Diagnostic Accuracy of Point-of-Care Tests for Detecting Albuminuria: A Systematic Review and Meta-analysis
The DOI matches its Crossref record, with a small difference in title or year; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Background Experts recommend screening for albuminuria in patients at risk for kidney disease. Purpose To systematically review evidence about the diagnostic accuracy of point-of-care (POC) tests for detecting albuminuria in individuals for whom guidelines recommend such detection. Data sources Cochrane Library, EMBASE, Medion database, MEDLINE, and Science Citation Index from 1963 through 5 December 2013; hand searches of other relevant journals; and reference lists. Study selection Cross-sectional studies, published in any language, that compared the accuracy of machine-read POC tests of urinary albumin-creatinine ratio with that of laboratory measurement. Data extraction Two independent reviewers extracted study data and assessed study quality using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool. Data synthesis Sixteen studies (n = 3356 patients) that evaluated semiquantitative or quantitative POC tests and used random urine samples collected in primary or secondary ambulatory care settings met inclusion criteria. Pooling results from a bivariate random-effects model gave sensitivity and specificity estimates of 76% (95% CI, 63% to 86%) and 93% (CI, 84% to 97%), respectively, for the semiquantitative test. Sensitivity and specificity estimates for the quantitative test were 96% (CI, 78% to 99%) and 98% (CI, 93% to 99%), respectively. The negative likelihood ratios for the semiquantitative and quantitative tests were 0.26 (CI, 0.16 to 0.40) and 0.04…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Clinical operators have a lower sensitivity but better specificity than laboratory technologists (500)”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [500]
In the citing paper
“Screening using two tests with either being positive interpreted as a positive (leading to subsequent quantitative testing) increases the sensitivity to 97% but reduces the specificity to 83% (500,501).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [500]
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
(2013) · Kidney International Supplements · doi:10.1038/kisup.2012.73 · Cited by 3,206
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910 · cited 1×
“We explored publication bias by using a regression of the log of the diagnostic odds ratio against the inverse of the square root of the effective sample size, weighted by effective sample size (29).”
MethodFox, C. S., Matsushita, K., Woodward, M., Bilo, H. J., Chalmers, J., Heerspink, H. J. L., Lee, B. J., Perkins, R. M., Rossing, P., Sairenchi, T., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61350-6 · Cited by 1,401
van der Velde, M., the Chronic Kidney Disease Prognosis Consortium, Matsushita, K., Coresh, J., Astor, B. C., Woodward, M., Levey, A. S., de Jong, P. E., & Gansevoort, R. T. (2011) · Kidney International · doi:10.1038/ki.2010.536 · Cited by 1,082
Gansevoort, R. T., Matsushita, K., van der Velde, M., Astor, B. C., Woodward, M., Levey, A. S., de Jong, P. E., & Coresh, J. (2011) · Kidney International · doi:10.1038/ki.2010.531 · Cited by 883
Research works printed but not linked: 5
- Knudsen ST, 2012, Dan Med J, 59, A4502
- Le Floch JP, 2001, Diabetes Metab, 27, 36
- Parsons M, 1999, Clin Nephrol, 51, 220
- 10.1002/(SICI)1098-2825(1998)12:5<280::AID-JCLA5>3.0.CO;2-A · doi:10.1002/(sici)1098-2825(1998)12:5<280::aid-jcla5>3.0.co;2-a
- Poulsen PL, 1992, Diabete Metab, 18, 395
Cited by
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Self-citationWebster, A. C., Nagler, E. V., Morton, R. L., & Masson, P. (2017) · The Lancet · doi:10.1016/s0140-6736(16)32064-5 · Cited by 3,842
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Metadata
- Authors
- McTaggart, M. P., Newall, R. G., Hirst, J. A., Bankhead, C. R., Lamb, E. J., Roberts, N. W., & Price, C. P.
- Affiliations
- East Kent Hospitals University NHS Foundation Trust (GB)
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2014-04-15
- Volume
- 160
- Issue
- 8
- Pages
- 550-557
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2016924560
- Semantic Scholar
- ec5af8a2770f8e7ade8c1406879482d328b1b53b
- Cited by
- 39
- References
- 52
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 7 · 2023: 4 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 3 · 2015: 2
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
- Keywords
- albuminuria, point-of-care testing, urinary albumin-creatinine ratio, diagnostic accuracy, sensitivity and specificity, kidney disease screening, chronic kidney disease, negative likelihood ratio, outpatient care
- MeSH terms
- Albuminuria, Humans, Quality Assurance, Health Care, Sensitivity and Specificity, Likelihood Functions, Point-of-Care Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Point-of-Care Tests for Detecting Albuminuria: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.7326/m13-2331
- The paper
- McTaggart, M. P., Newall, R. G., Hirst, J. A., Bankhead, C. R., Lamb, E. J., Roberts, N. W., & Price, C. P. (2014). Diagnostic Accuracy of Point-of-Care Tests for Detecting Albuminuria: A Systematic Review and Meta-analysis. Annals of Internal Medicine. https://doi.org/10.7326/m13-2331
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.