QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 8,101–8,200 of 14,770
Canevelli, M., Bacigalupo, I., Gervasi, G., Lacorte, E., Massari, M., Mayer, F., Vanacore, N., & Cesari, M. (2019) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2019.00282 · Cited by 10
“, 2014) can be a useful tool to improve consistency and transparency, and the application of the QUADAS 2 checklist (Whiting et al., 2011) can allow the identification of potential methodological biases, thus enabling a more effective assessment of candidate diagnostic tests.”
Jang, M., Kim, B., & Lee, Y. K. (2019) · Annals of Laboratory Medicine · doi:10.3343/alm.2020.40.3.245 · Cited by 12
de Oliveira, A. L. G., Fraga, V. G., Sernizon-Guimarães, N., Cardoso, M. S., Viana, A. G., Bueno, L. L., Bartholomeu, D. C., Menezes, C. A. D. S., & Fujiwara, R. T. (2020) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2019.12.011 · Cited by 13
A Systematic Review of Screening Tests for Chronic Kidney Disease: An Accuracy Analysis
Yousefi, M., Keshvari-Shad, F., Hajebrahimi, S., Pes, M. P. L., Ahari, A. M., Nouri, M., & Seyednejad, F. (2020) · Galen Medical Journal · doi:10.31661/gmj.v9i.1573 · Cited by 12
Ahmadzada, S., Vasan, K., Sritharan, N., Singh, N. P., Smith, M. C., Hull, I., & Riffat, F. (2020) · Head & Neck · doi:10.1002/hed.26428 · Cited by 10
dos Santos, E. S., Normando, A. G. C., Scarini, J. F., Crescencio, L. R., de Lima‐Souza, R. A., Mariano, F. V., & Leme, A. F. P. (2021) · Oral and Maxillofacial Surgery · doi:10.1007/s10006-021-00952-0 · Cited by 11
Kim, K., & Kim, S. (2021) · Clinical Imaging · doi:10.1016/j.clinimag.2021.06.015 · Cited by 12
Getachew, E., Adebeta, T., Gebrie, D., Charlie, L., Said, B., Assefa, D. G., Wanjiru, C. L., Zeleke, E. D., Tesfahunei, H. A., Abebe, M., et al. (2021) · Journal of Clinical Tuberculosis and Other Mycobacterial Diseases · doi:10.1016/j.jctube.2021.100254 · Cited by 10
Zhao, F., Huo, X., Wang, M., Liu, Z., Zhao, Y. D., Ren, D., Xie, Q., Liu, Z., Li, Z., Du, F., et al. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.731148 · Cited by 10
Identifying patient safety competences among anesthesiology residents: systematic review
Pereira, F. S. H., Garcia, D. B., & Ribeiro, E. R. (2022) · Brazilian Journal of Anesthesiology (English Edition) · doi:10.1016/j.bjane.2021.06.029 · Cited by 10
Yan, Z., Wang, H., Zheng, W., & Hu, Z.-D. (2022) · Journal of Tropical Medicine · doi:10.1155/2022/4348063 · Cited by 10
Tsai, Y.-T., Hung, K., Shih, Y., Lim, S.-W., Yang, C.-C., Kuo, Y., Chen, J.-H., & Ko, C. (2022) · Diagnostics · doi:10.3390/diagnostics12030630 · Cited by 10
Abdollahifard, S., Farrokhi, A., & Mowla, A. (2022) · Journal of NeuroInterventional Surgery · doi:10.1136/jnis-2022-019627 · Cited by 10
Shin, J., Lee, S., Yoon, J. K., & Roh, Y. H. (2023) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28716 · Cited by 11
Dahabreh, I. J., Chung, M., Kitsios, G. D., Terasawa, T., Raman, G., Tatsioni, A., Tobar, A., Lau, J., Trikalinos, T. A., & Schmid, C. H. (2013) · Research Synthesis Methods · doi:10.1002/jrsm.1083 · Cited by 13
Lee, S., Sahasrabuddhe, V. V., Mendoza-Cervantes, D., Zhao, R., & Duggan, M. A. (2017) · International Journal of Gynecological Pathology · doi:10.1097/pgp.0000000000000406 · Cited by 10
van de Maat, J., Nieboer, D., Thompson, M. J., Lakhanpaul, M., Moll, H. A., & Oostenbrink, R. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217570 · Cited by 12
Shah, M., Hanrahan, C. F., Wang, Z. Y., Steingart, K. R., Lawn, S. D., Denkinger, C. M., & Dendukuri, N. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011420 · Cited by 10
Gemme, S. R., & Tubbs, R. J. (2014) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2014.10.029 · Cited by 10
Anderson, J., Bourne, D. S., Peterson, K., & Mackey, K. (2019) · Research Square · doi:10.21203/rs.2.13814/v1 · Cited by 10
Fage, B. A., Seitz, D. P., Gill, S. S., Herrmann, N., Smailagic, N., Chan, C. C., & Nikolaou, V. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010860 · Cited by 8
Liu, J. L., Walsh, T., Kerr, A. R., Lingen, M. W., Brocklehurst, P. R., Ogden, G. R., Warnakulasuriya, S., & Scully, C. M. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010276 · Cited by 13
“The revised QUADAS tool, QUADAS-2 (Whiting 2011), will be used to assess the quality of the primary diagnostic studies over four key domains: patient selection, index test, reference standard and flow and timing of participants through the study.”
Toljan, K., Amin, M., & Ontaneda, D. (2025) · Clinical Radiology · doi:10.1016/j.crad.2025.106984 · Cited by 9
Next Generation Sequencing Claims in Precision Medicine: Questions a Formulary Committee Should Ask
Langley, P. C. (2016) · INNOVATIONS in pharmacy · doi:10.24926/iip.v7i4.473 · Cited by 9
Gao, H., Shen, Y., Feng, Z., Cai, Y., Yang, J., Zhu, Y., & Peng, Q. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.965357 · Cited by 9
Prevalence of subclinical lung cancer detected at autopsy: a systematic review
Bonney, A., Togawa, K., Ng, M. S. W., Christie, M., Fong, K. M., Marshall, H., See, K., Patrick, C. J., Steinfort, D., & Manser, R. L. (2023) · BMC Cancer · doi:10.1186/s12885-023-11224-3 · Cited by 9
Pereiro, J. E., Alagna, R., Saluzzo, F., González-Moreno, J., Heinrich, N., Sánchez‐Montalvá, A., & Cirillo, D. M. (2023) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiad482 · Cited by 8
Jones, C. H. D., Jakubowski, B. E., Stevens, R., Roberts, N. W., McManus, R. J., & Tucker, K. L. (2024) · Pregnancy Hypertension · doi:10.1016/j.preghy.2024.01.133 · Cited by 10
Clinical and Instrumental Swallowing Assessments for Dysphagia
Haas, R., & Bailey, S. (2024) · Canadian Journal of Health Technologies · doi:10.51731/cjht.2024.833 · Cited by 9
Deng, L., Shuai, P., Liu, Y.-R., Yong, T., Liu, Y.-P., Li, H., & Zheng, X.-X. (2024) · Osteoporosis International · doi:10.1007/s00198-024-07136-y · Cited by 9
Posarelli, M., Passaro, M. L., Avolio, F. C., Costagliola, C., Semeraro, F., & Romano, V. (2024) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2024.06.001 · Cited by 9
A systematic review of the predictive value of radiomics for nasopharyngeal carcinoma prognosis
Deng, Q., Hou, Y., Zhang, X., & Zan, H. (2024) · Medicine · doi:10.1097/md.0000000000039302 · Cited by 10
Granieri, S., Altomare, M., Bonomi, A. M., Panagini, G., Frassini, S., Cioffi, S. P. B., Basta, G., Spota, A., Sammartano, F., Bini, R., et al. (2024) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-024-02667-9 · Cited by 10
Li, X., Yuan, F., Li, X., & Li, X. (2024) · Academic Radiology · doi:10.1016/j.acra.2024.08.055 · Cited by 12
Barghi, M., Heidari, Z., Haghighatdoost, F., Feizi, A., & Hashemipour, M. (2024) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2024.10.004 · Cited by 10
Zare, M. E., Kansestani, A. N., Wu, X., Zhou, L., Lu, J., HUANG, J. C., Wang, Y., Ma, Y., Gao, Y., & Zhang, J. (2024) · iScience · doi:10.1016/j.isci.2024.111211 · Cited by 10
Yang, L., He, L., Hu, H., Li, W., Yang, Y., Zhao, H., Wang, J., & Yu, X. (2024) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-024-07981-2 · Cited by 9
“The risk of bias was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) recommended by the Cochrane Collaboration Network [8].”
MethodThe electronic nose in lung cancer diagnostics: a systematic review and meta-analysis
Steenhuis, E. G. M., Asmara, O. D., Kort, S., Papenhuijzen, M. H. G., Veeger, N. J. G. M., van den Heuvel, M. M., & van Geffen, W. H. (2024) · ERJ Open Research · doi:10.1183/23120541.00723-2024 · Cited by 12
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [24] was used to assess the risk of bias and applicability.”
Qady, A. A., Aldhaleei, W. A., Salih, M., Ali, M., Menakuru, S. R., Nayar, K. D., Wang, Z., Stancampiano, F. F., Harris, D. M., & Bi, Y. (2024) · Clinical and Translational Gastroenterology · doi:10.14309/ctg.0000000000000792 · Cited by 11
Mahmoud, O. K., Petri, F., Zein, S. E., Fida, M., Diehn, F. E., Verdoorn, J. T., Schuetz, A. N., Murad, M. H., Nassr, A. N., & Berbari, E. F. (2024) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000003314 · Cited by 9
“This instrument comprises four essential domains for evaluating risks of bias (quality) and three key domains for assessing concerns related to applicability [32].”
GRADE-based procalcitonin guideline for emergency departments
Lee, C., Porta, L., Liu, Y., Chen, P.-T., Pan, H.-H., Lee, Y., Chen, K., Lee, C., Tsai, W., How, C., et al. (2024) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2024.11.093 · Cited by 10
Vieira, L. H. P., Clemente, F. M., Silva, R., Vargas-Villafuerte, K. R., & Carpes, F. P. (2024) · Sensors · doi:10.3390/s24247912 · Cited by 9
“For studies assessing accuracy aspects, the QUADAS-2 tool was adopted [54].”
Wu, Q., Tu, X., Jiang, J., Ye, J., Lin, T., Liu, Z., Yang, L., Qiu, S., Tang, B., Bao, Y., et al. (2024) · Urologic Oncology Seminars and Original Investigations · doi:10.1016/j.urolonc.2024.11.023 · Cited by 10
Tang, N., Pan, S., Zhang, Q., Zhou, J., Zuo, Z., Jiang, R., & Sheng, J. (2025) · Abdominal Radiology · doi:10.1007/s00261-024-04713-x · Cited by 9
Sun, Y., Hu, D., Yu, M., Liang, S.-B., Zheng, Y., Wang, X., & Tong, G. (2025) · Clinical Epidemiology · doi:10.2147/clep.s501445 · Cited by 12
Xiong, Y., Gao, Y., Qi, Y., Zhi, Y., Xu, J., Wang, K., Yang, Q., Wang, C., Zhao, M., & Meng, X. (2025) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-025-02869-0 · Cited by 11
“Quality evaluation of the included studies was performed using QUA-DAS-2 [7].”
Stool Antigen Test for Helicobacter Pylori Infection in Adults
Luz, M. S., de Castro, C. T., Lemos, F. F. B., Rocha, G. R., Santos, G. L. C., Pinheiro, S. L. R., Silva, L. G. D. O., Calmon, M. S., Oliveira, M. V., Teixeira, K. N., et al. (2024) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0000000000002102 · Cited by 9
Systematic review and meta-analysis: diagnostic accuracy of exosomes in pancreatic cancer
Xu, X., Long, C., Li, M., Shen, C., Ye, Q., Li, Y., Li, H., Cao, X., & Ma, J. (2025) · World Journal of Surgical Oncology · doi:10.1186/s12957-025-03666-9 · Cited by 12
Melnik, T., Sinval, J., de Pinho, V. D., Júnior, J. A. S. H., Oliveira, M. D. S., & Lopes, F. M. (2025) · Healthcare · doi:10.3390/healthcare13040431 · Cited by 9
Lohani, D. C., Chawla, V., & Rana, B. (2025) · Neuroscience · doi:10.1016/j.neuroscience.2025.02.019 · Cited by 9
Shirmard, F. O., Pourfaraji, S. M., Saeedian, B., Bagheri, T., Ismaiel, A., Matsumoto, S., & Babajani, N. (2025) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000002952 · Cited by 9
Tay, J. L., Ang, Y. L., Tam, W., & Sim, K. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-084463 · Cited by 12
“35 The tool consisted of seven questions and evaluated the studies on their recruitment process, usage of index test and reference standard, with indicators (1) low, (2) high or (3) unclear.”
Evaluation of biological therapies in autoimmune hepatitis: A case-based systematic review
Eldew, H., & Soldera, J. (2025) · World Journal of Gastrointestinal Pathophysiology · doi:10.4291/wjgp.v16.i1.101481 · Cited by 12
“The risk of bias in randomized controlled trials (RCTs) was assessed by the QUADAS-2 in observational studies[20], using the Cochrane Bias Assessment tool Robvis[21].”
Martuszewski, A., Paluszkiewicz, P., Poręba, R., & Gać, P. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14062066 · Cited by 14
“Diagnostic studies were evaluated with QUADAS-2 [14], focusing on patient selection, index tests, reference standards, and timing.”
Molecular assays for the diagnosis of sepsis in neonates: a diagnostic test accuracy review
Dierikx, T. H., Visser, D. H., de Meij, T. G. J., Versalovic, J. A., Leeflang, M., Cooper, C., & Pammi, M. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011926.pub3 · Cited by 23
Self-citationZhou, C., Kou, Y., Zhou, W., Zhao, W., Fan, Z., Jiao, Y., Zhai, Y., Liu, J., Guo, S., Ji, P., et al. (2025) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8565 · Cited by 10
Taha, M., Shafique, U., Rashid, W., Taha, H., Awan, M., Ayyub, A., Ahmad, S., & Alsadoun, L. (2025) · Cureus · doi:10.7759/cureus.81853 · Cited by 13
“In addition, risk-of-bias assessment tools such as AMSTAR 2 [10], ROB 2 [11], QUADAS-2 [12], and the Newcastle-Ottawa Scale [13] were applied to assess study quality and reliability.”
Zheng, X., Li, M., Guo, Z., Tian, Z., Zhang, J., Mao, Y.-Y., Zhao, P., Li, Z.-Y., & Wan, X.-H. (2025) · BMC Ophthalmology · doi:10.1186/s12886-025-04066-z · Cited by 9
“The study quality was assessed using a modified check-list from the QUADAS-2 tool, which evaluated four domains: patient selection, indicator testing, reference criteria, and process and timing [16].”
Chen, Y., He, Y. L., Dahl, V. N., Yu, K., Zhang, Y., Guan, C.-P., & Wang, M. (2025) · PLOS Global Public Health · doi:10.1371/journal.pgph.0004465 · Cited by 9
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used for assessment of bias risk and applicability concerns [20].”
Moro, F., Ciancia, M., Maria, S., Baldassari, G., Tran, H. E., Carcagnì, A., Fagotti, A., & Testa, A. C. (2025) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.15146 · Cited by 11
“These criteria are based on the revised and extended QUADAS-2 12 and QUADAS-C 13 guidelines and include four domains: patient selection, index test, reference standard, and flow and timing, all in relation to the risk of bias.”
Diagnostic pitfalls in [68Ga]Ga-DOTATATE PET/CT imaging: a systematic review
Abdlkadir, A. S., Al-Adhami, D. A., Alrammahi, M., Badarneh, M., Alyasjeen, S. F., Busaidi, K. A., Khalaf, A. A., Al-Alawi, H. M., Alalawi, H., & Al‐Ibraheem, A. (2025) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001987 · Cited by 9
Ingold, G. C., da Fonseca, J. M., Zloić, S. K., Moreira, S. V., Marole, K. K., Finnegan, E. A., Yoshikawa, M. H., Daugėlaitė, S., Silva, T. X. S. E., & Ratti, M. A. S. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-04981-1 · Cited by 10
“Each domain was rated as “high,” “low,” or “some concerns” [41].”
Chen, X., Huang, Y., Jessney, B., Sangha, J., Gu, S. Z., Schönlieb, C., Bennett, M. R., & Roberts, M. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf053 · Cited by 14
Xu, M., Li, X., Wang, L., Yu, J., Li, D., Chi, X., & Wei, F. (2025) · Journal of Dentistry · doi:10.1016/j.jdent.2025.105842 · Cited by 9
Salimi, M., Hajikarimloo, B., Vadipour, P., Abdolizadeh, A., Fayedeh, F., & Seifi, S. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-05056-x · Cited by 9
“The QUADAS-2 tool [23] was used to evaluate the risk of bias and applicability concerns.”
Consensus guideline for the management of colorectal cancer with peritoneal metastases
Schultz, K. S., Bansal, V. V., Wach, M. M., Bhutiani, N., Godley, F. A., Wang, J., Waheed, M. T., Buchheit, J. T., Papai, E., Campbell, S. E., et al. (2025) · Cancer · doi:10.1002/cncr.35869 · Cited by 16
Colman, K., Schyvens, A.-M., Volder, I. D., Verbraecken, J. A., Pijpers, A., Viaene, M. K., Oertel, W. H., Dijkstra, F., & Crosiers, D. (2025) · npj Parkinson's Disease · doi:10.1038/s41531-025-01032-w · Cited by 12
Gou, B., Zhang, C., Song, Z., Huang, Z., & Lu, S. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120469 · Cited by 9
Osawa, T., Nakayama, N., Ishizu, T., Kondo, T., Nakashima, T., Yamamoto, T., Hanada, H., Hashiba, K., Kirigaya, J., Hosoya, Y., et al. (2025) · Circulation Reports · doi:10.1253/circrep.cr-25-0105 · Cited by 9
“The same 2 authors independently evaluated the methodological quality of included studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, 20 which assesses 4 domains: patient selection, index test, reference standard, and flow and timing.”
Becerra, C. A. G., Gallardo, M. I. A., Garcia, J. E. J., Soltero-Molinar, V., Rivera-Rocha, M. I., Parra-Camaño, L. F., Garcia-Becerra, N., & García-Gutiérrez, C. M. (2025) · Prostate Cancer and Prostatic Diseases · doi:10.1038/s41391-025-00999-0 · Cited by 9
“This phase of SR took place simultaneously with the data extraction process and used the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [31].”
Dantas, E. L. D. S., Stelzer, F. G., Bernardo, W. M., & Éckeli, Á. L. (2025) · InterAmerican Journal of Medicine and Health · doi:10.1016/j.smrv.2025.102139 · Cited by 12
Hillier, B., Deeks, J. J., Alderman, J. E., Kale, A. U., Macdonald, T., Baldwin, S. W., Scandrett, K., Agarwal, R., Richter, A. G., & Davenport, C. F. (2025) · BMJ · doi:10.1136/bmj-2025-085547 · Cited by 13
“27 We applied the QUADAS-2 tool to all obtained CSRs and to any LSRs that reported accuracy metrics such as sensitivity and specificity.”
Self-citationAI-driven assessment of over-scanning in chest CT: A systematic review and meta-analysis
Bani-Ahmad, M., England, A., McLaughlin, L., Alshipli, M., Alzyoud, K. S., Hadi, Y. H., & McEntee, M. F. (2025) · European Journal of Radiology Open · doi:10.1016/j.ejro.2025.100674 · Cited by 9
“The methodological quality of each included study was rigorously evaluated using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tools [25,26].”
Akgül, B., Tozsin, A., Aydın, A., Tokas, T., Otero, J., Ortner, G., Netsch, C., Herrmann, T. R. W., Rassweiler, J. J., Ahmed, K., et al. (2025) · World Journal of Urology · doi:10.1007/s00345-025-05884-y · Cited by 9
Yeh, J., Huang, C., Lee, C., Chen, Y.-J., Huang, S.-L., Wang, W., Tu, Y., Chiu, T., Chiang, C., Chen, C., et al. (2025) · Annals of Internal Medicine · doi:10.7326/annals-24-02142 · Cited by 9
Instrument-Based Screening for the Detection of Amblyopia and Amblyopia Risk Factors
Oatts, J. T., Collins, M. E., Cavuoto, K. M., Nallasamy, S., Prakalapakorn, S. G., Trivedi, R. H., Pineles, S. L., & Chang, M. Y. (2025) · Ophthalmology · doi:10.1016/j.ophtha.2025.07.007 · Cited by 9
Wang, Z., Shi, H., Wang, Q., Huang, Y., Feng, M., Lin, Y., Dong, B., Li, J., Deng, X., Fu, S., et al. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.08.035 · Cited by 9
Efstathiou, A., Charitaki, E., Triantopoulou, C., & Delis, S. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14186501 · Cited by 9
Selvaraj, C., Cho, W. C. S., Kulanthaivel, L., Alothaim, A. S., Vijayakumar, R., Jayaprakashvel, M., & Desai, D. (2025) · 3 Biotech · doi:10.1007/s13205-025-04518-9 · Cited by 12
“For diagnostic accuracy studies, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was applied (Whiting et al. 2011), evaluating risk of bias across four key domains: patient selection, index test, reference standard, and flow/timing.”
Serino, S., Stramba-Badiale, C., Magni, G., Castegnaro, A., Riva, G., & Tuena, C. (2025) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2025.106379 · Cited by 11
“Overall study quality was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-Comparative (QUADAS-2) framework (Whiting et al., 2011).”
Wang, T.-W., Luo, W.-T., Tu, Y., Chou, Y.-B., & Wu, Y.-T. (2025) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2025.09.045 · Cited by 10
How accurate is AI in detecting marginal jaw bone loss? A systematic review and meta-analysis
Chiang, H., Jonzén, K., Wu, W., Öhberg, F., Garoff, M., Lövgren, A., & Lundberg, P. (2025) · Journal of Dentistry · doi:10.1016/j.jdent.2025.106151 · Cited by 9
García‐Hermoso, A., Sepulveda, R. A. Y., Hormazábal‐Aguayo, I., Muñoz‐Pardeza, J., Martínez‐Vizcaíno, V., Almonacid, J. G. H., & Ezzatvar, Y. (2025) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.70091 · Cited by 11
Subjective versus objective cognition during menopause: A systematic review and meta-analysis
Furey, R. T., Thomas, E. H. X., Kulkarni, J., & Gurvich, C. (2025) · Journal of the International Neuropsychological Society · doi:10.1017/s1355617725101306 · Cited by 11
“The risk of bias and applicability concern for each study was evaluated using a modified QUADAS-2 form (Whiting, 2011).”
Histological analysis in the diagnosis of periprosthetic joint infection of the hip and knee
Sigmund, I. K., Bue, M., Jensen, L. K., McNally, M., Parvizi, J., & Sabater-Martos, M. (2025) · The Bone & Joint Journal · doi:10.1302/0301-620x.107b11.bjj-2025-0289.r1 · Cited by 9
Dashti, M., Khosraviani, F., Ghadimi, N., Baghaei, K., Esmaeili, S., Entezar-e-Ghaem, M., Khurshid, Z., & Osathanon, T. (2025) · BMC Oral Health · doi:10.1186/s12903-025-07254-x · Cited by 11
Wang, T., Luo, W.-T., Tu, Y., Chou, Y.-B., & Wu, Y. (2025) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2025.11.012 · Cited by 14
Mohammad‐Rahimi, H., Ourang, S. A., Nosrat, A., Spin‐Neto, R., & Pauwels, R. (2026) · International Endodontic Journal · doi:10.1111/iej.70092 · Cited by 9
Felicetti, F., Lamonaca, F., Carnì, D. L., & Costanzo, S. (2026) · Sensors · doi:10.3390/s26031039 · Cited by 13
“…specific methodological adaptations justified by its exploratory and metrological scope, it was not prospectively registered (e.g., in PROSPERO [32]), and no formal risk-of-bias assessment, reporting-bias assessment, or certainty-of-evidence evaluation (e.g., QUADAS-2, GRADE [33,34]) was performed.”
Davenport, C. F., Rutjes, A. W., Mallett, S., Tomlinson, E., Yang, B., Holmes, J., Westwood, M. E., Takwoingi, Y., Reitsma, J. B., Hyde, C., et al. (2026) · Annals of Internal Medicine · doi:10.7326/annals-25-04943 · Cited by 11
Self-citationMathew, J. L. (2026) · Indian Pediatrics · doi:10.1007/s13312-026-00347-y · Cited by 9
“The Cochrane RoB2 tool [19] was used for RCTs, the NIH tool for observational studies [20], and the QUADAS2 tool [21] for diagnostic test accuracy studies.”
Roeke, T., van Bommel, A. C. M., Gaillard-Hemmink, M. P., Hartgrink, H. H., Mesker, W. E., & Tollenaar, R. A. �. �. (2014) · Breast Cancer Research and Treatment · doi:10.1007/s10549-014-3074-8 · Cited by 9
Fu, J., Li, Y., Li, N., & Li, Z. (2018) · Cancer Management and Research · doi:10.2147/cmar.s176494 · Cited by 9
“9 Each domain item is further broken down into several subitems designated as low risk, high risk, or unclear risk according to the study.”
Kontsevaya, I., Werngren, J., Holicka, Y., Klaos, K., Tran, A., & Nikolayevskyy, V. (2019) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-019-03723-8 · Cited by 9
Wang, Z., Dai, Z.-W., Dong, Y., Wang, H., Yuan, F., Wang, B., & Ye, D. (2020) · JCR Journal of Clinical Rheumatology · doi:10.1097/rhu.0000000000001316 · Cited by 9
Brief, Performance-Based Cognitive Screening in Youth Aged 12–25: A Systematic Review
Bryce, S., Bowden, S. C., Wood, S. J., & Allott, K. (2021) · Journal of the International Neuropsychological Society · doi:10.1017/s1355617720001241 · Cited by 10
Alcázar, J. L., Carazo, P., Pegenaute, L., Gurrea, E., Campos, I., Neri, M., Pascual, M. A., & Guerriero, S. (2021) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-1408-2292 · Cited by 12
Poly, T. N., Islam, M. M., Li, Y., Alsinglawi, B. S., Hsu, M., Jian, W. S., & Yang, H. (2021) · JMIR Medical Informatics · doi:10.2196/21394 · Cited by 9
Value of preoperative staging of endometrial carcinoma with contrast-enhanced ultrasonography
Tong, X., Wu, X., & Zhang, Q. (2021) · Medicine · doi:10.1097/md.0000000000025434 · Cited by 9
Utility of Routine Laboratory Biomarkers to Detect COVID-19: A Systematic Review and Meta-Analysis
Suklan, J., Cheaveau, J., Hill, S., Urwin, S., Green, K., Winter, A., Hicks, T., Boath, A., Kernohan, A., Price, D., et al. (2021) · Viruses · doi:10.3390/v13050803 · Cited by 10
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.