QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 11,901–12,000 of 14,770
Visdal, G. H. E., & Christensen, V. L. (2021) · iNSPIRA · doi:10.23865/inspira.v16.3268 · Cited by 1
Hu, X., Li, D., Hu, G., Huang, Q., Wang, P., & Cai, J. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00452-x · Cited by 1
Using INTEGRATE-HTA for the assessment of videorasterstereography in idiopathic scoliosis
Buchberger, B., Wasem, J., & Spiller, L. (2021) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462321000283 · Cited by 1
Chung, M. J., Park, S. W., Kim, S., Cho, C. M., Choi, J., Choi, E. K., Lee, T. H., Cho, E., Lee, J. K., Song, T. J., et al. (2021) · Korean Journal of Gastroenterology · doi:10.4166/kjg.2021.057 · Cited by 1
Ripp, V. O., Berezovskaya, T. P., & Иванов, С. А. (2021) · Digital Diagnostics · doi:10.17816/dd77311 · Cited by 1
Vasilev, Y. A., Panina, O. Y., Grik, E. A., Akhmad, E. S., & Vasileva, Y. N. (2021) · Digital Diagnostics · doi:10.17816/dd70306 · Cited by 1
Park, S. (2021) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2021.10.001 · Cited by 1
Systematic Reviews and Quality Appraisal ofIn VitroCancer Studies: Investigation of Current Practice
Bracher, M., Pilkington, G. J., & Pilkington, K. (2021) · Anticancer Research · doi:10.21873/anticanres.15350 · Cited by 1
Jaafari, O., Gallagher, H. L., Alshehri, M., Hakami, K., & Alshammari, M. (2021) · Reports in Medical Imaging · doi:10.2147/rmi.s331876 · Cited by 1
de Carvalho, C. C., Cardozo, M. M. S., Andrade, R. G., Regueira, S. L. P. A., de Souza, A. B. S., Ramos, I. B., REGO, C. O., Manoel, M. B. S., NETO, A. S., FERRAZ, K. L., et al. (2021) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.23736/s1825-859x.21.00122-5 · Cited by 1
Zhu, Y.-Q., Cui, Y., Duan, Y.-N., Tang, L.-L., Zhu, J., Chen, X., Dong, Y.-X., Liu, W., Tang, W., Guo, Y., et al. (2020) · Radiology of Infectious Diseases · doi:10.4103/rid.rid_7_21 · Cited by 1
Zhao, Y., Morka, N., Simpson, B. S. S., Freeman, A., Kirkham, A. P. S., Kelly, D. M., Whitaker, H. C., Emberton, M., & Norris, J. M. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-052277 · Cited by 1
Nie, G., Peng, D., Li, B., Lu, J., & Xiong, X. (2021) · Frontiers in Genetics · doi:10.3389/fgene.2021.794105 · Cited by 1
Hafizar, H., & Etriyel, M. Y. H. (2021) · Indonesian Journal of Cancer · doi:10.33371/ijoc.v15i4.804 · Cited by 1
Gomes, Y., Chau, M. T., Davies, J., Banwell, H. A., & Causby, R. (2021) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.481 · Cited by 1
Digital Workflows and Material Sciences in Dental Medicine
Joda, T. (2021) · MDPI eBooks · doi:10.3390/books978-3-0365-2586-0 · Cited by 1
Prenatal imaging for the diagnosis of congenital Zika syndrome
Herrera, T. T., Cubilla‐Batista, I., & Goodridge, A. (2022) · Medicine Case Reports and Study Protocols · doi:10.1097/md9.0000000000000183 · Cited by 1
Liu, F., & Ngai, E. W. T. (2022) · American Journal of Health Behavior · doi:10.5993/ajhb.46.1.7 · Cited by 1
Khalid, M. A. (2022) · Community Acquired Infection · doi:10.54844/cai.2021.0014 · Cited by 1
Ojha, S. C., Chen, K., Sun, C., Ahmed, S., Sheng, Y., & Deng, C. (2022) · Infectious Diseases and Therapy · doi:10.1007/s40121-022-00632-w · Cited by 1
Sahib, M. A., Arian, A., Ahmadinejad, N., Bustan, R. A., & Dakhil, H. A. (2022) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-022-00770-8 · Cited by 1
Canakis, A., Bomman, S., Twery, B., Varghese, N. J., Ji, B., Canakis, J. P., & Goldberg, E. M. (2022) · Minerva Gastroenterology · doi:10.23736/s2724-5985.22.03172-2 · Cited by 1
Mattioni, A., Brazzelli, M. G., Cenciarelli, S., Mazzoli, T., Sette, M. D., Gandolfo, C., Marinoni, M., Finocchi, C., Saia, V., Eusebi, P., et al. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010722 · Cited by 1
Grillo‐Ardila, C. F., Torres, M., Gaitán, H., & Zamora, J. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011708 · Cited by 1
Li, W., Wang, J., Li, Y., Yue, Q., Cui, M., & Liu, J. (2022) · Indian Journal of Surgery · doi:10.1007/s12262-022-03475-4 · Cited by 1
El-Ali, A. M., Yametti, G. C., Robbins, G., Lala, S. V., Davis, J. C., & Degnan, A. J. (2022) · Evidence-based imaging · doi:10.1007/978-3-030-38095-3_67-1 · Cited by 1
Artigo de revisão: Uso da ATS na tomada de decisões nas análises clínicas - uma revisão sistemática
Dias, T., & Carvalho, M. O. S. (2022) · Jornal de Assistência Farmacêutica e Farmacoeconomia · doi:10.22563/2525-7323.2020.v5.n2.p.30-39 · Cited by 1
Artificial Intelligence in Oral Health
Lee, J. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-5143-2 · Cited by 1
Howard, E. L., Singleton, M. D., & Soulakvelidze, I. (2022) · Pain Medicine · doi:10.1093/pm/pnac168 · Cited by 1
Westwood, M. E., Ramos, I. C., Armstrong, N., Ryczek, E., Penton, H., Holleman, M. S., Noake, C., & Al, M. (2022) · Health Technology Assessment · doi:10.3310/jtfo0945 · Cited by 2
Self-citationYao, J., Zhang, S., Liang, J., & Li, H. (2022) · Clinical and Translational Imaging · doi:10.1007/s40336-022-00536-2 · Cited by 1
Ultrasonido focalizado de alta intensidad (HIFU) extracorpóreo en tumores sólidos. Actualización
Aguilera-Cobos, L., Baños‐Álvarez, E., Isabel‐Gómez, R., & Blasco‐Amaro, J. A. (2022) · doi:10.52766/jgaj5300 · Cited by 1
Cohort Studies, Meta-analyses, and Clinical Trials in Childhood Hypertension
Larkins, N., & Craig, J. C. (2023) · Springer eBooks · doi:10.1007/978-3-031-06231-5_54 · Cited by 1
Jiang, T., Leng, W., & Zhong, S. (2023) · Laboratory Medicine · doi:10.1093/labmed/lmac151 · Cited by 1
Andriani, R. N., Makkiyyah, S. S., Hertika, A. S. D., Istiono, W., & Hakimi, M. (2022) · JMIR Research Protocols · doi:10.2196/43233 · Cited by 1
Yang, X., Yin, J., Fu, Y., Shen, Y., Zhang, C., Yao, S., Xu, C., Xia, M., Lou, G., Liu, J., et al. (2023) · Diagnostic Pathology · doi:10.1186/s13000-023-01294-z · Cited by 1
Systemic errors in clinical studies / Sistemske napake kliničnih raziskav
Pahor, D. (2021) · Acta Medico-Biotechnica · doi:10.18690/actabiomed.141 · Cited by 1
Garau, L. M., Gregorio, F. D., Nonne, G., Volterrani, D., & Manca, G. (2023) · Clinical and Translational Imaging · doi:10.1007/s40336-023-00552-w · Cited by 1
Novel Serum Biomarkers Associated With Pediatric Hepatic Encephalopathy: A Systematic Review
Krishnan, K., Rao, M., Chang, N., Casazza, M., & Rasmussen, L. (2023) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0000000000003801 · Cited by 1
Tjiayadi, J. B. C., & Theresia, D. J. (2023) · Journal of Advance Research in Medical & Health Science · doi:10.53555/nnmhs.v9i5.1656 · Cited by 1
The Diagnostic Value of Circulating miR-29 Family for Digestive System Malignancies: A Meta-Analysis
Zou, S., Chen, F., Zhang, L., Liu, C., & Chen, H. (2023) · Laboratory Medicine · doi:10.1093/labmed/lmad030 · Cited by 1
Belabbes, M. A., Koutti, L., & Charfi, S. (2022) · IEEE Information Technologies & Smart Industrial Systems (ITSIS) · doi:10.1109/itsis56166.2022.10118381 · Cited by 1
Wissenschaft praktisch – evidenzbasierte Praxis
Ritschl, V., Stamm, T., & Unterhumer, G. (2023) · Studium Pflege, Therapie, Gesundheit · doi:10.1007/978-3-662-66501-5_14 · Cited by 1
Branch-site occlusion sign predicts the embolic origin of acute ischemic stroke: a meta-analysis
Jiang, X. G., Shi, Z., Wang, P., Wang, X., & Liu, F. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1139756 · Cited by 1
Yu, Y., Sun, X., & Zhou, X. (2023) · Indian Journal of Pharmaceutical Sciences · doi:10.36468/pharmaceutical-sciences.spl.694 · Cited by 1
Jazayeri, S. B., Dehghanbanadaki, H., Hosseini, M., Taghipour, P., Bacchus, M. W., Valerio, E. A. D., Sarabchian, E., Balaji, K. C., & Bandyk, M. (2023) · Current Urology · doi:10.1097/cu9.0000000000000214 · Cited by 1
Ahmadzadeh, K., Dizaji, S. R., Balabandian, M., Ramawad, H. A., & Yousefifard, M. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.43.6.585 · Cited by 1
Diagnostic value of BinaxNOW antigen card for Severe Acute Respiratory Syndrome Coronavirus 2
Mai, Y., Zhang, J., Qian, X.-F., Wu, K., Yin, X., Mo, Z.-F., Zhong, X.-Y., Ye, Q.-Q., Yu, Z.-Y., & Guo, X. (2023) · Bioengineered · doi:10.1080/21655979.2023.2180221 · Cited by 1
Guan, Y. (2023) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20220370 · Cited by 3
Kumar, A. (2023) · Springer eBooks · doi:10.1007/978-981-99-2370-0_3 · Cited by 1
Meta analysis of the diagnostic value of circulating miRNA in benign and malignant pulmonary nodules
Hong, Z., Cui, B., Bai, X., Li, H., Cheng, T., Sheng, Y., Lu, Y., Wu, X., Jin, D., Zhao, J., et al. (2023) · World Journal of Surgical Oncology · doi:10.1186/s12957-023-03133-3 · Cited by 1
Phua, S., Hawke, F., Chuter, V., & Tehan, P. E. (2023) · The Journal of Cardiovascular Nursing · doi:10.1097/jcn.0000000000001030 · Cited by 1
Villegas-Coronado, L., López-Navarro, J. M., Chavez-Bermudez, D., Gonzalez-Jimenez, I., Chao-Zhou, L., & Gonzalez-Bojorquez, D. (2023) · Surgery Gastroenterology and Oncology · doi:10.21614/sgo-582 · Cited by 1
However, M. E. T. I. I. T. P. D. A. H. M. R. B. I. D. T. C. H. B. A. B. C.-1., modernisation, T. T., education., I. I. S. T. T. I. A. C. P. O. R., medicine, T. C. W. T. I. R. O. R. I. C., diagnostic, W. R. I. A. B. I. U. A., tools., P. A. M., scans, P. A. A. C. S. (. L. A. T., thus, A. N.-R. T. I. S. I. R. A., picture., R. L. O. F. I. O. T. C., Altogether, et al. (2023) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.13577 · Cited by 1
L’échographie dans la détection de l’enthésite chez l’enfant : revue systématique de la littérature
Rossi‐Semerano, L., Ravagnani, V., Collado, P., Vojinović, J., Roth, J., Magni‐Manzoni, S., Naredo, E., D’Agostino, M. A., & Jousse‐Joulin, S. (2023) · Revue du Rhumatisme · doi:10.1016/j.rhum.2023.10.007 · Cited by 1
Shah, A., Panchal, V. S., Shah, V., Vyas, B., Patel, H., Patel, R., Zala, U., & Chaudhari, J. (2023) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-023-01586-x · Cited by 1
Lv, C.-H., Wu, H., Wan, Q., Shen, C.-X., Zhou, B., Yin, X., & Wang, W. (2023) · Hepatitis Monthly · doi:10.5812/hepatmon-137530 · Cited by 1
Mendes, J. B., Gonsalves, D. A. C., & Campos, A. E. P. (2023) · Brazilian Journal of Health Review · doi:10.34119/bjhrv6n6-180 · Cited by 1
Wynn, M. O., Stephens, M., Pradeep, S., Clarke-Cornwell, A. M., & Bianchi, J. (2023) · International Wound Journal · doi:10.1111/iwj.14519 · Cited by 1
Staibano, P., Um, K. J., Yu, S., Bhandari, M., Gupta, M. K., Au, M., Young, J., & Zhang, H. (2024) · Frontiers in Surgery · doi:10.3389/fsurg.2023.1298611 · Cited by 1
Yadgarov, M. Y., Киреева, Е. Д., Kailash, Dunaykin, M. M., & Likar, Y. N. (2023) · Pediatric Hematology/Oncology and Immunopathology · doi:10.24287/1726-1708-2023-22-4-158-169 · Cited by 1
Meta-Analysis of Diagnostic Value of Heat Shock Protein 90α in Lung Cancer Patients
陈, 晨. (2024) · Advances in Clinical Medicine · doi:10.12677/acm.2024.141077 · Cited by 1
Mistry, J., Walton, D. M., Noblet, T., Bowling, B., Heneghan, N. R., & Rushton, A. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-078392 · Cited by 2
Lever sign test for anterior cruciate ligament injuries: a diagnostic meta-analysis
Hu, S., Wang, X., Wang, Q., & Feng, W. (2024) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-024-04635-w · Cited by 1
Zhao, P., Xu, Y., Xie, C., Zhan, M., Qian, Y., & Gao, Z. (2024) · International Journal of Radiation Research · doi:10.61186/ijrr.22.1.85 · Cited by 1
Solomou, G., Bilyy, A., Tadikonda, P., Gurdas, B., & Pasapula, C. (2024) · The Foot · doi:10.1016/j.foot.2024.102080 · Cited by 1
LIMITED EVIDENCE ON IMAGING FOR DETECTING PROSTATE CANCER: A SYSTEMATIC REVIEW
Abdulloh, A. (2022) · PHARMACOLOGY MEDICAL REPORTS ORTHOPEDIC AND ILLNESS DETAILS (COMORBID) · doi:10.55047/comorbid.v1i4.728 · Cited by 1
Sánchez, E., Verdú, A., Carbonell, A., & Alcázar, J. L. (2024) · Oncology Advances · doi:10.14218/ona.2023.00034 · Cited by 1
Saklani, N. K. (2024) · International Journal of High Dilution Research · doi:10.51910/ijhdr.v23icf.1406 · Cited by 1
Artificial Intelligence in Cutaneous Lesions: Where do we Stand and What is Next?
(2024) · Frontiers research topics · doi:10.3389/978-2-8325-4911-7 · Cited by 2
Qiu, X., Zheng, H., Zhong, F., & Shen, B. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-081458 · Cited by 1
Innovative perspectives on the value of diagnostic tests in clinical practice
Estrada-Orozco, K., & Cuervo-Rojas, J. (2024) · Colombian Journal of Anesthesiology · doi:10.5554/22562087.e1108 · Cited by 1
Yang, S., Yin, W., Shen, H., Chen, T., & Du, H. (2024) · Frontiers in Pharmacology · doi:10.3389/fphar.2024.1371959 · Cited by 1
Planta, C., Bret, C., Manzoni, D., Lhoumeau, A., Mayeur‐Rousse, C., Ticchioni, M., Campos, L., Eischen, A., Gonnet, N., Merle, R., et al. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-081200 · Cited by 1
Gastric cancer detection based on cell‐free DNA in blood: A systematic review and meta‐analysis
Wang, M., Fan, X., Huang, B., Pan, K., Gerhard, M., Mejías‐Luque, R., & Zhang, Y. (2024) · Clinical and Translational Discovery · doi:10.1002/ctd2.329 · Cited by 1
Hogg, R. E., Wickens, R. A., O'Connor, S. R., Gidman, E., Ward, E., Treanor, C., Pető, T., Burton, B., Knox, P. C., Lotery, A. J., et al. (2024) · Health Technology Assessment · doi:10.3310/cyra9912 · Cited by 1
de Oliveira, L. M., Rocha, R. M., Rocha, R. M., Al, B., David, T. M., & de Oliveira, L. M. (2024) · doi:10.29327/2413063.21.1-9 · Cited by 1
ZHAO, M., Pan, Y., Gao, B., LI, Y., HE, Y., ZHANG, P., LI, Y., & WANG, J. (2024) · Translational Cancer Research · doi:10.21037/tcr-24-383 · Cited by 1
“We assessed the quality of the studies included in the diagnostic meta-analysis using the QUADAS-2 tool (21).”
Wijaya, V., Kurniawan, S. D., & Kaisar, M. M. M. (2024) · MethodsX · doi:10.1016/j.mex.2024.102993 · Cited by 1
An evaluation of the preprints produced at the beginning of the 2022 mpox public health emergency
Sterian, M., Samra, A., Pussegoda, K., Corrin, T., Qamar, M., Baumeister, A., Israr, I., & Waddell, L. A. (2024) · Research Integrity and Peer Review · doi:10.1186/s41073-024-00152-w · Cited by 1
“…domains introduce bias: selection of patients, conduct or interpretation of the index test, the reference standard (including its conduct or interpretation), and patient flow and timing (e.g. appropriate intervals between index test and reference standard, all patients included in analysis) [14].”
BackgroundMethodZhu, S., Cao, X., Nabi, G., Zhang, F., Liu, P., Zhang, J., & Guo, C. (2024) · Endoscopy International Open · doi:10.1055/a-2409-5519 · Cited by 1
Wu, X., Zhang, M., Jiang, Q., Li, M., & Wu, Y. (2024) · Expert Review of Anticancer Therapy · doi:10.1080/14737140.2024.2415404 · Cited by 2
“The quality of included studies was evaluated by using the Quality Assessment for Diagnostic Accuracy Studies (QUADAS-2) [17].”
Leal, A. D., Jorge, F. A., Rodrigues-Vendramini, F. A. V., Conrado, P. C. V., Moreira, D. D. C., Pepino, R. D., Capoci, I. R. G., Mendonca, P., Lopes, L. D. G., Bertolini, D. A., et al. (2024) · Current Topics in Medicinal Chemistry · doi:10.2174/0115680266348828241008214528 · Cited by 2
Parenti, S. I., Bartolucci, M. L., Fiordelli, A., Gigola, P., Paganelli, C., & Bonetti, G. A. (2024) · Applied Sciences · doi:10.3390/app142210208 · Cited by 1
Karigowda, L., Gupta, B., Deshpande, K., & Elkady, H. (2024) · Indian Journal of Critical Care Medicine · doi:10.5005/jp-journals-10071-24851 · Cited by 1
de Oliveira, T. S. D., de Santana, M. L. P., Queiroz, V. A. D. O., da Silva, K. B. B., Martins, P. C., Pereira, E. M., & Costa, P. R. D. F. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-086361 · Cited by 1
“Therefore, a revised version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) 13 will be used because it is appropriate for assessing quality and is divided into ‘risk of bias’ and ‘concerns regarding appli-cability’.”
Al‐Dhubaibi, M. S., Bahaj, S. S., Noman, A., Alkassar, W. Y., AbdElneam, A. I., Mohammed, G. F., Nawaz, H., Allana, Z., & Ali, S. S. (2024) · BMC Infectious Diseases · doi:10.1186/s12879-024-10349-5 · Cited by 1
Systematic review and meta-analysis of the ultrasound diagnosis of pelvic organ prolapse (MUDPOP)
García‐Mejido, J. A., Palacín, F. F., & Sainz‐Bueno, J. A. (2025) · Clínica e Investigación en Ginecología y Obstetricia · doi:10.1016/j.gine.2024.101018 · Cited by 1
Cardoso, L. J. C., Ferreira, M. Y., Scherer, R. T., Fukunaga, C. K., Bocanegra‐Becerra, J. E., Günkan, A., Ferreira, C. C., Ellis, J. A., Serulle, Y., & Langer, D. J. (2025) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2025.111081 · Cited by 1
PECORARO, V., Pezzati, P., Fasano, T., & Trenti, T. (2025) · Biochimica Clinica · doi:10.23736/s0393-0564.25.00010-x · Cited by 1
Yu, S., Yan, C., Tang, C., & Liu, Y. (2025) · Journal of International Medical Research · doi:10.1177/03000605241311133 · Cited by 1
Accuracy of Transvaginal Ultrasonography for Staging of Cervical Cancer Patients: A Meta‐Analysis
Ma, G. (2025) · Journal of Clinical Ultrasound · doi:10.1002/jcu.23946 · Cited by 1
“Risk of bias assessment was done using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [19].”
Non-sputum-based triage and confirmatory diagnostic tests for pediatric TB
Drane, A., Molkenthin, A., Gassama, M., Pouzol, S., Vanhems, P., & Hoffmann, J. (2025) · IJTLD OPEN · doi:10.5588/ijtldopen.24.0484 · Cited by 1
“15 Both the Microbiological Reference Standard (MRS) and the Clinical Reference Standard (CRS) were applied to assess confirmatory and triage test performances.”
Mehta, R., Kumar, S., & Sah, R. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.03.045 · Cited by 1
Direct Sampling Mass Spectrometry Analysis for the Assessment of Wounds: A Systematic Review
Pruekprasert, K., Tan, M. K. H., Ford, L., Davies, A. H., Takáts, Z., & Onida, S. (2025) · International Wound Journal · doi:10.1111/iwj.70158 · Cited by 1
New Icebergs in Evidence‐Based Medicine
de Alencar, J. N. (2025) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.70028 · Cited by 1
Head-up tilt testing in older syncope patients: a systematic review
de Ruiter, S. C., van Marum, R. J., RUITER, J. H., Hemels, M. E. W., de Groot, J. R., & Jansen, R. W. M. M. (2025) · Age and Ageing · doi:10.1093/ageing/afaf086 · Cited by 1
“Risk of bias was independently assessed by two investigators with a tailored version of the QUADAS-2 [17], assessing three domains: patient selection, index test and flow and timing.”
SMALL INTESTINAL BACTERIAL OVERGROWTH IN PEOPLE WITH CYSTIC FIBROSIS: SYSTEMATIC REVIEW
Landim, M. L. L., Ribeiro, J. D., Borgli, D. D. S. P., Bonilha, D. Q., Lomazi, E. A., & Servidoni, M. D. F. (2025) · Arquivos de Gastroenterologia · doi:10.1590/s0004-2803.24612024-110 · Cited by 1
“QUADAS-2 assesses the risk of bias in four key domains: patient selection, index test, reference standard, and flow and timing (17) .”
Sensitivity of core needle biopsy in the diagnosis of lymphoma: A meta-analysis
Cottone, C., Kozlowski, K. A., Sorrentino, J., Stahovic, K., Ma, X., Gupta, V., & Afif, A. A. (2025) · Current Problems in Cancer · doi:10.1016/j.currproblcancer.2025.101203 · Cited by 1
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.