QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 3,801–3,900 of 14,770
Modi, N., Ashby, D., Battersby, C., Brocklehurst, P., Chivers, Z., Costeloe, K., Draper, E. S., Foster, V., Kemp, J., Majeed, A., et al. (2019) · Programme Grants for Applied Research · doi:10.3310/pgfar07060 · Cited by 39
Wang, K., Li, Z., Wu, Z., Zheng, Y., Zeng, S., Linning, E., & Liang, J. (2019) · Frontiers in Oncology · doi:10.3389/fonc.2019.01229 · Cited by 36
An, Y., Prince, D. S., Gardiner, F. W., Neeman, T. M., Linedale, E., Andrews, J. M., Connor, S. J., & Begun, J. (2019) · The Medical Journal of Australia · doi:10.5694/mja2.50384 · Cited by 38
Comparison of different modalities for the diagnosis of parastomal hernia: a systematic review
de Smet, G. H. J., Lambrichts, D. P. V., van den Hoek, S., Kroese, L. F., Buettner, S., Menon, A. G., Kleinrensink, G., & Lange, J. F. (2020) · International Journal of Colorectal Disease · doi:10.1007/s00384-019-03499-5 · Cited by 38
Liver imaging reporting and data system category M: A systematic review and meta‐analysis
Kim, D. H., Choi, S. H., Park, S. H., Kim, K. W., Byun, J. H., Kim, S. Y., Lee, S. S., Shin, Y. M., Won, H. J., & Kim, P. (2020) · Liver International · doi:10.1111/liv.14420 · Cited by 35
Comparing mortality risk models in VLBW and preterm infants: systematic review and meta-analysis
McLeod, J. S., Menon, A., Matusko, N., Weiner, G. M., Gadepalli, S. K., Barks, J., Mychaliska, G. B., & Perrone, E. E. (2020) · Journal of Perinatology · doi:10.1038/s41372-020-0650-0 · Cited by 41
Measurement of Serum Neuron-Specific Enolase in Neuroblastoma: Is There a Clinical Role?
Ferraro, S., Braga, F., Luksch, R., Terenziani, M., Caruso, S., & Panteghini, M. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa073 · Cited by 39
Meyer, H., Wienke, A., & Surov, A. (2020) · BMC Cancer · doi:10.1186/s12885-020-06942-x · Cited by 43
Umans, D. S., Rangkuti, C. K., Weiland, C. J. S., Timmerhuis, H. C., Bouwense, S. A. W., Fockens, P., Besselink, M. G., Verdonk, R. C., van Hooft, J. E., & for the Dutch Pancreatitis Study Group (2020) · Endoscopy · doi:10.1055/a-1183-3370 · Cited by 35
Pisanu, S., Deledda, A., Loviselli, A., Huybrechts, I., & Velluzzi, F. (2020) · Journal of Nutrition and Metabolism · doi:10.1155/2020/2327017 · Cited by 39
Exhaled volatile organic compounds analysis in clinical pediatrics: a systematic review
Martínez, R. A. S., Pastor, J. M., Yanes, Ó., Díaz, M. C., Puente, T. D. D., & Vinaixa, M. (2020) · Pediatric Research · doi:10.1038/s41390-020-01116-8 · Cited by 40
Vitale, S. G., Carugno, J. A., Riemma, G., Török, P., Cianci, S., FRANCISCIS, P. D., & Parry, J. P. (2020) · Journal of Minimally Invasive Gynecology · doi:10.1016/j.jmig.2020.11.013 · Cited by 35
Zhou, X., Rao, J., Wu, X., Deng, R., & Ma, Y. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.11.013 · Cited by 39
Westwood, M. E., Armstrong, N., Worthy, G., Fayter, D., Ramaekers, B. L. T., Grimm, S. E., Buksnys, T., Ross, J., Mills, N. L., Body, R. M., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa280 · Cited by 38
Self-citationShin, J., Lee, S., Yoon, J. K., Chung, Y. E., Choi, J., & Park, M. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27570 · Cited by 38
Pulse Oximetry as a Diagnostic Tool to Determine Pulp Vitality: A Systematic Review
Almudever-Garcia, A., Forner, L., Sanz, J. L., Llena, C., Rodríguez‐Lozano, F. J., Gironés, J. G., & Melo, M. (2021) · Applied Sciences · doi:10.3390/app11062747 · Cited by 40
Yang, T. Y., Huang, L. T., Malwade, S., Hsu, C., & Chen, Y. (2021) · JMIR mhealth and uhealth · doi:10.2196/26167 · Cited by 40
Więckowski, K., Gallina, T., Surdacki, A., & Chyrchel, B. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10132799 · Cited by 39
Campo, F., Zocchi, J., Moretto, S., Mazzola, F., Petruzzi, G., Donà, M. G., Benevolo, M., Iocca, O., VIRGILIO, A. D., Pichi, B., et al. (2021) · The Laryngoscope · doi:10.1002/lary.29739 · Cited by 35
Li, M., Yuan, Z., & Tang, Z. (2021) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2021.07.010 · Cited by 35
van Gruting, I. M. A., Stankiewicz, A., Thakar, R., Santoro, G. A., IntHout, J., & Sultan, A. H. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011482.pub2 · Cited by 50
Aminlari, A., Stone, J. C., McKee, R. M., Subramony, R., Nadolski, A., Tolia, V. M., & Hayden, S. R. (2021) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2021.09.008 · Cited by 35
Assessing knee functionality: Systematic review of validated outcome measures
Chamorro-Moriana, G., Pérez‐Cabezas, V., Espuny-Ruiz, F., Enamorado, D. T., & Ridao-Fernández, C. (2022) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2021.101608 · Cited by 37
Lee, A., & Park, J. K. (2021) · Clinical Nursing Research · doi:10.1177/10547738211065105 · Cited by 38
Yimam, Y., Mohebali, M., & Afshar, M. J. A. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263770 · Cited by 38
Waqar, M., Roncaroli, F., Lehrer, E. J., Palmer, J. D., Villanueva-Meyer, J. E., Braunstein, S. E., Hall, E., Aznar, M. C., Hamer, P. C. D. W., D’Urso, P. I., et al. (2022) · Neuro-Oncology Advances · doi:10.1093/noajnl/vdac075 · Cited by 39
Performance of Antigen Detection Tests for SARS-CoV-2: A Systematic Review and Meta-Analysis
Tapari, A., Braliou, G. G., Papaefthimiou, M., Mavriki, H., Kontou, P. I., Nikolopoulos, G. K., & Bagos, P. G. (2022) · Diagnostics · doi:10.3390/diagnostics12061388 · Cited by 38
Sánchez-Luquez, K., Carpena, M. X., Karam, S. D. M., & Tovo‐Rodrigues, L. (2022) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2022.108428 · Cited by 37
Xie, J., He, Y., Zheng, Y., Wang, M., Lin, Y., & Lin, L. (2022) · Microbiological Research · doi:10.1016/j.micres.2022.127185 · Cited by 38
Association of thyroid dysfunction and COVID-19: A systematic review and meta-analysis
Darvishi, M., Nazer, M. R., Shahali, H., & Nouri, M. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.947594 · Cited by 35
Maamari, J., Grach, S. L., Passerini, M., Kinzelman-Vesely, E. A., Nassr, A. N., Carr, C. M., Diehn, F. E., Tande, A. J., Murad, M. H., & Berbari, E. F. (2023) · The Spine Journal · doi:10.1016/j.spinee.2023.01.019 · Cited by 36
Quak, E., Cavarec, M., Ciappuccini, R., Girault, G., Rouzier, R., & Lequesne, J. (2023) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.23.03512-4 · Cited by 35
Bjerager, J., Schneider, M., Potapenko, I. O., van Dijk, E. H. C., Faber, C., Grauslund, J., Pfau, K., Huemer, J. C., Muttuvelu, D. V., Rasmussen, M. L. R., et al. (2023) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2022.6396 · Cited by 37
Lutz, C. S., Hasan, A. Z., Bolotin, S., Crowcroft, N. S., Cutts, F. T., Joh, E., Loisate, S., Moss, W. J., Osman, S., & Hayford, K. T. (2023) · BMC Infectious Diseases · doi:10.1186/s12879-023-08199-8 · Cited by 38
Sentinel lymph node detection in early-stage ovarian cancer: a systematic review and meta-analysis
Agustí, N., Viveros-Carreño, D. A., Grillo‐Ardila, C. F., Izquierdo, N., Paredes, P., Vidal‐Sicart, S., Torné, A., & Díaz‐Feijoó, B. (2023) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-2023-004572 · Cited by 37
Wei, Q., Tan, N., Xiong, S., Luo, W., Xia, H., & Luo, B. (2023) · Cancers · doi:10.3390/cancers15235701 · Cited by 40
Protocol for conducting a systematic review on diagnostic accuracy in clinical research
Sguanci, M. E., Mancin, S., Piredda, M., & Marinis, M. G. D. (2024) · MethodsX · doi:10.1016/j.mex.2024.102569 · Cited by 38
Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.
Schwieterman, B., Haas, D., Columber, K., Knupp, D., & Cook, C. E. (2013) · Europe PMC (PubMed Central) · Cited by 35
Song, C., Cui, Z., Li, Y., & Hu, Z. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.00560-14 · Cited by 35
Chen, J., Wu, M., Liu, R., Li, S., Gao, R., & Song, B. (2015) · PLoS ONE · doi:10.1371/journal.pone.0117661 · Cited by 37
Wilson, C., Kerr, D., Noel-Storr, A., & Quinn, T. J. (2015) · International Journal of Geriatric Psychiatry · doi:10.1002/gps.4283 · Cited by 35
Cai, Q., Wu, Y., Guo, Z., Gong, R., Tang, Y., Yang, K., Li, X., Guo, X., Niu, Y., & Zhao, Y. (2015) · Oncotarget · doi:10.18632/oncotarget.6061 · Cited by 36
Ng, S. M., Agwu, J. C., & Dwan, K. (2016) · Archives of Disease in Childhood · doi:10.1136/archdischild-2015-308925 · Cited by 36
Teng, L., Su, X., Jiang, X., Xu, X., Wang, W., Teng, X., & Shao, A. (2016) · OncoTargets and Therapy · doi:10.2147/ott.s101800 · Cited by 35
Arimoto, J., Horita, N., Kato, S., Fuyuki, A., Higurashi, T., Ohkubo, H., Endo, H., Takashi, N., Kaneko, T., & Nakajima, A. (2016) · Scientific Reports · doi:10.1038/srep29754 · Cited by 38
Canovi, S., & Campioli, D. (2016) · Diagnostic Cytopathology · doi:10.1002/dc.23539 · Cited by 35
Freeman, K., Connock, M. J., Auguste, P., Taylor‐Phillips, S., Mistry, H., Shyangdan, D., Court, R. A., Arasaradnam, R. P., Sutcliffe, P. A., & Clarke, A. (2016) · Health Technology Assessment · doi:10.3310/hta20830 · Cited by 35
Albasri, A., O’Sullivan, J. W., Roberts, N. W., Prinjha, S., McManus, R. J., & Sheppard, J. P. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001443 · Cited by 35
Diagnostic performance of PET in thyroid cancer with elevated anti-Tg Ab
Kim, S., Lee, S., Pak, K., & Shim, S. R. (2018) · Endocrine Related Cancer · doi:10.1530/erc-17-0341 · Cited by 37
The Investigation of Suspected Fracture— a Comparison of Ultrasound With Conventional Imaging
Schmid, G. L., Lippmann, S., Unverzagt, S., Hofmann, C., Deutsch, T., & Frese, T. (2017) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2017.0757 · Cited by 46
Kasalak, Ö., Adams, H. J. A., Jutte, P. C., Overbosch, J., Dierckx, R., Wouthuyzen‐Bakker, M., & Kwee, T. C. (2018) · Skeletal Radiology · doi:10.1007/s00256-018-3006-5 · Cited by 35
Suh, C. H., Yun, S. J., Jin, W., Park, S. Y., Ryu, C., & Lee, S. H. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.19306 · Cited by 36
Sobanski, V., Lemaire-Olivier, A., Giovannelli, J., Dauchet, L., Simon, M., López, B., Yelnik, C., Lambert, M., Hatron, P., HACHULLA, E., et al. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.02457 · Cited by 35
Palma, R. M., Bielsa, S., Esquerda, A., Martínez‐Alonso, M., & Porcel, J. M. (2018) · Archivos de Bronconeumología · doi:10.1016/j.arbr.2018.11.007 · Cited by 35
Wu, S., Zheng, Y., Tian, Z., Chen, M., & Tan, H. (2018) · World Journal of Clinical Cases · doi:10.12998/wjcc.v6.i15.995 · Cited by 35
Arslan, M., Dedic, A., Boersma, E. H., & Dubois, E. A. (2019) · European Heart Journal Acute Cardiovascular Care · doi:10.1177/2048872618819421 · Cited by 35
Kim, J. Y., Suh, Y. J., Han, K., Kim, Y. J., & Choi, B. W. (2019) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2018.11.033 · Cited by 35
Lee, S. H., & Yun, S. J. (2019) · Resuscitation · doi:10.1016/j.resuscitation.2019.03.004 · Cited by 36
Circulating MicroRNA-499 as a Diagnostic Biomarker for Acute Myocardial Infarction: A Meta-analysis
Zhao, J., Yu, H., Yan, P., Zhou, X., Wang, Y., & Yao, Y. (2019) · Disease Markers · doi:10.1155/2019/6121696 · Cited by 38
QUADAS-2 tool for quality assessment in diagnostic meta-analysis
Huang, Q.-X., & Huang, X.-W. (2022) · Annals of Palliative Medicine · doi:10.21037/apm-22-204 · Cited by 35
Orme, M. E., Voreck, A., Aksouh, R., Ramsey-Goldman, R., & Schreurs, M. W. J. (2021) · Autoimmunity Reviews · doi:10.1016/j.autrev.2021.102943 · Cited by 34
Jara‐Palomares, L., van Es, N., Praena‐Fernández, J. M., Gal, G. L., Otten, H.-M., Robin, P., Piccioli, A., Lecumberri, R., Religa, P., Rieu, V., et al. (2019) · Thrombosis Research · doi:10.1016/j.thromres.2019.02.011 · Cited by 34
Self-citationTeunissen, W. H. T., Govaerts, C. W., Kramer, M. C. A., Labrecque, J. A., Smits, M., Dirven, L., & van der Hoorn, A. (2022) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2022.10.026 · Cited by 35
Schlürmann, T., Waschulzik, B., Combs, S. E., Gempt, J., Wiestler, B., Weber, W., & Yakushev, I. Y. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.122.264803 · Cited by 34
Tanwani, R., Danquah, M. O., Butris, N., Saripella, A., Yan, E., Kapoor, P., Englesakis, M. F., Tang‐Wai, D. F., Tartaglia, M. C., He, D., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0291291 · Cited by 37
“We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) for the quality assessment of the included studies [17].”
Cheung, H. H. T., Joynt, G. M., & Lee, A. S. Y. (2023) · International Journal of Surgery · doi:10.1097/js9.0000000000000845 · Cited by 38
Chan, V. W.-K., Cao, L., Wong, M. M. H., Lo, K. K.-H., & Tam, W. (2023) · Current Developments in Nutrition · doi:10.1016/j.cdnut.2023.102061 · Cited by 44
Sadr, S., Rokhshad, R., Daghighi, Y., Golkar, M., Kheybari, F. T., Gorjinejad, F., Kojori, A. M., Rahimirad, P., Shobeiri, P., Mahdian, M., et al. (2023) · Dentomaxillofacial Radiology · doi:10.1093/dmfr/twad001 · Cited by 42
Verloop, C. A., Goos, J. A. C., Bruno, M. J., Quispel, R., van Driel, L. M. J. W., & Hol, L. (2024) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2024.02.003 · Cited by 37
Low-dose CBCT protocols in implant dentistry: a systematic review
Kaaber, L. A., Matzen, L. H., Schropp, L., & Spin‐Neto, R. (2024) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2024.03.013 · Cited by 40
Czerwinski-Alley, N. C., Chithiramohan, T., Subramaniam, H., Beishon, L., & Mukaetova-Ladinska, E. B. (2024) · Journal of Alzheimer s Disease Reports · doi:10.3233/adr-230198 · Cited by 40
Bonomo, R. A., Tamma, P. D., Abrahamian, F. M., Bessesen, M. T., Chow, A. W., Dellinger, E. P., Edwards, M. S., Goldstein, E. J. C., Hayden, M. K., Humphries, R. M., et al. (2024) · Clinical Infectious Diseases · doi:10.1093/cid/ciae348 · Cited by 34
Arun, S., Grosheva, M. N., Kosenko, M. G., Robertus, J. L., Blyuss, O. B., Gabe, R., Munblit, D., & Offman, J. (2025) · npj Precision Oncology · doi:10.1038/s41698-025-00940-7 · Cited by 41
“We modi fi ed the Quality Assessment ofDiagnosticAccuracyStudies2(QUADAS-2)tooltobetterre fl ectspeci fi cs of AI and digital pathology 50 .”
Chen, K.-S., Chan, H.-C., & Chan, C.-M. (2025) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-025-03119-z · Cited by 41
“Given that our review focused on studies evaluating diagnostic test accuracy, we applied the QUADAS-2 tool [14], which is specifically designed to assess risk of bias in diagnostic accuracy studies, covering domains such as patient selection, index test, reference standard, and flow and timing.”
Myocardial Viability: It is Still Alive
Lim, S. P., Ardle, B. A. M., Beanlands, R. S., & Hessian, R. C. (2014) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2014.07.003 · Cited by 39
Jiang, T., Zhai, C., Su, C., Ren, S., & Zhou, C. (2016) · Lung Cancer · doi:10.1016/j.lungcan.2016.06.013 · Cited by 36
Biaoxue, R., Liu, H., Wenlong, G., & Shuanying, Y. (2016) · Oncotarget · doi:10.18632/oncotarget.12982 · Cited by 34
Amylase in drain fluid for the diagnosis of pancreatic leak in post-pancreatic resection
Davidson, T. B.-U., Yaghoobi, M., Davidson, B. R., & Gurusamy, K. S. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012009.pub2 · Cited by 34
Kim, J. R., Suh, C. H., Yoon, H. M., Jung, A. Y., Lee, J. S., Kim, J. H., Lee, J., & Cho, Y. A. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25825 · Cited by 36
Collinge, S., Prendergast, G., Mayers, S. T., Marshall, D., Siddell, P., Neilly, E., Ferrie, C. D., Vadlamani, G., Macmullen‐Price, J., Warren, D., et al. (2017) · Seizure · doi:10.1016/j.seizure.2017.09.024 · Cited by 34
Blood-Based Protein Signatures for Early Detection of Colorectal Cancer: A Systematic Review
Bhardwaj, M., Gies, A., Werner, S., Schrotz‐King, P., & Brenner, H. (2017) · Clinical and Translational Gastroenterology · doi:10.1038/ctg.2017.53 · Cited by 35
Kovács, S., Csiki, Z., Zsóri, K. S., Bereczky, Z., & Shemirani, A. H. (2017) · Platelets · doi:10.1080/09537104.2017.1414175 · Cited by 39
Colonic lesion characterization in inflammatory bowel disease: A systematic review and meta-analysis
Lord, R., Burr, N. E., Mohammed, N., & Subramanian, V. (2018) · World Journal of Gastroenterology · doi:10.3748/wjg.v24.i10.1167 · Cited by 36
Diffusion-weighted imaging for staging chronic kidney disease: a meta-analysis
Liu, H., Zhou, Z., Li, X., Li, C., Wang, R., Zhang, Y., & Niu, G. (2018) · British Journal of Radiology · doi:10.1259/bjr.20170952 · Cited by 34
Ultrasound elastography is useful to distinguish acute and chronic deep vein thrombosis
Mumoli, N., Mastroiacovo, D., Giorgi‐Pierfranceschi, M., Pesavento, R., Mochi, M., Cei, M., Pomero, F., Mazzone, A., Vitale, J., Ageno, W., et al. (2018) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14297 · Cited by 35
The diagnostic value of circulating microRNAs as a biomarker for gastric cancer: A meta‑analysis
Wei, H., Pu, K., Liu, X., Li, B., Zhang, H., Wang, H., Wang, H., Sun, W., & Wang, Y. (2018) · Oncology Reports · doi:10.3892/or.2018.6782 · Cited by 36
Innocenti, T., Ristori, D., Miele, S., & Testa, M. (2018) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2018.08.002 · Cited by 37
Suh, C. H., & Yun, S. J. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.18.20243 · Cited by 34
Li, C., Renz, N., Ojeda‐Thies, C., & Trampuž, A. (2018) · Journal of Bone and Joint Infection · doi:10.7150/jbji.29731 · Cited by 34
Kim, S., Lee, S., Jeong, S. Y., Pak, K., & Kim, K. (2019) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2019.01.051 · Cited by 36
Tang, X., Zhou, J., Luo, F., Han, Y., Zhao, W., Diao, Z.-L., Li, M., Qi, L., & Yang, J. (2019) · Renal Failure · doi:10.1080/0886022x.2019.1617736 · Cited by 34
Bonet, M., Oladapo, O., Souza, J. P., & Gülmezoglu, A. M. (2019) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.15884 · Cited by 41
Stummer, W., Koch, R., Valle, R. D., Roberts, D. W., Sanai, N., Kalkanis, S., Hadjipanayis, C. G., & Molina, E. S. (2019) · Acta Neurochirurgica · doi:10.1007/s00701-019-04007-y · Cited by 35
Anxiety screening tools in people with epilepsy: A systematic review of validated tools
Wang, Z., Luo, Z., Li, S., Luo, Z., & Wang, Z. (2019) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.06.035 · Cited by 38
Li, F., Yang, L., Zhao, Y., Yuan, L., Wang, S., & Mao, Y. (2019) · International Journal of Surgery · doi:10.1016/j.ijsu.2019.10.047 · Cited by 36
Trevisani, V. F. M., Pasoto, S. G., Fernandes, M. L. M. S., Lopes, M. L. L., Fialho, S. C. D. M. S., Pinheiro, A. C., dos Santos, L. C., Appenzeller, S., Fidelix, T., Ribeiro, S. L. E., et al. (2019) · Revista Brasileira de Reumatologia · doi:10.1186/s42358-019-0102-8 · Cited by 40
Chang, W., Peng, F., Meng, S., Xu, J., & Yang, Y. (2020) · BMC Immunology · doi:10.1186/s12865-020-0332-x · Cited by 36
Kim, D. H., Chung, S. R., Choi, S. H., & Kim, K. W. (2020) · European Radiology · doi:10.1007/s00330-020-06875-w · Cited by 34
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria [22] were used to assess the quality of the selected articles.”
Tsakiris, C., Siempis, T., Alexiou, G. Α., Zikou, A. K., Sioka, C., Voulgaris, S., & Argyropoulou, M. I. (2020) · World Neurosurgery · doi:10.1016/j.wneu.2020.07.218 · Cited by 34
Percutaneous Bone Biopsy for Diabetic Foot Osteomyelitis: A Systematic Review and Meta-Analysis
Schechter, M. C., Ali, M. K., Risk, B. B., Singer, A. D., Santamarina, G., Rogers, H., Rajani, R. R., Umpierrez, G. E., Fayfman, M., & Kempker, R. R. (2020) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofaa393 · Cited by 37
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.