QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 3,501–3,600 of 14,770
Santoro, A., Angelico, G., Travaglino, A., Raffone, A., Arciuolo, D., D’Alessandris, N., Inzani, F. S., & Zannoni, G. F. (2021) · Gynecologic Oncology · doi:10.1016/j.ygyno.2021.02.029 · Cited by 43
Kim, D. H., Choi, S. H., Shim, J. H., Kim, S. Y., Lee, S. S., Byun, J. H., & Choi, J. (2021) · Cancers · doi:10.3390/cancers13122975 · Cited by 43
Malnutrition screening tools in gastrointestinal cancer: A systematic review of concurrent validity
Deftereos, I., Djordjevic, A., Carter, V. M., McNamara, J., Yeung, J. M. C., & Kiss, N. K. (2021) · Surgical Oncology · doi:10.1016/j.suronc.2021.101627 · Cited by 44
Roşca, E. C., Tadger, P., Cornea, A., Tudor, R., Oancea, C. I., & Simu, M. A. (2021) · Diagnostics · doi:10.3390/diagnostics11061124 · Cited by 42
Accuracy of cholera rapid diagnostic tests: a systematic review and meta-analysis
Muzembo, B. A., Kitahara, K., Debnath, A., Okamoto, K., & Miyoshi, S.-I. (2021) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2021.08.027 · Cited by 42
Chowdhury, M., Cervantes, E. G., Chan, W.-Y., & Seitz, D. P. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.738466 · Cited by 46
Kalot, M. A., Husainat, N. M., Alayli, A. E., Abughanimeh, O. K. M., Diab, O. A., Tayiem, S., Madoukh, B., Dimassi, A. B., Qureini, A., Ameer, B., et al. (2021) · Blood Advances · doi:10.1182/bloodadvances.2021005430 · Cited by 39
Critical Appraisal Tools and Reporting Guidelines
Haile, Z. T. (2021) · Journal of Human Lactation · doi:10.1177/08903344211058374 · Cited by 48
Kik, C. C., Slooff, W. M., Moayeri, N., de Jong, P. A., Muijs, S. P. J., & Öner, F. C. (2021) · European Radiology · doi:10.1007/s00330-021-08379-7 · Cited by 41
Lee, J. H., Park, Y. S., Kim, M. J., Shin, H. J., Roh, Y. H., Kim, J. H., Chung, H. S., Park, I., & Chung, S. P. (2022) · Academic Emergency Medicine · doi:10.1111/acem.14493 · Cited by 39
MRI detection of suspected nasopharyngeal carcinoma: a systematic review and meta-analysis
Gorolay, V. V., Niles, N. N. A., Huo, Y. R., Ahmadi, N., Hanneman, K. A., Thompson, E., & Chan, M. V. (2022) · Neuroradiology · doi:10.1007/s00234-022-02941-w · Cited by 43
Meyer, H., Wienke, A., & Surov, A. (2021) · Breast Care · doi:10.1159/000514407 · Cited by 43
Causes and Risk Factors of Pediatric Spontaneous Intracranial Hemorrhage—A Systematic Review
Ciochon, U. M., Bindslev, J. B., Hoei‐Hansen, C. E., Truelsen, T. C., Larsen, V. A., Nielsen, M. B., & Hansen, A. E. (2022) · Diagnostics · doi:10.3390/diagnostics12061459 · Cited by 39
Kouli, O., Hassane, A. S. I., Badran, D., Kouli, T., Hossain-Ibrahim, K., & Steele, J. D. (2022) · Neuro-Oncology Advances · doi:10.1093/noajnl/vdac081 · Cited by 44
Accuracy of measures for antiretroviral adherence in people living with HIV
Smith, R., Villanueva, G., Probyn, K., Sguassero, Y., Ford, N. P., Orrell, C., Cohen, K., Chaplin, M., Leeflang, M., & Hine, P. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013080.pub2 · Cited by 53
Self-citationIsmaiel, A., Ciobanu, O. S., Ismaiel, M., Leucuta, D., Popa, S., David, L., Ensar, D., Srouji, N. A., & Dumitrascu, D. L. (2022) · Biomedicines · doi:10.3390/biomedicines10092101 · Cited by 42
Viswanathan, M., Wallace, I., Middleton, J. C., Kennedy, S. M., McKeeman, J. L., Hudson, K. N., Rains, C. B., Schaaf, E. B. V., & Kahwati, L. C. (2022) · JAMA · doi:10.1001/jama.2022.16303 · Cited by 47
Deep Learning for Detecting Brain Metastases on MRI: A Systematic Review and Meta-Analysis
Ozkara, B. B., Chen, M., Federau, C., Karabacak, M., Briere, T. M., Li, J., & Wintermark, M. (2023) · Cancers · doi:10.3390/cancers15020334 · Cited by 48
Almăşan, O. C., Leucuta, D., Hedesiu, M. C., Mureșanu, S., & Popa, S. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12030942 · Cited by 40
“The QUADAS 2 risk of bias assessment (Table 2) [31] and the minimum information about clinical artificial intelligence modeling (MI-CLAIM) checklist (Table 3) [32] were used to study the risk of bias.”
Zhang, W., Han, Z. L., Yang, C., Xu, Y., Xiao, K., Li, A. M., Wang, Y. D., Li, Y., & Liu, S. D. (2014) · Journal of Digestive Diseases · doi:10.1111/1751-2980.12152 · Cited by 39
Predictive validity of the Braden Scale for pressure ulcer risk in hospitalized patients
Park, S., Choi, Y.-K., & Kang, C.-B. (2015) · Journal of Tissue Viability · doi:10.1016/j.jtv.2015.05.001 · Cited by 42
Henry, B. M., Roy, J., Ramakrishnan, P. K., Vikse, J., Tomaszewski, K. A., & Walocha, J. A. (2015) · Clinical Pediatrics · doi:10.1177/0009922815606414 · Cited by 45
Tseng, Y., Zeng, X., Chen, J., Li, N., Xu, P., & Chen, S. (2016) · Digestive and Liver Disease · doi:10.1016/j.dld.2016.02.007 · Cited by 41
Bass, A. R., Fields, K. G., Goto, R., Turissini, G., Dey, S. A., & Russell, L. (2017) · Thrombosis and Haemostasis · doi:10.1160/th17-06-0395 · Cited by 39
Meta-analysis of sonication prosthetic fluid PCR for diagnosing periprosthetic joint infection
Liu, K., Fu, J., Yu, B., Sun, W., Chen, J., & Hao, L. (2018) · PLoS ONE · doi:10.1371/journal.pone.0196418 · Cited by 39
Detection of Volatile Organic Compounds in Exhaled Breath to Screen Lung Cancer: A Systematic Review
Hua, Q., Zhu, Y., & Liu, H. (2018) · Future Oncology · doi:10.2217/fon-2017-0676 · Cited by 39
Using Semiology to Classify Epileptic Seizures vs Psychogenic Nonepileptic Seizures: A Meta-analysis
Muthusamy, S., Seneviratne, U. K., Ding, C., & Phan, T. G. (2022) · Neurology Clinical Practice · doi:10.1212/cpj.0000000000001170 · Cited by 45
Afzalpurkar, S., Giri, S., Kasturi, S., Ingawale, S., & Sundaram, S. (2022) · Surgical Endoscopy · doi:10.1007/s00464-022-09744-3 · Cited by 44
Hu, J., Xie, S., Li, W., & Zhang, L. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1102126 · Cited by 50
Accuracy of serological tests for bovine brucellosis: A systematic review and meta-analysis
Andrade, R. S., de Oliveira, M. M., Filho, J. S. D. S. B., Ferreira, F., Godfroid, J., Lage, A. P., & Dorneles, E. M. S. (2023) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2023.106079 · Cited by 38
Smyth, M. A., Gunson, I. M., Coppola, A., Johnson, S., Greif, R., Lauridsen, K. G., Taylor-Philips, S., & Perkins, G. D. (2024) · JAMA Network Open · doi:10.1001/jamanetworkopen.2024.20040 · Cited by 42
Wusthoff, C. J., Numis, A. L., Pressler, R., Chu, C. J., Massey, S. L., Clancy, R. R., Tich, S. N. T., Hahn, C. D., Scher, M. S., Pilon, B., et al. (2024) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000001120 · Cited by 65
“7 Data were synthesized in evidence pro fi les taking the form of tables and summarized using a narrative approach.”
Computer Vision Technologies in Movement Disorders: A Systematic Review
Pecoraro, P. M., Marsili, L., Espay, A. J., Bologna, M., & di Biase, L. (2025) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.70123 · Cited by 42
D’Alberti, E., Patey, O. V., Smith, C., Šalović, B., Hernandez-Cruz, N., Noble, J. A., & Papageorghiou, A. T. (2025) · EClinicalMedicine · doi:10.1016/j.eclinm.2025.103250 · Cited by 47
“25 We assessed the reporting quality of the included studies guided by Transparent Reporting of a multi-variable prediction model for Individual Prognosis Or Diagnosis + Arti fi cial Intelligence (TRIPOD+AI).”
Yang, X., Yin, P., Yao, X., & Zhang, J. (2025) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-025-06059-6 · Cited by 43
“Two researchers independently evaluated the quality of the diagnostic studies [30] using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).”
Soni, V., Pappu, A., Zarabi, S., Khalil, C., You-Ten, K. E., Siddiqui, N. T., Wong, D. T., Chan, V., Li, Q., Huzsti, E., et al. (2025) · Anaesthesia · doi:10.1111/anae.16751 · Cited by 42
Thiagarajan, K., Cheng, H. L., Huang, J. E., Natarajan, P., Crammond, D. J., Balzer, J. R., & Thirumala, P. D. (2015) · World Neurosurgery · doi:10.1016/j.wneu.2015.08.040 · Cited by 40
Screening for Peripheral Neuropathies in Children With Diabetes: A Systematic Review
Hirschfeld, G. H. F., von Glischinski, M., Blankenburg, M. R., & Zernikow, B. (2014) · PEDIATRICS · doi:10.1542/peds.2013-3645 · Cited by 38
Commercial nucleic acid amplification tests in tuberculous meningitis—a meta-analysis
Solomons, R., van Elsland, S. L., Visser, D. H., Hoek, K. G. P., Marais, B. J., Schoeman, J. F., & van Furth, A. M. (2014) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2014.01.002 · Cited by 42
McGarvey, C., Harb, Z., Smith, C., Houghton, R., Corbett, S. A., & Ajuied, A. (2015) · Skeletal Radiology · doi:10.1007/s00256-015-2299-x · Cited by 38
Diagnostic Accuracy of SuperSonic Shear Imaging for Staging of Liver Fibrosis: A Meta‐analysis
Feng, J., Li, J., Wu, X., & Peng, X. (2016) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.15.03032 · Cited by 44
Ultrasonography for diagnosis of alcoholic cirrhosis in people with alcoholic liver disease
Pavlov, C. S., Casazza, G., Semenistaya, M. C., Nikolova, D., Tsochatzis, E. A., Liusina, E. O., Ivashkin, V. T., & Gluud, C. N. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011602.pub2 · Cited by 46
Liu, L., Cui, L., Zhang, X., Cao, J., Chang, N., Tang, X., Qi, S., Zhang, X., Yin, H. J., & Zhang, J. (2015) · Medicine · doi:10.1097/md.0000000000001998 · Cited by 45
Gao, Y., Cai, Q., Huang, Y., Li, S., Yang, H., Sun, L. J., Chen, K., & Wang, Y. (2016) · Oncotarget · doi:10.18632/oncotarget.9142 · Cited by 38
Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review
Holm, A., & Aabenhus, R. M. (2016) · BMC Family Practice · doi:10.1186/s12875-016-0465-4 · Cited by 38
Luo, X., Xu, H. Y., He, M., Han, Q., Wang, H., Sun, C., Li, J., Jiang, L., Zhou, Y. J., Dan, H., et al. (2016) · Scientific Reports · doi:10.1038/srep29943 · Cited by 38
“…assessment for studies of diagnostic accuracy (QUADAS-2) tool, as another powerful quality-assessing tool, was applied to evaluate the risk of bias and applicability concerns of these included studies in 4 key domains of patient selection, index test, reference standard, and flow and timing 38,39 .”
Rakshasbhuvankar, A. A., Rao, S. C., Palumbo, L., Ghosh, S., & Nagarajan, L. (2017) · Journal of Child Neurology · doi:10.1177/0883073817707411 · Cited by 40
Ding, Y., Yan, J., Fang, A., Zhou, W.-F., & Huang, L. (2017) · Oncotarget · doi:10.18632/oncotarget.18949 · Cited by 38
Kim, S., Koo, P. J., Pak, K., Kim, I., & Kim, K.-Y. (2018) · World Journal of Urology · doi:10.1007/s00345-017-2168-4 · Cited by 41
Bollegala, N. P., Griller, N., Bannerman, H., Habal, M., & Nguyen, G. C. (2019) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izy392 · Cited by 38
Sami, S. S., Iyer, P. G., Pophali, P. A., Halland, M., di Pietro, M., Ortiz‐Fernández‐Sordo, J., White, J. R., Johnson, M. L., Guha, I. N., Fitzgerald, R. C., et al. (2018) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2018.07.019 · Cited by 38
Diagnostic and classification tools for chronic headache disorders: A systematic review
Potter, R., Probyn, K., Bernstein, C., Pincus, T., Underwood, M., & Matharu, M. (2019) · Cephalalgia · doi:10.1177/0333102418806864 · Cited by 36
High performance of critical shoulder angle for diagnosing rotator cuff tears on radiographs
Song, J. G., Yun, S. J., Song, Y. W., & Lee, S. H. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-5247-1 · Cited by 38
Figueiredo, F. B., de Vasconcelos, T. C. B., Madeira, M. D. F., Menezes, R. C., Maia‐Elkhoury, A. N. S., Marcelino, A. P., & Werneck, G. L. (2018) · Memórias do Instituto Oswaldo Cruz · doi:10.1590/0074-02760180260 · Cited by 51
Yeung, L. L., McDonald, A. A., Como, J. J., Robinson, B. R. H., Knight, J., Person, M. A., Lee, J. K., & Dahm, P. (2018) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000002132 · Cited by 38
Kobulashvili, T., Kuchukhidze, G., Brigo, F., Zimmermann, G., Höfler, J., Leitinger, M., Dobesberger, J., Kalss, G., Rohracher, A., Neuray, C., et al. (2018) · Epilepsia · doi:10.1111/epi.14598 · Cited by 38
Fine-needle aspiration to diagnose primary thyroid lymphomas: a systematic review and meta-analysis
Zhang, L., Castellana, M., Virili, C., Crescenzi, A., Giorgino, F., Zucca, E., Ceriani, L., Cavalli, F., Giovanella, L., & Trimboli, P. (2018) · European Journal of Endocrinology · doi:10.1530/eje-18-0672 · Cited by 44
Suh, C. H., Jung, S. C., Cho, S. J., Kim, D., Lee, J. B., Woo, D., Oh, W. Y., Lee, J.-G., & Kim, K. W. (2019) · European Radiology · doi:10.1007/s00330-018-5936-7 · Cited by 42
Manoochehry, S., Vafabin, M., Bitaraf, S., & Amiri, A. (2019) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v7i1.97 · Cited by 38
Krenzien, F., Keshi, E., Splith, K., Griesel, S., Kamali, K., Sauer, I. M., Feldbrügge, L., Pratschke, J., Leder, A., & Schmelzle, M. (2019) · Frontiers in Immunology · doi:10.3389/fimmu.2019.00758 · Cited by 38
Management of idiopathic epistaxis in adults: what’s new?
Meccariello, G., Georgalas, C., Montevecchi, F., Cammaroto, G., Gobbi, R., Firinu, E., Vito, A. D., & Vicini, C. (2019) · Acta Otorhinolaryngologica Italica · doi:10.14639/0392-100x-2155 · Cited by 38
Yang, K., Yu, S., Lu, M., & Zhao, S. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.06.054 · Cited by 38
Balato, G., de Matteo, V., Ascione, T., Donato, S. L. D., Franco, C. D., Smeraglia, F., Baldini, A., & Mariconda, M. (2019) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-019-03232-5 · Cited by 38
Hwang, A. B., Boes, S., Nyffeler, T., & Schuepfer, G. (2019) · PLoS ONE · doi:10.1371/journal.pone.0219569 · Cited by 41
Tayer-Shifman, O. E., Green, R., Beaton, D., Ruttan, L., Wither, J., Tartaglia, M. C., Kakvan, M., Lombardi, S., Anderson, N. D., Su, J., et al. (2020) · Arthritis Care & Research · doi:10.1002/acr.24096 · Cited by 39
Mesman, A. W., Rodriguez, C. A., Ager, E., Coit, J. M., Trevisi, L., & Franke, M. F. (2019) · Tuberculosis · doi:10.1016/j.tube.2019.101878 · Cited by 44
Suh, C. H., Jung, S. C., Cho, S. J., Woo, D., Oh, W. Y., Lee, J.-G., & Kim, K. W. (2019) · Acta Radiologica · doi:10.1177/0284185119887593 · Cited by 39
Canto, E. D., Remmelzwaal, S., van Ballegooijen, A. J., Handoko, M. L., Heymans, S. R. B., van Empel, V. P. M., Paulus, W. J., Nijpels, G., Elders, P. J. M., & Beulens, J. W. J. (2020) · Heart Failure Reviews · doi:10.1007/s10741-020-09985-1 · Cited by 43
Wang, N., Zhang, X., Wang, F., Zhang, M., Sun, B., Yin, W., Deng, S., Wan, Y., & Lü, W. (2020) · SLAS TECHNOLOGY · doi:10.1177/2472630320939565 · Cited by 46
Infrared thermography and musculoskeletal injuries: A systematic review with meta-analysis
Bunn, P. D. S., Miranda, M. E. K., Inoue, A., Sodré, R. D. S., Neves, E. B., & da Silva, E. B. (2020) · Infrared Physics & Technology · doi:10.1016/j.infrared.2020.103435 · Cited by 43
Cornelissen, S. W. E., Veenboer, P. W., Wessels, F. J., & Meijer, R. P. (2020) · Urology · doi:10.1016/j.urology.2020.07.021 · Cited by 40
Ventilation/perfusion SPECT for the diagnosis of pulmonary embolism: A systematic review
Roux, P. L., Robin, P., Tromeur, C., Davis, A., Robert‐Ebadi, H., Carrier, M., Gal, G. L., & Salaün, P. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15038 · Cited by 40
Floriano, I., Silvinato, A., Bernardo, W. M., Reis, J. C., & Soledade, G. N. B. (2020) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.66.7.880 · Cited by 38
Scoppetta, O., Cassiani-Miranda, C. A., Arocha-Díaz, K. N., Cabanzo-Arenas, D. F., & Campo‐Arias, A. (2020) · Journal of Affective Disorders · doi:10.1016/j.jad.2020.09.096 · Cited by 44
Clinical practice guideline for endoscopic resection of early gastrointestinal cancer
Park, C. H., Yang, D., Kim, J. W., Kim, J., Kim, J. H., Min, Y. W., Lee, S. H., Bae, J. H., Chung, H., Choi, K. D., et al. (2020) · Intestinal Research · doi:10.5217/ir.2020.00020 · Cited by 38
Somme, F., Bender, L., Namer, I. J., Noël, G., & Bund, C. (2020) · Cancer Imaging · doi:10.1186/s40644-020-00348-5 · Cited by 38
The Effect of Clinical History on Diagnostic Imaging Interpretation – A Systematic Review
Yapp, K. E., Brennan, P., & Ekpo, E. U. (2020) · Academic Radiology · doi:10.1016/j.acra.2020.10.021 · Cited by 44
Paramalingam, S., Morgan, K., Becce, F., Diederichsen, L. P., Ikeda, K., Mandl, P., Ohrndorf, S., Sedie, A. D., Sharp, V., Tan, A. L., et al. (2020) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2020.11.001 · Cited by 39
Allen, J., Clunie, G., Slinger, C., Haines, J., Mossey‐Gaston, C., Zaga, C. J., Scott, B., Wallace, S., & Govender, R. (2020) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12584 · Cited by 38
Anbarasan, T., Wei, C., Bamber, J. C., Barr, R. G., & Nabi, G. (2021) · Cancers · doi:10.3390/cancers13010122 · Cited by 38
Huo, Z., Lin, J., Bat, B. K. K., Chan, J. Y. C., Tsoi, K. K. F., & Yip, B. H. K. (2021) · Age and Ageing · doi:10.1093/ageing/afab005 · Cited by 41
Crescenzi, A., Palermo, A., & Trimboli, P. (2021) · Journal of Endocrinological Investigation · doi:10.1007/s40618-021-01526-3 · Cited by 38
Umay, E., Eyigör, S., Ertekin, C., Ünlü, Z., Selçuk, B., Bahat, G., Karahan, A. Y., Seçıl, Y., Gürçay, E., Kıylıoğlu, N., et al. (2021) · Dysphagia · doi:10.1007/s00455-021-10273-9 · Cited by 41
Moezzi, M., Shirbandi, K., Shahvandi, H. K., Arjmand, B., & Rahim, F. (2021) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2021.100591 · Cited by 39
“2020 [20] Korea Yes DL RT-PCR 337 998 0.”
Fontenele, R. C., Machado, A. H., Reis, L. D. O., & Freitas, D. Q. (2021) · International Endodontic Journal · doi:10.1111/iej.13569 · Cited by 39
Park, H. Y., Park, C. R., Suh, C. H., Kim, M., Shim, W. H., & Kim, S. J. (2021) · American Journal of Neuroradiology · doi:10.3174/ajnr.a7168 · Cited by 38
Ultrasound Imaging versus Radiographs in Differentiating Periapical Lesions: A Systematic Review
Patil, S., Alkahtani, A., Bhandi, S., Mashyakhy, M., Alvarez, M., Alroomy, R., Hendi, A., Varadarajan, S., Reda, R., Raj, A. T., et al. (2021) · Diagnostics · doi:10.3390/diagnostics11071208 · Cited by 38
Bang, C. S., Lee, J. J., & Baik, G. H. (2021) · Journal of Medical Internet Research · doi:10.2196/29682 · Cited by 41
“The 2 authors assessed each part as having a high, low, or unclear risk of bias [16].”
Melatonin and adolescent idiopathic scoliosis: The present evidence
Gargano, G., Oliva, F., Migliorini, F., & Maffulli, N. (2021) · The Surgeon · doi:10.1016/j.surge.2021.07.008 · Cited by 41
Griffiths, E. (2021) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/s13049-021-00977-0 · Cited by 46
Saw, K. S., Liu, C., Xu, W., Varghese, C., Parry, S., & Bissett, I. P. (2021) · British journal of surgery · doi:10.1093/bjs/znab411 · Cited by 49
Prendiville, T., Leahy, A. M., Quinlan, L., Saleh, A., Shanahan, E., Gabr, A., Peters, C., Casserly, I. P., O’Connor, M., & Galvin, R. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-049216 · Cited by 39
Zhang, J., Huang, S., Xu, Y., & Wu, J. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.763842 · Cited by 43
“Two reviewers independently assessed the quality of the eligible articles using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria and the four domains of patient selection, index test, reference standard, and fl ow of patients through the study (26).”
Yang, J., Zhang, F., & Qiao, Y. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-051568 · Cited by 38
Lathan, R., Sidapra, M., Yiasemidou, M., Long, J. A., Totty, J. P., Smith, G., & Chetter, I. C. (2022) · PLoS ONE · doi:10.1038/s41746-022-00655-0 · Cited by 43
Xue, Y., Zhou, Y., Wang, T., Chen, H., Wu, L., Ling, H., Wang, H., Qiu, L., Ye, D., & Wang, B. (2022) · International Journal of Endocrinology · doi:10.1155/2022/9492056 · Cited by 39
European consensus for the diagnosis of MCI and mild dementia: Preparatory phase
Festari, C., Massa, F., Ramusino, M. C., Gandolfo, F., Nicolosi, V., Orini, S., Aarsland, D., Agosta, F., Babiloni, C., Boada, M., et al. (2022) · Alzheimer s & Dementia · doi:10.1002/alz.12798 · Cited by 39
Fragkou, P. C., Moschopoulos, C. D., Dimopoulou, D., Ong, D. S. Y., Dimopoulou, K., Nelson, P. P., Schweitzer, V. A., Janocha, H., Karofylakis, E., Papathanasiou, K. A., et al. (2022) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2022.10.028 · Cited by 46
Wu, G., Khair, S., Yang, F., Cheligeer, C., Southern, D. A., Zhang, Z., Feng, Y., Xu, Y., Quan, H., Williamson, T. S., et al. (2022) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2022.104956 · Cited by 49
João, V., Castelo, F., Barros, B. S., Ribau, A., Carvalho, A., & de Sousa, R. J. G. (2023) · The Journal of Arthroplasty · doi:10.1016/j.arth.2023.06.017 · Cited by 38
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.