QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 3,901–4,000 of 14,770
Wilson, M. P., Lui, K., Nobbee, D., Murad, M. H., McInnes, M. D. F., McGrath, T. A., Katlariwala, P., & Low, G. (2020) · European Radiology · doi:10.1007/s00330-020-07236-3 · Cited by 36
“The risk of bias and applicability of each study were evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [12].”
Guzzi, F., Cirillo, L., Buti, E., Becherucci, F., Errichiello, C., Roperto, R. M., Hunter, J. P., & Romagnani, P. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186889 · Cited by 41
Wang, Q., Wang, C. C., Hu, W., Hu, F., Liu, W., & Zhang, X. (2020) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-020-01988-w · Cited by 34
Yu, G., Zhao, W., Shen, Y., Zhu, P., & Zheng, H. (2020) · PLoS ONE · doi:10.1371/journal.pone.0243161 · Cited by 34
Kotepui, M., Masangkay, F. R., Kotepui, K. U., & Milanez, G. D. J. (2020) · Scientific Reports · doi:10.1038/s41598-020-78691-7 · Cited by 37
Gebre, M., Cameron, L. H., Tadesse, G., Woldeamanuel, Y. W., & Wassie, L. (2020) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofaa627 · Cited by 34
Aly, M. M., Al-Shoaibi, A. M., Alzahrani, A., & Fattani, A. A. (2021) · World Neurosurgery · doi:10.1016/j.wneu.2021.04.106 · Cited by 34
Piccardo, A., Fiz, F., Bottoni, G., Ugolini, M., Noordzij, W., & Trimboli, P. (2021) · Clinical Endocrinology · doi:10.1111/cen.14527 · Cited by 37
Gilmour, G. S., MacIsaac, R., Subotic, A., Wiebe, S., & Josephson, C. B. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2021.108030 · Cited by 38
Olsen, M., Lof, P., Stiekema, A., van den Broek, D. A., Wilthagen, E. A., Bossuyt, P. M., & Lok, C. A. R. (2021) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.14224 · Cited by 38
Self-citationDisease Activity Indices for Pouchitis: A Systematic Review
Sedaño, R., Nguyen, T. M., Almradi, A., Rieder, F., Parker, C. E., Shackelton, L. M., D’Haens, G., Sandborn, W. J., Feagan, B. G., Ma, C., et al. (2021) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izab124 · Cited by 34
Wang, B., Zhu, C., Liu, H., Yao, X.-M., & Wu, J. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.701253 · Cited by 34
Hand-Held Ultrasound of the Lung: A Systematic Review
Haji-Hassan, M., Lenghel, L. M., & Bolboaca, S. D. (2021) · Diagnostics · doi:10.3390/diagnostics11081381 · Cited by 34
Kassirian, S., Hinton, S. N., Iansavitchene, A., Amjadi, K., Chee, A., Dhaliwal, I., & Mitchell, M. A. (2021) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202103-366oc · Cited by 38
Song, D., Topriceanu, C., Ilie-Ablachim, D. C., Kinali, M., & Bisdas, S. (2021) · Neuroradiology · doi:10.1007/s00234-021-02774-z · Cited by 37
Serum Cystatin C as a predictor of acute kidney injury in neonates: a meta-analysis
Yang, H., Lin, C., Zhuang, C., Chen, J., Jia, Y., Shi, H., & Zhuang, C. (2021) · Jornal de Pediatria · doi:10.1016/j.jped.2021.08.005 · Cited by 34
Janka, E. A., Várvölgyi, T., Sipos, Z., Soós, A., Hegyi, P. J., Kiss, S., Dembrovszky, F., Csupor, D., Kéringer, P., Pécsi, D., et al. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.772165 · Cited by 41
Marchesini, G., Bugianesi, E., Burra, P., Marra, F., Miele, L., Alisi, A., Vajro, P., Masarone, M., Petta, S., Persico, M., et al. (2021) · Digestive and Liver Disease · doi:10.1016/j.dld.2021.04.029 · Cited by 38
Computerized migraine diagnostic tools: a systematic review
Woldeamanuel, Y. W., & Cowan, R. P. (2022) · Therapeutic Advances in Chronic Disease · doi:10.1177/20406223211065235 · Cited by 35
Jumaah, A. S., Al‐Haddad, H. S., McAllister, K. A., & Yasseen, A. A. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263585 · Cited by 38
Systematic Review and Meta-Analysis of Screening Tools for Language Disorder
So, K. K. H., & To, C. K. S. (2022) · Frontiers in Pediatrics · doi:10.3389/fped.2022.801220 · Cited by 39
“Quality assessment of included articles was conducted by the first author using QUADAS-2 by Whiting, Rutjes (20).”
MethodHan, Z., Chen, Q., Zhang, L., Mo, X., You, J., Chen, L., Jin, F., Wang, F., Jin, Z., Zhang, S., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08607-8 · Cited by 34
Zhou, J., Li, X., Wang, X., Yu, N. H., & Wang, W. (2022) · npj Primary Care Respiratory Medicine · doi:10.1038/s41533-022-00275-x · Cited by 40
Mori, T., Ihara, T., & Nomura, O. (2022) · Emergency Medicine Journal · doi:10.1136/emermed-2021-212281 · Cited by 37
Brekke, R. L., Almeland, S. K., Hufthammer, K. O., & Hansson, E. (2022) · Burns · doi:10.1016/j.burns.2022.05.007 · Cited by 36
Natural language processing in low back pain and spine diseases: A systematic review
Bacco, L., Russo, F., Ambrosio, L., D’Antoni, F., Vollero, L., Vadalà, G., Dell’Orletta⋄, F., Merone, M., Papalia, R., & Denaro, V. (2022) · Frontiers in Surgery · doi:10.3389/fsurg.2022.957085 · Cited by 39
Computer-aided anatomy recognition in intrathoracic and -abdominal surgery: a systematic review
den Boer, R. B., de Jongh, C., Huijbers, W. T. E., Jaspers, T. J. M., Pluim, J. P. W., van Hillegersberg, R., van Eijnatten, M. A. J. M., & Ruurda, J. P. H. (2022) · Surgical Endoscopy · doi:10.1007/s00464-022-09421-5 · Cited by 37
Pfeffer, D. A., Satyagraha, A. W., Sadhewa, A., Alam, M. S., Bancone, G., Boum, Y., Brito, M. A. M., Cui, L., Deng, Z., Domingo, G. J., et al. (2022) · Pathogens · doi:10.3390/pathogens11091045 · Cited by 43
Qu, C., Chen, Y., Ouyang, Y., Huang, W., Liu, F., Yan, L., Lu, R., Zeng, Y., & Liu, Z. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.989280 · Cited by 43
Hantouly, A. T., Alzobi, O. Z. A., Toubasi, A. A., Zikria, B. A., Dosari, M. A. A. A., & Ahmed, G. (2022) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-022-07196-9 · Cited by 36
Ultrathin Bronchoscopy for the Diagnosis of Peripheral Pulmonary Lesions: A Meta-Analysis
Kim, S. H., Kim, J., Pak, K., & Eom, J. S. (2022) · Respiration · doi:10.1159/000527362 · Cited by 36
Islam, M. M., Poly, T. N., Walther, B. A., Yeh, C.-Y., Syed-Abdul, S., Li, Y.-C., & Lin, M. (2022) · Cancers · doi:10.3390/cancers14235996 · Cited by 39
Pantiora, E. V., Tasoulis, M. K., Valachis, A., Eriksson, S., Kühn, T., Karakatsanis, A., & Rubio, I. T. (2022) · British journal of surgery · doi:10.1093/bjs/znac426 · Cited by 34
Cimini, L. A., Candeloro, M., Pływaczewska, M., Maraziti, G., Nisio, M. D., Pruszczyk, P., Agnelli, G., & Becattini, C. (2022) · ERJ Open Research · doi:10.1183/23120541.00641-2022 · Cited by 34
Qiu, X., Wu, Y., Sun, Y., Levis, B., Tian, J., Boruff, J. T., Cuijpers, P. J., Ioannidis, J. P. A., Markham, S., Ziegelstein, R. C., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-29114-w · Cited by 37
Self-citationUhrin, E., Domokos, Z., Czumbel, L. M., Kói, T., Hegyi, P. J., Hermann, P., Borbély, J., Cavalcante, B. G. N., & Németh, O. (2023) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2022.0426 · Cited by 39
The Alberta Heart Failure Etiology and Analysis Research Team (HEART) study
Ezekowitz, J. A., Becher, H. H., Belenkie, I., Clark, A. M., Duff, H. J., Friedrich, M. G., Haykowsky, M. J., Howlett, J. G., Kassiri, Z., Kaul, P., et al. (2014) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-14-91 · Cited by 36
Patel, K., Hadar, N., Lee, J., Siegel, B. A., Hillner, B. E., & Lau, J. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.119362 · Cited by 34
Chen, Y., Gi, W., Liao, T.-Y., Lee, M.-T. G., Lee, S.-H., Hsu, W., Chang, S.-S., & Lee, C. (2016) · Biomarkers in Medicine · doi:10.2217/bmm.15.121 · Cited by 37
Uroflowmetry in healthy women: A systematic review
Sorel, M. R., Reitsma, J. B., Rosier, P. F. W. M., Bosch, J. L. H. R., & de Kort, L. M. O. (2016) · Neurourology and Urodynamics · doi:10.1002/nau.23051 · Cited by 34
Self-citationMa, R., Yin, S., & Li, G. (2016) · Scientific Reports · doi:10.1038/srep34714 · Cited by 34
Cao, S., Hu, Y., Gao, X., Liao, Q., & Zhao, Y. (2016) · PLoS ONE · doi:10.1371/journal.pone.0166406 · Cited by 36
Diagnostic accuracy of urine HE4 in patients with ovarian cancer: a meta-analysis
Jia, M.-M., Deng, J., Cheng, X., Yan, Z., Li, Q., Xing, Y.-Y., Fan, D., & Tian, X. (2016) · Oncotarget · doi:10.18632/oncotarget.14173 · Cited by 37
Howlett, H., Abernethy, S., Brown, N. W., Rankin, J. M., & Gray, W. K. (2017) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2017.04.005 · Cited by 40
Shinkins, B., Nicholson, B. D., James, T. J., Pathiraja, I., Pugh, S. A., Perera, R., Primrose, J. M., & Mant, D. (2017) · Health Technology Assessment · doi:10.3310/hta21220 · Cited by 36
McFadden, E. C., Hirst, J. A., Verbakel, J. Y. J., McLellan, J., Hobbs, R. F., Stevens, R., O’Callaghan, C. A., & Lasserson, D. S. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2017.276683 · Cited by 34
Fuller, G. W., Cross, M., Stokes, K., & Kemp, S. P. T. (2018) · British Journal of Sports Medicine · doi:10.1136/bjsports-2017-098560 · Cited by 38
Qumseya, B. J., Bartel, M. J., Gendy, S., Bain, P. A., Qumseya, A., & Wolfsen, H. C. (2018) · Digestive and Liver Disease · doi:10.1016/j.dld.2018.02.005 · Cited by 34
Ibraheem, K., Toraih, E. A., Haddad, A. B., Farag, M., Randolph, G. W., & Kandil, E. H. (2018) · The Laryngoscope · doi:10.1002/lary.27213 · Cited by 35
Cargnin, S., Genazzani, A. A., Canonico, P. L., & Terrazzino, S. (2018) · Pharmacological Research · doi:10.1016/j.phrs.2018.07.021 · Cited by 35
Classification and Outcome Measures for Psoriatic Arthritis
Leung, Y. Y., Ogdie, A., Orbai, A., Tillett, W. L., Coates, L. C., Strand, V., Mease, P. J., & Gladman, D. D. (2018) · Frontiers in Medicine · doi:10.3389/fmed.2018.00246 · Cited by 34
Cook, C. J., Cook, C. E., Reiman, M. P., Joshi, A. B., Richardson, W. J., & Garcia, A. N. (2019) · European Spine Journal · doi:10.1007/s00586-019-06048-4 · Cited by 41
Fernández‐Bañares, F., Carrasco, A., Martín‐Cardona, A., & Esteve, M. (2019) · Nutrients · doi:10.3390/nu11091992 · Cited by 39
Methods and reporting of kidney function: a systematic review of studies from sub-Saharan Africa
Fabian, J., George, J. A., Etheredge, H. R., Deventer, M. V., Kalyesubula, R., Wade, A. N., Tomlinson, L. A., Tollman, S. M., & Naicker, S. (2019) · Clinical Kidney Journal · doi:10.1093/ckj/sfz089 · Cited by 34
Castellana, M., Trimboli, P., Piccardo, A., Giovanella, L., & Treglia, G. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8091333 · Cited by 36
Liu, F., Cheng, X., Dong, J., Zhou, D., Sun, Q., Bai, X., & Wang, D. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2876-6 · Cited by 35
Wang, L., Wang, C., Li, C., Murai, T., Bai, Y., Song, Z., Zhang, S., Zhang, Q., Huang, Y., Bi, X., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01933-3 · Cited by 33
“TheriskofbiasandapplicabilityofallselectedstudieswereassessedbyusingtheQUADAS-2criteria 137 .”
Soldera, J., Camazzola, F., Rodríguez, S., & Brandão, A. (2018) · World Journal of Hepatology · doi:10.4254/wjh.v10.i11.877 · Cited by 33
Application of Artificial Intelligence for Nasopharyngeal Carcinoma Management – A Systematic Review
Ng, W. T., But, B., Choi, H. C., de Bree, R., Lee, A. W., Lee, V. H., López, F., Mäkitie, A. A., Rodrigo, J. P., Saba, N. F., et al. (2022) · Cancer Management and Research · doi:10.2147/cmar.s341583 · Cited by 33
Patel, A., Spychalski, P., Aszkiełowicz, A., Mikaszewski, B., & Kobiela, J. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10225393 · Cited by 33
Yu, G., Zhong, F., Shen, Y., & Zheng, H. (2021) · PLoS ONE · doi:10.1371/journal.pone.0257220 · Cited by 35
Bellato, A., Hall, C. L., Groom, M. J., Simonoff, E. A., Thapar, A., Hollis, C. P., & Cortese, S. (2023) · Journal of Child Psychology and Psychiatry · doi:10.1111/jcpp.13901 · Cited by 41
Praveen, A. D., Sollmann, N., Baum, T. H., Ferguson, S. J., & Helgason, B. (2024) · Osteoporosis International · doi:10.1007/s00198-024-07029-0 · Cited by 35
Tsili, A. C., Alexiou, G. Α., Tzoumpa, M., Siempis, T., & Argyropoulou, M. I. (2024) · Cancers · doi:10.3390/cancers16081467 · Cited by 41
Zary, M., Mohamed, M. S., Kafie, C., Chilala, C. I., Bahukudumbi, S., Foster, N., Gore, G. C., Fielding, K., Subbaraman, R., & Schwartzman, K. (2024) · BMJ Global Health · doi:10.1136/bmjgh-2024-015633 · Cited by 37
“Patients and the public were not specifically involved in the design, conduct, reporting or dissemination plans of our research.”
Li, Y., Deng, J., Ma, X., Li, W., & Wang, Z. (2024) · European Radiology · doi:10.1007/s00330-024-11036-4 · Cited by 40
“The quality of the study was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [12], a standard for diagnostic accuracy meta-analyses, assessing patient selection, index testing, reference standards, and study fl ow for bias and applicability.”
Valente, K. D. R., Reilly, C. J., Carvalho, R. M., Smith, M. L., Mula, M., Wirrell, E. C., Wilmshurst, J. M., Jetté, N., Brigo, F., Kariuki, S. M., et al. (2024) · Epilepsia · doi:10.1111/epi.18116 · Cited by 37
“32 Overall assessment of bias was based on responses to four domains: (1) patient selection, (2) index test, (3) reference standard, and (4) flow and timing (flow of patients through the study and timing of index tests) and reference standard, for which there were multiple signaling questions to…”
Chen, Z., Yi, G., Li, X., Yi, B., Bao, X., Zhang, Y., Zhang, X., Yang, Z., & Guo, Z. (2024) · BMC Cancer · doi:10.1186/s12885-024-13098-5 · Cited by 40
“The quality of the selected studies was assessed by two researchers (ZC and ZJG) using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool in ReviewManager version 5.4 (RevMan for Windows 7, Nordic Cochrane Centre) [14].”
MethodInfluentialPeng, L., Ma, W., Zhong, L., Yang, J., Wu, H., Zhu, L., Huang, X., Yang, R., Li, B., Ma, W., et al. (2024) · Pathogens · doi:10.3390/pathogens13121050 · Cited by 31
Gatti, M., FILIPPO, O. D., Curà, G. C., Dusi, V., Vita, U. D., Gallone, G., Morena, A., Palmisano, A., Pasinato, E., Solano, A., et al. (2024) · European Radiology · doi:10.1007/s00330-024-11283-5 · Cited by 36
“The risk of bias in the included studies was assessed using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) method [19].”
Evaluating the impact of the Radiomics Quality Score: a systematic review and meta-analysis
Barry, N., Kendrick, J., Molin, K., Li, S., Rowshanfarzad, P., Hassan, G. M., Dowling, J., Parizel, P. M., Hofman, M. S., & Ebert, M. A. (2025) · European Radiology · doi:10.1007/s00330-024-11341-y · Cited by 41
“[36], TRIPOD (21/130, 16.2”
InfluentialDeep learning for age estimation from panoramic radiographs: A systematic review and meta-analysis
Rokhshad, R., Nasiri, F., Saberi, N., Shoorgashti, R., Ehsani, S., Nasiri, Z., Azadi, A., & Schwendicke, F. (2025) · Journal of Dentistry · doi:10.1016/j.jdent.2025.105560 · Cited by 39
Riemma, G., Parry, J. P., FRANCISCIS, P. D., Carugno, J. A., Lettieri, D., Cobellis, L., Vitagliano, A., Etrusco, A., Lin, L., Angioni, S. L., et al. (2025) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2025.03.005 · Cited by 39
Quartuccio, N., Caobelli, F., Evangelista, L., Alongi, P., Kirienko, M., Biasi, V. D., & Cocciolillo, F. (2015) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2015.05.002 · Cited by 34
Thombs, B. D., Benedetti, A., Kloda, L. A., Levis, B., Azar, M., Riehm, K. E., Saadat, N., Cuijpers, P. J., Gilbody, S. M., Ioannidis, J. P. A., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-011913 · Cited by 36
Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review.
Kane, S. A., Blake, J. R., McArdle, F. J., Langley, P., & Sims, A. J. (2016) · Open Heart · doi:10.1136/openhrt-2015-000362 · Cited by 27
Procalcitonin-guided therapy for the initiation of antibiotics in the ED: a systematic review
van der Does, Y., Rood, P. P. M., Haagsma, J. A., Patka, P., Gorp, E. C. M. V., & Limper, M. (2016) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2016.03.065 · Cited by 35
Field accuracy of fourth-generation rapid diagnostic tests for acute HIV-1
Lewis, J. M., MacPherson, P., Adams, E. R., Ochodo, E., Sands, A., & Taegtmeyer, M. (2015) · AIDS · doi:10.1097/qad.0000000000000855 · Cited by 33
Diagnostic value of microRNAs as biomarkers for cholangiocarcinoma
Liang, Z., Liu, X., Zhang, Q., Wang, C., & Zhao, Y. (2016) · Digestive and Liver Disease · doi:10.1016/j.dld.2016.07.006 · Cited by 35
Horrocks, S., Wilkinson, T., Schnier, C., Ly, A., Woodfield, R., Rannikmäe, K., Quinn, T. J., & Sudlow, C. L. M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172639 · Cited by 34
Zhang, G., Li, Z., Si, D., & Shen, L. (2017) · Oncotarget · doi:10.18632/oncotarget.20394 · Cited by 33
Zhang, R., Chen, B., Tong, X., Wang, Y., Wang, C., Jin, J., Tian, P., & Li, W. (2018) · Cancer Management and Research · doi:10.2147/cmar.s161382 · Cited by 33
“27”
Christian, B., Armstrong, R., Calache, H., Carpenter, L. M., Gibbs, L. F., & Gussy, M. G. (2018) · International Journal of Paediatric Dentistry · doi:10.1111/ipd.12446 · Cited by 34
Horner, D. E., Pandor, A., Goodacre, S. W., Clowes, M., & Hunt, B. J. (2018) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14367 · Cited by 37
The outcome after surgical vs nonsurgical treatment of chronic subdural hematoma with dexamethasone
Fountas, K. N., Kotlia, P., Panagiotopoulos, V. E., & Fotakopoulos, G. (2019) · Interdisciplinary Neurosurgery · doi:10.1016/j.inat.2018.12.011 · Cited by 33
Li, M., Zeng, Y., Wu, Y., Si, H., Bao, X., & Shen, B. (2019) · The Journal of Arthroplasty · doi:10.1016/j.arth.2019.02.044 · Cited by 33
Vestito, A., Marasco, G., Maconi, G., Festi, D., Bazzoli, F., & Zagari, R. M. (2019) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0865-1842 · Cited by 33
Lee, S. H., & Yun, S. J. (2019) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-019-01169-3 · Cited by 36
Nia, H. S., Lehto, R. H., Sharif, S. P., Mashrouteh, M., Goudarzian, A. H., Rahmatpour, P., Torkmandi, H., & Yaghoobzadeh, A. (2019) · OMEGA - Journal of Death and Dying · doi:10.1177/0030222819865407 · Cited by 34
Wang, Q., Ma, J., Jiang, Z., Wu, F., Ping, J., & Ming, L. (2017) · Medicine · doi:10.1097/md.0000000000007173 · Cited by 33
Kinalski, M. D. A., Boscato, N., & Damián, M. F. (2019) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20190149 · Cited by 33
Pandor, A., Horner, D. E., Davis, S., Goodacre, S. W., Stevens, J., Clowes, M., Hunt, B. J., Nokes, T., Keenan, J., & de Wit, K. (2019) · Health Technology Assessment · doi:10.3310/hta23630 · Cited by 38
Seo, Y. S., Kang, J., Kim, D. S., & Ahn, J. G. (2020) · BMC Infectious Diseases · doi:10.1186/s12879-019-4745-1 · Cited by 42
Charach, A., Mohammadzadeh, F., Bélanger, S. A., Easson, A. K., Lipman, E. L., McLennan, J. D., Parkin, P. C., & Szatmári, P. (2020) · PubMed Central · Cited by 64
Choi, Y., Shin, N., Jang, J., Ahn, K. J., & Kim, B. (2020) · Neuroradiology · doi:10.1007/s00234-020-02486-w · Cited by 33
Potential diagnostic value of miRNAs in peripheral blood for osteosarcoma: A meta-analysis
Gao, S., Wang, Y., Zhang, G., & Zhang, W. (2020) · Journal of bone oncology · doi:10.1016/j.jbo.2020.100307 · Cited by 35
Jayanth, A., Benabbas, R., Chao, J. H., & Sinert, R. H. (2020) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2020.09.024 · Cited by 33
Ayala, L., Winter, S. L., Byrne, R., Fehlings, D. L., Gehred, A. P., Letzkus, L., Noritz, G. H., Paton, M. C. B., Pietruszewski, L., Rosenberg, N., et al. (2020) · Pediatric Neurology · doi:10.1016/j.pediatrneurol.2020.10.014 · Cited by 34
Diagnostic accuracy of Xpert MTB/RIF for tuberculous meningitis: systematic review and meta‐analysis
Hernández, A. V., de Laurentis, L. S., de Souza, I. M., Pessanha, M., Thota, P., Roman, Y. M., Barboza, J. J., Boulware, D. R., & Vidal, J. E. (2020) · Tropical Medicine & International Health · doi:10.1111/tmi.13525 · Cited by 42
Liu, H.-C., Gao, Y.-L., Li, D., Zhao, X., Pan, Y., & Zhu, C. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.02170-20 · Cited by 35
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.