Diagnostic Accuracy of Point-of-Care Tests for Detecting Albuminuria: A Systematic Review and Meta-analysis
The DOI matches its Crossref record, with a small difference in title or year; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Background Experts recommend screening for albuminuria in patients at risk for kidney disease. Purpose To systematically review evidence about the diagnostic accuracy of point-of-care (POC) tests for detecting albuminuria in individuals for whom guidelines recommend such detection. Data sources Cochrane Library, EMBASE, Medion database, MEDLINE, and Science Citation Index from 1963 through 5 December 2013; hand searches of other relevant journals; and reference lists. Study selection Cross-sectional studies, published in any language, that compared the accuracy of machine-read POC tests of urinary albumin-creatinine ratio with that of laboratory measurement. Data extraction Two independent reviewers extracted study data and assessed study quality using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool. Data synthesis Sixteen studies (n = 3356 patients) that evaluated semiquantitative or quantitative POC tests and used random urine samples collected in primary or secondary ambulatory care settings met inclusion criteria. Pooling results from a bivariate random-effects model gave sensitivity and specificity estimates of 76% (95% CI, 63% to 86%) and 93% (CI, 84% to 97%), respectively, for the semiquantitative test. Sensitivity and specificity estimates for the quantitative test were 96% (CI, 78% to 99%) and 98% (CI, 93% to 99%), respectively. The negative likelihood ratios for the semiquantitative and quantitative tests were 0.26 (CI, 0.16 to 0.40) and 0.04…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Clinical operators have a lower sensitivity but better specificity than laboratory technologists (500)”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [500]
In the citing paper
“Screening using two tests with either being positive interpreted as a positive (leading to subsequent quantitative testing) increases the sensitivity to 97% but reduces the specificity to 83% (500,501).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [500]
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
(2013) · Kidney International Supplements · doi:10.1038/kisup.2012.73 · Cited by 3,206
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910 · cited 1×
“We explored publication bias by using a regression of the log of the diagnostic odds ratio against the inverse of the square root of the effective sample size, weighted by effective sample size (29).”
MethodFox, C. S., Matsushita, K., Woodward, M., Bilo, H. J., Chalmers, J., Heerspink, H. J. L., Lee, B. J., Perkins, R. M., Rossing, P., Sairenchi, T., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61350-6 · Cited by 1,401
van der Velde, M., the Chronic Kidney Disease Prognosis Consortium, Matsushita, K., Coresh, J., Astor, B. C., Woodward, M., Levey, A. S., de Jong, P. E., & Gansevoort, R. T. (2011) · Kidney International · doi:10.1038/ki.2010.536 · Cited by 1,082
Gansevoort, R. T., Matsushita, K., van der Velde, M., Astor, B. C., Woodward, M., Levey, A. S., de Jong, P. E., & Coresh, J. (2011) · Kidney International · doi:10.1038/ki.2010.531 · Cited by 883
Astor, B. C., the Chronic Kidney Disease Prognosis Consortium, Matsushita, K., Gansevoort, R. T., van der Velde, M., Woodward, M., Levey, A. S., Jong, P. E. D., & Coresh, J. (2011) · Kidney International · doi:10.1038/ki.2010.550 · Cited by 774
Biological Variation: From Principles to Practice
Fraser, C. G. (2001) · Cited by 653
Age and Association of Kidney Measures With Mortality and End-stage Renal Disease
Hallan, S. I., Matsushita, K., Sang, Y., Mahmoodi, B. K., Black, C., Ishani, A., Kleefstra, N., Naimark, D., Roderick, P., Tonelli, M., et al. (2012) · JAMA · doi:10.1001/jama.2012.16817 · Cited by 636
metandi: Meta-analysis of diagnostic accuracy using hierarchical logistic regression
Harbord, R. M., & Whiting, P. (2009) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0900900203 · Cited by 453 · cited 2×
“All statistical analysis was done using the metandi and midas commands in Stata, version 12 (StataCorp, College Station, Texas) (27, 28).”
MethodMahmoodi, B. K., Matsushita, K., Woodward, M., Blankestijn, P. J., Cirillo, M., Ohkubo, T., Rossing, P., Sarnak, M. J., Stengel, B., Yamagishi, K., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61272-0 · Cited by 452
Microalbuminuria: An Early Marker of Renal Involvement in Diabetes
Mogensen, C. E., Chachati, A., Christensen, C. K., Close, C. F., Deckert, T., Hommel, E., Kastrup, J., Lefebvre, P., Mathiesen, E. R., Feldt-Rasmussen, B., et al. (1985) · Uremia Investigation · doi:10.3109/08860228509088195 · Cited by 428
Current issues in measurement and reporting of urinary albumin excretion
Miller, W. G., Bruns, D. E., Hortin, G. L., Sandberg, S., Aakre, K. M., McQueen, M. J., Itoh, Y., Lieske, J. C., Seccombe, D. W., Jones, G., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106567 · Cited by 381
Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests
Bossuyt, P. M., Reitsma, J. B., Linnet, K., & Moons, K. G. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.182576 · Cited by 330
Assessment of the accuracy of diagnostic tests: the cross-sectional study
Knottnerus, J. A., & Muris, J. W. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00206-3 · Cited by 312
AN IMMUNOASSAY METHOD FOR URINARY ALBUMIN AT LOW CONCENTRATIONS
Keen, H., & Chlouverakis, C. (1963) · The Lancet · doi:10.1016/s0140-6736(63)90620-2 · Cited by 253
Lamb, E. J., Levey, A. S., & Stevens, P. E. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.184259 · Cited by 169
Self-citationQuantifying the Accuracy of a Diagnostic Test or Marker
Linnet, K., Bossuyt, P. M. M., Moons, K. G. M., & Reitsma, J. B. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.182543 · Cited by 167
Quantifying the Added Value of a Diagnostic Test or Marker
Moons, K. G. M., de Groot, J. A. H., Linnet, K., Reitsma, J. B., & Bossuyt, P. M. M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.182550 · Cited by 152
Urinary protein and albumin excretion corrected by creatinine and specific gravity
Newman, D. J., Pugia, M. J., Lott, J. A., Wallace, J. F., & Hiar, A. M. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(00)00181-9 · Cited by 145
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.163634 · Cited by 144
Original Paper: A likelihood ratio approach to meta-analysis of diagnostic studies
Stengel, D., Bauwens, K., Sehouli, J., Ekkernkamp, A., & Porzsolt, F. (2003) · Journal of Medical Screening · doi:10.1258/096914103321610806 · Cited by 118
Bachmann, L. M., Nilsson, G., Bruns, D. E., McQueen, M. J., Lieske, J. C., Zakowski, J. J., & Miller, W. G. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2013.210302 · Cited by 68
Urinary proteases degrade albumin: implications for measurement of albuminuria in stored samples
Kania, K., Byrnes, E., Beilby, J. P., Webb, S. A. R., & Strong, K. (2010) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009247 · Cited by 67
Systematic Reviews of Studies Quantifying the Accuracy of Diagnostic Tests and Markers
Reitsma, J. B., Moons, K. G., Bossuyt, P. M., & Linnet, K. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.182568 · Cited by 62
PoCT Trial Management Group, Laurence, C. O., Moss, J. R., Briggs, N. E., & Beilby, J. J. (2010) · BMC Health Services Research · doi:10.1186/1472-6963-10-165 · Cited by 57
Parsons, M., Dj, N., Pugia, M. J., Newall, R. G., & Cp, P. (1999) · PubMed · Cited by 55
Self-citationGraziani, M. S., Gambaro, G., Mantovani, L., Sorio, A., Yabarek, T., Abaterusso, C., Lupo, A., & Rizzotti, P. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn639 · Cited by 54
McTaggart, M. P., Price, C. P., Pinnock, R. G., Stevens, P. E., Newall, R. G., & Lamb, E. J. (2012) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2012.05.009 · Cited by 53
Self-citationGuy, M., Newall, R. G., Borzomato, J., Kalra, P. A., & Price, C. P. (2008) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.09.006 · Cited by 47
Self-citationA reference system for urinary albumin: current status
Lieske, J. C., Bondar, O., Miller, W. G., Bachmann, L. M., Narva, A. S., Itoh, Y., Zegers, I., Schimmel, H., Phinney, K., & Bunk, D. M. (2013) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm-2012-0768 · Cited by 47
Validation of a Point-of-Care Assay for the Urinary Albumin:Creatinine Ratio
Parsons, M. P., Newman, D. J., Newall, R. G., & Price, C. P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.414 · Cited by 45
Self-citationUchida, Y., Kurano, Y., & Ito, S. (1998) · Journal of Clinical Laboratory Analysis · doi:10.1002/(sici)1098-2825(1998)12:5<289::aid-jcla7>3.0.co;2-1 · Cited by 43
Howey, J. E. A., Browning, M. C. K., & Fraser, C. G. (1989) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(89)80112-x · Cited by 36 · cited 1×
“Urinary albumin concentration has high intraindividual biological variation, and an analytic goal of a coefficient of variation of 18% has been proposed in the case of a spot urinary albumin test (56).”
BackgroundThe clinical application of a urine albumin:creatinine ratio point-of-care device
Croal, B. L., Mutch, W. J., Clark, B. M., Dickie, A., Church, J., Noble, D., & Ross, I. S. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00450-8 · Cited by 35
Shephard, M., & Gill, J. (2005) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563053857806 · Cited by 30
Poulsen, P. L., & Mogensen, C. E. (1998) · Diabetes Care · doi:10.2337/diacare.21.1.97 · Cited by 28
Point-of-Care Testing Quality: Some Positives but Also Some Negatives
Kazmierczak, S. C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.171538 · Cited by 28
Floch, J. P. L., Marre, M., Rodier, M., & Passa, P. (2001) · PubMed · Cited by 27
Pugia, M. J., Lott, J. A., Luke, K. E., Shihabi, Z. K., Wians, F. H., & Phillips, L. S. (1998) · Journal of Clinical Laboratory Analysis · Cited by 25
Poulsen, P. L., Hansen, B., Amby, T., Terkelsen, T., & Mogensen, C. E. (1992) · PubMed · Cited by 17
Kouri, T., Nokelainen, P., Pelkonen, V., Kosaka, H., & Saeger, B. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510802322419 · Cited by 14
Comparison of methods for urinary albumin determination in patients with type 1 diabetes
Khawali, C., Andriolo, A., & Ferreira, S. R. G. (2002) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2002000300008 · Cited by 14
Screening for microalbuminuria in patients with type 2 diabetes is incomplete in general practice.
Knudsen, S. T., Mosbech, T. H., Hansen, B., Kønig, E., Johnsen, P. C., & Kamper, A. (2012) · PubMed · Cited by 13
Evaluation of point-of-care tests for detecting microalbuminuria in diabetic patients
Lloyd, M., Kuyl, J. M., & van Jaarsveld, H. (2011) · South African Family Practice · doi:10.1080/20786204.2011.10874100 · Cited by 12
Is the Bayer DCA 2000 Acceptable as a Screening Instrument for the Early Detection of Renal Disease?
Shephard, M. D. S., Barratt, L. J., & Simpson-Lyttle, W. (1999) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329903600315 · Cited by 12
Davidson, E. M., & Croal, B. L. (2003) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200306000-00003 · Cited by 10
Pickersgill, A. J., McInnes, E. A., & Wiener, K. (2001) · Diabetic Medicine · doi:10.1046/j.0742-3071.2001.00590.x · Cited by 8
Statistical Methods for Test and Biomarker Evaluation Studies: A Clinical Chemistry Series
Boyd, J. C., Rifai, N., & Annesley, T. M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.192252 · Cited by 5
Research works printed but not linked: 5
- Knudsen ST, 2012, Dan Med J, 59, A4502
- Le Floch JP, 2001, Diabetes Metab, 27, 36
- Parsons M, 1999, Clin Nephrol, 51, 220
- 10.1002/(SICI)1098-2825(1998)12:5<280::AID-JCLA5>3.0.CO;2-A · doi:10.1002/(sici)1098-2825(1998)12:5<280::aid-jcla5>3.0.co;2-a
- Poulsen PL, 1992, Diabete Metab, 18, 395
Cited by
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Self-citationWebster, A. C., Nagler, E. V., Morton, R. L., & Masson, P. (2017) · The Lancet · doi:10.1016/s0140-6736(16)32064-5 · Cited by 3,842
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Metadata
- Authors
- McTaggart, M. P., Newall, R. G., Hirst, J. A., Bankhead, C. R., Lamb, E. J., Roberts, N. W., & Price, C. P.
- Affiliations
- East Kent Hospitals University NHS Foundation Trust (GB)
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2014-04-15
- Volume
- 160
- Issue
- 8
- Pages
- 550-557
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2016924560
- Semantic Scholar
- ec5af8a2770f8e7ade8c1406879482d328b1b53b
- Cited by
- 39
- References
- 52
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 7 · 2023: 4 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 3 · 2015: 2
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
- Keywords
- albuminuria, point-of-care testing, urinary albumin-creatinine ratio, diagnostic accuracy, sensitivity and specificity, kidney disease screening, chronic kidney disease, negative likelihood ratio, outpatient care
- MeSH terms
- Albuminuria, Humans, Quality Assurance, Health Care, Sensitivity and Specificity, Likelihood Functions, Point-of-Care Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.