QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 3,301–3,400 of 14,770
Artificial Intelligence in Laryngeal Endoscopy: Systematic Review and Meta-Analysis
Żurek, M., Rzepakowska, A., Jasak, K., & Niemczyk, K. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11102752 · Cited by 43
Mohan, B. P., Madhu, D., Reddy, N., Chara, B. S., Khan, S. R., Garg, G., Kassab, L. L., Muthusamy, A. K., Singh, A. D., Chandan, S., et al. (2022) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2022.07.026 · Cited by 42
Kelly, H. A., Jaafar, I., Chung, M. H., Michelow, P. M., Greene, S. A., Strickler, H. D., Xie, X., SCHIFFMAN, M. H., Broutet, N. J. N., Mayaud, P., et al. (2022) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101645 · Cited by 53
Wang, X., Liu, S., Gao, J., Zhang, Y., & Huang, T. (2023) · Critical Care · doi:10.1186/s13054-023-04336-6 · Cited by 43
Shi, J.-T., Chen, N., Xu, J. L., Goyal, H., Wu, Z.-Q., Zhang, J., & Xu, H. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12031206 · Cited by 48
Thriemer, K., Ley, B., Menten, J., Jacobs, J. A., & den Ende, J. V. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081263 · Cited by 42
Screening Tools for Anxiety in People with Multiple Sclerosis
Litster, B., Fiest, K. M., Patten, S. B., Fisk, J. D., Walker, J. R., Graff, L. A., Bolton, J. M., Sareen, J., Marriott, J. J., Berrigan, L. I., et al. (2016) · International Journal of MS Care · doi:10.7224/1537-2073.2016-004 · Cited by 41
Validation of asthma recording in electronic health records: a systematic review
Nissen, F., Quint, J. K., Wilkinson, S., Müllerová, H., Smeeth, L. L., & Douglas, I. (2017) · Clinical Epidemiology · doi:10.2147/clep.s143718 · Cited by 42
Shakoor, D., Kijowski, R., Guermazi, A., Fritz, J. M., Roemer, F. W., Jalali‐Farahani, S., Eng, J., & Demehri, S. (2018) · Radiology · doi:10.1148/radiol.2018181212 · Cited by 48
Pillai, R. N., Konje, J. C., Richardson, M., Tincello, D. G., & Potdar, N. (2018) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2017.10.024 · Cited by 41
Signs and symptoms associated with uterine cancer in pre- and postmenopausal women
Boeckstaens, S., Dewalheyns, S., Heremans, R., Vikram, R., Timmerman, D., den Bosch, T. V., & Verbakel, J. Y. J. (2020) · Heliyon · doi:10.1016/j.heliyon.2020.e05372 · Cited by 41
Jeet, V., Parkinson, B., Song, R., Sharma, R., & Hoyle, M. (2023) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2023.02.006 · Cited by 42
Serrano-Velasco, D., Martín-Vacas, A., Paz-Cortés, M. M., Giovannini, G., Cintora-López, P., & Aragoneses, J. M. (2023) · Frontiers in Pediatrics · doi:10.3389/fped.2023.1213072 · Cited by 41
Anand, R., McLeese, R. H., Busby, J., Stewart, J. E., Clarke, M. J., Man, W. D., & Bradley, J. M. (2023) · European Respiratory Review · doi:10.1183/16000617.0248-2022 · Cited by 41
“We assessed risk of bias of included studies using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool, which is the most appropriate method to assess risk of bias in this type of review [31].”
Feltner, C., Wallace, I., Nowell, S. W., Orr, C. J., Raffa, B. J., Middleton, J. C., Vaughan, J., Baker, C., Chou, R., & Kahwati, L. C. (2024) · JAMA · doi:10.1001/jama.2023.24647 · Cited by 52
Shi, Y., Fan, H., Li, L., Hou, Y., Qian, F., Zhuang, M., Miao, B., & Fei, S. (2024) · World Journal of Surgical Oncology · doi:10.1186/s12957-024-03321-9 · Cited by 43
Alvi, M. A., Kwon, B. K., Hejrati, N., Tetreault, L. A., Evaniew, N., Skelly, A. C., & Fehlings, M. G. (2024) · Global Spine Journal · doi:10.1177/21925682231196514 · Cited by 56
Li, N., Yang, J., Li, X., Shi, Y., & Wang, K. (2024) · PLoS ONE · doi:10.1371/journal.pone.0303421 · Cited by 51
Kargozar, S., & Jadidfard, M. (2024) · BMC Oral Health · doi:10.1186/s12903-024-04564-4 · Cited by 44
Sanguedolce, F., Lauwers, C. N. G., Tedde, A., Basile, G., Chernysheva, D. Y., Uleri, A., Baboudjian, M., Giannarini, G., Panebianco, V., Madonia, M., et al. (2024) · European Urology Oncology · doi:10.1016/j.euo.2024.10.006 · Cited by 42
Ajele, K. W., Idemudia, E. S., & Ugwu, L. E. (2024) · PLoS ONE · doi:10.1371/journal.pone.0297913 · Cited by 41
Karamian, A., & Seifi, A. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14072377 · Cited by 52
“All included studies were evaluated for the potential risk of bias using a revised tool for quality assessment of diagnostic accuracy studies included in the systematic review (QUADAS-2) [30].”
Spittal, M. J., Guo, X. A., Kang, L., Kirtley, O. J., Clapperton, A., Hawton, K. E., Kapur, N., Pirkis, J., & Carter, G. L. (2025) · PLoS Medicine · doi:10.1371/journal.pmed.1004581 · Cited by 50
“Risk of bias was assessed using the second revision of the Quality Assessment of Diagnostic Accuracy Studies instrument (QUADAS 2) [20].”
Su, X., Zhang, Z., Qu, X., Tian, Y., & Zhang, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102144 · Cited by 41
Ultrasound in the Diagnostics of Metaphyseal Forearm Fractures in Children
Katzer, C., Wasem, J., Eckert, K., Ackermann, O., & Buchberger, B. (2015) · Pediatric Emergency Care · doi:10.1097/pec.0000000000000446 · Cited by 41
Detweiler, B., Kollmorgen, L., Umberham, B. A., Hedin, R. J., & Vassar, M. B. (2016) · Anaesthesia · doi:10.1111/anae.13520 · Cited by 44
Eastwood, K., Patterson, C. C., Hunter, A. J., McCance, D. R., Young, I. S., & Holmes, V. A. (2017) · Placenta · doi:10.1016/j.placenta.2017.01.005 · Cited by 42
Wan, B., Wang, S., Tu, M., Wu, B., Han, P., & Xu, H. (2017) · Medicine · doi:10.1097/md.0000000000006333 · Cited by 46
Filho, L. T., Grande, A. J., Colonetti, T., Della, É. S. P., & da Rosa, M. I. (2017) · Pediatric Nephrology · doi:10.1007/s00467-017-3704-6 · Cited by 43
“Items were scored as Blow^ (no bias), Bhigh^ (potential bias), or Bunclear^ [12].”
A systematic review of quantitative burn wound microbiology in the management of burns patients
Halstead, F. D., Lee, K. C., Kwei, J. S.-S., Dretzke, J., Oppenheim, B. A., & Moiemen, N. S. (2017) · Burns · doi:10.1016/j.burns.2017.06.008 · Cited by 50
El-Osta, H. E., Jani, P. P., Mansour, A., Rascoe, P. A., & Jafri, S. H. R. (2018) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201711-863oc · Cited by 41
Mackie, F. L., Hall, M. J., Morris, R. K., & Kilby, M. D. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.05.008 · Cited by 41
Hall, P. S., Mitchell, E., Smith, A. F., Cairns, D. A., Messenger, M. P., Hutchinson, M., Wright, J. M., Vinall‐Collier, K. A., Corps, C., Hamilton, P., et al. (2018) · Health Technology Assessment · doi:10.3310/hta22320 · Cited by 44
Yang, H., Llewellyn, A., Walker, R., Harden, M., Saramago, P., Griffin, S. C., & Simmonds, M. C. (2019) · BMC Medicine · doi:10.1186/s12916-019-1254-4 · Cited by 41
Gonçalves, J. C. N., Macedo, A. C. L., Madeira, K., Bavaresco, D. V., Dondossola, E. R., Grande, A. J., & da Rosa, M. I. (2018) · Diseases of the Colon & Rectum · doi:10.1097/dcr.0000000000001231 · Cited by 41
Diagnostic Performance of Ultrasonography for Detection of Pediatric Elbow Fracture: A Meta-analysis
Lee, S. H., & Yun, S. J. (2019) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2019.03.009 · Cited by 41
Hegi‐Johnson, F., Ruysscher, D. D., Keall, P., Hendriks, L. E. L., Vinogradskiy, Y. Y., Yamamoto, T., Tahir, B., & Kipritidis, J. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.03.010 · Cited by 41
Clinical gestalt to diagnose pneumonia, sinusitis, and pharyngitis: a meta-analysis
Dale, A. P., Marchello, C. S., & Ebell, M. H. (2019) · British Journal of General Practice · doi:10.3399/bjgp19x704297 · Cited by 41
Li, B., Pu, K., Ge, L., & Wu, X. (2019) · Gene · doi:10.1016/j.gene.2019.143993 · Cited by 41
Zhu, X., Zhou, J.-N., Qian, Y., Yang, K., Wen, Q., Zhang, Q.-H., Xia, L., Ge, M., & Sun, C.-X. (2019) · Endocrine Journal · doi:10.1507/endocrj.ej18-0558 · Cited by 41
Marchi, F., Filauro, M., Iandelli, A., Carobbio, A. L. C., Mazzola, F., Santori, G., Parrinello, G., Canevari, F. R., Piazza, C., & Peretti, G. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2019.01571 · Cited by 44
Zhao, J., Huang, Y., Song, Y., Xie, D., Hu, M., Qiu, H., & Chu, J. (2020) · European Radiology · doi:10.1007/s00330-020-06717-9 · Cited by 46
Uchida, G., Nakamura, M., Yamamura, T., Furukawa, K., Kawashima, H., Honda, T., Ishigami, M., & Fujishiro, M. (2020) · Digestive Endoscopy · doi:10.1111/den.13669 · Cited by 44
Verweij, L. P. E., Schuit, A. A., Kerkhoffs, G. M. M. J., Blankevoort, L., van den Bekerom, M. P. J., & van Deurzen, D. F. P. (2020) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2020.04.012 · Cited by 41
Kuiper, J. W. P., Verberne, S. J., Vos, S. J., & van Egmond, P. W. (2020) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000001225 · Cited by 41
Imaging modalities for inguinal hernia diagnosis: a systematic review
Piga, E., Zetner, D. B., Andresen, K., & Rosenberg, J. (2020) · Hernia · doi:10.1007/s10029-020-02189-4 · Cited by 41
Wiercioch, W., Nieuwlaat, R., Akl, E. A., Kunkle, R., Alexander, K. E., Cuker, A. C., Rajasekhar, A., Alonso‐Coello, P., Anderson, D. R., Bates, S. M., et al. (2020) · Blood Advances · doi:10.1182/bloodadvances.2020001768 · Cited by 43
Chakraborty, A. R., Almeida, N. C., Prather, K. Y., O’Neal, C. M., Wells, A. A., Chen, S., & Conner, A. K. (2020) · Epilepsia · doi:10.1111/epi.16637 · Cited by 49
Bae, S., Hong, M.-H., Lee, H.-W., Lee, C.-H., Hong, M., Lee, J., & Lee, D. (2020) · Materials · doi:10.3390/ma13214781 · Cited by 41
Abdel‐Halim, C. N., Rosenberg, T., Dyrvig, A., Høilund‐Carlsen, P. F., Sørensen, J. A., Rohde, M., & Godballe, C. (2021) · Oral Oncology · doi:10.1016/j.oraloncology.2020.105169 · Cited by 41
Bedrikovetski, S., Dudi-Venkata, N. N., Maicas, G., Kroon, H. M., Seow, W., Carneiro, G., Moore, J. W., & Sammour, T. (2021) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2021.102022 · Cited by 41
Xie, K., Qin, Q., Long, Z., Yang, Y., Peng, C., Xi, C., Li, L., Wu, Z., Daria, V., Zhao, Y., et al. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.602887 · Cited by 40
Gao, L., Jiao, T., Feng, Q., & Wang, W. (2021) · Osteoporosis International · doi:10.1007/s00198-021-05887-6 · Cited by 44
Geropoulos, G., Aquilina, J., Kakos, C., Anestiadou, Ε., & Giannis, D. (2021) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0000000000001540 · Cited by 43
Salivary exosomal microRNAs as biomarkers for head and neck cancer detection—a literature review
Faur, C. I., Rotaru, H., Osan, C., Jurj, A. M., Roman, R. C., Moldovan, M. A., Chirilă, M., & Hedesiu, M. C. (2021) · Maxillofacial Plastic and Reconstructive Surgery · doi:10.1186/s40902-021-00303-9 · Cited by 48
Ebrahim, A. H., Dhahi, A., Husain, M. A., & Jahrami, H. (2022) · Sultan Qaboos University medical journal · doi:10.18295/squmj.6.2021.081 · Cited by 66
Zhang, L., Sun, J., Jiang, B., Wang, L., Zhang, Y., & Xie, X. (2021) · European Journal of Hybrid Imaging · doi:10.1186/s41824-021-00107-0 · Cited by 44
Zhou, X., Pan, W., Chen, B., Xu, Z., & Pan, J. (2021) · Annals of Intensive Care · doi:10.1186/s13613-021-00909-2 · Cited by 47
Nassr, A. A., Berghella, V., Hessami, K., Bibbo, C., Bellussi, F., Robinson, J. N., Marsoosi, V., Tabrizi, R., Safari‐Faramani, R., Tolcher, M. C., et al. (2021) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2021.07.031 · Cited by 43
Opportunistic CT screening of osteoporosis on thoracic and lumbar spine: a meta-analysis
Zhu, Y., Triphuridet, N., Yip, R., Becker, B. J., Wang, Y., Yankelevitz, D. F., & Henschke, C. I. (2021) · Clinical Imaging · doi:10.1016/j.clinimag.2021.08.005 · Cited by 44
Voice-Related Quality of Life After Total Laryngectomy: Systematic Review and Meta-Analysis
Maniaci, A., Lechien, J. R., Caruso, S., Nocera, F., Ferlito, S., Iannella, G., Grillo, C., Magliulo, G., Pace, A., Vicini, C., et al. (2021) · Journal of Voice · doi:10.1016/j.jvoice.2021.09.040 · Cited by 41
Xie, F. X., Zhang, K., Li, F., Ma, G., Ni, Y., Zhang, W., Wang, J., & Li, Y. (2021) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2021.12.021 · Cited by 43
Diagnostic accuracy of an artificial intelligence online engine in migraine: A multi‐center study
Cowan, R. P., Rapoport, A. M., Blythe, J., Rothrock, J. F., Knievel, K. L., Peretz, A. M., Ekpo, E., Sanjanwala, B. M., & Woldeamanuel, Y. W. (2022) · Headache The Journal of Head and Face Pain · doi:10.1111/head.14324 · Cited by 44
“The results are reported in accordance with the Standards for Reporting of Diagnostic Accuracy Studies (STARD).”
Artificial Intelligence in Colon Capsule Endoscopy—A Systematic Review
Moen, S., Vuik, F. E. R., Kuipers, E. J., & Spaander, M. C. W. (2022) · Diagnostics · doi:10.3390/diagnostics12081994 · Cited by 44
Evangelista, K., Silva, B. S. D. F., Yamamoto‐Silva, F. P., Valladares‐Neto, J., Silva, M. A. G., Cevidanes, L., Canto, G. D. L., & Massignan, C. (2022) · Clinical Oral Investigations · doi:10.1007/s00784-022-04742-0 · Cited by 46
Dillner, P., Eggenschwiler, L. C., Rutjes, A. W., Berg, L. M., Musy, S. N., Simon, M., Moffa, G., Förberg, U., & Unbeck, M. (2022) · BMJ Quality & Safety · doi:10.1136/bmjqs-2022-015298 · Cited by 48
“This QAT was based on the structure of the Quality Assessment Tool for Diagnostic Accuracy Studies 2 tool 27 and the content of the QAT by Musy et al 28 and later by Eggenschwiler et al 29 (online supplemental material 1, page 14).”
Self-citationAccuracy of serological tests for COVID-19: A systematic review and meta-analysis
Zheng, X., Duan, R. H., Gong, F., Wei, X., Dong, Y., Chen, R., Liang, M. Y., Tang, C., & Lu, L. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.923525 · Cited by 41
Rees, C. A., Lim, J. K., Westbrook, A. L., Helou, R. E., Schmid, A. M., Rubin-Smith, J. E., Shreeve, K. M., Rotman, C., Govindapillai, S., Dorney, K., et al. (2023) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2022-001627 · Cited by 41
Hu, S.-L., Wang, D., Gou, W., Lei, Q.-F., Ma, T., & Cheng, J. (2014) · Journal of Nephrology · doi:10.1007/s40620-014-0042-7 · Cited by 42
Herráiz-Adillo, Á., Cavero‐Redondo, I., Álvarez‐Bueno, C., Martínez‐Vizcaíno, V., Pozuelo‐Carrascosa, D. P., & Notario‐Pacheco, B. (2017) · International Journal of Clinical Practice · doi:10.1111/ijcp.12994 · Cited by 46
Schmid, E. V., Thomschewski, A. C., Taylor, A. C., Zimmermann, G., Kirschner, M., Kobulashvili, T., Brigo, F., Rados, M., Helmstaedter, C., Braun, K. P. J., et al. (2018) · Epilepsia · doi:10.1111/epi.14588 · Cited by 41
Dong, F., Li, M., Jiao, Y., Xu, J.-F., Xiong, Y., Zhang, L., Luo, H., & Ding, Z. (2015) · Medical Ultrasonography · doi:10.11152/mu.2013.2066.172.hyr · Cited by 49
Buchanan-Hughes, A., Bobrowska, A., Visintin, C., Attilakos, G., & Marshall, J. (2020) · Systematic Reviews · doi:10.1186/s13643-020-01355-0 · Cited by 40
Sato, R., Hasegawa, D., Hamahata, N. T., Narala, S., Nishida, K., Takahashi, K., Sempokuya, T., & Daoud, E. G. (2020) · Journal of Critical Care · doi:10.1016/j.jcrc.2020.09.030 · Cited by 40
Kim, S., Choi, E. J., Jung, Y.-S., & Jang, I. (2021) · Journal of Clinical Nursing · doi:10.1111/jocn.16157 · Cited by 42
Variation in detected adverse events using trigger tools: A systematic review and meta-analysis
Eggenschwiler, L. C., Rutjes, A. W., Musy, S. N., Ausserhofer, D., Nielen, N. M., Schwendimann, R., Unbeck, M., & Simon, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0273800 · Cited by 42
“This was inspired by the Quality Assessment Tool for Diagnostic Accuracy Studies 2 (QUADAS-2) tool and by the QAT developed by Musy et al. [41].”
Self-citationXiang, C., Cong, S., Tan, X., Ma, S., Liu, Y., Wang, H., & Cong, S. (2022) · npj Parkinson s Disease · doi:10.1038/s41531-022-00431-7 · Cited by 43
Shear, M. A., Swanson, K., Garg, R., Jelin, A. C., Boscardin, W. J., Norton, M. E., & Sparks, T. N. (2023) · Prenatal Diagnosis · doi:10.1002/pd.6298 · Cited by 44
Hu, H.-Y., & Leung, W. K. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241914599 · Cited by 43
Lin, L.-C., Chuan, M.-H., Liu, J.-H., Liao, H., Ng, L. L., Magnusson, M., Jujić, A., Pan, H., Wu, V., & Forni, L. G. (2023) · Critical Care · doi:10.1186/s13054-023-04747-5 · Cited by 44
Wulaningsih, W., Villamaria, C., Akram, A., Benemile, J., Croce, F., & Watkins, J. A. (2024) · Lung · doi:10.1007/s00408-024-00706-1 · Cited by 43
“Risk of bias and applicability were independently assessed using the Quality Assessment of Diagnostic Studies 2 (QUADAS-2) tool [12].”
Witarto, B. S., Witarto, A. P., Visuddho, V., Wungu, C. D. K., Maimunah, U., Rejeki, P. S., & Oceandy, D. (2024) · Lipids in Health and Disease · doi:10.1186/s12944-024-02190-1 · Cited by 42
Blood Astrocyte Biomarkers in Alzheimer Disease: A Systematic Review and Meta-Analysis
Holper, S., Loveland, P. M., Churilov, L. P., Italiano, D., Watson, R., & Yassi, N. (2024) · Neurology · doi:10.1212/wnl.0000000000209537 · Cited by 46
Ye, Z., Zhang, D., Zhao, Y., Chen, M., Wang, H., Seery, S., Qu, Y., Xue, P., & Jiang, Y. (2024) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2024.102934 · Cited by 47
Bonfanti‐Gris, M., Ruales, E., Salido, M. P., Martínez‐Rus, F., Özcan, M., & Pradíes, G. (2024) · Journal of Dentistry · doi:10.1016/j.jdent.2024.105533 · Cited by 40
Midregional proadrenomedullin for prognosis in community-acquired pneumonia: A systematic review
Cavallazzi, R., El‐Kersh, K., Abu-Atherah, E., Singh, S., Loke, Y. K., Wiemken, T. L., & Ramírez, J. A. (2014) · Respiratory Medicine · doi:10.1016/j.rmed.2014.09.018 · Cited by 42
Huang, T., Shyu, Y., Turner, R. M., Chen, H.-Y., & Chen, P. (2013) · Systematic Reviews · doi:10.1186/2046-4053-2-37 · Cited by 42
Pharmacological interventions on early functional gastrointestinal disorders
for the SIPPS Working Group on FGIDs, Salvatore, S., Barberi, S., Borrelli, O., Castellazzi, A. M., Mauro, D. D., Mauro, G. D., Doria, M., Francavilla, R., Landi, M., et al. (2016) · The Italian Journal of Pediatrics/Italian journal of pediatrics · doi:10.1186/s13052-016-0272-5 · Cited by 44
Pei, D., Li, Y., Liu, X., Yan, S., Guo, X., Xu, X., & Guo, X. (2017) · Oncotarget · doi:10.18632/oncotarget.14712 · Cited by 40
Fan, W.-T., Qin, T., Bi, R., Kang, H., Ma, P., & Gu, B. (2017) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-016-2879-2 · Cited by 40
Clinical Characteristics of Pertussis-Associated Cough in Adults and Children
Moore, A., Ashdown, H. F., Shinkins, B., Roberts, N. W., Grant, C. C., Lasserson, D. S., & Harnden, A. (2017) · CHEST Journal · doi:10.1016/j.chest.2017.04.186 · Cited by 43
Inter-rater reliability of AMSTAR is dependent on the pair of reviewers
Pieper, D., Jacobs, A., Weikert, B., Fishta, A., & Wegewitz, U. E. (2017) · BMC Medical Research Methodology · doi:10.1186/s12874-017-0380-y · Cited by 45
Chen, L., Yang, Q., Bao, J., Liu, D., Huang, X., & Wang, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-08852-8 · Cited by 44
The clinical use of circulating microRNAs as non-invasive diagnostic biomarkers for lung cancers
Yang, Y., Hu, Z., Zhou, Y., Zhao, G., Lei, Y., Li, G., Chen, S., Chen, K., Shen, Z., Chen, X., et al. (2017) · Oncotarget · doi:10.18632/oncotarget.21644 · Cited by 41
Wang, D., Huo, Y., Chen, S., Wang, H., Ding, Y., Zhu, X., & Ma, C. (2018) · OncoTargets and Therapy · doi:10.2147/ott.s148189 · Cited by 44
“The tool comprises four domains: patient selection, index test, reference standard, and flow and timing.(16) Two reviewers (DYW and XCZ) independently applied the signaling questions for each domain to the content of the”
Gbinigie, O. A., Ordóñez-Mena, J. M., Fanshawe, T. R., Plüddemann, A., & Heneghan, C. J. (2018) · Journal of Infection · doi:10.1016/j.jinf.2018.06.012 · Cited by 44
Puzzitiello, R. N., Agarwalla, A., Zuke, W. A., Garcia, G. H., & Forsythe, B. (2018) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2018.04.025 · Cited by 40
Suh, C. H., Choi, Y. J., Baek, J. H., & Lee, J. H. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5813 · Cited by 42
Uhlig, J., Uhlig, A., Biggemann, L., Fischer, U., Lotz, J., & Wienbeck, S. (2018) · European Radiology · doi:10.1007/s00330-018-5711-9 · Cited by 40
Hoshino, N., Murakami, K., Hida, K., Sakamoto, T., & Sakai, Y. (2018) · International Journal of Clinical Oncology · doi:10.1007/s10147-018-1349-5 · Cited by 42
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.