Quantitative Assessment of Macular Edema With Optical Coherence Tomography
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate optical coherence tomography, a new technique for high-resolution cross-sectional imaging of the retina, for quantitative assessment of retinal thickness in patients with macular edema. DESIGN: Survey examination with optical coherence tomography of patients with macular edema. SETTING: Referral eye center. PATIENTS: Forty-nine patients with the clinical diagnosis of diabetes or diabetic retinopathy and 25 patients with macular edema secondary to retinal vein occlusion, uveitis, epiretinal membrane formation, or cataract extraction. MAIN OUTCOME MEASURES: Correlation of optical coherence tomograms with slit-lamp biomicroscopy, fluorescein angiography, and visual acuity. RESULTS: Optical coherence tomograms of cystoid macular edema closely corresponded to known histopathologic characteristics. Quantitative measurement of retinal thickness is possible because of the well-defined boundaries in optical reflectivity at the inner and outer margins of the neurosensory retina. Serial optical coherence tomographic examinations allowed tracking of both the longitudinal progression of macular thickening and the resolution of macular edema after laser photocoagulation. In patients with diabetic retinopathy, measurements of central macular thickness with optical coherence tomography correlated with visual acuity, and optical coherence tomography was more sensitive than slit-lamp biomicroscopy to small changes in retinal thickness. CONCLUSIONS: Optical coherence tomography appears useful for objectively monitoring retinal thickness with high resolution in patients with macular edema. It may eventually prove to be a sensitive diagnostic test for the early detection of macular thickening in patients with diabetic retinopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationOptical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Self-citationImaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Self-citationMicrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
Izatt, J. A. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090240090031 · Cited by 927
In vivo retinal imaging by optical coherence tomography
Swanson, E. A., Izatt, J. A., Lin, C. P., Fujimoto, J. G., Schuman, J. S., Hee, M. R., Huang, D., & Puliafito, C. A. (1993) · Optics Letters · doi:10.1364/ol.18.001864 · Cited by 918
Self-citationSchuman, J. S. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100050054031 · Cited by 879
Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582
Self-citationMicron‐resolution ranging of cornea anterior chamber by optical reflectometry
Huang, D., Wang, J., Lin, C. P., Puliafito, C. A., & Fujimoto, J. G. (1991) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900110506 · Cited by 153
Cited by
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Topography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
Self-citationTheory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
(2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.06.052 · Cited by 614
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Paunescu, L. A., Schuman, J. S., Price, L. L., Stark, P. C., Beaton, S., Ishikawa, H., Wollstein, G., & Fujimoto, J. G. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0514 · Cited by 536
Intravitreal triamcinolone for uveitic cystoid macular edema: an optical coherence tomography study
Antcliff, R. J., Spalton, D. J., Stanford, M. R., Graham, E. M., ffytche, T. J., & Marshall, J. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00658-8 · Cited by 487
The Development, Commercialization, and Impact of Optical Coherence Tomography
Fujimoto, J., & Swanson, E. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19963 · Cited by 472
Wolf-Schnurrbusch, U. E. K., Ceklic, L., Brinkmann, C. K., Iliev, M. E., Frey, M., Rothenbuehler, S. P., Enzmann, V., & Wolf, S. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2970 · Cited by 424
Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography
Chan, A. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.2.193 · Cited by 424
Optical Coherence Tomography of Age-related Macular Degeneration and Choroidal Neovascularization
Hee, M. R., Baumal, C. R., Puliafito, C. A., Duker, J. S., Reichel, E., Wilkins, J. R., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30512-5 · Cited by 416
Self-citationCampochiaro, P. A., Brown, D. M., Pearson, A., Ciulla, T., Boyer, D., Holz, F. G., Tolentino, M., Gupta, A., Duarte, L., Madreperla, S., et al. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.12.028 · Cited by 405
Iseri, P. K., Altinaş, Ö., Tokay, T., & Yüksel, N. (2006) · Journal of Neuro-Ophthalmology · doi:10.1097/01.wno.0000204645.56873.26 · Cited by 400
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Characterization of Epiretinal Membranes Using Optical Coherence Tomography
Wilkins, J. R., Puliafito, C. A., Hee, M. R., Duker, J. S., Reichel, E., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30377-1 · Cited by 390
Self-citationMorphological and functional retinal impairment in Alzheimer's disease patients
Parisi, V., Restuccia, R., Fattapposta, F., Mina, C., Bucci, M. G., & Pierelli, F. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00620-4 · Cited by 344
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
The Pathogenesis of Edema in Diabetic Maculopathy
Antcliff, R. J., & Marshall, J. (1999) · Seminars in Ophthalmology · doi:10.3109/08820539909069541 · Cited by 342
Srinivasan, V. J., Wojtkowski, M., Witkin, A. J., Duker, J. S., Ko, T. H., Carvalho, M., Schuman, J. S., Kowalczyk, A., & Fujimoto, J. G. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.046 · Cited by 317
Grover, S., Murthy, R. K., Brar, V. S., & Chalam, K. V. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.03.006 · Cited by 312
Scott, C. J. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.94 · Cited by 307
Optical Coherence Tomographic Patterns of Diabetic Macular Edema
Kim, B. Y., Smith, S. D., & Kaiser, P. K. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.04.023 · Cited by 290
Evaluation of Age-related Macular Degeneration With Optical Coherence Tomography
Keane, P. A., Patel, P. J., Liakopoulos, S., Heussen, F. M., Sadda, S. R., & Tufail, A. (2012) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.01.006 · Cited by 280
Uji, A., Murakami, T., Nishijima, K., Akagi, T., Horii, T., Arakawa, N., Muraoka, Y., Ellabban, A. A., & Yoshimura, N. (2012) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.08.041 · Cited by 273
Kim, S. J., Equi, R., & Bressler, N. M. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.053 · Cited by 268
Reichel, E., Berrocal, A. M., Ip, M., Kroll, A. J., Desai, V., Duker, J. S., & Puliafito, C. A. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90400-1 · Cited by 266
Altintaş, Ö., Işeri, P., Özkan, B., & Çağlar, Y. (2008) · Documenta Ophthalmologica · doi:10.1007/s10633-007-9091-8 · Cited by 240
Diabetic macular edema: Evidence-based management
Stewart, M., Browning, D., & Lee, C. (2018) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1240_18 · Cited by 237
Ko, T. H., Fujimoto, J. G., Schuman, J. S., Paunescu, L. A., Kowalevicz, A. M., Hartl, I., Drexler, W., Wollstein, G., Ishikawa, H., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.027 · Cited by 224
CYSTOID MACULAR DEGENERATION IN CHRONIC CENTRAL SEROUS CHORIORETINOPATHY
IIDA, T., YANNUZZI, L. A., SPAIDE, R. F., BORODOKER, N., CARVALHO, C. A., & NEGRÃO, S. (2003) · RETINA · doi:10.1097/00006982-200302000-00001 · Cited by 215
Optical Coherence Tomography May Be Used to Predict Visual Acuity in Patients with Macular Edema
Pelosini, L., Hull, C. C., Boyce, J. F., McHugh, D., Stanford, M. R., & Marshall, J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4493 · Cited by 208
“In the former location, there is a potential to displace bipolar cells leading to cell loss or compromised function, whilst in the latter, only photoreceptor cells are at risk 8, 9 .”
Colston, B. W., Sathyam, U. S., DaSilva, L. B., Everett, M. J., Stroeve, P., & Otis, L. L. (1998) · Optics Express · doi:10.1364/oe.3.000230 · Cited by 197
Optical Coherence Tomography (OCT): Imaging the Visual Pathway as a Model for Neurodegeneration
Galetta, K. M., Calabresi, P. A., Frohman, E. M., & Balcer, L. J. (2011) · Neurotherapeutics · doi:10.1007/s13311-010-0005-1 · Cited by 185
Review of optical coherence tomography in oncology
Wang, J., Xu, Y., & Boppart, S. A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121711 · Cited by 172
Browning, D. J., Glassman, A. R., Aiello, L. P., Bressler, N. M., Bressler, S. B., Danis, R. P., Davis, M. D., Ferris, F. L., Huang, S. S., Kaiser, P. K., et al. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.12.004 · Cited by 164
Hajali, M., Fishman, G. A., & Anderson, R. J. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.138560 · Cited by 158
DeCroos, F. C., Toth, C. A., Stinnett, S. S., Heydary, C. S., Burns, R., & Jaffe, G. J. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.06.040 · Cited by 67
Metadata
- Authors
- Hee, M. R.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1995-08-01
- Volume
- 113
- Issue
- 8
- Pages
- 1019
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2015659872
- Cited by
- 710
- References
- 8
- FWCI
- 14.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.