QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 11,401–11,500 of 14,770
Jazayeri, S. B., Mehrabinejad, M.-M., Ghozy, S. A., Hamouda, N., Ahmad, B., Kadirvel, R., & Kallmes, D. F. (2025) · Interventional Neuroradiology · doi:10.1177/15910199251345631 · Cited by 2
“” 15 This tool examines bias across four domains: patient selection, index test, reference standard, and fl ow and timing.”
Liquid-Based Cytology in Cervical Cancer Screening: A Systematic Review and Meta-Analysis
Böhmer, G., Stolte, C., Vogelmann, T., Schubert, T., & Ikenberg, H. (2025) · Acta Cytologica · doi:10.1159/000551747 · Cited by 1
Poll, G. H., Brown, B., & Miller, C. (2025) · Journal of Speech Language and Hearing Research · doi:10.1044/2025_jslhr-24-00628 · Cited by 1
Yao, L., Bu, C., & Xiang, L. (2025) · PLoS ONE · doi:10.1371/journal.pone.0325370 · Cited by 1
“The quality of the included literature will be assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [18].”
Harnan, S., Gittus, M., Falzon, L., Durkie, M., Mandrik, O., Ong, A. C. M., & Fotheringham, J. (2025) · Clinical Kidney Journal · doi:10.1093/ckj/sfaf187 · Cited by 2
“Critical appraisal using QUADAS-2 [22 ] was not performed because it is not designed for these studies and would have been uninforma-tive.”
Moore, S., Naragon‐Gainey, K., Pestell, C., Becerra, R., Buelow, M. T., Fynn, D. M., & Weinborn, M. (2025) · Neuropsychology Review · doi:10.1007/s11065-025-09668-4 · Cited by 2
“Risk of bias was calculated using the Quality Assessment of Diagnostic Accuracy Studies 2 criteria (QUADAS-2) (Whiting et al., 2011).”
Pérez‐Pérez, M., de Sola‐Llamas, C. G., & Macías‐García, L. (2025) · Lung Cancer · doi:10.1016/j.lungcan.2025.108623 · Cited by 1
Valizadeh, P., Jannatdoust, P., Shojaei, S., Mousavi, A., & Gholamrezanezhad, A. (2025) · Clinical Imaging · doi:10.1016/j.clinimag.2025.110552 · Cited by 1
Lin, B., Yuan, D., Chen, W., Liu, Y., & Ji, X. (2025) · Journal of International Medical Research · doi:10.1177/03000605251351273 · Cited by 1
Ramya, V., Julius, A., Nisha, V. A., Bhuvaneswarri, J., Rajendran, K. P., & Anbazhagan, R. (2025) · Dental Journal (Majalah Kedokteran Gigi) · doi:10.20473/j.djmkg.v58.i3.p314-324 · Cited by 1
The Importance of Clinical Practice Guidelines
Pereca, J., N’Dow, J., & Omar, M. I. (2025) · Springer eBooks · doi:10.1007/978-3-031-55405-6_1 · Cited by 4
Melzer, Y. F., Erley, J., Ristow, I., Schubert, N., Campbell, G. M., Busse, B., Weisel, K. C., Adam, G., & Molwitz, I. (2025) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-2625-5643 · Cited by 1
“Assessment of study quality and risk of bias to the review question, based on four domains: patient selection , index test, reference standard, and flow and timing [12].”
Providencia, R. A., Aali, G., Zhu, F., Katairo, T., Ahmad, M., Bray, J. J. H., Pelone, F., Marijon, É., Cassandra, M., Celermajer, D. S., et al. (2025) · Communications Medicine · doi:10.1038/s43856-025-01023-1 · Cited by 1
“The methodological quality of the included studies was planned to be assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2)tool 27 .”
Shishesaz, M. I., Eshraghi, R., Bahrami, A., Farzan, M., Farzan, M., Hajibeygi, R., Fathi, M., Yaghoobpoor, S., Tavasol, A., Gorjizad, M., et al. (2025) · Journal of Cardiology · doi:10.1016/j.jjcc.2025.08.002 · Cited by 1
Predicting the histological grade of hepatocellular carcinoma based on dynamic radiomics
Zhang, R., Wang, Y., Li, Z., Shi, Y., Yu, D., Wen, X., Chen, F., Xiao, W., Huang, C., & Feng, Z. (2025) · Asian Journal of Surgery · doi:10.1016/j.asjsur.2025.06.251 · Cited by 1
Zhen, S., Wang, G., Li, X., Yang, J., Yu, J., & Wang, Y. (2025) · Medicine · doi:10.1097/md.0000000000043963 · Cited by 1
Grigore, B., Peters, J., Hamad, W., Calanzani, N., Asare, L., Walter, F. M., & Neal, R. D. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-091435 · Cited by 1
“To assess the risk of bias (RoB), we used the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool 21 ; for comparative accuracy, we also used Quality Assessment of Diagnostic Accuracy Studies-Comparative (QUADAS-C).”
Noto, B., Bobe, C., Brandt, J., Raum, H. N., Nacul, N. G., Riemann, B., & Helfen, A. (2025) · Cancers · doi:10.3390/cancers17162677 · Cited by 1
Chang, L., Shi, H., Zhang, H., Wang, G., Ruan, Z., Li, R., Fu, M., Li, Y., Liu, C., Zeng, D., et al. (2025) · Radiography · doi:10.1016/j.radi.2025.103113 · Cited by 2
Bastardo, R., Pavão, J., Martins, A. I., Silva, A. G., & Rocha, N. P. (2025) · Future Internet · doi:10.3390/fi17080376 · Cited by 1
“…that the analysis of keystroke dynamics presents good accuracy, sensitivity and specificity to discriminate PwP from healthy controls, although the quality of evidence was moderate based on the application of the Quality Assessment of Diagnostic Test Accuracy [137] to the included primary studies.”
Yang, L., Liu, D., Shuang, D., Liang, S., Wang, Y., & Gao, L. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1534173 · Cited by 4
“We used the QUADAS-2 tool to assess the risk of bias in the included studies, as outlined by Whiting et al. (8) and recommended by the Cochrane Diagnostic Test Accuracy Working Group (9).”
Planta, C., Scheffen, L., Jacob, M., Szymanski, G., Chevalier, S., Tondeur, S., Bulabois, B., Meunier, M., Lefebvre, C., Gonnet, N., et al. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-095640 · Cited by 1
Is There a Link Between TSH Levels and Schizophrenia? A Systematic Review and Meta-Analysis
Gatta, E., Dondi, F., Pirola, I., Delbarba, A., Maltese, V., Bellini, P., Ugoccioni, M., Silvestrini, I., Rotondi, M., Bertagna, F., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14175959 · Cited by 1
“The quality assessment of the studies, including the risk of bias and applicability concerns, was carried out using the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) evaluation [14].”
Rajendran, G., Mahalingam, S., Ramkumar, A., Ganessane, E., Krishnamoorthy, Y., Kumaresh, P. T., Vijayan, V., Elanjaeran, R., & Aswin, K. (2025) · Internal and Emergency Medicine · doi:10.1007/s11739-025-04089-w · Cited by 1
“The methodological quality of the included studies was assessed using the QUADAS-2 tool [12].”
Identifying sinonasal inverted papilloma by machine learning: a systematic review and meta-analysis
Qin, X., Shi, J., Zhao, X., Zhang, Y., Liu, X., & Wang, L. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1628999 · Cited by 1
do Carmo, L. H. K., Freitas, M. T. D. C., Colla, R. B., Verdan, S., Bando, T. Y., Andrade, M., Boud'hors, P. D., Cipriano, M., Costa, T. C. D. M., Traina, F., et al. (2025) · Transplantation and Cellular Therapy · doi:10.1016/j.jtct.2025.09.004 · Cited by 2
Prieto-Magallanes, M. L., Barajas, J. D. G., Camarena-Arteaga, V. A., Díaz-Villavicencio, B., Gómez-Fregoso, J. A., Yáñez, A. M. L., Montaño, R. R., Arcos-Jiménez, J. C. D., & Briseño-Ramírez, J. (2025) · Medical Sciences · doi:10.3390/medsci13030175 · Cited by 2
Assessment of suicidal ideation and behavior in community-dwelling older adults: a systematic review
Nieuwenhuijs, B. M., Witte, N. D., & Gorus, E. (2025) · Clinical Gerontologist · doi:10.1080/07317115.2025.2548431 · Cited by 1
“…as measured by the area under the receiver operating characteristics curve (AUC), sensitivity (the ability to correctly detect those with the target condition), and specificity (the ability to correctly exclude those without the target condition) (Bossuyt et al., 2015; Whiting et al., 2011).”
Łajczak, P. M., Nowakowski, P., Jóźwik, K., Żerdziński, K., & Janiec, J. (2025) · European Journal of Ophthalmology · doi:10.1177/11206721251375239 · Cited by 1
“Bias assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool, 7 with results visualized using robvis software.”
Tomosynthesis-only Detected Architectural Distortion: A Meta-analysis of 1361 Lesions
Ferré, R., & Kuzmiak, C. M. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.07.040 · Cited by 1
Serum- and Urine-derived Protein Biomarkers for Prostate Cancer: A Systematic Review Protocol
Okorie, N., Roos, N. A. C., & Nurdin, A. (2025) · Advances in Human Biology · doi:10.4103/aihb.aihb_106_25 · Cited by 1
Machine Learning in Medicine: A New Paradigm for Diagnosis and Treatment
Posunko, A., Chavarha, M., Bashkirova, L., Vasylyuk-Zaitseva, S., & Abramchuk, O. (2025) · Futurity Medicine. · doi:10.57125/fem.2025.09.30.01 · Cited by 1
“Each stage was conducted in accordance with the principles of independence, transparency, and reproducibility [88].”
Identifying acceptable and effective methods of assessing perinatal anxiety: the MAP study
Ayers, S., Meades, R., Sinesi, A., Cheyne, H., Maxwell, M., Best, C. S., Jomeen, J., Walker, J. J., Shakespeare, J., & Alderdice, F. A. (2025) · Health and Social Care Delivery Research · doi:10.3310/rrhd1124 · Cited by 1
Lv, W. (2025) · Frontiers in Medicine · doi:10.3389/fmed.2025.1646417 · Cited by 1
Liu, L., Tao, Y., Zhang, D., Hou, J., Zhou, G., & Tian, M. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1660465 · Cited by 1
Usman, O., Prabakar, D., Malik, M. A., Basit, M. A., Awan, A. R., Khan, M. W., Shahbaz, M. U., Atiq, I., Rajendiran, A., Estrada, P., et al. (2025) · Saudi Journal of Gastroenterology · doi:10.4103/sjg.sjg_140_25 · Cited by 1
Yazd, S. M. M., Vasigh, M., Papazoglou, Α. S., Liatsos, A. C., Ranjbar, K., Williams, A. D., Bleicher, R. J., Katsamenis, O. L., Pierotti, M. L., Pico, C. X. C., et al. (2025) · Frontiers in Medical Engineering · doi:10.3389/fmede.2025.1571528 · Cited by 1
Hajikarimloo, B., Nazari, M. A., Habibi, M. A., Taghipour, P., Alaei, S., Khalaji, A., Hashemi, R., Mohammadzadeh, I., & Tos, S. M. (2025) · BMC Neurology · doi:10.1186/s12883-025-04093-9 · Cited by 1
“The Quality Assessment of Diagnostic Accuracy Stud-ies-2 (QUADAS-2) tool was the primary tool to evaluate the risk of bias (ROB) assessment [26].”
Nie, P.-F., Chen, J., & Li, H.-T. (2025) · Herz · doi:10.1007/s00059-025-05340-y · Cited by 2
Din, N. U., Maronnat, F., Oquendo, B., Pariel, S., Lafuente‐Lafuente, C., Badra, F., & Belmin, J. (2025) · Diagnostics · doi:10.3390/diagnostics15182383 · Cited by 1
“The quality of the included articles was assessed by two authors (NUD, FM) using the Quality Assessment of Diagnostic Accuracy Studies 2 instrument (QUADAS-2) [16] which measures the risk of bias and applicability of diagnostic accuracy studies.”
Advances in clinical neuro-oncology research on integrin PET imaging
Henssen, D. J. H. A., Herings, S. D. A., Sabri, O., Hesse, S., van der Kolk, A. G., Arens, A. I. J., & Gotthardt, M. (2025) · EJNMMI Reports · doi:10.1186/s41824-025-00270-8 · Cited by 1
“The methodological quality of the included articles was assessed using the QUADAS-2 checklist (Whiting et al. 2011).”
Freger, S., Mick, I., Aharoni, S., & Leonardi, M. (2025) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.70021 · Cited by 1
Salimi, M., Abdolizadeh, A., Fayedeh, F., & Vadipour, P. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.09.002 · Cited by 1
Marchand, G. J., Herrera, D. G., Hamilton, B., Robinson, M., Kline, E., Mera, S., Koshaba, M., Jephson, G., Pulicherla, N., & Azadi, A. (2025) · AJOG Global Reports · doi:10.1016/j.xagr.2025.100575 · Cited by 1
Gao, Y., He, C., & Mi, J. (2025) · PeerJ · doi:10.7717/peerj.20074 · Cited by 1
“The quality of the methodology in the included studies was assessed by two researchers (Gao and Mi) independently implementing Review Manager 5.4 and (QUADAS-2) tool ( Whiting et al., 2011 ).”
InfluentialJavadnia, P., Davari, A., Zameni, N., Bahadori, A. R., Ahmadi, S., Mohammadian, S., Tafakhori, A., Shafiee, S., & Ranji, S. (2025) · Neurosurgical Review · doi:10.1007/s10143-025-03841-2 · Cited by 1
Ohannesian, V. A., Falcão, L., Ishizuka, B. M., Menezes, I. R., Han, M. L., Motta, R. F. O. S., Maximiano, M. L. D. B., Cordeiro, D. M. D. H., Baptista, J. M., Mariussi, M., et al. (2025) · Clinical Imaging · doi:10.1016/j.clinimag.2025.110633 · Cited by 1
Role of Radiomics in Parotid Malignant Disease: A Scoping Review
Migliorelli, A., Manuelli, M., Ciorba, A., Stomeo, F., Pelucchi, S., & Bianchini, C. (2025) · Cancers · doi:10.3390/cancers17203284 · Cited by 1
Saibil, S. D., Yao, X., Sivajohanathan, D., Deodat, M., Vickers, M. M., Wheatley‐Price, P., Yoon, J., & Feilotter, H. E. (2025) · Clinical Oncology · doi:10.1016/j.clon.2025.103944 · Cited by 1
Hamed, N. F., Alqahtani, A. M., Alshaibani, F., Elsharif, S. M., Alamri, S. A. S., & Serhan, A. I. (2025) · Cureus · doi:10.7759/cureus.94607 · Cited by 2
Exploration of virtual reality applications in myopia: A systematic review
Ping, X., Kim, J., Yoshioka, N., & Sankaridurg, P. R. (2025) · Advances in Ophthalmology Practice and Research · doi:10.1016/j.aopr.2025.10.002 · Cited by 1
Lu, M., Jiang, D., Zhang, J., Liu, L., Shen, Y., Li, T., Wang, P., Shi, J., Wang, K., & Ye, H. (2025) · Biomarkers in Medicine · doi:10.1080/17520363.2025.2571394 · Cited by 1
Yosif, A. S. F., Blado, G. K. E., Eltayeb, M. A. B., Shamina, N. A., Abdalaziz, M. A. A., & Osman, A. (2025) · Cureus · doi:10.7759/cureus.94852 · Cited by 1
“The quality and risk of bias of the included studies were evaluated using the QUADAS-2 tool [11], which is specifically designed for studies of diagnostic accuracy.”
Ali, A., Khattak, A. I., Chawla, D., Hasan, F. N., Khan, H., Ali, M. A., Moeez, A., Tanveer, S., Ubaidullah, Afridi, M. J., et al. (2025) · Digestive Diseases and Sciences · doi:10.1007/s10620-025-09474-1 · Cited by 2
Liao, W., Grant, R., Lai, F. Y., Aujla, H., Wozniak, M. J., Patel, H. R., Green, L., Mumford, A. D., & Murphy, G. J. (2025) · Transfusion · doi:10.1111/trf.18399 · Cited by 1
Diagnostic value of integrating salivary and blood miRNAs for pancreatic cancer detection
Wilson, P., & NONAKA, T. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1642727 · Cited by 1
Xue, S., Zheng, Y., Cao, Y., Cheung, S. W. H., Chung, C. Y., Zhao, Y., Zhu, X., Lo, I. F. M., Luk, H., Leung, T. Y., et al. (2025) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.70106 · Cited by 1
“Quality assessment and risk-of-bias evaluation for the meta-analysis of PPV was performed by two reviewers independently (S.X. and Y.Z.) using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool 24 .”
Lin, A. H., Hsu, M., Ng, J. K. M., Farahani, S. J., Meçani, R., Nano, J., Li, J. J. X., Vielh, P. R., & Muka, T. (2025) · Diagnostics · doi:10.3390/diagnostics15212675 · Cited by 1
Beladiya, J., Mehta, D., Patel, Y., Patel, S. P., Parmar, D., Dholakia, S. P., Sheth, D. B., Mahalakshmi, B., Patel, C. A., & Boddu, S. H. S. (2025) · Diagnosis · doi:10.1515/dx-2025-0058 · Cited by 8
“Moreover, the sample sizes for IL-1 β and MMP9 were relatively small, limiting the generalizability of our results [73].”
Performance of QuantiFERON tests for detecting latent tuberculosis infections: A Meta-analysis
Weyesa, J. B., Legesse, M., Gumi, B., Medhin, G., Tolossa, K., Zewude, A., & Ameni, G. (2025) · Immunologic Research · doi:10.1007/s12026-025-09714-6 · Cited by 1
Mai, V., Takada, T., Kraaijpoel, N., van Es, N., Mallick, R., Stals, M. A. M., Buller, H. R., Courtney, D. M., Freund, Y., Galipienzo, J., et al. (2025) · Journal of Thrombosis and Haemostasis · doi:10.1016/j.jtha.2025.10.004 · Cited by 1
Kiani, I., Allami, P., Saha, A., Mahmoudzadeh, H., & Dmytriw, A. A. (2025) · Interventional Neuroradiology · doi:10.1177/15910199251389654 · Cited by 1
Lahooti, A., Farahani, S., Stait‐Gardner, T., Deene, Y. D., Moses, D. J., Pham, T. T., & Price, W. S. (2025) · Clinical Imaging · doi:10.1016/j.clinimag.2025.110657 · Cited by 2
Redžepi, S., Burazerović, E., Redžepi, S., Husović, E., & Pojskić, M. (2025) · Brain Sciences · doi:10.3390/brainsci15111188 · Cited by 1
“Risk-of-bias assessment followed the QUADAS-2 guidelines [13].”
Long Non-Coding RNAs in Multiple Sclerosis—Differential Expression and Functional Implications
Misra, K., Nerkar, A., Clarelli, F., Sorosina, M., & Esposito, F. (2025) · Genes · doi:10.3390/genes16111327 · Cited by 1
“Risk of bias across the 51 included studies was assessed using the QUADAS-2 tool, which evaluates four domains: patient selection, index test, reference standard, and flow and timing [13].”
de Alencar, J. N., Lima, G. W. F., Geraldo, H. A. D. S., Fernandes, R. C., Scheffer, M. K., Felicioni, S. P., & Marchi, M. F. N. D. (2025) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20250109 · Cited by 4
Artificial Intelligence in the Diagnosis of Cholesteatoma: A Systematic Review of Current Evidence
Shabi, S. M., Almutairi, L. B., Moafa, A. N., Omer, R. A., Alghamdi, A. M., Alhemaidi, H. S., Alhamyani, H. H., Abualiat, A. A., Alamdi, A. A., Alkhaibari, M. S., et al. (2025) · Cureus · doi:10.7759/cureus.96154 · Cited by 1
“Two reviewers independently assessed risk of bias using QUADAS-2 [9], supplemented with AI-specific considerations from PROBAST-AI (data leakage, validation strategy, transparency) [10].”
Kakada, P., Yuwanati, M. B., & Ramani, P. (2025) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2025.10.023 · Cited by 1
“30 Wells et al. emphasized the diagnostic utility of AI in dermatopathology for vesicular diseases.”
Rubin, D. T., Reinisch, W., Narula, N., Colucci, D. R., Eastman, W., Gottlieb, K. T., Lacerda, A. P., Laroux, F. S., Modesto, I., Navajas, E. E., et al. (2025) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izaf232 · Cited by 1
Accuracy of Clinical Examination in Suspected Pediatric Scaphoid Fractures—A Systematic Review
Lamanna, D. L., Chen, M. X., Livock, H., Sekhon, S., Carsen, S., Smit, K. M., & Cheung, K. (2025) · Plastic Surgery · doi:10.1177/22925503251386747 · Cited by 1
“26 This instrument has been designed to assess the quality of primary diagnostic accuracy studies.”
Tello, A., Vázquez, E., Villamizar, S. J., Mejía‐Salgado, G., Duarte-Bueno, L. M., Acuña, M. F., & Galvis, V. (2025) · European Journal of Ophthalmology · doi:10.1177/11206721251392629 · Cited by 1
Diagnostic accuracy of anti-integrin αvβ6 in ulcerative colitis: a diagnostic meta-analysis
Nisar, M., Awan, A. R., Ahmad, A., Saleem, H., Ayyazuddin, M., Javed, R., KHAN, A. R., Nadeem, M. A., Malik, M. A., Sohail, A. H., et al. (2025) · Journal of Gastroenterology · doi:10.1007/s00535-025-02319-8 · Cited by 1
“The methodological quality and risk of bias in the included studies were assessed using the QUADAS-2 tool [12].”
The role of 18F-FDG PET/CT in adrenocortical carcinoma: a systematic review
Albano, D., Grisanti, S., Cosentini, D., Laganà, M., Dondi, F., Berruti, A., & Bertagna, F. (2025) · Endocrine Related Cancer · doi:10.1530/erc-25-0356 · Cited by 1
Radiological Differentiation of Pituitary Adenomas From Other Sellar Masses: A Systematic Review
Goyal, R. K., Khaing, I., Madhusuthanan, A. K., ., D., Garg, G., & Anwar, S. (2025) · Cureus · doi:10.7759/cureus.96793 · Cited by 1
“These constraints, reflected in our JBI/QUADAS-2 [17,18] judgments, warrant cautious generalization and underscore the need for harmonized methods in future work.”
InfluentialSupritha, S., Pradhan, A., Kadavigere, R., Dkhar, W., Sukumar, S., Barnes, N. A., & Prabhu, A. (2025) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2025.102140 · Cited by 1
Ardila, C. M., Pineda‐Vélez, E., & Vivares‐Builes, A. M. (2025) · Australian Endodontic Journal · doi:10.1111/aej.70034 · Cited by 1
The diagnostic value of the liquid biopsy in the colon cancer
Mlika, M., Zorgati, M. M., Ismail, I. B., Cheikhrouhou, S., & Dziri, C. (2025) · Future Science OA · doi:10.1080/20565623.2025.2590381 · Cited by 1
“…the true positives (tP), false positives (FP), true negatives (tN), the false negatives (FN) and the informations needed to assess the man-uscripts’ quality. the latter was based on the revised version of the QUADAS-2 [9]. the most pertinent criteria S a y a g u é s J M , e t a l [ 38 ] .”
Tomlinson, E., Holmes, J., Rutjes, A. W., Davenport, C. F., Leeflang, M., Yang, B., Mallett, S., & Whiting, P. F. (2025) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2025.112059 · Cited by 2
Self-citationCriteria for Keratoconus Progression: A Systematic Review of Diagnostic Test Accuracy
Gil, P., d’Almeida, O. C., Cunha, B., Gil, J., Donato, H., Alves, N. R., Rosa, A. M., & Murta, J. (2025) · Cornea · doi:10.1097/ico.0000000000004020 · Cited by 1
Colliander, E., Tupper, S., Kielberg, M. L., Liu, M. L., Almar-Munoz, E., Mayr, A., & Mombiela, R. M. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14228255 · Cited by 1
de Sousa, S. E. M., Monteiro, L. P. B., de Castro, R. F., Junior, L. C. D. L. D., Rodrigues, P. D. A., & Brandão, J. M. D. S. (2025) · Australian Endodontic Journal · doi:10.1111/aej.70035 · Cited by 1
Applicability of Lung Ultrasound During Weaning From Mechanical Ventilation: A Systematic Review
Cordeiro, A. L. L., Santos, G. O., da Silva, J. F., Monteiro, J. P. C. D. S., dos Santos, R. P. C., & Forgiarini, L. A. (2025) · Physiotherapy Research International · doi:10.1002/pri.70128 · Cited by 1
“Two researchers independently evaluated the methodological quality of the studies using the QUADAS‐2 tool (Whiting et al. 2011), a validated method for assessing the risk of bias across various domains, as well as factors that may impact applicability.”
Kim, E. E., Hong, S., Kim, D., & Son, Y. (2025) · The Gerontologist · doi:10.1093/geront/gnaf258 · Cited by 3
Goto, A., Kentaro, I., Hirakawa, T., & Komiya, K. (2025) · Cureus · doi:10.7759/cureus.97616 · Cited by 1
“The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, following Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy [11].”
Liquid biopsy in meningioma: a meta-analysis of diagnostic accuracy across fluid-based biomarkers
Meireles, Y., Heming, C. P., & Aran, V. (2025) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2025.2595698 · Cited by 1
“The quality of each included article was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2) [32] by two independent reviewers, C.P.H. and Y.M.”
Yang, Y., Li, X., Gao, S., & Gao, Y. (2025) · The Gerontologist · doi:10.1093/geront/gnaf277 · Cited by 3
Rejmer, C., Hjärtström, M., Bendahl, P., Dihge, L., Skarping, I. D., Zhang, D., Dustler, M., & Rydén, L. (2025) · Systematic Reviews · doi:10.1186/s13643-025-03005-9 · Cited by 2
“The risk of bias was assessed via the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [25], per the protocol and the Cochrane recommendations at the time of protocol registration.”
Hutson, P. (2025) · International journal of human research and social science studies. · doi:10.55677/ijhrsss/16-2025-vol02i11 · Cited by 1
Memory Function and Huntington’s Disease: A Systematic Review
Guillot, J., Haj, M. E., Verny, C., & Allain, P. (2025) · Neuropsychology Review · doi:10.1007/s11065-025-09679-1 · Cited by 2
Patel, Y., Shah, A., Patel, P. R., Patel, V., Bhut, N., Desai, D. H., Maheta, D., Joshi, D. K., & Agrawal, S. P. (2025) · Cardiology in Review · doi:10.1097/crd.0000000000001085 · Cited by 1
Balot, E., Vandenberghe, S., Langenhove, T. V., Meulenaere, V. D., D’Asseler, Y., & Weehaeghe, D. V. (2025) · Brain Sciences · doi:10.3390/brainsci15121271 · Cited by 2
“Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [20].”
Hulse, J., Swanson, A., O’Donnell, E., & Fraga, G. R. (2025) · Journal of Cutaneous Pathology · doi:10.1111/cup.70026 · Cited by 1
Hajikarimloo, B., Mohammadzadeh, I., Shirzadi, P., Tos, S. M., Ebrahimi, A., Hashemi, R., Najari, D., Ghorbanpouryami, F., Hezaveh, E. B., & Habibi, M. A. (2025) · Discover Oncology · doi:10.1007/s12672-025-04035-4 · Cited by 1
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was applied by two independent reviewers to assess the risk of bias (RoB), and any discrepancies were handled by a third author [24].”
Salivary metabolites for pancreatic cancer diagnosis: a systematic review and meta-analysis
Koopaie, M., Fatahzadeh, M., & Kolahdooz, S. (2025) · BMC Gastroenterology · doi:10.1186/s12876-025-04483-w · Cited by 1
Maguire, B., Prehn, J. H. M., & Burke, J. P. (2025) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaf124 · Cited by 2
Accuracy of deep learning in diagnosis of apnea syndrome: a systematic review and meta-analysis
Saiyitijiang, A., Nai, Z., Gao, Y., & Fan, P. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1663851 · Cited by 1
Ocagli, H., Berti, G., Canova, C., Szekely, S., Piaserico, S., Zingone, F., & Baldi, I. (2025) · Systematic Reviews · doi:10.1186/s13643-025-03010-y · Cited by 1
“Two reviewers (H.O. and G.B.) independently evaluated the risk of bias in each study using the Diagnostic Precision Study Quality Assessment Tool (QUADAS-2) [6] recommended by the Cochrane Collaboration.”
Pituitary tuberculosis in the pediatric population: a systematic review and case report
Gierlotka, A., Sordyl, R., Bielecki, I., & Mandera, M. (2025) · Pituitary · doi:10.1007/s11102-025-01601-5 · Cited by 1
Costantini, I., Breglia, A., Pilav, M., Zanatta, M., Ventura, M. V., & Ricci, G. (2025) · Emergency Care Journal · doi:10.4081/ecj.2025.14233 · Cited by 1
Diagnostic thresholds of cardiorespiratory fitness for identifying cardiometabolic risk in youth
García‐Hermoso, A., Yáñez-Sepúlveda, R., Hormazábal‐Aguayo, I., Muñoz‐Pardeza, J., Almonacid, J. G. H., Ezzatvar, Y., Sánchez‐López, M., & Martínez‐Vizcaíno, V. (2025) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2025.104485 · Cited by 1
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.