., Antunes, V., de Mesquita, C. F., Correa, T. L., da Costa, M. C. P., Martins, M. A. B., & Franco, M. C. (2026) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2026.05.035 · Cited by 2
Case Definitions and Data Sources for NNCSS Parkinson Disease Surveillance: A Systematic Review
Esper, C. D., Hogan, K. N., Abeysekara, P., Smith, K. N., Smith, T. G., & Mercer, S. L. (2026) · JAMA Network Open · doi:10.1001/jamanetworkopen.2026.13928 · Cited by 1
Waisi, T., Crampton, A., & Ansari, M. A. (2026) · IEEE Access · doi:10.1109/access.2026.3701613 · Cited by 1
“Although we considered utilising standardised quality assessment frameworks such as the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) [46] or QUADAS-2 [47], these tools were deemed unsuitable for the specific critical objectives of this review.”
Kobayashi, S., Kamo, T., Ogihara, H., Tamura, S., Kubo, H., Igarashi, T., Saito, H., Kaizu, Y., & Miyata, K. (2026) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2026.2685324 · Cited by 1
Lihui, L., Hu, K., & Zhou, Y. (2026) · Digital Chinese Medicine · doi:10.1016/j.dcmed.2026.05.004 · Cited by 1
Artificial intelligence for postpartum hemorrhage: a systematic review
AlSaad, R., Yazbek, F., Farrell, T., Albasha, S., Al-Marri, A., & Thomas, R. M. (2026) · Frontiers in Global Women s Health · doi:10.3389/fgwh.2026.1806220 · Cited by 1
Visual Electrophysiology for the Diagnosis of Glaucoma
Ou, Y., Chopra, V., Rosdahl, J. A., Richter, G. M., Knight, O. J., Valle, D. S.-D., Takusagawa, H. L., Kim, S. J., & WuDunn, D. (2026) · Ophthalmology · doi:10.1016/j.ophtha.2026.04.014 · Cited by 1
Cella, L., Fasulo, V., Uleri, A., Piccolini, A., Mallia, V., Sormani, F., Finocchiaro, A., Contieri, R., Moretto, S., Avolio, P. P., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-57805-7 · Cited by 2
“Risk of bias was assessed using the QUADAS-2 tool 18 across four domains (patient selection, index test, reference standard, flow/timing).”
Zhu, H.-T., Chen, P.-C., Wang, R.-M., Zeng, Y., Leng, C.-Y., & Li, Z. (2026) · Journal of Evidence Based Dental Practice · doi:10.1016/j.jebdp.2026.102313 · Cited by 1
Innocent, D. C., Anyakorah, P. E., Innocent, R. C., Dozie, I. N. S., Chukwuocha, U. M., & Emerole, C. O. (2026) · BMC Infectious Diseases · doi:10.1186/s12879-026-13784-8 · Cited by 1
“Risk of bias and applicability concerns were assessed using the QUADAS-2 tool, which is recommended for diagnostic accuracy studies [9].”
Qi-Chang, W., Min, K.-Y., Cheng-Yi, W., & Bin, J. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113011 · Cited by 1
Karczewski, D., Karczewski, T., & Olsen, M. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15124690 · Cited by 2
Albahri, M., Kukuk, M., Nensa, F., Lodde, G. C., Livingstone, E., & Schadendorf, D. (2026) · Biomedicines · doi:10.3390/biomedicines14061369 · Cited by 1
Artificial Intelligence, Deep Learning, and Computer Vision in Hysteroscopy: A Systematic Review
Watrowski, R., Sardo, A. D. S., Török, P., Rosati, A., Kostov, S. G., Alkatout, İ., & Vitale, S. G. (2026) · Diagnostics · doi:10.3390/diagnostics16121899 · Cited by 3
A systematic review of artificial intelligence in radiotherapy associated cardiovascular toxicity
Salama, V., Godinich, B. M., Dunham, N., Nguyen, T., Wen, S., Schmidlen, J. A., Cox, W. J., Lilly, P. M., Ryckman, J., Siochi, R. A., et al. (2026) · Cardio-Oncology · doi:10.1186/s40959-026-00528-5 · Cited by 1
“Risk-of-bias for the included imaging-AI studies was evaluated using the Quality assessment of diagnostic accuracy studies (QUA-DAS-2) tool across 11 questions covering 4 domains: patient selection, index test, reference standard, flow, and timing [34, 35].”
Which diagnostic tools and criteria to use for diagnosis of HSPM and MIH? A systematic review
Elfrink, M. E. C., Säbel, N., Lopes, L. B., Garot, E., Cardoso-Martins, I., & Declerck, D. (2026) · European Archives of Paediatric Dentistry · doi:10.1007/s40368-026-01222-x · Cited by 1
Lee, S. A. S., & Glasser, C. (2026) · Journal of Speech Language and Hearing Research · doi:10.1044/2026_jslhr-25-00850 · Cited by 1
Roy, A., Aadithyaraj, K. T., Harti, S. S., Shibna, M. V., & Badwe, Y. R. (2026) · JMIR Research Protocols · doi:10.2196/79580 · Cited by 1
“…studies will be evaluated for relevance (by considering if the psychometric data were reported) and quality by using tools such as COSMIN (Consensus-based Standards for the Selection of Health Measurement Instruments) [10] and QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) [11].”
Farooq, S. M. Y., Yousaf, S., Moazzam, M., Asif, M. F., Niazi, Y., Bilal, S., Tagliati, C., & Gilani, S. A. (2026) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2026.102464 · Cited by 1
Muhammad, Y. U., Sada, A. N., & Mukhtar, U. F. (2026) · FUDMA Journal of Sciences · doi:10.33003/fjs-2026-10(anb-k)-5193 · Cited by 1
Rashid, A. B., Aslam, E., Ashraf, I., Mubeen, T., Mubeen, A., Zakriya, H., & Amjad, M. (2026) · Future Cardiology · doi:10.1080/14796678.2026.2689050 · Cited by 1
Everitt, S., & Scobie, C. (2026) · Veterinary Clinics of North America Small Animal Practice · doi:10.1016/j.cvsm.2026.03.015 · Cited by 1
Abate, G. B., Giampietro, V., Bourke, N., Bennallick, C., Williams, S., & Twumasi, R. (2026) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/cjn.2026.10632 · Cited by 1
Marmo, C., Puca, F. S., McNamara, D. A., Scaldaferri, F., Riccioni, M. E., & Spada, C. (2026) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2026.06.031 · Cited by 1
Mohammed, H. E., Haseeb, M. E., Nasser, M., Hanen, G., Abdelkader, M., Yaser, H., Yaser, S., Samir, A., Arafeh, Y., Wagdy, M., et al. (2026) · Acta Neurologica Belgica · doi:10.1007/s13760-026-03107-8 · Cited by 2
“Eight authors independently assessed studies according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [23], with disagreements resolved by discussion.”
Cord blood biomarkers in infants with neonatal encephalopathy: a systematic review and meta-analysis
Rallis, D., Smolkova, M., Walsh, B. H., Murray, D. M., Christou, H. A., & El‐Dib, M. (2026) · Pediatric Research · doi:10.1038/s41390-026-05209-8 · Cited by 1
Niu, M., & Feng, Y. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1835564 · Cited by 1
Kılınçel, Ş., Bulut, F., Göksel, P., Usta, M. B., & Kılınçel, O. (2026) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2026.1840734 · Cited by 1
PRAME Immunostaining in Acral Melanocytic Proliferations: A Meta-Analysis
Toussaint, A. L., Cárdenas, C. D. S., Fuentes–García, R., Charli-Joseph, Y. V., & Toussaint‐Caire, S. (2026) · American Journal of Dermatopathology · doi:10.1097/dad.0000000000003299 · Cited by 1
Ardila, C. M., Pineda‐Vélez, E., & Díaz-Laclaustra, A. I. (2026) · Head and Neck Pathology · doi:10.1007/s12105-026-01937-9 · Cited by 2
Xia, Q., Li, Q., Ding, C., & Wang, J. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1842330 · Cited by 1
The Accuracy of Statistical Models to Link Serial Crimes: A Meta-Analysis
Kelkar, G. M., Jones, C., & Woodhams, J. (2026) · Journal of Police and Criminal Psychology · doi:10.1007/s11896-026-09828-z · Cited by 1
Jiang, Y.-Z., Wang, R., & Su, T. (2026) · BMC Nephrology · doi:10.1186/s12882-026-05154-y · Cited by 1
de Oliveira, G. M., Zotter, S. F., Tao, B. S., da Silva, A. B. N., mascarenhas, M., Leite, C. B. G., de Almeida, A. P., Mansur, N. S. B., & Medina, G. (2026) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.70478 · Cited by 1
“As there is no widely accepted assessment tool for evaluating the quality of diagnostic assistance provided by AI, we used the QUADAS ‐ 2 tool — the most commonly performed instrument for evaluating the quality of diagnostic trials [58].”
Echeverría, D. A., Arce, J. U., Mora‐Simón, S., Ferasati, M., Rodríguez‐Sánchez, E., Gómez-Marcos, M. Á., García‐Ortiz, L., Maderuelo-Fernández, J. Á., & Lugones‐Sánchez, C. (2026) · Neuropsychology Review · doi:10.1007/s11065-026-09703-y · Cited by 3
Sharma, A. N., Bhagavatula, H., Mapundu, M. T., & Chimusa, E. R. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1803957 · Cited by 2
“Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) reported in Matuszewska et al. (72 – 75) was used for diagnostic accuracy studies (76, 77).”
Girdhar, N., McCreary, D. J., Chan, N., Nedyalkova, A., & Rees, J. (2026) · Pediatric Emergency Care · doi:10.1097/pec.0000000000003653 · Cited by 1
Machine learning-based methods in diagnosing cardiac amyloidosis: a meta-analysis
Song, Y., Wang, Q., Jia, L., & Pei, Y. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1835652 · Cited by 1
“RoB of the included studies was assessed by means of a diagnostic trial evaluation tool, QUADAS-2, which evaluated the RoB and clinical applicability of original diagnostic trials (16).”
Laryngeal Nerve Protection Devices in Thyroid Surgery: A Systematic Review and Evidence Synthesis
Zhang, D., Brucchi, F., Colombo, C., Alesina, P., Donatini, G., Barczyński, M., Randolph, G. W., Llorente, P. M., Vamvakidis, K., Barbieri, D., et al. (2026) · The Laryngoscope · doi:10.1002/lary.70724 · Cited by 1
Evidence-based PET in musculoskeletal infectious and inflammatory diseases
Dondi, F., Zhang-Yin, J. T., Bellini, P., Camoni, L., Rinaldi, R., Viganò, G., Cossandi, M., Passiatore, M., Milano, G., & Bertagna, F. (2026) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.26.03712-x · Cited by 1
Zhang, P., Zhang, B., Liu, N., Huang, D., Zhong, H., Wu, J., Wang, Y., & Ren, Q. (2026) · European Respiratory Review · doi:10.1183/16000617.0299-2025 · Cited by 1
“The latest QUADAS-2 scale [24] was used to assess risk of bias.”
Zeinabadi, M. S., Math, S. Y., Ameli, N., Kocasaraç, H. D., & Pachêco‐Pereira, C. (2026) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2026.07.005 · Cited by 2
Popayán, A. M. E., Parada-Gereda, H. M., & Bernal-Sánchez, J. J. (2026) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2026.104499 · Cited by 1
Paramasamy, J., Leliveld, A., Groen, J.-W., Willems, B. A., Aerts, J. G. J. V., van der Lugt, A., Mulders, T. A., Odink, A. E., & Visser, J. J. (2026) · European Radiology · doi:10.1007/s00330-026-12745-8 · Cited by 1
Seddon, S. M., Godfrey, D., Lo, S. W., Azzi, G., Gondal, F., Beattie, W., & Segal, J. (2026) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izag140 · Cited by 1
Manoj, N., Yip, J., Bridgens, A., Rastogi, A., Siebachmeyer, M., Huttman, M. M., Monsell, F. P., & Gelfer, Y. (2026) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0000000000003400 · Cited by 1
Anderson, C. M., Rausa, V. C., McKinlay, A., Schuster, T., Lloyd, M., Huang, A., Chau, T., Morawakage, T., Anderson, V. A., & Takagi, M. (2026) · Neuropsychology Review · doi:10.1007/s11065-026-09702-z · Cited by 1
Kyriazopoulou, E., Patras, K., Metallidis, S., Gartzonika, K., Akinosoglou, K., Orfanidou, M., Karaiskos, I., Vrioni, G., Giamarellos‐Bourboulis, E. J., & Tsakris, A. (2026) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2026.107937 · Cited by 1
Kashbour, M. O., Amro, S., Nada, E. A., Darwish, M. Y., Hamdy, A. M., & Dizdarevic, S. (2026) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-026-07949-5 · Cited by 1
“Therefore, we assessed methodological quality using QUADAS-2 and QUADAS-C [15, 16 ].”
Su, J., & Zhang, H. (2026) · Frontiers in Pediatrics · doi:10.3389/fped.2026.1834207 · Cited by 1
Yamamoto, N., Shibata, M., Konishi, M., & Tomita, Y. (2026) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000004071 · Cited by 1
Chavez-Ecos, F. A., Quispe‐Vicuña, C., Malaga, M., Pacheco-Barrios, N. V., Huerta‐Rosario, A., Velásquez‐Rimachi, V., Martínez-Esteban, P. C., & Alva-Diaz, C. (2026) · PLoS ONE · doi:10.1371/journal.pone.0345550 · Cited by 1
Wang, Y., Wu, Y., González-Domínguez, N. P., Boruff, J. T., Levis, B., Cuijpers, P. J., Gilbody, S., Harel, D., Ioannidis, J. P. A., Markham, S., et al. (2026) · BMJ · doi:10.1136/bmj-2026-100119 · Cited by 3
“38 No risk of bias tool exists for studies assessing MDCs, and risk of bias for screening accuracy would not necessarily reflect risk of bias for MDCs, so we did not incorporate a risk of bias assessment into our study.”
Autonomous AI for Diabetic Retinopathy Screening: Evidence, Regulation, and Health-System Fit
Mehta, K., Patel, L., & Shah, M. (2026) · Clinical eHealth · doi:10.1016/j.ceh.2026.07.001 · Cited by 1
Nikparast, F., Danesh-Doust, M., & Zare, H. (2026) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2026.112289 · Cited by 1
Mjaess, G., Nicolazzini, M., AMPARORE, D., Bex, A., Campi, R., Cei, F., Noyes, S. L., Re, C., Rosiello, G., Stewart, G. D., et al. (2026) · European Urology · doi:10.1016/j.eururo.2026.07.002 · Cited by 1
Xie, C., Weichang, K., Pi, L., Diaoxin, Q., Yuxuan, Y., Wang, B., & Liang, H. (2026) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.70166 · Cited by 1
“To evaluate the methodological quality and risk of bias of the included models and studies, we applied the Prediction Model Risk of Bias Assessment Tool + AI tool (PROBAST + AI) [ 20 ] and the Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2) [ 21 ], respectively.”
Kessler, D. A., Bobowicz, M., Kosno, M., Joshi, S., Marias, K., Díaz, O., & Lekadir, K. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113101 · Cited by 1
Early Detection Methods for Autism Spectrum Disorder: From Clinical Screening to Multimodal AI
Luo, W., Yin, Z., & Dai, J. (2026) · Diagnostics · doi:10.3390/diagnostics16152376 · Cited by 2
Ng, N., Cabbabe, K., Li, Y., Li, C., Mee, D. Y., & Velaga, J. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113115 · Cited by 1
Tappenden, P., Harnan, S., Hamilton, J. A., Mon-Yee, M., Biz, A. N., Nalbant, G., Pandor, A., Clowes, M., Whyte, S., Thomas, C., et al. (2025) · Health Technology Assessment · doi:10.3310/gjpt1820 · Cited by 1
Ardila, C. M., Vivares‐Builes, A. M., & Pineda‐Vélez, E. (2026) · Caries Research · doi:10.1159/cre/abuag001 · Cited by 1
Matsas, S., PINEDA, A. B., Saowapa, S., Maldonado, A., Llata, C. M., Payne, J. D., Buscemi, D., Farooq, A., Karri, K., & del Giglio, A. (2026) · Asian Pacific Journal of Cancer Prevention · doi:10.31557/apjcp.2026.27.7.2425 · Cited by 1
Liu, Y., Liu, C., Ren, Z., Hu, Y., Wang, C., Chen, C., & Liu, X. (2026) · Radiology Artificial Intelligence · doi:10.1148/ryai.260261 · Cited by 1
Li, X., Wang, L., Tang, T., Chen, Y., Yang, L., Cai, H., Wang, C., Zhang, S., Ding, N., & Liu, K. (2026) · Journal of Medical Internet Research · doi:10.2196/93378 · Cited by 1
“This study used the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [21] and the Prediction Model Risk of Bias Assessment Tool for Artificial Intelligence (PROBAST+AI) tool [22] to conduct quality assessments and risk of bias evaluations for the included studies.”
Khamar, J., Calabrese, E., Shehata, D. G., Elhadi, M., Kapsampelis, P., Sadiq, K. O., Slater, B. J., Florez, I. D., & Kohn, G. P. (2026) · Surgical Endoscopy · doi:10.1007/s00464-026-13229-y · Cited by 1
“For studies evaluating diagnostic accuracy, the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was also applied to systematically appraise potential bias in patient selection, index test conduct, reference standard, and flow and timing [34].”
Artificial intelligence in the radiologic diagnosis of major urological cancers: a meta-analysis
Shen, Y., Peng, L., Gan, L., & Wu, S. (2026) · World Journal of Urology · doi:10.1007/s00345-026-06635-3 · Cited by 1
“The methodological quality of the included studies was assessed using the QUADAS-2 tool [ 15], which evaluates risk of bias and applicability concerns across four domains: patient selection, index test, reference standard, and flow and timing.”
Ardila, C. M., Pineda‐Vélez, E., & Díaz-Laclaustra, A. I. (2026) · Head and Neck Pathology · doi:10.1007/s12105-026-01955-7 · Cited by 1
“Diagnostic accuracy studies were evaluated with Quality Assessment of Diagnostic Accuracy Studies 2 (QUA-DAS-2), considering patient selection, index test, reference standard, and flow and timing [ 19].”
Cunha, M., Nunes, A. F., Miguel, M., Ferreira, D., & Lança, C. (2026) · Ophthalmic and Physiological Optics · doi:10.1007/s44402-026-00145-w · Cited by 1
“The methodological quality and risk of bias for each study were assessed by two reviewers (MC and AN) using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [15].”
Jing, T., Zheng, Q., & Hou, B. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113141 · Cited by 1
Milan, T. B., Pereira, C. G., de Souza, R. P., Schalch, M. S., & Cicco, R. D. (2026) · DNA and Cell Biology · doi:10.1177/10445498261475085 · Cited by 1
Shomurodov, K., Mirkhusanova, R., Cahyanto, A., Хуршидовна, Ш. Г., Abdukhalik-Zade, N., Рашидов, Р. А. Ў., Rafikov, K., & Tuygunov, N. (2026) · Discover Artificial Intelligence · doi:10.1007/s44163-026-01883-z · Cited by 1
Jain, A., Saxena, R., Omhare, A., Fatima, A., Saxena, R., Hashmi, S. Z. A., Singh, K., & Paul, R. (2026) · Cureus · doi:10.7759/cureus.114047 · Cited by 1
Aloufi, B. A., Fulton, R., Willowson, K. P., & Kench, P. L. (2026) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.70166 · Cited by 1
Collins, J. W., Montesi, M., Stoyanov, D. V., Pugh, C. M., Moschovas, M. C., Yu, D., Saikali, S., Levy, J. S., Tandoğdu, Z., Filicori, F., et al. (2026) · npj Digital Surgery · doi:10.1038/s44484-026-00017-3 · Cited by 3
“Diagnostic accuracy studieswereevaluated usingtheQuality AssessmentofDiagnostic Accuracy Studies 2 (QUADAS-2) tool 41 .”
Metabolomic Biomarkers for the Human Diagnosis of Neglected Tropical Diseases: A Systematic Review
Maciel, J. B., Netto, R. L. A., Mwangi, V. I., Fabbri, C., Adrião, A. A. X., Salimo, Z. M., Yakubu, M. N., Gardinassi, L. G., Faccioli, L. H., Koolen, H. H. F., et al. (2026) · Revista da Sociedade Brasileira de Medicina Tropical · doi:10.1590/0037-8682-0298-2025 · Cited by 1
“Methodological quality and risk of bias were assessed using a modified version of the QUADOMICS tool 14 , developed for omics-based studies and derived from the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) framework 15 .”
Das, S., Lam, E., Muhn, O., Mahbub, S., Ansari, D., Osman, H., Awad, R., Al-Ghita, M. K., Thornhill, R. E., Walsh, C., et al. (2026) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.70467 · Cited by 1
Self-citationTian, Z., Sun, X., Zhang, Z., Du, Q., Xu, X., & Zeng, Q. (2026) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2026.117612 · Cited by 1
Procalcitonin for diagnosing infected pancreatic necrosis: a systematic review and meta-analysis
He, T., Zhang, Y., Wen, X., & Zhang, Z. (2026) · BMC Gastroenterology · doi:10.1186/s12876-026-05216-3 · Cited by 1
“Diagnostic accuracy studies in Groups A and B were appraised with QUADAS-2 [16], covering patient selection, index test, reference standard, and flow and timing.”
Validation of the World Falls Guidelines risk stratification algorithm. A systematic review
Pieruccini‐Faria, F., Son, S., Delbaere, K., van der Velde, N., Lord, S. R., Martin, F. C., Ryg, J., Tan, M. P., Liu-Ambrose, T. Y. L., Amaris, D., et al. (2026) · Age and Ageing · doi:10.1093/ageing/afag231 · Cited by 1
“Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) was applied to determine potential risk of bias in the included studies [ 27, 28].”
Jang, J.-H., Lee, G. Y., Chun, J. W., Park, S.-J., Myung, S., & Kong, S. (2026) · Molecular Diagnosis & Therapy · doi:10.1007/s40291-026-00870-5 · Cited by 1
“Risk of bias and applicability concerns were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [15].”
Yadgarov, M. Y., Antonevskaya, T. L., & Likar, Y. (2026) · Pediatric Radiology · doi:10.1007/s00247-026-06760-6 · Cited by 1
“The tool’s developers explicitly state that it “should not be used to generate a summary quality score” [4].”
Yong, X., Li, Z., Wu, Q., & Hu, H. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1885546 · Cited by 1
EDJIMBI, J. A. C., Shah, N. B., Donisi, L., Gajjar, A., See, C., Grimshaw, A. A., Diop, H. B., Ribeiro, A. L. P., Marijon, É., Clifford, G. D., et al. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag130 · Cited by 1
Kızılkurtlu, A. A., & Akpek, A. (2026) · Biosensors · doi:10.3390/bios16080448 · Cited by 1
Lu, F., Wang, L., Zhang, W., Ma, Y., Tian, J., & Hu, Y. (2026) · Journal of Medical Internet Research · doi:10.2196/95648 · Cited by 1
“The methodological quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [27].”
Pillion, M., Kim, P. R., Larsson, M., Jorge, E., Orwa, J., & Gradisar, M. (2026) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2026.102357 · Cited by 1
Ayén, N. S., Rodríguez-Molinero, J., Lorente, P. J. N., Roca, J. A. R., & López‐Jornet, P. (2026) · Clinical Oral Investigations · doi:10.1007/s00784-026-07058-5 · Cited by 1
Makwarela, T. G., Seoraj-Pillai, N., & Nangammbi, T. C. (2026) · Veterinary Research Communications · doi:10.1007/s11259-026-11475-y · Cited by 1
“…JBI checklist for prevalence studies (Munn et al. 2020); JBI checklists for case series/reports; QUADAS-2 for diag - nostic test accuracy studies (Whiting et al. 2011); RoB 2 for randomised trials; ROBINS-I for non-randomised intervention studies (Sterne et al. 2016); SYRCLE for animal…”
Liquid Biopsy in Resected Pancreatic Ductal Adenocarcinoma: A Systematic Review and Meta-Analysis
Qian, J., Ceuppens, S., Tirukkovalur, N. V., He, H.-Z., Zheng, S.-Y., Suppok, R., Koerkamp, B. G., Zureikat, A. H., & Paniccia, A. (2026) · Annals of Surgical Oncology · doi:10.1245/s10434-026-20413-w · Cited by 1
Gaelzer, G. C., Batista, P. K. A., Montenegro, M. V., Silva, R. R. A. D. S., Malik, M., Tebet, M. L. C., Bacca, C. D. O. F., Giorgi, J. M., & Marques, G. L. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag075 · Cited by 1
Guimarães, H. H. D. S. D., & Matos, K. (2026) · International Orthodontics · doi:10.1016/j.ortho.2026.101235 · Cited by 1
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.