Effect of Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes Treated With Basal Insulin: A Randomized Clinical Trial
Open accessAbstract
Importance: Continuous glucose monitoring (CGM) has been shown to be beneficial for adults with type 2 diabetes using intensive insulin therapy, but its use in type 2 diabetes treated with basal insulin without prandial insulin has not been well studied. Objective: To determine the effectiveness of CGM in adults with type 2 diabetes treated with basal insulin without prandial insulin in primary care practices. Design, Setting, and Participants: This randomized clinical trial was conducted at 15 centers in the US (enrollment from July 30, 2018, to October 30, 2019; follow-up completed July 7, 2020) and included adults with type 2 diabetes receiving their diabetes care from a primary care clinician and treated with 1 or 2 daily injections of long- or intermediate-acting basal insulin without prandial insulin, with or without noninsulin glucose-lowering medications. Interventions: Random assignment 2:1 to CGM (n = 116) or traditional blood glucose meter (BGM) monitoring (n = 59). Main Outcomes and Measures: The primary outcome was hemoglobin A1c (HbA1c) level at 8 months. Key secondary outcomes were CGM-measured time in target glucose range of 70 to 180 mg/dL, time with glucose level at greater than 250 mg/dL, and mean glucose level at 8 months. Results: Among 175 randomized participants (mean [SD] age, 57 [9] years; 88 women [50%]; 92 racial/ethnic minority individuals [53%]; mean [SD] baseline HbA1c level, 9.1% [0.9%]), 165 (94%) completed the trial. Mean HbA1c level decreased from 9.1% at baseline to 8.0% at 8 months in the CGM group and from 9.0% to 8.4% in the BGM group (adjusted difference, -0.4% [95% CI, -0.8% to -0.1%]; P = .02). In the CGM group, compared with the BGM group, the mean percentage of CGM-measured time in the target glucose range of 70 to 180 mg/dL was 59% vs 43% (adjusted difference, 15% [95% CI, 8% to 23%]; P < .001), the mean percentage of time at greater than 250 mg/dL was 11% vs 27% (adjusted difference, -16% [95% CI, -21% to -11%]; P < .001), and the means of the mean glucose values were 179 mg/dL vs 206 mg/dL (adjusted difference, -26 mg/dL [95% CI, -41 to -12]; P < .001). Severe hypoglycemic events occurred in 1 participant (1%) in the CGM group and in 1 (2%) in the BGM group. Conclusions and Relevance: Among adults with poorly controlled type 2 diabetes treated with basal insulin without prandial insulin, continuous glucose monitoring, as compared with blood glucose meter monitoring, resulted in significantly lower HbA1c levels at 8 months. Trial Registration: ClinicalTrials.gov Identifier: NCT03566693.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Benefits of CGM in this population include reductions in A1C, fewer severe hypoglycemia events in children and adults, increased TIR, as well as significant reductions in hospitalizations for severe hypoglycemia and DKA.156,162–168”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [167]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Continuous glucose monitoring for adults with type 2 diabetes (both those using and not using insulin)24,25 also achieves improved glycated haemoglobin concentrations without impacting the rate of hypoglycaemia.”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [24]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Randomized controlled trials of the use of rt-CGM, compared with standard blood glucose monitoring, in adults with type 2 diabetes have generally shown reductions in HbA 1c with no significant change in time in hypoglycemia (169-172).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [172]
Experimental — accuracy not yet measuredIn the citing paper
“RCT data on rtCGM use in individuals with type 2 diabetes on MDI (59), mixed therapies (10, 60), and basal insulin (61,62) have consistently shown reductions in A1C levels and increases in TIR (70-180 mg/dL [3.9-10 mmol/L]) but not a reduction in rates of hypoglycemia (63).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [61]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Self-citationInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationThe Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Self-citationBolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Self-citationBeck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Self-citationvan Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H. (2016) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30193-0 · Cited by 386
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Self-citation
Cited by
Sorted by citations
Items 201–300 of 542
Cichosz, S. L., Hangaard, S., Kronborg, T., Vestergaard, P., & Jensen, M. H. (2025) · PeerJ · doi:10.7717/peerj.19501 · Cited by 8
The effect of type 2 diabetes genetic predisposition on non-cardiovascular comorbidities
Arruda, A. L., Bocher, O., Taylor, H. J., Cammann, D., Yoshiji, S., Yin, X., Zhao, C. G., Chen, J., Wood, A. C., Ken, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-64927-5 · Cited by 8
Advances and Challenges in Wearable Sensors for Health Monitoring
Brazaca, L. C., Lozano, A. M., Mayol, B., Scheidt, D. T., Fazio, D. D., Kim, E., Maroli, G., Rosati, G., Ates, H. C., Wang, H., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04520 · Cited by 9
Salam, M., Bailey, R. J., Calhoun, P. M., McGill, J. B., Bergenstal, R. M., Price, D. A., & Beck, R. W. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0387 · Cited by 9
Self-citationLipska, K. J., Oladele, C., Zawack, K., Gulanski, B., Mutalik, P., Reaven, P. D., Lynch, J. A., Lee, K. M., Shih, M., Lee, J. S., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0152 · Cited by 8
Expert Roundtable on Continuous Glucose Monitoring
Rosenfeld, C. R., Blevins, T., Aleppo, G., Forlenza, G. P., Isaacs, D. M., Morales, J., Seley, J. J., & Unger, J. R. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.03.015 · Cited by 8
Self-citationEffects of Variability in Glycemic Indices on Longevity in Chinese Centenarians
Ji, S.-H., Dong, C., Chen, R., Shen, C., Xiao, J., Gu, Y., & Gao, J. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.955101 · Cited by 8
Ko, J., Moon, S., Ajjan, R. A., Lee, M. Y., Lee, H., Choi, B., Park, J., Lee, S., Kang, J., & Park, C. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.16304 · Cited by 7
Reddy, S., Wu, C. C., José, A. S., Hsieh, J. L., & Rautela, S. D. (2023) · Clinical Diabetes · doi:10.2337/cd22-0128 · Cited by 8
“Although these types of studies have limitations, their findings are supported by one randomized controlled trial (40) and smaller observational cohort studies (18,19,23,41).”
Ribeiro, S. A. G., Pedrotti, M., Hespanhol, L. C., Balieiro, C. C. A., Paqualotto, E., Silva, R. R. E., Gauza, M. D. M., & de Sá, J. R. (2024) · Metabolism Open · doi:10.1016/j.metop.2024.100285 · Cited by 7
“Nasopharyngitis, a commonly reported adverse event, was also observed in both degludec and glargine-treated patients in previous RCTs [51].”
Sun, Y., Lu, B., Hu, Y.-W., Lv, Y., & Zhong, S. (2024) · International Journal of General Medicine · doi:10.2147/ijgm.s477497 · Cited by 11
Merino-Torres, J. F., Ilham, S., Alshannaq, H. A., Pollock, R. F., Ahmed, W., & Norman, G. J. (2024) · ClinicoEconomics and Outcomes Research · doi:10.2147/ceor.s483459 · Cited by 8
“17 The base case values for parameters representing QoL benefits associated with the rt-CGM intervention (ie, the combined 0.05536 utility value comprising avoidance of fingerstick testing [AFS] and FoH) were also altered.”
BackgroundMethodInfluentialDavidsen, L., Cichosz, S. L., Stæhr, P., Vestergaard, P., Drewes, A. M., Knop, F. K., Jensen, M. H., & Olesen, S. S. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16356 · Cited by 8
Ehrhardt, N. M., Montour, L., Berberian, P., Vasconcelos, A. G., Comstock, B. A., & Wright, L. A.-C. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251331526 · Cited by 7
“32 However, our patient characteristics were different: 50% of the MOBILE’s participants had commercial insurance and only 29% were Latino.”
InfluentialNishimura, R., Okada, Y., Kuroda, A., Suzuki, J., Hirota, Y., Matsuhisa, M., Ishiguro, M., Ohno, T., Suganuma, Y., Tanaka, K., et al. (2025) · Diabetology International · doi:10.1007/s13340-025-00820-2 · Cited by 7
“Furthermore, the MOBILE study reported a TIR of 59% and a TBR of 0.2% following real-time CGM in individuals with type 2 diabetes receiving insulin therapy [36].”
InfluentialHayek, A. A., Klonoff, D. C., Zahrani, W. M. A., Saeed, A. H. A., & Dawish, M. A. A. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112458 · Cited by 8
Martens, T. W., Beck, R. W., Griffen, C., Di, J., Elkind-Hirsch, K. E., Johnson, M. L., Castle, J. R., Beck, S. E., & Bergenstal, R. M. (2025) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2025-005469 · Cited by 8
Self-citationCooper, D. J., Zarabi, S., Farrand, B., Becker, A., & Roslin, M. S. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.1070187 · Cited by 7
Practical Application of Continuous Glucose Monitoring in Clinical Practice: Case Studies
Unger, J., & Franco, D. R. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0080 · Cited by 7
Demidowich, A. P., Stanback, C., & Zilbermint, M. F. (2024) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.15190 · Cited by 9
The Expanding Use of Continuous Glucose Monitoring in Type 2 Diabetes
Dabbagh, Z., McKee, M. D., Pirraglia, P. A., Clements, K. M., Liu, F., Amante, D. J., Shukla, P., & Gerber, B. S. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0536 · Cited by 7
“8,34 In addition, Medicare requirements for CGM approval represent an administrative barrier.”
Elliott, D., Husband, C., Khadem, H., Nemat, H., Cardno, L., Currin, L. G., & Hudson, S. (2025) · Diabetic Medicine · doi:10.1111/dme.15519 · Cited by 6
Hallaj, S., Heinke, A., Kalaw, F. G. P., Gim, N., Blazes, M. S., Owen, J. P., Dysinger, E. J., Benton, E., Cordier, B. A., Evans, N. G., et al. (2025) · EClinicalMedicine · doi:10.1016/j.eclinm.2025.103729 · Cited by 8
“Deiden-tified CGM data from multiple study groups are accessible for secondary use, 56 and are not considered PHI, despite significant cybersecurity implications.”
Grady, M., Cameron, H., & Holt, E. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01415-3 · Cited by 6
Garden, G. L., Shojaee‐Moradie, F., Hutchison, E. J., Frier, B. M., Shaw, K. M., Heller, S. R., Koehler, G., Mader, J. K., Maher, D., Roberts, G. A., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0069 · Cited by 6
Ajjan, R., Seidu, S., & Riveline, J. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01607-5 · Cited by 9
“RCTs and real-life studies in insulin-treated patients with T2D have shown that CGM is beneficial either through reduction of HbA1c and/or by limiting hypoglycemia and this applies to both multiple daily injections of insulin as well as basal insulin therapies [20–23].”
BackgroundConlin, P. R., Burke, B. V., Hobbs, C., Hurren, K. M., Lang, A. E., Morrison, J. W., Spacek, L., Steil, E. N., Watts, S. A., Weinreb, J. E., et al. (2024) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2024.04.014 · Cited by 6
“Glucose targets such as improving the time with glucose levels of 70 to 180 mg/dL [to convert glucose values to mmol/L, multiply by 0.0555] and reducing the time above 250 mg/dL can be achieved with CGM. 46 However, results may differ by the type of CGM device.”
BackgroundInfluentialAmino Acid Nanofibers Improve Glycemia and Confer Cognitive Therapeutic Efficacy to Bound Insulin
Lee, A., Mason, M. L., Lin, T., Kumar, S. B., Kowdley, D., Leung, J. H., Muhanna, D., Sun, Y., Ortega‐Anaya, J., Yu, L., et al. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics14010081 · Cited by 6
“However, clinical outcomes of continuous glucose monitoring in patients with basal insulin treatment has not reduced the rate of hospitalization of patients with diabetes [3].”
BackgroundToward Revision of the ‘Best Practice for Diabetic Patients on Hemodialysis 2012’
Abe, M., Matsuoka, T., Kawamoto, S., Miyasato, K., & Kobayashi, H. H. (2022) · Kidney and Dialysis · doi:10.3390/kidneydial2040045 · Cited by 6
Assessing non‐adjunctive CGM safety at home and in new markets (ANSHIN)
Chao, C., Andrade, S. B., Bergford, S., Calhoun, P. M., Welsh, J. B., Walker, T. C., & ANSHIN Study Group (2023) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.414 · Cited by 5
Self-citationLever, C. S., Williman, J. A., Boucsein, A., Watson, A. S., Sampson, R. S., Sergel‐Stringer, O. T., Keesing, C., Chepulis, L. M., Wheeler, B. J., de Bock, M. I., et al. (2023) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-023-01244-y · Cited by 6
“Previous studies reporting improvements in glycaemic control using CGM have simultaneously observed only modest adjustments to glucose-lowering therapies in both CGM and control groups [25–27 , 42].”
Maiorino, M. I., Buzzetti, R., Irace, C., Laviola, L., Napoli, N., Pitocco, D., Esposito, K., & on behalf of LIVE CGM working group (2023) · Endocrine · doi:10.1007/s12020-023-03473-w · Cited by 7
Overcoming barriers to technology in special groups
Alshatti, A., & Bishop, K. (2023) · Practical Diabetes · doi:10.1002/pdi.2478 · Cited by 6
Ehrhardt, N. M., Cedeno, B., Montour, L., Sinclair, K., Ferguson, G., Berberian, P., Comstock, B. A., & Wright, L. A.-C. (2023) · BMJ Open · doi:10.1136/bmjopen-2023-082005 · Cited by 7
“26 27 A key factor behind these benefits may be behaviour modification associated with RT-CGM, however, studies are lacking.”
BackgroundAcciaroli, G., van der Linden, J., Chao, C., Walker, T. C., & Oliver, N. (2023) · Diabetic Medicine · doi:10.1111/dme.14946 · Cited by 4
Huang, X., Jiang, J., Liu, L., Lin, Y., Zhang, F., Ling, X., Wei, H., Huang, G., Ye, J., Huang, C., et al. (2024) · Journal of Diabetes Investigation · doi:10.1111/jdi.14371 · Cited by 4
“Compared with traditional monitoring using blood glucose meters, CGM provides glucose measurements, low-and high-glucose alerts, and trend information 25 .”
AlSaleh, A. F. F., Ahmed, J., Alsenani, I., Alhousni, W., AalAbdulsalam, R., & Alshammasi, M. T. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14072216 · Cited by 5
“While complex regimens might pose challenges, appropriate pump therapy can improve adherence in some cases [36].”
A low-power approach to optical glucose sensing via polarisation switching
Hassanpour, E., Nasehi, M., Meymandinezhad, A., & Witthauer, L. (2025) · Scientific Reports · doi:10.1038/s41598-025-99367-0 · Cited by 5
Martens, T. W., Johnson, J. L., Katz, M. L., Davidson, M. B., Schneck, K. B., Xue, J., Chang, X., & Dassau, E. (2025) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2025.103266 · Cited by 5
Self-citationWilmot, E., Moore, P., Sathyapalan, T., Choudhary, P., Lim, J. Z. M., Neupane, S., Crabtree, T. S., Iqbal, A., Evans, M., Rayman, G., et al. (2026) · The Lancet Diabetes and Endocrinology · doi:10.1016/s2213-8587(26)00076-8 · Cited by 5
Self-citationAihara, M., Hayashi, T., Koizumi, C., Sakurai, Y., Sawada, M., Kubota, T., Kadowaki, T., Yamauchi, T., & Kubota, N. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01452-y · Cited by 5
Diabetes technology: Continuous glucose monitoring and the role of ambulatory care pharmacists
Patel, R., Schoen, R. R., & Litten, K. P. (2023) · JAPhA Practice Innovations · doi:10.1016/j.japhpi.2023.100005 · Cited by 6
Kim, J. Y., Jin, S.-M., Andrade, S. B., Chen, B., & Kim, J. H. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0513 · Cited by 5
Hall, T. L., Dickinson, L. M., Warman, M. K., Oser, T. K., & Oser, S. M. (2024) · Journal of the American Association of Nurse Practitioners · doi:10.1097/jxx.0000000000001060 · Cited by 7
Grace, T., Edgington, A., Reinhart, L., Burkart, T., Dyer, E., Halsey, J., Baroudi, K., Hicks, C., Layne, J. E., & Walker, T. C. (2024) · Clinical Diabetes · doi:10.2337/cd24-0030 · Cited by 6
Yoo, J. H., Jun, J. E., Kwak, S. H., & Kim, J. H. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241306136 · Cited by 6
Closing in on closed-loop systems for type 2 diabetes
Beck, R. W. (2023) · Nature Medicine · doi:10.1038/s41591-022-02127-0 · Cited by 5
Self-citationSeidu, S. (2024) · Diabetes Therapy · doi:10.1007/s13300-023-01524-z · Cited by 5
Tabák, Á. G., Kempler, P., Guja, C., Eldor, R., Haluzı́k, M., Klupa, T., Παπάνας, Ν., Stoian, A. P., & Mankovsky, B. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01556-z · Cited by 5
Novel Approaches for Early Diagnosis and Prevention of Cardiometabolic Diseases
Agrawal, A., & Rao, G. H. R. (2023) · Journal of Clinical and Preventive Cardiology · doi:10.4103/jcpc.jcpc_12_23 · Cited by 5
Dapagliflozin in heart failure and type 2 diabetes: Efficacy, cardiac and renal effects, safety
Yu, P., You, Y., Li, S., Mu, B.-C., Nan, M.-H., & Pang, M. (2024) · World Journal of Diabetes · doi:10.4239/wjd.v15.i7.1518 · Cited by 6
Immunological Insights Into Nutritional Deficiency Disorders
Azraida, H., Swathi, N. L., & Ali, A. (2024) · Advances in medical diagnosis, treatment, and care (AMDTC) book series · doi:10.4018/979-8-3693-2947-4.ch004 · Cited by 6
Insulin for people with type 2 diabetes mellitus
Vanderpant, N., Ward, E., Farrell, E., & Theodoraki, A. (2024) · BMJ · doi:10.1136/bmj-2023-078015 · Cited by 6
Parsiani, R., Grace, T., Green, C. R., Castle, J. R., & Wilson, L. M. (2025) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_773_24 · Cited by 5
Continuous and Intermittent Glucose Monitoring in 2022
Dovč, K., Bode, B. W., & Battelino, T. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.2502 · Cited by 5
“…of real-time continuous glucose monitoring use on HbA1c (adjusted difference - 0.4% compared to BGM) and time in range (adjusted difference 15% comparedtoBGM)in175individualswith type 2 diabetes treated with basal insulin with or without noninsulin glucose-lowering medication over 8 months (53).”
InfluentialDiabetestechnologie (Update 2023)
Schütz-Fuhrmann, I., Rami-Merhar, B. M., Fröhlich-Reiterer, E. E., Hofer, S. E., Tauschmann, M., Mader, J. K., Resl, M., Kautzky‐Willer, A., Winhofer-Stöckl, Y., Laimer, M., et al. (2023) · Wiener klinische Wochenschrift · doi:10.1007/s00508-023-02165-9 · Cited by 5
“In einer RCT konnte eine signifikante HbA1c-Reduktion bei Menschen mit schlecht kontrolliertem Diabetes mellitus Typ 2 unter Einsatz von rtCGM gezeigt werden [36].”
BackgroundCurrent Obstacles (With Solutions) in Type 2 Diabetes Management, Alongside Future Directions
Belančić, A., Majanović, S. K., & Rahelić, D. (2023) · Diabetology · doi:10.3390/diabetology4030031 · Cited by 5
Abitbol, A., Jain, A., Tsoukas, M. A., Sigalas, J., Galm, B. P., Lee, J., Qureshy, K., Collins, C., & Woo, V. C. (2024) · Diabetes and Vascular Disease Research · doi:10.1177/14791641241253967 · Cited by 5
Tiano, S. M., Moczygemba, L. R., Hinds, A., Jokerst, J. R., Litten, K. P., Roscoe, C. A., & Sharma, R. (2025) · JAPhA Practice Innovations · doi:10.1016/j.japhpi.2025.100045 · Cited by 4
Wiggins, K. T., Hall, T. L., Jortberg, B. T., Dickinson, W. P., Dickinson, L. M., Parascando, J. A., Fernald, D. H., Sobczak, C., Oser, S. M., & Oser, T. K. (2025) · BMC Family Practice · doi:10.1186/s12875-025-02903-0 · Cited by 5
Setford, S. J. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251377026 · Cited by 4
Son, H., Moon, S. J., & Cho, Y. M. (2025) · Diabetes Therapy · doi:10.1007/s13300-025-01830-8 · Cited by 4
“Initially developed and applied in type 1 diabetes mellitus (T1DM) [2–5], CGM has since demonstrated significant value in the care of patients with T2DM as well [6–9].”
InfluentialInequity in Continuous Glucose Monitor (CGM) Prescribing Behaviors in Primary Care
Milosavljevic, J., Schechter, C. B., Fazzari, M. J., Mathias, P., Mathew, J. T., & Agarwal, S. (2026) · Journal of General Internal Medicine · doi:10.1007/s11606-025-09923-7 · Cited by 4
“3,26,27 Partnership with specialty care may lower barriers to CGM use in primary care by bolstering clinicians’ confidence and familiarity with device initiation.”
Clinical Impact of Continuous Glucose Monitoring in Noninsulin Treated Type 2 Diabetes: A Review
Aleppo, G., Carlson, A. L., McGill, J. B., Alshannaq, H. A., Galindo, R. J., Kruger, D. F., Levy, C. J., Matuoka, J. Y., Ilham, S., Umpierrez, G. E., et al. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251414980 · Cited by 5
Self-citationLind, N., Christensen, M. B., Hansen, D. L., Willaing, I., & Nørgaard, K. (2024) · Diabetic Medicine · doi:10.1111/dme.15321 · Cited by 4
Philis‐Tsimikas, A., Fortmann, A. L., Clark, T. L., Bagsic, S. R. S., Farcas, E., Roesch, S. C., SCHULTZ, J. H., Gilmer, T., Godino, J., Savin, K. L., et al. (2024) · Annals of Behavioral Medicine · doi:10.1093/abm/kaae077 · Cited by 5
Self-citationLever, C. S., Williman, J. A., Boucsein, A., Watson, A. S., Sampson, R. S., Sergel‐Stringer, O. T., Keesing, C., Wheeler, B. J., de Bock, M. I., & Paul, R. G. (2025) · Diabetic Medicine · doi:10.1111/dme.70025 · Cited by 4
“…controlled trial data on the benefits of modern real-time continuous glucose monitoring (rtCGM) in individuals with insulin-requiring type 2 diabetes include the inclusion of participants who were only on basal insulin 4 and those whose non-insulin glucose-lowering therapies had not been optimised.”
Enhancing Type 2 Diabetes Care With CGM Integration: Insights From an Italian Expert Group
Irace, C., Avogaro, A., Bertuzzi, F., Buzzetti, R., Candido, R., Prato, S. D., Bartolo, P. D., Fiorina, P., Giorda, C. B., & Giorgino, F. (2025) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.70059 · Cited by 4
“In a randomized clinical trial [51] carried out at 15 U.S. primary care centres 175 patients treated with basal insulin were randomized to CGM versus SMBG (2:1).”
Norton, B. C., Papaefthymiou, A., Telese, A., Simons-Linares, C. R., Vargo, J., Sharma, V. K., & Haidry, R. J. (2025) · Frontline Gastroenterology · doi:10.1136/flgastro-2025-103211 · Cited by 4
“21 32 We know that frequent monitoring with CGM can have a significant impact on diabetic control with a −0.4% difference reported in one RCT. 36 Weight loss may also be a factor across the studies, although we did not formally assess it in our meta-analysis.”
InfluentialNemlekar, P. M., Hannah, K. L., Green, C. R., & Norman, G. J. (2025) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.70089 · Cited by 4
O'Connor, M. J., Ding, X., Hernandez, C., Hubacz, L., Church, R. J., & O'Connor, L. C. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.11.001 · Cited by 4
Low-Carbohydrate and Ketogenic Dietary Patterns for Type 2 Diabetes Management
Oh, R. (2024) · Federal Practitioner · doi:10.12788/fp.0429 · Cited by 5
“38,39 It is currently unknown if CGMs improve long-term glycemic control, but they appear promising for managing and reducing medications for those on an LC diet.”
BackgroundManagement of Outpatients With Diabetes at High Risk of Hypoglycemia
Thomas, C. C., Chopra, K. A., & Davis, A. M. (2024) · JAMA · doi:10.1001/jama.2024.1137 · Cited by 4
Morris-Murray, M., & Frazzitta, M. A. (2024) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2024.30.10-b.s30 · Cited by 5
Continuous Glucose Monitoring Use in Youth with Type 2 Diabetes: A Pilot Randomized Study
Patel, T., Sala, N. G. L., Macheret, N. A., Glaros, S. B., Dixon, S. A., Meyers, A. G., Mackey, E. R., Estrada, E., & Chung, S. T. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0539 · Cited by 4
Strategies to Reduce Iatrogenic Hypoglycemia and Hypotension in Vulnerable Older Adults
Ouslander, J. G., & Wasserman, M. R. (2025) · Journal of the American Geriatrics Society · doi:10.1111/jgs.70038 · Cited by 4
TERKEŞ, N., Bektaş, H., & Aydemir, M. (2025) · Primary care diabetes · doi:10.1016/j.pcd.2025.09.002 · Cited by 7
Abrahami, D., Hernández–Díaz, S., Munshi, M. N., & Patorno, E. (2023) · Journal of General Internal Medicine · doi:10.1007/s11606-023-08193-5 · Cited by 5
Borges, L. P., de Jesus, P. C., de Souza, J. B., Silva, D. M. R. R., Moura, P. H. M., Santos, R. S., Barreto, M. D. S., Guimarães, A. G., Santana, L. A. D. M., Fonseca, D. L. M., et al. (2024) · Life · doi:10.3390/life14030320 · Cited by 4
Cowart, K., & Carris, N. W. (2021) · JAMA · doi:10.1001/jama.2021.13472 · Cited by 4
Zooming In, Then Out: Why We Must Apply Human-Centered Design to Transform Diabetes Technology
Chao, E. C. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231213665 · Cited by 3
Rickards, G. M., Harrod, J. C., Valle, K. L. D., Caballero, A. E., Palermo, N. E., & McDonnell, M. E. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241288917 · Cited by 4
Satisfaction with Continuous Glucose Monitoring in Pregnant Patients with Type 1 and Type 2 Diabetes
Shrestha, K. S., & Battarbee, A. N. (2024) · American Journal of Perinatology · doi:10.1055/a-2442-7090 · Cited by 3
Flint, K. L., Fiore, M., Justice, A., Carney, J., Colling, C., Li, J. H., & Putman, M. S. (2025) · Journal of General Internal Medicine · doi:10.1007/s11606-025-09449-y · Cited by 3
Wilmot, E. G., Ajjan, R., Cheah, Y. S., Choudhary, P., CRANSTON, I. C., Elliott, R. A., Evans, M. L., Iqbal, A., Kamaruddin, S., Barnard-Kelly, K. D., et al. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-090154 · Cited by 3
“20 While this study included approximately 27% of participants treated with basal insulin plus SGLT-2 inhibitors and/or GLP-1 agonists, there have been no RCTs conducted to date that assess the benefit of CGM specifically in this population.”
Behnke, A., Lucas, K. S., Parkin, C. G., Reddy, V., Orlowski, M., & Edwards, A. (2025) · Diabetes Spectrum · doi:10.2337/ds24-0085 · Cited by 3
Self-citationOriot, P., Bui, L., kurz, N. K. D., Gavriliu, M. M., Negrea, M.-C., & Hermans, M. P. (2025) · Acta Clinica Belgica · doi:10.1080/17843286.2025.2528030 · Cited by 3
Lilly, A. N., King, C. A., & Ortiz, J. (2025) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.70090 · Cited by 3
“…have shown benefits of continuous glucose monitors (CGMs) through improvements in DM-related outcomes such as hemoglobin A1c (A1c), time in range (TIR), patient quality of life, satisfaction, work absentee-ism, and decreased time below range (level 1 hypoglycemia) and hospitalization rates [4–18].”
Lazzaroni, E., Cimino, V., Gandolfi, A., Tinari, C., Bucciarelli, L. G., Morpurgo, P. S., Nasr, M. B., Fiorina, R. M., Pastore, I., Baruffaldi, L., et al. (2026) · Journal of the Endocrine Society · doi:10.1210/jendso/bvaf165 · Cited by 3
Sharma, A. K., Lee, A., Mehta, S., Panjwani, Q., & Burugapalli, B. S. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261423934 · Cited by 3
Diabetes technology: an update
Prahalad, P., Zaharieva, D. P., & Maahs, D. M. (2026) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgag164 · Cited by 4
Silva, K., Valero, P., Espinoza, F., Rivas, J. C., Sauceda-Acosta, D., & Sobrevía, L. (2026) · Handbook of experimental pharmacology · doi:10.1007/164_2026_803 · Cited by 3
Xu, H., Li, C., Li, J., Zhang, F., Wang, W., Liang, T., Liu, X., & Fu, C. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.975544 · Cited by 3
“Continuous glucose monitoring (15), monotherapy and good adherence (12), and health education (16) were found to have positive impacts on the achievement of good glycemic control.”
BackgroundLarson, R., Philbrick, A. M., Carlin, C., & Harris, I. M. (2023) · Journal of Pharmacy Technology · doi:10.1177/87551225231194027 · Cited by 3
Optimizing Glucose Sensor Calibration With Lightweight Neural Networks: A Comparative Study
Cenerini, C., Sabatini, A., Vollero, L., & Pau, D. P. (2024) · IEEE Sensors Letters · doi:10.1109/lsens.2024.3436630 · Cited by 4
“1109/LSENS.2024.3436630 this second approach, which is currently used by the majority of diabetic people, are potential inaccuracies, sensor drift over time, and susceptibility to environment influences, and they are still the object of study by research [5].”
BackgroundInfluentialCGM-Based Blood Glucose Prediction Model With LSTM Encoder–Decoder Architecture
Xu, H., Zhang, Y., Liu, S., Ji, Y., Lv, M., & Li, P. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3517554 · Cited by 3
“CGMS uses glucose sensors to continuously monitor glucose concentrations in interstitial fluid, enabling direct feedback on blood glucose levels and continuous, dynamic tracking of blood glucose fluctuations [6].”
Mohan, V., Kalra, S., Augustine, A., & Kober, J. (2025) · Diabetes Therapy · doi:10.1007/s13300-025-01768-x · Cited by 3
“This was especially valuable in cases of inconsistent monitoring, where traditional lab tests were insufficient [30, 31].”
Myśliwiec, M., Czupryniak, L., Gellert, R., Jankowski, P., Mastalerz–Migas, A., Rękas, M., Strojek, K., & Walczak, M. (2025) · Diabetes Therapy · doi:10.1007/s13300-025-01769-w · Cited by 4
Willis, H. J., Gustafson, S. K., Johnson, E. M., JaKa, M. M., & Bergenstal, R. M. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251377799 · Cited by 3
Self-citationExpert Opinion Statement on Continuous Glucose Monitoring in Type 2 Diabetes in the Arab Gulf Region
Alshaikh, A., BAKHSH, A. M. K., Alsagheir, A., El-Laboudi, A. H., Al-Mohanadi, D. H., Alawadi, F., Elbadawi, H., Alzubaidi, L. M. Y., Al‐Sofiani, M. E., Farooqi, M. H., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251393740 · Cited by 4
Metadata
- Authors
- Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., Davis, G., Kruger, D., Bhargava, A., Young, L., McGill, J. B., Aleppo, G., Nguyen, Q. T., Orozco, I., Biggs, W., Lucas, K. J., Polonsky, W. H., Buse, J. B., Price, D., Bergenstal, R. M., MOBILE Study Group, Carlson, A., Chambers, S., Yang, S., Kirkman, M. S., Kass, A., Fraser, R., Cushman, T., Ramos, C., Magar, M., Walker, M., Serafin-Dokhan, S., Salam, M., Hurst, S., Clifton, M. J., Kravarusic, J., Bansal, A., Fulkerson, C., Ang, L., Richardson, C., Mizokami-Stout, K., Reiss, J., Leone, V., Stifel, K., Dailey, G., Change, A., McCallum, J., Garcia, M. I., Davis, D., Lovell, C., Root, C., Toler, F., Wilhelm, L., Eifert, R., Murguia, L., Cota, B., Nguyen, L., Lipski, R., Lawrence, M. K., Fournier, A., Carter, M., Hoover, S., Cohen, N., Mouse, T., Rusnak, J., Campos, T., Njeru, N., Arant, T., Beck, S. E., & Balo, A.
- Affiliations
- Park Nicollet Health Services (US)
- Jaeb Center for Health Research (US)
- University of Southern California (US)
- University of Michigan, Ann Arbor
- Scripps Whittier Diabetes Institute, San Diego, California
- Vanderbilt University Medical Center (US)
- Emory University (US)
- Henry Ford Health (US)
- Iowa Diabetes Research, West Des Moines
- University of North Carolina at Chapel Hill (US)
- Washington University in St. Louis (US)
- Northwestern University (US)
- Las Vegas Endocrinology, Henderson, Nevada
- Carteret General Hospital (US)
- Amarillo Medical Specialists, Amarillo, Texas
- Diabetes & Endocrinology Consultants PC, Morehead City, North Carolina
- Behavioral Diabetes Institute, San Diego, California
- Dexcom (United States) (US)
- HealthPartners (US)
- for the MOBILE Study Group
- Corresponding author
- Beck, Roy W.
- ORCID
- Martens, Thomas
- Beck, Roy W.
- Bailey, Ryan
- Calhoun, Peter
- Peters, Anne L.
- Bao, Shichun
- Umpierrez, Guillermo
- Davis, Georgia
- Kruger, Davida
- Bhargava, Anuj
- Young, Laura
- McGill, Janet B.
- Aleppo, Grazia
- Polonsky, William H.
- Buse, John B.
- Price, David
- Bergenstal, Richard M.
- Carlson, Anders
- Yang, Shoua
- Kirkman, Marian Sue
- Serafin-Dokhan, Sara
- Salam, Maamoun
- Ang, Lynn
- Richardson, Caroline
- Leone, Virginia
- Dailey, George
- Hoover, Stephanie
- Cohen, Nathan
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2021-06-08
- Volume
- 325
- Issue
- 22
- Pages
- 2262
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- PMC
- PMC8173473
- OpenAlex
- W3164064295
- Cited by
- 543
- References
- 23
- Citations by year
- 2026: 116 · 2025: 132 · 2024: 107 · 2023: 98 · 2022: 65 · 2021: 24
- FWCI
- 54.81
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- JAMA (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (UL1TR001422)
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK092926, P30DK020572, P30DK124723, P30DK111022)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- continuous glucose monitoring, type 2 diabetes, basal insulin, glycemic control, HbA1c, blood glucose meters, time in target glucose range, primary care, intensive insulin therapy, glycemic variability, hypoglycemia, hyperglycemia, HbA1c reduction, HbA1c variability
- MeSH terms
- Glycemic Control, Aged, Blood Glucose, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Male, Middle Aged, Time Factors, Confidence Intervals, Treatment Outcome, Patient Satisfaction, Sample Size, Postprandial Period
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review