The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
The Development, Commercialization, and Impact of Optical Coherence Tomography
Open accessAbstract
This review was written for the special issue of IOVS to describe the history of optical coherence tomography (OCT) and its evolution from a nonscientific, historic perspective. Optical coherence tomography has become a standard of care in ophthalmology, providing real-time information on structure and function - diagnosing disease, evaluating progression, and assessing response to therapy, as well as helping to understand disease pathogenesis and create new therapies. Optical coherence tomography also has applications in multiple clinical specialties, fundamental research, and manufacturing. We review the early history of OCT describing how research and development evolves and the important role of multidisciplinary collaboration and expertise. Optical coherence tomography had its origin in femtosecond optics, but used optical communications technologies and required advanced engineering for early OCT prototypes, clinical feasibility studies, entrepreneurship, and corporate development in order to achieve clinical acceptance and clinical impact. Critical advances were made by early career researchers, clinician scientists, engineering experts, and business leaders, which enabled OCT to have a worldwide impact on health care. We introduce the concept of an "ecosystem" consisting of research, government funding, collaboration and competition, clinical studies, innovation, entrepreneurship and industry, and impact - all of which must work synergistically. The process that we recount is long and challenging, but it is our hope that it might inspire early career professionals in science, engineering, and medicine, and that the clinical and research community will find this review of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationPerformance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Imaging of Macular Diseases with Optical Coherence Tomography
Puliafito, C. A., Hee, M. R., Lin, C. P., Reichel, E., Schuman, J. S., Duker, J. S., Izatt, J. A., Swanson, E. A., & Fujimoto, J. G. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31032-9 · Cited by 1,267
Self-citationde Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Wojtkowski, M., Srinivasan, V. J., Ko, T. H., Fujimoto, J. G., Kowalczyk, A., & Duker, J. S. (2004) · Optics Express · doi:10.1364/opex.12.002404 · Cited by 1,022
Self-citationHuber, R., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
Self-citation
Cited by
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Diabetic retinopathy: Looking forward to 2030
Tan, T.-E., & Wong, T. Y. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.1077669 · Cited by 511
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Insights into Systemic Disease through Retinal Imaging-Based Oculomics
Wagner, S. K., Fu, D. J., Faes, L., Liu, X., Huemer, J., Khalid, H., Ferraz, D., Korot, E., Kelly, C., Balaskas, K., et al. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.6 · Cited by 305
Metadata
- Authors
- Fujimoto, J., & Swanson, E.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2016-07-13
- Volume
- 57
- Issue
- 9
- Pages
- OCT1
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2474279305
- Cited by
- 472
- References
- 38
- FWCI
- 17.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Development, Commercialization, and Impact of Optical Coherence Tomography. https://app.cochat.ai/papers/10.1167/iovs.16-19963
- The paper
- Fujimoto, J., & Swanson, E. (2016). The Development, Commercialization, and Impact of Optical Coherence Tomography. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.16-19963
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.