QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 11,601–11,700 of 14,770
Verdugo‐Paiva, F., Martins-Pfeifer, C. C., Bhosale, A. S., Urquhart, O., Walsh, T., Balagopal, M., Zakershahrak, M., O’Brien, K. K., Ávila, C., Glick, M., et al. (2026) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2025.12.008 · Cited by 4
Lu, Y., Zhao, D., Han, Y. K., Guo, Y., & Dong, Y. (2026) · Urologic Oncology Seminars and Original Investigations · doi:10.1016/j.urolonc.2026.111049 · Cited by 1
Buitenhuis, M. B., Gane, E. M., Hidding, J. T., de Rooij, J. D., Bramer, W. M., de Bree, R., & Speksnijder, C. M. (2026) · Supportive Care in Cancer · doi:10.1007/s00520-026-10373-y · Cited by 2
Khanagar, S. B., Alharthi, M., Asery, A., Alalweet, M., Aldobiyan, A. F., Alhayf, M. D., & Binobaid, A. (2026) · Frontiers in Dental Medicine · doi:10.3389/fdmed.2026.1783828 · Cited by 1
Yu, L., Zhao, Z., Jacobs, R., EzEldeen, M., & de Llano‐Pérula, M. C. (2026) · Journal of Dentistry · doi:10.1016/j.jdent.2026.106612 · Cited by 2
Diagnostic Accuracy of Cough Frequency Monitors: A Systematic Review and Meta‐Analysis
Rodrigues, A. L. C., Passafaro, L. S. R., dos Santos, D. O., da Silva, M. G., da Costa, N. M. E. P. D. L., Silveira, J. M., Spinou, A., & Gastaldi, A. C. (2026) · Respirology · doi:10.1002/resp.70229 · Cited by 1
Moufarrej, S., Bal, K., Rivero, A., Weintraub, M. R., Haupt, T. L., & Wang, K. H. (2026) · OTO Open · doi:10.1002/oto2.70218 · Cited by 1
“25 The main factors of importance within the QUADAS ‐ 2 checklists are: (1) patient selection, (2) index test, (3) reference standard, and (4) fl ow and timing.”
Hsu, H.-A., Yuh, D.-Y., Guerrero, J. J. G., Li, W.-C., & Chang, T.-H. (2026) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2026.02.019 · Cited by 1
Wang, S., Liu, D., Kang, T., Huang, Y., & Jiang, H. (2026) · Academic Radiology · doi:10.1016/j.acra.2026.02.005 · Cited by 1
Elmakaty, I., Abdo, R., Ouda, A., Elmarasi, M., Elahtem, M., Khamis, Y. A., & Malki, M. I. (2026) · AI · doi:10.3390/ai7030107 · Cited by 1
Du, D., He, S., Qin, J., Wang, H., Gao, L., Chen, M., Li, X., Chen, Z., Luo, F., & Shen, Y. (2026) · Chronic Respiratory Disease · doi:10.1177/14799731261431251 · Cited by 1
Psychometric evidence of digital and online executive function tests: a systematic review
Neves-Teles, T., de Souza, J. B., Zanon, C., & de Almeida, R. M. M. (2026) · International Journal of Testing · doi:10.1080/15305058.2026.2639759 · Cited by 1
“Study quality was assessed by T.N.T. using an adapted version of the QUADAS-II tool (Whiting et al., 2011).”
Mishra, V., Jayant, S., Dash, A., Chaudhary, C., & Babaria, S. S. (2026) · Cureus · doi:10.7759/cureus.105167 · Cited by 1
“Appraisal tools like QUADAS-2 offer a conceptual framework for evaluating bias in studies of diagnostic accuracy that involve AI models [30].”
Westwood, M. E., Emerson, J., Armstrong, N., & Stirk, L. (2025) · Health Technology Assessment · doi:10.3310/gjmw5701 · Cited by 1
Self-citationBarra, F. R., Ohannesian, V. A., Fernandes, J. V. A., Han, M. L., Falcão, L., Pereira, K. D. L. A., & Fagundes, A. F. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112806 · Cited by 1
Alzahrani, N. M., Alzahrani, A., Almutlaq, Z., Alghamdi, A. A., Almukhlifi, Y., Alotaibi, S. A., & Alyami, J. (2026) · Diagnostics · doi:10.3390/diagnostics16060881 · Cited by 1
“A, Z.M.A.) using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [32], which evaluates four domains: patient selection, index test, reference standard, and flow and timing.”
Meng, X., Jin, H., Xu, H. Y., Lu, J., Wang, Z., Yang, D., & Yang, Z. (2026) · British Journal of Radiology · doi:10.1093/bjr/tqag039 · Cited by 1
Barmare, A., Rutz, E., Thuraisingam, S., & Gould, D. J. (2026) · Medicina · doi:10.3390/medicina62030570 · Cited by 1
López, J. M. D., Jiménez, J. M. G., Ramos‐Bossini, A. J. L., Cerezo, M. G., Ortega, F. G., & Navarrete, B. A. (2026) · Discover Oncology · doi:10.1007/s12672-026-04602-3 · Cited by 1
“The risk of bias and methodological quality of each included study were evaluated using the QUADAS-2 tool [18].”
Biomarker tests of progression from tuberculosis infection to disease: a systematic review
Tingley, K., Li, A., MacLean, E. L.-H., Skidmore, B., Maredia, N., Ravikumar, R., Alvarez, G., Matteelli, A., & Sulis, G. (2026) · European Respiratory Review · doi:10.1183/16000617.0151-2025 · Cited by 2
Ganss, C., & Vach, K. (2026) · Caries Research · doi:10.1159/000551765 · Cited by 2
Systematic Review: Imaging‐Based Morphological Criteria for Liver Cirrhosis—A Call to Standardise
Lim, M. C., Quek, J. W. E., Chan, T. W., Teng, M. L. P., Ng, C. H., Gnanavelou, M., Chen, V. L., Fallowfield, J. A., Zhang, H., Noureddin, M., et al. (2026) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.70629 · Cited by 1
“C) using the QUADAS-2 tool specifically on articles pertaining to the assessment of cirrhosis in imaging [26].”
Páez-Castellanos, É. A., Burgos-Cárdenas, Á. J., Gaitán‐Duarte, H., Rubio-Romero, J. A., Vargas-Rodriguez, D. D., & Sanabria-Mora, F. (2026) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.70977 · Cited by 1
Lyman, B., Berman, L., Carr, K., Frank, C., Guenter, P., Kassel, R., Kimble, J., McGinnis, C., Oppedisano, S., Paton, E. A., et al. (2026) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.70080 · Cited by 1
“For validation studies, the Quality Assessment of Diagnostic Accuracy Studies (QUADAS ‐ 2) 16 was used.”
Li, W., Jiang, S., Xie, H., & Tong, L. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1749694 · Cited by 3
“Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (38), which evaluates bias risk across four domains: patient selection, index test, reference standard, and applicability concerns.”
Zhou, Q., Huang, X., Lv, Y., Xiao, Z., Luo, S., Wang, Z., Li, Y., Li, Y., Chen, Q., Yu, Z., et al. (2026) · Journal of Pain Research · doi:10.2147/jpr.s578721 · Cited by 1
Research progress on biomarkers of traumatic brain injury
Shen, X., Cheng, S., Chen, S., Wang, M., Li, T., Xu, W., Zhang, Y., Yuan, P., & Shi, L. (2026) · Animal Models and Experimental Medicine · doi:10.1002/ame2.70173 · Cited by 1
“144,163,167,168 With a serum half-life ranging from 24 to 72 h, NSE exhibits a longer temporal profile compared to S100-β , UCH-L1, and GFAP, 144,146,152 rendering it a more favorable prognostic biomarker for predicting outcomes and monitoring the effects of treatment.”
Thaloengsok, S., Munkong, N., Kengkla, K., & Nabheerong, P. (2026) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-026-03695-9 · Cited by 1
“The risk of bias for each included study was independently assessed by two reviewers (ST, PN) using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool, as recommended by the Cochrane Collaboration [15].”
Neural correlates of rumination in psychiatric disorders: A systematic review of fMRI evidence
Carneiro, A. M., da Silva, V. A., Razza, L. B., Vanderhasselt, M., Brunoni, A. R., & da Silva, P. H. R. (2026) · Behavioural Brain Research · doi:10.1016/j.bbr.2026.116181 · Cited by 1
Guntupalli, Y., Nimmagadda, R., Potluri, V., Majety, S. K., Mangalagiri, T., Yendluri, A., Changela, M., Kakarla, M., Oudit, O., & Hasan, M. (2026) · Digestive Diseases · doi:10.1159/000551806 · Cited by 1
“Risk of bias was assessed using the QUADAS-2 tool [13].”
Cui, J., Zheng, W.-Q., Porcel, J. M., Hu, Z.-D., Niu, Y., & Yan, L. (2026) · Revista Clínica Española · doi:10.1016/j.rce.2026.502498 · Cited by 1
Szklarski, Ł. (2026) · Zeszyty Naukowe SGSP · doi:10.5604/01.3001.0055.7099 · Cited by 1
Li, H., Huo, H.-D., Wang, S., & Yang, J. (2026) · BMC Cancer · doi:10.1186/s12885-025-15278-3 · Cited by 1
“Two investigators(HL and HH) assessed the risk of bias and clinical applicability of the included studies respectively, using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [14].”
Ringrose, N. S., Atmaca, Ş., Keil, V. C., & Prysiazhniuk, Y. (2026) · Pediatric Radiology · doi:10.1007/s00247-026-06600-7 · Cited by 1
“Modified quality assessment of diagnostic accuracy studies-2 (QUADAS-2) risk of bias assessments was performed by all authors, with at least two raters evaluating each article [9].”
Mwogosi, A., & Mambile, C. (2026) · Health Policy and Technology · doi:10.1016/j.hlpt.2026.101213 · Cited by 1
Tang, Z., Lei, Y., Huang, J., He, R., Wu, Y., Li, M., Ye, Z., He, X., Heng, H., Zha, Y., et al. (2026) · Journal of Neurology · doi:10.1007/s00415-026-13775-4 · Cited by 1
Rhabdomyosarcoma of the temporal bone in children – a systematic review
Gierlotka, A., Bielecki, I., & Jagosz-Kandziora, E. (2026) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2026.112817 · Cited by 1
Three-Dimensional human motion analysis using LiDAR technology: A systematic review
Lai, J., Yavari, M., Lee, P. V. S., & Ackland, D. C. (2026) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2026.113292 · Cited by 1
Alrefaey, A. I., Воробьева, Е. В., Jubrail, J., Otele, I. M., Lee, M., Sánchez-Elsner, T., Arshad, S. H., Kurukulaaratchy, R. J., & Kyyaly, A. (2026) · Journal of Personalized Medicine · doi:10.3390/jpm16040179 · Cited by 1
Reis, F. A. D., Merique, F. D. A. S., Filho, M. Z., Aldib, R., Almeida, V. M., Alves, D. I., Carvalho, S. N., Lessa, V. C. C., Carneiro, T. S., Caboclo, L. O. S. F., et al. (2026) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2026.105041 · Cited by 1
Dobre, M., Jura, A. M. C., Stroescu, R. F., Popescu, D.-E., & David, V. L. (2026) · Diagnostics · doi:10.3390/diagnostics16081115 · Cited by 1
Sekkat, H., Madkouri, Y., Khallouqi, A., Talbi, M., Mouden, O. E., Halimi, A., Rhazouani, O. E., Merabet, Y. E., & Bentayeb, F. (2026) · Emergency Radiology · doi:10.1007/s10140-026-02465-3 · Cited by 1
Objective methods for monitoring the effectiveness of rehabilitation in ischemic stroke patients
Semenov, V. A., Gromov, A. N., & Gornyi, B. (2026) · Реабилитология. · doi:10.17749/2949-5873/rehabil.2025.51 · Cited by 1
AI unleashed: A meta-analysis transforming radiological insights in diagnosing abdominal infections
Pugliesi, R. A., Papachristodoulou, A., Mansour, K. B., Maalouf, N., Ayed, R. B., & Apitzsch, J. (2026) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2026.111677 · Cited by 1
Baldotto, C. S. D. R., Mascarenhas, E., Gelatti, A. C. Z., Reis, T. V., Corassa, M. P., Teixeira, C. H. A., de Castro, G., & de Lima, V. C. C. (2026) · Clinical Lung Cancer · doi:10.1016/j.cllc.2026.04.001 · Cited by 1
Validad, A., Koozari, A., Abedi, I., & Elhaie, M. (2026) · Indian journal of radiology and imaging - new series/Indian journal of radiology and imaging/Indian Journal of Radiology & Imaging · doi:10.1055/s-0046-1819660 · Cited by 1
Wang, Y., Jiang, Y., Zhang, Y., & Liu, S. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106438 · Cited by 1
Bansal, R. K., Gupta, S., Gupta, S. D., Mittal, S., Kaur, G., Sharma, M. R., & Gupta, S. (2026) · Australian Endodontic Journal · doi:10.1111/aej.70081 · Cited by 1
Hung, Y.-C., Hsieh, P.-F., & Yu, K. (2026) · Lupus · doi:10.1177/09612033261442792 · Cited by 1
Zhao, Y., Zhang, Y., Zhang, J., Chen, C., Li, P., Li, J., & Fu, Q. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1734208 · Cited by 4
Azzam, M., Hamarsha, Q., Kawtharany, H., Nazzal, J., Alkhader, A., Khraise, T., AlMasri, M. M., Zeid, H. K. A., Alwan, I., Jaber, N., et al. (2026) · Blood Advances · doi:10.1182/bloodadvances.2025019530 · Cited by 1
Mihoci, A. M., Socolov, D. G., Mihoci, E. C., Toma, L. M., Pruteanu, A. I., & Socolov, R. V. (2026) · Diagnostics · doi:10.3390/diagnostics16081167 · Cited by 1
Liu, T., Bo, W., Cao, Q. J., Wang, R., Qiao, X., Zhong, Y., Liang, J., Lai, H., & Huang, W. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1709946 · Cited by 1
Hoang, M. T., Chen, Y., Slabaugh, G., & Aung, N. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1770869 · Cited by 1
Nabhan, E. M., Vana, A.-P., Khouri, R., Nehme, E. N., & Poulos, N. (2026) · Cureus · doi:10.7759/cureus.107166 · Cited by 1
“This variability is not random but shows inherent differences in patient selection, consistent with spectrum bias [9].”
InfluentialZhang, Z., Hu, J., Lei, P., Wu, Q., Huang, C., & Zhu, X. (2026) · BMC Medical Imaging · doi:10.1186/s12880-026-02347-7 · Cited by 1
“Methodological rigor was scrutinized using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [35], covering patient selection, the index test, the reference standard, and flow/timing.”
Tieosapjaroen, W., Williams, E., Johnson, C., da Silva, C. B., Barr‐DiChiara, M., Rodolph, M., Ingold, H., Schmidt, H.-M. A., Prochazka, M., Msimanga, B., et al. (2026) · PLoS Medicine · doi:10.1371/journal.pmed.1005030 · Cited by 1
“…In Non-randomised Studies of Interventions, Version 2 (ROBINS-I V2) assessment tool was used to assess bias for non-randomised comparative studies [18], and Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) was used to assess bias for diagnostic accuracy studies (S3 Appendix) [19].”
Guimarães, H. H. D. S. D., & Matos, K. (2026) · Dentistry Review · doi:10.1016/j.dentre.2026.100419 · Cited by 1
Allahqoli, L., Karimzadeh, A., Abadi, A. K., Aghamohammadi, S. Z., Hakimi, S., Rahmani, A., Fallahi, A., Salehiniya, H., Laganà, A. S., Bhagavathula, A. S., et al. (2026) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-026-03462-9 · Cited by 1
“The risk of bias in individual studies was evaluated using the Quality Assessment of Diagnostic Accuracy Stud-ies-2 (QUADAS-2) checklist [29].”
Li, Y., Li, Z., Wang, W., & Li, K. (2026) · Frontiers in Oral Health · doi:10.3389/froh.2026.1811909 · Cited by 1
“We conducted a detailed analysis of the sources of heterogeneity (13, 43).”
InfluentialAlmeida, M., Lucchetta, R. C., Vernal, S., & Graeff-Teixeira, C. (2026) · Revista da Sociedade Brasileira de Medicina Tropical · doi:10.1590/0037-8682-0335-2025 · Cited by 1
“QUADAS-C has the same structure as QUADAS-2 but incorporates additional criteria for the comparison of index tests 17,18 .”
Nirula, S., Gupta, S., & Aldridge, C. (2026) · Skin Health and Disease · doi:10.1093/skinhd/vzag021 · Cited by 1
Bravo-González, A., Domínguez-Ruiz, P., Buitrago-Gonzalez, M. J., Bach, B., Chen, Z., Suarez, D., Arruda, M. P., Lima, R. V., Valle, G. S. D., Zinher, M. T., et al. (2026) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-026-07230-3 · Cited by 2
“Each domain was judged as having low, high, or unclear risk of bias, with applicability concerns assessed in the first three domains [ 14].”
Jia, S., Yin, Y., Wang, C., Liu, S., & Jiang, Y. (2026) · Frontiers in Nutrition · doi:10.3389/fnut.2026.1767700 · Cited by 2
Assessment of Acute Appendicitis in Pregnant Women: A Systematic Review of Current Evidence
Danawar, N. A., Almohamad, M. M., Alkhoms, K. A., Alahmadatea, F. M., Alyasin, R. M., Abdulrasoul, M. A., Alammar, K. M., & AlQusaibi, B. (2026) · Cureus · doi:10.7759/cureus.107410 · Cited by 1
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to objectively evaluate the methodological quality and risk of bias in each included diagnostic accuracy study [12].”
Shah, S. H., Yadav, N. K., VIRANI, A., Priya, P., Rathore, K. B., Dange, K. J., & Warjukar, E. (2026) · Cureus · doi:10.7759/cureus.107560 · Cited by 1
“Diagnostic accuracy studies were evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [22], focusing on domains of patient selection, index test, reference standard, and flow and timing.”
Meethai, C., Phothaworn, P., Nale, J. Y., & Wisessombat, S. (2026) · Veterinary Sciences · doi:10.3390/vetsci13050415 · Cited by 1
Lee, J. Y., Lee, S. H., Ji, Y. G., Jung, H., Koo, J. S., & Park (2026) · Endoscopy International Open · doi:10.1055/a-2863-1407 · Cited by 1
“…were assessed using the Quality Assessment of Diagnostic Studies-2 (QUADAS-2) tool, in accordance with Cochrane Diagnostic Test Accuracy guidelines [8] This tool evaluates risk of bias and concerns regarding applicability across four domains: patient selection, index test, reference standard, and…”
Ahmad, O., Khan, M. I., Omer, M. H., Alzahrani, T., Janjua, M., Echahidi, Z., Kharabsheh, S. M., Tournoux, F., Alsergani, H., Damy, T., et al. (2026) · Open Heart · doi:10.1136/openhrt-2026-004143 · Cited by 2
Bubeníková, A., Fík, Z., Koucký, V., Lazák, J., Peterková, L., Skalický, P., Bradáč, O., & Vlasák, A. (2026) · Neurosurgical Review · doi:10.1007/s10143-026-04293-y · Cited by 1
Diabetic Retinopathy Detection: AI Models and Approaches
Madi, M. M. M., Clarke-Farr, P. C., & Bester, D. J. (2026) · Journal of Ophthalmology · doi:10.1155/joph/8857887 · Cited by 2
Aouf, M., Tamás, L. T., El-Shirbeny, H. A., Abdel-Maboud, M., & Dános, K. (2026) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-026-10227-7 · Cited by 1
Awoke, T., Simieneh, A., Tesfaye, F., Johansen, Ø. H., Vubil, D. C., Yitayew, B., Negash, A. A., & Hanevik, K. (2026) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiag205 · Cited by 1
Image-Based Deep Learning for Cataract Diagnosis: Systematic Review and Meta-Analysis
Li, R., Li, H., Li, C., Li, S., Lei, L., & Tao, D. (2026) · Journal of Medical Internet Research · doi:10.2196/78869 · Cited by 1
Oscillometry for the diagnosis of asthma in children: a systematic review
Seneviratne, S. Y., Law-Gleen, S., Broomfield, J., Divall, P., Devani, P., Ducharme, F. M., & Gaillard, E. A. (2026) · European Respiratory Review · doi:10.1183/16000617.0293-2025 · Cited by 1
“The results of our analysis using the QUADAS-2 tool [29] are summarised in figure 2 with additional details in table S1.”
InfluentialAresta, S., Palmirotta, C., Asim, M., Battista, P., Santi, G. C., Lagravinese, G., Cava, C., Fiore, P., Santamato, A., Vitali, P., et al. (2026) · Brain Sciences · doi:10.3390/brainsci16050468 · Cited by 1
Chen, Y., Song, S., Wang, Z., Guo, Y., Fu, Z., Xu, T., Chen, Y., Jiang, Z., Ding, L., & Xu, Q. (2026) · World Journal of Surgical Oncology · doi:10.1186/s12957-026-04365-9 · Cited by 2
“The risk of bias was evaluated using the QUA-DAS-2 tool within the Review Manager (5.3) software [35].”
InfluentialBouras, M., Pageau, M., Gagnon, M.-A., Costerousse, O., Demers, K., Grenier-Gagnon, A., Isaac, C. J., Torkomyan, T. H., Lauzier, F., Zarychanski, R., et al. (2026) · Critical Care · doi:10.1186/s13054-026-06036-3 · Cited by 2
“We assessed the methodological quality of included studies using a quality assessment scale adapted from the Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) [22] for prognostic studies.”
Evidence-Based Diagnostic and Therapeutic Methods for Thoracic Outlet Syndrome: A Systematic Review
Joshi, A. V., Shinde, S., Chaudhary, N. S., & Chaudhary, S. (2026) · Cureus · doi:10.7759/cureus.108241 · Cited by 1
“Diagnostic reliability was assessed using the QUADAS-2 tool; cross-sectional studies were evaluated using the AXIS tool; and non-randomized interventions were appraised using the ROBINS-I tool [8-10].”
Li, S., Chong, B., Mehri-Kakavand, G., Shi, C., Taylor, D., Fowler, A., Billinghurst, M., Harvey, M., & Wang, A. (2026) · Neurorehabilitation and neural repair · doi:10.1177/15459683261445440 · Cited by 1
“38 RoB judgments were assigned according to the guidance of each respective tool.”
Ebrahimi, R., Fekri, M., Salarvandian, S., Arashlow, F. T., & Noori, S. (2026) · Experimental Gerontology · doi:10.1016/j.exger.2026.113155 · Cited by 1
Alibeiginejad, M. H., Esmaielpour, A., Tsuboi, I., Matsukawa, A., Yanagisawa, T., Mori, K., & Parizi, M. K. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27094130 · Cited by 1
“We assessed the risk of bias of the included studies according to the revised Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) [50].”
Dogra, S., Hu, E., & Kang, S. K. (2026) · American Journal of Roentgenology · doi:10.2214/ajr.26.34673 · Cited by 1
Alzenaidi, A., Alzenaidi, F., Aloraini, A., Alsulaim, K. M., Aloraini, A., Alharbi, T., Alajlan, A., & Alwabli, L. (2026) · Cureus · doi:10.7759/cureus.108163 · Cited by 1
“Three authors independently assessed risk of bias using the Cochrane Revised Risk of Bias Tool for Randomized Trials (Risk of Bias 2, RoB2) and the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) for observational studies [8,9].”
Chung, J. J., Ma, T., Philbrook, P., Zhou, T., Goldman-Yassen, A. E., & Sun, P. Z. (2026) · Tomography · doi:10.3390/tomography12050065 · Cited by 1
Cosmo, L. D., Colella, F. E., Łajczak, P., Schifino, E., Cuervo, S. N., Choueiri, J. E., Centini, F. R., Pellicanò, F., Łajczak, A., Mazzapicchi, E., et al. (2026) · Journal of Neuroradiology · doi:10.1016/j.neurad.2026.101562 · Cited by 1
Early diagnosis of Alzheimer's disease through handwriting analysis and deep learning: A review
Tang, Q., Jiaxi, L., Fan, C., Zhang, X. X., Zhang, C. F., & Qi, H. (2026) · Journal of Alzheimer s Disease · doi:10.1177/13872877261446573 · Cited by 2
Kwon, C., Park, S., & Rafati, A. (2026) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2026.111089 · Cited by 1
Candia-Herrera, D. C., Mojica, K. Y. S., Zarama-Ortiz, S. L., & Diaz-Mesa, C. L. (2026) · Respuestas · doi:10.22463/0122820x.5433 · Cited by 1
Terao, I., & Kodama, W. (2026) · Ageing Research Reviews · doi:10.1016/j.arr.2026.103173 · Cited by 1
Xiang, L., Fang, Y., & Zhanzhan (2026) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-026-03548-4 · Cited by 1
“The quality of diagnostic accuracy studies was assessed using the QUADAS-2 tool, while other study designs were evaluated using the Newcastle-Ottawa Scale (NOS) [29, 30].”
Velur, P., Velur, V., & Gong, M. (2026) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2026.112039 · Cited by 1
Cannoletta, D., Mazzone, E., Bello, F. D., Pecoraro, G., Salfi, G., Tellini, R., Barletta, F. M., Turco, F., Vogl, U., Dell’Oglio, P., et al. (2026) · European Urology Oncology · doi:10.1016/j.euo.2026.04.013 · Cited by 1
Sharma, P., Joshi, N., & Bhandary, S. (2026) · Frontiers in Dental Medicine · doi:10.3389/fdmed.2026.1798996 · Cited by 2
Xie, M., Kim, J. J. Y., Im, J. H. B., Dennett, L., Hareendranathan, A. R., & Jaremko, J. L. (2026) · The Ultrasound Journal · doi:10.5826/tuj.2026.18778 · Cited by 1
“Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool across four domains (patient selection, index test, reference standard, and flow/timing) (21).”
Current role of Histolog® in real-time histopathologic assessment: a systematic review
Liberale, C., Fabbri, V. P., Passaseo, S., Marchioni, D., Corrado, S., Eccher, A., & Mattioli, F. (2026) · Pathologica · doi:10.32074/1591-951x-1864 · Cited by 1
Moura, A. R., Magalhães, M., Santos, C., Marinho, F., Henriques, R., Wimmer, G. E., Dolan, R. J., & Fragata, I. (2026) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2026.106756 · Cited by 1
Automated assessment of 3D facial asymmetry: a systematic review
Peng, J., Qu, W., Zhang, S., & Lin, Y. (2026) · European Journal of Orthodontics · doi:10.1093/ejo/cjag012 · Cited by 1
“The two reviewers assessed the risk of bias and applicability of the included studies independently using a tailored version of the Quality Assessment Tool for Diagnostic Accuracy Studies-2 (QUADAS-2) [12].”
Gierlotka, A., & Bielecki, I. (2026) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2026.112872 · Cited by 1
Puravet, A., Kahouadji, S., Gallot, D., Pereira, B., Bouvier, D., & Sapin, V. (2026) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2026.2665297 · Cited by 1
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.