QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 6,201–6,300 of 14,770
Peng, Q., Feng, Z., Shen, Y., Zhu, J., Zou, L., Shen, Y., & Zhu, Y. (2019) · Cancer Cell International · doi:10.1186/s12935-019-0907-x · Cited by 19
Milas, G. P., Karageorgiou, V., & Cholongitas, Ε. (2019) · Expert Review of Gastroenterology & Hepatology · doi:10.1080/17474124.2019.1653757 · Cited by 18
Rapid diagnostic tests for plague
Jullien, S., Dissanayake, H. A., & Chaplin, M. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013459.pub2 · Cited by 18
Wei, R., Wang, C., He, F., Hong, L., Zhang, J., Bao, W., Meng, F., & Luo, B. (2019) · PLoS ONE · doi:10.1371/journal.pone.0226295 · Cited by 18
Lysdahlgaard, S., Hess, S., Gerke, O., & Kusk, M. W. (2020) · European Radiology · doi:10.1007/s00330-020-06735-7 · Cited by 18
Chen, K., Malik, A. A., Nantasenamat, C., Ahmed, S., Chaudhary, O., Sun, C., Sheng, Y.-J., Chen, W., Wu, G., Deng, C., et al. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.03.023 · Cited by 18
Zhou, H., Cui, J., Lü, Y., Sun, J., & Liu, J. (2021) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2021.9817 · Cited by 22
Hyperbilirubinaemia alone cannot distinguish a perforation in acute appendicitis
Silva, F. R., da Rosa, M. I., Silva, B. R., Simon, C. S., Alexandre, M. C. M., Medeiros, L. R., Bitencourt, F. S., & dos Reis, M. E. F. (2015) · ANZ Journal of Surgery · doi:10.1111/ans.12989 · Cited by 21
“Signalling questions are included to help judge the risk of bias.(9) Quality assessment of studies was independently performed by M.”
Nabheerong, P., Kengkla, K., Saokaew, S., & Naravejsakul, K. (2023) · Journal of Ultrasound · doi:10.1007/s40477-022-00759-z · Cited by 18
Iguchi, M., Noguchi, Y., Yamamoto, S., Tanaka, Y., & Tsujimoto, H. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012824 · Cited by 17
Donohue, R., Mashoto, K., Mubyazi, G., Madon, S., Malecela, M., & Michael, E. (2017) · Tropical Medicine and Infectious Disease · doi:10.3390/tropicalmed2040061 · Cited by 17
Groeneveld, N. S., Bijlsma, M. W., van de Beek, D., & Brouwer, M. C. (2024) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2024.12.009 · Cited by 20
Lu, F., Zhao, Y., Wang, Z., & Feng, N. (2025) · European Radiology · doi:10.1007/s00330-025-11387-6 · Cited by 17
Marchi, G., Cucchiara, F., Gregori, A., Biondi, G., Guglielmi, G., Serradori, M., Gherardi, M., Gabbrielli, L., Pistelli, F., & Carrozzi, L. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14062062 · Cited by 18
“A Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) framework [26] was applied whenever possible to evaluate the risk of bias and reliability of included diagnostic studies.”
Machine Listening for OSA Diagnosis
Tan, B. K. J., Gao, E. Y., Tan, N. K. W., Yeo, B. S. Y., Tan, C. J., Ng, A. C. W., Leong, Z. H., Phua, C. Q., Uataya, M., Goh, L. C., et al. (2025) · CHEST Journal · doi:10.1016/j.chest.2025.04.006 · Cited by 18
Determining the Variability Associated with Visual Acuity and Refractive Error Measurements
van der Zee, C., Muijzer, M. B., Claessens, J. L. J., & Wisse, R. P. L. (2025) · Ophthalmology · doi:10.1016/j.ophtha.2025.04.021 · Cited by 17
Sabater-Martos, M., Clauss, M., Ribau, A., de Sousa, R. J. G., & On Behalf Of The Leukocyte Count Synovial Fluid Working Group For The Unified Pji Definition Task Force (2025) · Journal of Bone and Joint Infection · doi:10.5194/jbji-10-165-2025 · Cited by 17
“Heterogeneity in the reported sensitivities and specifici-ties was assessed by using Higgins’ I statistic All statistical analyses were performed with Jamovi (version 2.2.5) and Meta-disc (versions 1–4”
InfluentialArtificial Intelligence Tools in Dentistry: A Systematic Review on Their Application and Outcomes
Tyagi, M., Jain, S. B., Ranjan, M., Hassan, S., Prakash, N., Kumar, D., Kumar, A., & Singh, S. (2025) · Cureus · doi:10.7759/cureus.85062 · Cited by 33
Yahiro, D. S., Leite, L. F., Junior, G. L. D. A., Al-Mallah, M. H., & Mesquita, C. T. (2025) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2025.102279 · Cited by 17
Olayode, O. O., Ogunoye, B. T., Oladeji, E. O., Olayinka, O. E., & Oladosu, T. J. (2025) · BMC Cancer · doi:10.1186/s12885-025-14583-1 · Cited by 17
“The methodological quality of the included articles was evaluated using the QUADAS-2 tool, a standardized framework designed to assess the risk of bias and applicability concerns in diagnostic accuracy research [16].”
Shkurti, J., van den Berg, K., Tissier, R., van der Mierden, S., Lahaye, M. J., Beets‐Tan, R. G. H., & Nederend, J. (2025) · European Radiology · doi:10.1007/s00330-025-11844-2 · Cited by 19
“The methodological quality of the eligible articles was assessed individually using the revised tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) [16] by the two previously mentioned investigators (J.S., K.B.) independently, resolving disagreements through discussion.”
Daray, F. M., Grendas, L. N., Neupane, S. P., Chiapella, L. C., Fisher, P. W., Gould, M. S., Posner, K., Galfalvy, H., Jaffe, C., & Mann, J. J. (2025) · The British Journal of Psychiatry · doi:10.1192/bjp.2025.10316 · Cited by 22
“37 Although QUADAS-2 is primarily designed for evaluating the risk of bias in diagnostic accuracy studies, we adapted it for assessing methodological quality in the prospective prediction of suicide attempts and suicidal behaviour studies, given the absence of a widely accepted alternative tool.”
Mina, A., Younesi, M., Doohandeh, T., Darzi, S., Ardehjani, N. A., Sheibani, S., Hosseinirad, H., & Valizadeh, R. (2025) · Contraception and Reproductive Medicine · doi:10.1186/s40834-025-00400-4 · Cited by 20
“…of Diagnostic Accuracy Studies (QUADAS-2) tool, recommended by the Cochrane collaboration for the risk of bias and applicability concerns [20] in which “Patient Selection”, “Details of used index test”, “Details of used standard test”, and “how to follow the samples and perform the…”
Vallée, A., Drezet, A., & Arutkin, M. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2025.1672312 · Cited by 17
Nedelcu, A., Oerther, B., Benkendorff, A., Dieckbreder, S., Schwarzer, G., Agrotis, G., Schoots, I. G., Matine, R. E., Eisenblätter, M., Sigle, A., et al. (2025) · American Journal of Roentgenology · doi:10.2214/ajr.25.33583 · Cited by 19
Zubair, M., Khan, A. H., Bilal, S. F., & Li, J. (2025) · Briefings Bioinform. · doi:10.1093/bib/bbaf541 · Cited by 14
“To ensure objectivity, our quality framework w as benchmarked against the QUADAS-2 tool [80], achieving a 94% agreement (Cohen’s κ =0.85) with expert-reviewed TCGA studies.”
InfluentialHeerspink, H. J. L., Grams, M. E., Sang, Y., Ballew, S. H., Coresh, J., Surapaneni, A., de Pinho, N. A., Brunskill, N. J., Chang, A. R., Ciemins, E. L., et al. (2025) · Annals of Internal Medicine · doi:10.7326/annals-25-02117 · Cited by 26
Qin, H., Ding, Y., Ju, J., Qu, Z., & Peng, L. (2025) · Annals of Medicine · doi:10.1080/07853890.2025.2610079 · Cited by 23
“We used the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool to evaluate the risk of bias and applicability of the included studies [23].”
Identification of the intraparotid facial nerve on MRI: a systematic review and meta-analysis
Lee, M., Choi, Y., Jang, J., Shin, N., Jung, S. L., Ahn, K. J., & Kim, B. (2020) · European Radiology · doi:10.1007/s00330-020-07222-9 · Cited by 17
Bioimpedance as a measure of fluid status in critically ill patients: A systematic review
Madsen, J. M., Wichmann, S., Bestle, M. H., & Itenov, T. S. (2021) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13924 · Cited by 19
Kurokawa, R., Baba, A., Kurokawa, M., Capizzano, A., Hassan, O., Johnson, T., Ota, Y., Kim, J., Hagiwara, A., Moritani, T., et al. (2022) · American Journal of Neuroradiology · doi:10.3174/ajnr.a7406 · Cited by 20
Fomenko, A., Weibel, S., Moezi, H., Menger, K., Schmucker, C. M., Metzendorf, M., Motschall, E., Falcone, V., Huzly, D., Panning, M., et al. (2022) · Reviews in Medical Virology · doi:10.1002/rmv.2342 · Cited by 19
Shin, H., Kim, J. G., Jang, B.-H., Lim, T. H., Kim, W., Cho, Y., Choi, K.-S., Na, M. K., Ahn, C., & Lee, J. (2022) · Medicina · doi:10.3390/medicina58050614 · Cited by 20
Home-Based Perimetry for Glaucoma: Where Are We Now?
Daka, Q., Mustafa, R., Neziri, B., Virgili, G., & Azuara‐Blanco, A. (2022) · Journal of Glaucoma · doi:10.1097/ijg.0000000000002022 · Cited by 17
Byun, J., Yang, T., Sunwoo, J., Shin, W. C., Kwon, O., & Jung, K. (2022) · SLEEP · doi:10.1093/sleep/zsac150 · Cited by 17
Macêdo, J. V. D. L., Frías, I. A. M., Oliveira, M. D. L., Zanghelini, F., & Andrade, C. A. S. (2022) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-022-04485-6 · Cited by 17
Zeng, T., Ling, B., Hu, X., Wang, S., Qiao, W., Gao, L., Shen, Y., & Li, D. (2022) · Canadian Respiratory Journal · doi:10.1155/2022/7078652 · Cited by 17
Assessment and diagnosis of the acute hot joint: a systematic review and meta-analysis
Dey, M., Al-Attar, M., Peruffo, L. C. B., Coope, A., Zhao, S. S., Duffield, S. J., & Goodson, N. J. (2022) · Rheumatology · doi:10.1093/rheumatology/keac606 · Cited by 17
Biomarker Expression of Peri-Implantitis Lesions before and after Treatment: A Systematic Review
Moaven, H., Giacaman, A., Beltrán, V., Sam, Y. H., Betancur, D., Mainas, G., Tarjomani, S. A., Donos, N., & Sousa, V. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192114085 · Cited by 22
Ruan, D., & Sun, L. (2022) · Clinical Breast Cancer · doi:10.1016/j.clbc.2022.11.010 · Cited by 19
Schippers, E. E., Smid, W., Hoogsteder, L. M., Planting, C. H. M., & de Vogel, V. (2023) · Aggression and Violent Behavior · doi:10.1016/j.avb.2022.101813 · Cited by 20
Wu, Y., Levis, B., Daray, F. M., Ioannidis, J. P. A., Patten, S. B., Cuijpers, P. J., Ziegelstein, R. C., Gilbody, S. M., Fischer, F. H., Fan, S., et al. (2023) · Psychological Assessment · doi:10.1037/pas0001181 · Cited by 18
Khan, I. A., Boyd, B. O., Chen, A. F., Cortes-Penfield, N. W., Myers, T. G., Brown, T. S., Suh, G. A., McGwin, G., Ghanem, E. S., & Fillingham, Y. A. (2023) · JBJS Reviews · doi:10.2106/jbjs.rvw.22.00201 · Cited by 18
Role of Exendin-4 Functional Imaging in Diagnosis of Insulinoma: A Systematic Review
Sidrak, M. M. A., Feo, M. S. D., Corica, F., Gorica, J., Conte, M., Filippi, L., Evangelista, L., VINCENTIS, G. D., & Frantellizzi, V. (2023) · Life · doi:10.3390/life13040989 · Cited by 22
Feinberg, C., Mayes, K. D., Portman, E., Carr, C., & Mannix, R. (2023) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp-2023-331220 · Cited by 19
Montero, J. A., Riveros, B. P. P., Asfura, O. E. B., Jiménez, M. R., López‐Andrés, N., & Martín‐Calvo, N. (2023) · European Journal of Pediatrics · doi:10.1007/s00431-023-04978-2 · Cited by 17
Rovera, G., de Koster, E. J., Rufini, V., Zollino, M., Zagaria, L., Giammarile, F., Vidal‐Sicart, S., Olmos, R. A. V., & Collarino, A. (2023) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-023-06290-5 · Cited by 17
“…methodological quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies tool version 2 (QUADAS-2) [8] to grade the risk of bias and methodological applicability on four key domains: patient selection, index test, reference standard, and flow and…”
Park, S., & Kwon, Y. M. (2023) · Child Psychiatry & Human Development · doi:10.1007/s10578-023-01553-6 · Cited by 20
“Two reviewers independently assessed the quality of the selected studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [18].”
Tuohuti, A., Lin, Z., Cai, J., & Chen, X. (2023) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-023-08095-6 · Cited by 20
Sood, A. K., Kishan, A. U., Evans, C. P., Feng, F. Y.-C., Morgan, T. M., Murphy, D. G., Padhani, A. R., Pinto, P. A., van der Poel, H. G., Tilki, D., et al. (2023) · European Urology Oncology · doi:10.1016/j.euo.2023.06.002 · Cited by 17
Wang, Q., Wang, A., Wu, X., Hu, X., Bai, G., Fan, Y., Stal, P. I., & Brismar, T. B. (2023) · European Journal of Radiology · doi:10.1016/j.ejrad.2023.111015 · Cited by 18
Alghamdi, D. A., Kernohan, N., Li, C., & Nabi, G. (2023) · Cancers · doi:10.3390/cancers15164105 · Cited by 17
Lovett, G. C., Schulberg, J. D., Hamilton, A. L., Wilding, H., Kamm, M. A., & Wright, E. K. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2023.09.010 · Cited by 19
Zhang, Y., Diao, D., Zhang, H., & Gao, Y. (2023) · Nursing in Critical Care · doi:10.1111/nicc.12982 · Cited by 17
Ren, J., Lu, Q., Fei, X., Dong, Y., D’Onofrio, M., Sidhu, P. S., & Dietrich, C. F. (2023) · European Radiology · doi:10.1007/s00330-023-10371-2 · Cited by 17
“The risk of bias and concerns regarding applicability were separately evaluated [10].”
Chang, W., Liu, C., Huang, Y., Wu, J., Tsai, W.-W., Hung, K., Chen, I., & Feng, P.-H. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1282675 · Cited by 17
Meta-analysis of diagnostic accuracy of nucleic acid amplification tests for abdominal tuberculosis
Shen, Y., Fang, L., Ye, B., & Yu, G. (2023) · PLoS ONE · doi:10.1371/journal.pone.0289336 · Cited by 18
Mustafa, H. J., Javinani, A., Muralidharan, V., & Khalil, A. A. (2023) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2023.101246 · Cited by 18
Image-based AI diagnostic performance for fatty liver: a systematic review and meta-analysis
Zhao, Q., Lan, Y., Yin, X., & Wang, K. (2023) · BMC Medical Imaging · doi:10.1186/s12880-023-01172-6 · Cited by 19
Rohmah, I., Chen, Y., Lin, C., Tsao, N.-H., & Chiu, H. (2023) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2023.103606 · Cited by 18
Katzman, B. D., Alabousi, M., Islam, N., Zha, N., & Patlas, M. N. (2024) · Canadian Association of Radiologists Journal · doi:10.1177/08465371231220885 · Cited by 24
Santing, J. A. L., Hopman, J. H., Verheul, R. J., van der Naalt, J., van den Brand, C. L., & Jellema, K. (2024) · Injury · doi:10.1016/j.injury.2024.111313 · Cited by 17
Accuracy of point-of-care testing devices for haemoglobin in the operating room: meta-analysis
Ahn, H., Lenet, T., Gilbert, R. W. D., Mallick, R., Shaw, J. L. V., Fergusson, D. A., McIsaac, D. I., & Martel, G. (2024) · BJS Open · doi:10.1093/bjsopen/zrad148 · Cited by 20
Filipov, T., Teutsch, B., Szabó, A., Forintos, A., Ács, J., Váradi, A., Hegyi, P., Szarvas, T., Ács, N., Nyírády, P., et al. (2024) · Journal of Nephrology · doi:10.1007/s40620-023-01856-w · Cited by 22
“The risk of bias assessment was carried out independently by two authors (FT, AF) using the QUADAS-2 tool [18], which consists of two parts: concerns about bias and practical applicability.”
MethodLuu, M. N., Trinh, N. A., Tran, T. L. T., Dang, T. P., Hiyama, T., & Quach, D. T. (2024) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.16523 · Cited by 18
Russell, F. M., Harrison, N. E., Hobson, O., Montelauro, N., Vetter, C. J., Brenner, D., Kennedy, S. K., & Hunter, B. R. (2024) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2024.03.021 · Cited by 21
Diao, Y., Yu, X., Zhang, Q., & Chen, X. (2024) · Nursing in Critical Care · doi:10.1111/nicc.13064 · Cited by 17
Cao, L., He, B., Zhou, Y., Chen, T., Gao, Y., & Yao, B. (2024) · Medical Ultrasonography · doi:10.11152/mu-4355 · Cited by 17
Bečulić, H., Begagić, E., Džidić-Krivić, A., Pugonja, R., Softić, N., Bašić, B., Balogun, S. A., Nuhović, A., Softić, E., Ljevaković, A., et al. (2024) · Brain and Spine · doi:10.1016/j.bas.2024.102809 · Cited by 19
Pavone, M., Goglia, M., Taliento, C., Lecointre, L., Bizzarri, N., Fanfani, F., Fagotti, A., Scambia, G., Marescaux, J., Querleu, D., et al. (2024) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-2023-005252 · Cited by 18
McCoy, C. A., Coleman, H. G., McShane, C. M., McCluggage, W. G., Wylie, J., Quinn, D., & McMenamin, Ú. C. (2024) · PLoS ONE · doi:10.1371/journal.pone.0302252 · Cited by 22
Etemadifar, M., Norouzi, M., Alaei, S., Karimi, R., & Salari, M. (2024) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2024.105682 · Cited by 20
Park, S., & Kim, E. Y. (2024) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2024.104748 · Cited by 18
Wang, Q., Fang, Y., Tan, S.-Y., Li, Z., Zheng, R., Ren, Y., Jiang, Y., & Huang, X. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1397259 · Cited by 18
Deep learning for temporomandibular joint arthropathies: A systematic review and meta‐analysis
Rokhshad, R., Mohammad‐Rahimi, H., Sohrabniya, F., Jafari, B., Shobeiri, P., Tsolakis, I. A., Ourang, S. A., Sultan, A. S., Khawaja, S. N., Bavarian, R., et al. (2024) · Journal of Oral Rehabilitation · doi:10.1111/joor.13701 · Cited by 20
Huynh, D., Rubtsov, D., Basu, D., & Khaing, M. M. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13113030 · Cited by 17
Habibi, M. A., Alavi, S. A. N., Farsani, A. S., Nasab, M. M. M., Tajabadi, Z., & Kobets, A. J. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.05.103 · Cited by 17
Gurushanth, K., Sunny, S. P., Kuriakose, M. A., & Birur, P. N. (2024) · Oral Diseases · doi:10.1111/odi.15001 · Cited by 17
“Two reviewers independently evaluated the methodological quality of the included studies using Quality Assessment of Diagnostic Accuracy Studies-2; modified questionnaires (QUADAS-2) (Whiting, 2011 ).”
Jiménez‐Sánchez, A., Cunill, J. L. P., Limón-Mirón, M. L., López-Ladrón, A., Bofill, J. S., & García‐Luna, P. P. (2024) · Nutrients · doi:10.3390/nu16121824 · Cited by 17
Mäenpää, S. M., & Korja, M. (2024) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2024.105523 · Cited by 22
Artificial Intelligence in the Diagnosis of Onychomycosis—Literature Review
Bulińska, B., Mazur-Milecka, M., Sławińska, M., Rumiński, J., & Nowicki, R. J. (2024) · Journal of Fungi · doi:10.3390/jof10080534 · Cited by 18
Nicholson, B. D., Virdee, P. S., Aveyard, P. N., Price, S. J., Hobbs, R. F., Koshiaris, C., & Hamilton, W. (2024) · BMJ · doi:10.1136/bmj-2024-080199 · Cited by 22
Uparela-Reyes, M. J., Ordóñez-Cure, S., Moreno-Drada, J. A., Villegas-Trujillo, L. M., & Escobar-Vidarte, O. A. (2024) · Neurosurgery · doi:10.1227/neu.0000000000003273 · Cited by 17
Hajikarimloo, B., Habibi, M. A., Alvani, M. S., Meinagh, S. O., Kooshki, A., Afkhami-Ardakani, O., Rasouli, F., Tos, S. M., Tavanaei, R., Akhlaghpasand, M., et al. (2024) · Neurological Sciences · doi:10.1007/s10072-024-07879-w · Cited by 17
“The Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2), which evaluates the ROB of diagnostic accuracy studies, was utilized by two independent reviewers to assess the ROB of included studies [12].”
The role of deep learning in diagnostic imaging of spondyloarthropathies: a systematic review
Omar, M., Watad, ., McGonagle, D., Soffer, S., Glicksberg, B. S., Nadkarni, G. N., & Klang, E. (2024) · European Radiology · doi:10.1007/s00330-024-11261-x · Cited by 21
“To evaluate the quality and robustness of the methodologies in the included studies, the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool was used [31].”
Karamian, A., Farzaneh, H., Khoshnoodi, M., Maleki, N., Karamian, A., Stufflebeam, S. M., & Lucke-Wold, B. P. (2025) · Neurocritical Care · doi:10.1007/s12028-024-02189-7 · Cited by 21
“The risk of bias in included studies was assessed using the revised tool for quality assessment of studies of diagnostic accuracy included in the systematic review [23].”
van der Waerden, R. G. A., Volleberg, R. H. J. A., Luttikholt, T. J., Cancian, P., van der Zande, J. L., Stone, G. W., Holm, N. R., Kedhi, E., Escaned, J., Pellegrini, D., et al. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf005 · Cited by 19
Lord, S. J., Horvath, A. R., Sandberg, S., Monaghan, P. J., Cobbaert, C. M., Reim, M., Tolios, A., Mueller, R., & Bossuyt, P. M. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453148 · Cited by 18
“Measures such as sensitivity and specificity are firmly established as the primary measures of clinical performance for screening and diagnostic tests; with published guidance for study design, reporting, and appraisal [7–9].”
Self-citationIncreased risk of dementia in Type 1 diabetes: A systematic review with meta-analysis
Li, L., Wong, D. K., Fisher, C. A., CONN, J. J., WRAIGHT, P. R., Davies, A., Barson, E., & Pike, K. E. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112043 · Cited by 22
Salimi, M., Vadipour, P., Houshi, S., Yazdanpanah, F., & Seifi, S. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-04892-1 · Cited by 19
Komakech, K., Semugenze, D., Joloba, M. L., Cobelens, F. G. J., & Ssengooba, W. (2025) · EClinicalMedicine · doi:10.1016/j.eclinm.2025.103257 · Cited by 17
“51 The tool consists of four domains (i.e., patient selection, index test, reference standard and fl ow & timing) from which risk of bias and applicability concerns were assessed using signaling questions.”
Manole, L. M., Ghiga, G., Iftinchi, O., Boca, L. O., Donos, M. A., Țarcă, E., Nistor, I., Revenco, N., Margasoiu, I., & Trandafir, L. M. (2025) · Diagnostics · doi:10.3390/diagnostics15121505 · Cited by 19
Hao, J., Nalley, A., Yeung, A. W. K., Tanaka, R., Ai, Q. Y. H., Lam, W. Y. H., Shan, Z., Leung, Y. Y., AlHadidi, A., Bornstein, M. M., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01818-5 · Cited by 26
“The assessment of the risk of bias in annotations focused on the reliabilityofthereferencestandard(i.e.,groundtruthannotations),whichis oneofthefourdomainsproposedbytheRevisedToolfortheQuality AssessmentofDiagnosticAccuracyStudies(QUADAS-2),atoolwidely usedindiagnosticimagingstudies 67 .”
Diagnostic accuracy of H b A 1c in diabetes between E astern and W estern
Yan, S., Liu, S., Zhao, Y., Zhang, W., Sun, X., Li, J., Jiang, F.-L., Ju, J., Lang, N., Zhang, Y., et al. (2013) · European Journal of Clinical Investigation · doi:10.1111/eci.12098 · Cited by 18
Reynders, R. M., Ladu, L., Ronchi, L., Girolamo, N. D., de Lange, J., Roberts, N. W., & Plüddemann, A. (2015) · Systematic Reviews · doi:10.1186/s13643-015-0014-6 · Cited by 19
Lloyd, A., Pasupuleti, V., Thota, P., Pant, C., Rolston, D. D. K., Hernández, A. V., Benites-Zapata, V. A., Fraser, T. G., Donskey, C. J., & Deshpande, A. (2015) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2015.02.007 · Cited by 17
Blood metal ion levels are not a useful test for adverse reactions to metal debris
Pahuta, M. A., Smolders, J. M. H., van Susante, J. L., Peck, J., Kim, P. R., & Beaulé, P. E. (2016) · Bone and Joint Research · doi:10.1302/2046-3758.59.bjr-2016-0027.r1 · Cited by 17
Li, Z., Zhou, Q., Li, Y., Yan, S., Fu, J., Huang, X., & Shen, L. (2017) · Oncotarget · doi:10.18632/oncotarget.14922 · Cited by 17
Duque, I. D. E. (2017) · Universitas Médica · doi:10.11144/javeriana.umed58-2.obes · Cited by 24
Suh, C. H., Shinagare, A. B., Westenfield, A. M., Ramaiya, N. H., den Abbeele, A. D. V., & Kim, K. W. (2017) · Clinical Radiology · doi:10.1016/j.crad.2017.08.004 · Cited by 17
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.