The DOI matches its Crossref record; 21 of the 23 references it cites were found in a registry or an index.
Effect of Continuous Glucose Monitoring on Glycemic Control in Patients With Type 2 Diabetes Treated With Basal Insulin: A Randomized Clinical Trial
Open accessAbstract
Importance: Continuous glucose monitoring (CGM) has been shown to be beneficial for adults with type 2 diabetes using intensive insulin therapy, but its use in type 2 diabetes treated with basal insulin without prandial insulin has not been well studied. Objective: To determine the effectiveness of CGM in adults with type 2 diabetes treated with basal insulin without prandial insulin in primary care practices. Design, Setting, and Participants: This randomized clinical trial was conducted at 15 centers in the US (enrollment from July 30, 2018, to October 30, 2019; follow-up completed July 7, 2020) and included adults with type 2 diabetes receiving their diabetes care from a primary care clinician and treated with 1 or 2 daily injections of long- or intermediate-acting basal insulin without prandial insulin, with or without noninsulin glucose-lowering medications. Interventions: Random assignment 2:1 to CGM (n = 116) or traditional blood glucose meter (BGM) monitoring (n = 59). Main Outcomes and Measures: The primary outcome was hemoglobin A1c (HbA1c) level at 8 months. Key secondary outcomes were CGM-measured time in target glucose range of 70 to 180 mg/dL, time with glucose level at greater than 250 mg/dL, and mean glucose level at 8 months. Results: Among 175 randomized participants (mean [SD] age, 57 [9] years; 88 women [50%]; 92 racial/ethnic minority individuals [53%]; mean [SD] baseline HbA1c level, 9.1% [0.9%]), 165 (94%) completed the trial. Mean HbA1c level decreased from 9.1% at baseline to 8.0% at 8 months in the CGM group and from 9.0% to 8.4% in the BGM group (adjusted difference, -0.4% [95% CI, -0.8% to -0.1%]; P = .02). In the CGM group, compared with the BGM group, the mean percentage of CGM-measured time in the target glucose range of 70 to 180 mg/dL was 59% vs 43% (adjusted difference, 15% [95% CI, 8% to 23%]; P < .001), the mean percentage of time at greater than 250 mg/dL was 11% vs 27% (adjusted difference, -16% [95% CI, -21% to -11%]; P < .001), and the means of the mean glucose values were 179 mg/dL vs 206 mg/dL (adjusted difference, -26 mg/dL [95% CI, -41 to -12]; P < .001). Severe hypoglycemic events occurred in 1 participant (1%) in the CGM group and in 1 (2%) in the BGM group. Conclusions and Relevance: Among adults with poorly controlled type 2 diabetes treated with basal insulin without prandial insulin, continuous glucose monitoring, as compared with blood glucose meter monitoring, resulted in significantly lower HbA1c levels at 8 months. Trial Registration: ClinicalTrials.gov Identifier: NCT03566693.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Benefits of CGM in this population include reductions in A1C, fewer severe hypoglycemia events in children and adults, increased TIR, as well as significant reductions in hospitalizations for severe hypoglycemia and DKA.156,162–168”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [167]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Continuous glucose monitoring for adults with type 2 diabetes (both those using and not using insulin)24,25 also achieves improved glycated haemoglobin concentrations without impacting the rate of hypoglycaemia.”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [24]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Randomized controlled trials of the use of rt-CGM, compared with standard blood glucose monitoring, in adults with type 2 diabetes have generally shown reductions in HbA 1c with no significant change in time in hypoglycemia (169-172).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [172]
Experimental — accuracy not yet measuredIn the citing paper
“RCT data on rtCGM use in individuals with type 2 diabetes on MDI (59), mixed therapies (10, 60), and basal insulin (61,62) have consistently shown reductions in A1C levels and increases in TIR (70-180 mg/dL [3.9-10 mmol/L]) but not a reduction in rates of hypoglycemia (63).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [61]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Self-citationInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationThe Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Self-citationBolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Self-citationBeck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Self-citationvan Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H. (2016) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30193-0 · Cited by 386
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Self-citation
Cited by
Sorted by citations
Davies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetes Care · doi:10.2337/dci22-0034 · Cited by 2,104
“As with other wearables, for example, those collecting steps walked or monitoring dietary intake, medication dose administered, or sleep quality, use of CGM has also been proposed as a motivational tool for those with type 2 diabetes not on insulin therapy, but the evidence on this is modest (337).”
BackgroundMethodSelf-citationDavies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetologia · doi:10.1007/s00125-022-05787-2 · Cited by 1,048
“0 mmol/l [70–180 mg/dl]), fewer hyperglycaemic and hypoglycaemic episodes and improvements in diabetes distress [336, 337].”
Self-citationContinuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Self-citationBlonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Self-citationPop‐Busui, R., Januzzi, J. L., Bruemmer, D., Butalia, S., Green, J. B., Horton, W. B., Knight, C. M., Levi, M., Rasouli, N., & Richardson, C. R. (2022) · Diabetes Care · doi:10.2337/dci22-0014 · Cited by 442
“T2D (198)—all of whom are at higher risk”
BackgroundSelf-citationSamson, S. L., Vellanki, P., Blonde, L., Christofides, E. A., Galindo, R. J., Hirsch, I. B., Isaacs, S. D., Izuora, K. E., Low Wang, C. C., Twining, C. L., et al. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.02.001 · Cited by 375
Self-citation7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Self-citationSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Self-citation7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Self-citationWearable Devices in Cardiovascular Medicine
Hughes, A. N., Shandhi, M. M. H., Master, H., Dunn, J., & Brittain, E. L. (2023) · Circulation Research · doi:10.1161/circresaha.122.322389 · Cited by 341
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Self-citation9. pharmacologic approaches to glycemic treatment: standards of care in diabetes—2026
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s009 · Cited by 263
Self-citationContinuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
Jancev, M., Vissers, T. A. C. M., Visseren, F. L. J., van Bon, A. C., Serné, E. H., DeVries, J. H., de Valk, H. W., & van Sloten, T. T. (2024) · Diabetologia · doi:10.1007/s00125-024-06107-6 · Cited by 191
Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes
Garg, S. K., Kipnes, M., Castorino, K., Bailey, T. S., Akturk, H. K., Welsh, J. B., Christiansen, M. P., Balo, A. K., Brown, S. A., Reid, J. L., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0011 · Cited by 179
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s007 · Cited by 215
Self-citationHypoglycemia in diabetes: An update on pathophysiology, treatment, and prevention
Nakhleh, A., & Shehadeh, N. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i12.2036 · Cited by 191
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 164
Self-citationGlycaemic management in diabetes: old and new approaches
Ceriello, A., Prattichizzo, F., Phillip, M., Hirsch, I. B., Mathieu, C., & Battelino, T. (2021) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00245-x · Cited by 149
The relationship between intraocular pressure and glaucoma: An evolving concept
Asrani, S., McGlumphy, E. J., Al‐Aswad, L. A., Chaya, C. J., Lin, S. C., Musch, D. C., Pitha, I., Robin, A. L., Wirostko, B. M., & Johnson, T. V. (2024) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2024.101303 · Cited by 150
Aronson, R., Brown, R. E., Chu, L., Bajaj, H. S., Khandwala, H., Abitbol, A., Malakieh, N., & Goldenberg, R. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14949 · Cited by 118
“4% (4 mmol/mol) greater lowering of HbA1c and a 15% greater time in target range (TIR) using rtCGM.(4) However, among individuals using only non-insulin therapies for type 2 diabetes, rtCGM use, in periodic exposures, did not show an improvement in HbA1c versus controls.”
Continuous glucose monitoring for the routine care of type 2 diabetes mellitus
Ajjan, R. A., Battelino, T., Cos, X., Del Prato, S., Philips, J.-C., Meyer, L., Seufert, J., & Seidu, S. (2024) · Nature Reviews Endocrinology · doi:10.1038/s41574-024-00973-1 · Cited by 117
“…RCT, which involved 175 individuals with T2DM on basal insulin, showed that CGM can significantly reduce HbA 1c , time in hyperglycaemia (defined as >250 mg/dl (13.9 mmol/l)) and the rate of hypoglycaemia events over an 8-month period, compared with a control group using SMBG testing alone 58 .”
InfluentialJarvis, P. R. E., Cardin, J. L., Nisevich-Bede, P. M., & McCarter, J. P. (2023) · Metabolism · doi:10.1016/j.metabol.2023.155640 · Cited by 86
Yoo, J. H., & Kim, J. H. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2022.0271 · Cited by 96
Aleppo, G., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · Diabetes Care · doi:10.2337/dc21-1304 · Cited by 82
“Methods for the initial 8-month randomized trial have been reported (6,7).”
BackgroundSelf-citationCommercial and Scientific Solutions for Blood Glucose Monitoring—A Review
Xue, Y., Thalmayer, A. S., Zeising, S., Fischer, G., & Lübke, M. (2022) · Sensors · doi:10.3390/s22020425 · Cited by 90
A Randomized Trial of Automated Insulin Delivery in Type 2 Diabetes.
Kudva, Y. C., Raghinaru, D., Lum, J. W., Graham, T. E., Liljenquist, D., Spanakis, E. K., Pasquel, F. J., Ahmann, A., Ahn, D. T., Aleppo, G., et al. (2025) · New England Journal of Medicine · doi:10.1056/nejmoa2415948 · Cited by 83
Self-citationBao, S., Bailey, R., Calhoun, P., & Beck, R. W. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0494 · Cited by 81
“Details of the protocol and methods have been previously published 7,8 ; relevant aspects of the protocol are summarized hereunder.”
Self-citationMayberry, L. S., Guy, C., Hendrickson, C. D., McCoy, A. B., & Elasy, T. A. (2023) · Journal of General Internal Medicine · doi:10.1007/s11606-023-08222-3 · Cited by 82
Lin, J. B., Narayanan, R., Philippakis, E., Yonekawa, Y., & Apte, R. S. (2024) · Nature Reviews Disease Primers · doi:10.1038/s41572-024-00501-5 · Cited by 75
“In addition, in patients requiring insulin, approaches for continuous glucose monitoring have been shown to improve glycaemic control as evidenced by significantly lower HbA1c levels 125 .”
Uhl, S., Choure, A., Rouse, B., Loblack, A., & Reaven, P. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad652 · Cited by 76
Moon, J. S., Kang, S., Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Seo, J. A., Kim, M. K., et al. (2024) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0249 · Cited by 81
Oser, T. K., Hall, T. L., Dickinson, L. M., Callen, E. F., Carroll, J. K., Nease, D. E., Michaels, L. C., & Oser, S. M. (2022) · The Annals of Family Medicine · doi:10.1370/afm.2876 · Cited by 81
Lind, N., Christensen, M. B., Hansen, D. L., & Nørgaard, K. (2024) · Diabetes Care · doi:10.2337/dc23-2194 · Cited by 73
Carlson, A. L., Daniel, T. D., DeSantis, A., Jabbour, S. A., French, E. K., Kruger, D. F., Miller, E. M., Özer, K., & Elliott, T. (2022) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002590 · Cited by 73
Self-citationReaven, P. D., Newell, M., Rivas, S., Zhou, X., Norman, G. J., & Zhou, J. (2023) · Diabetes Care · doi:10.2337/dc22-2189 · Cited by 73
Moon, S. J., Kim, K., Lee, W. J., Lee, M. Y., Vigersky, R., & Park, C. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14852 · Cited by 69
“The use of RT-CGM in people with T2D has not been as well-documented, and most of those studies reporting its use in that population have included subjects on insulin.(12,13) Some continuous glucose monitoring (CGM) studies conducted in patients with T2D included participants using only OADs, but these studies also in…”
Expanding the Role of Continuous Glucose Monitoring in Modern Diabetes Care Beyond Type 1 Disease
Klupa, T., Czupryniak, L., Dzida, G. J., Fichna, P., Jarosz-Chobot, P. A., Gumprecht, J., Myśliwiec, M., Szadkowska, A., Bomba-Opon, D. A., Czajkowski, K., et al. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01431-3 · Cited by 89
“Use of CGM in people with T2DM on basal-only insulin is associated with improvements in HbA1c while reducing hypoglycemia [19].”
MethodNdumele, C. E., Rodríguez, F., Dixon, D. L., Khan, S. S., Mukherjee, D., Bajaj, M. S., Bangalore, S., Bozkurt, B., Breathett, K. K., Clarke, S. L., et al. (2026) · Circulation · doi:10.1161/cir.0000000000001453 · Cited by 101
Riveline, J.-P., Roussel, R., Vicaut, E., de Pouvourville, G., Detournay, B., Emery, C., Levrat-Guillen, F., & Guerci, B. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0085 · Cited by 64
Health Care Disparities in Use of Continuous Glucose Monitoring
Isaacs, D. M., Bellini, N. J., Biba, U., Cai, A., & Close, K. L. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0268 · Cited by 63
Shaw, J. L. V., Bannuru, R. R., Beach, L. A., ElSayed, N. A., Freckmann, G., Füzéry, A. K., Fung, A. W. S., Gilbert, J. D., Yun, H., Korpi-Steiner, N. L., et al. (2024) · Diabetes Care · doi:10.2337/dci24-0073 · Cited by 66
Self-citationNatale, P., Chen, S., Chow, C. K., Cheung, N. W., Martinez‐Martin, D., Caillaud, C., Scholes‐Robertson, N., Kelly, A., Craig, J. C., Strippoli, G., et al. (2023) · Journal of Diabetes · doi:10.1111/1753-0407.13454 · Cited by 63
The Glucose Management Indicator: Time to Change Course?
Selvin, E. (2024) · Diabetes Care · doi:10.2337/dci23-0086 · Cited by 67
Choe, H. J., Rhee, E.-J., Won, J. C., Park, K. S., Lee, W.-Y., & Cho, Y. M. (2022) · Diabetes Care · doi:10.2337/dc22-0764 · Cited by 59
“basal insulin in patients with T2D (11,12).”
Digital Technology for Diabetes
Hughes, M. S., Addala, A., & Buckingham, B. (2023) · New England Journal of Medicine · doi:10.1056/nejmra2215899 · Cited by 59
Ndumele, C. E., Rodriguez, F., Dixon, D. L., Khan, S. S., Mukherjee, D., Bajaj, M., Bangalore, S., Bozkurt, B., Breathett, K., Clarke, S. L., et al. (2026) · JACC · doi:10.1016/j.jacc.2026.03.056 · Cited by 90
Galindo, R. J., Ali, M. K., Funni, S. A., Dodge, A. B., Kurani, S. S., Shah, N. D., Umpierrez, G. E., & McCoy, R. G. (2022) · Diabetes Care · doi:10.2337/dc21-1579 · Cited by 53
Self-citationContinuous Glucose Monitoring Use in Older Adults for Optimal Diabetes Management
Munshi, M. N. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0111 · Cited by 59
“In a subanalysis of the randomized MOBILE study, 28 Bao et al. evaluated the effectiveness and safety in 42 T2D adults, age ‡ 65 years (range 56–79 years), treated with basal insulin.”
Chun, K., Oh, J., Lee, C. J., Park, J. J., Lee, S. E., Kim, M., Cho, H., Choi, J., Lee, H., Hwang, K., et al. (2022) · Cardiovascular Diabetology · doi:10.1186/s12933-022-01720-4 · Cited by 50
Chen, E., Prakash, S., Reddi, V. J., Kim, D. A., & Rajpurkar, P. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01115-0 · Cited by 51
How Continuous Glucose Monitoring Can Motivate Self-management: Can Motivation Follow Behaviour?
Vallis, M., Ryan, H., Berard, L., Cosson, E., Kristensen, F. B., Levrat‐Guillen, F., Naïditch, N., RABASA-LHORET, R. P. R., & Polonsky, W. H. (2023) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2023.04.001 · Cited by 48
Self-citationThe History, Evolution and Future of Continuous Glucose Monitoring (CGM)
Bender, C., Vestergaard, P., & Cichosz, S. L. (2025) · Diabetology · doi:10.3390/diabetology6030017 · Cited by 43
Aggarwal, A., Pathak, S., & Goyal, R. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109825 · Cited by 48
Crawford, A. L., & Laiteerapong, N. (2024) · Annals of Internal Medicine · doi:10.7326/aitc202406180 · Cited by 50
Kong, A. P. S., Lim, S. K., Yoo, S.-H., Ji, L., Chen, L., Bao, Y., Yeoh, E. C. K., Chan, S.-P., Wang, C., Mohan, V., et al. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110718 · Cited by 49
Self-citationOser, T. K., Litchman, M. L., Allen, N. A., Kwan, B. M., Fisher, L., Jortberg, B. T., Polonsky, W. H., & Oser, S. M. (2021) · Current Diabetes Reports · doi:10.1007/s11892-021-01408-1 · Cited by 45
Self-citationComprehensive Telehealth Model to Support Diabetes Self-Management
Aleppo, G., Gal, R. L., Raghinaru, D., Kruger, D., Beck, R. W., Bergenstal, R. M., Cushman, T., Hood, K. K., Johnson, M. L., McArthur, T., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.36876 · Cited by 42
“The median (IQR) number of additional follow-up contacts per participant was 8 (6-10).”
BackgroundSelf-citationComparisons of Fifth-, Sixth-, and Seventh-Generation Continuous Glucose Monitoring Systems
Welsh, J. B., Psavko, S., Zhang, X., Gao, P., & Balo, A. K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221099879 · Cited by 43
Self-citationEmerging Diabetes Technologies: Continuous Glucose Monitors/Artificial Pancreases
ALMURASHI, A. M., Rodriguez, E., & Garg, S. K. (2023) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00348-3 · Cited by 55
Clark, T. L., Polonsky, W. H., & Soriano, E. C. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0612 · Cited by 41
Self-citationIdentifying the deficiencies of currently available CGM to improve uptake and benefit
Barnard‐Kelly, K. D., Martínez‐Brocca, M. A., Glatzer, T., & Oliver, N. (2024) · Diabetic Medicine · doi:10.1111/dme.15338 · Cited by 37
Reddy, M., & Oliver, N. S. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15504 · Cited by 42
Isitt, J. J., Roze, S., Sharland, H., Cogswell, G., Alshannaq, H. A., Norman, G. J., & Lynch, P. M. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01324-x · Cited by 40
Kim, J. Y., Jin, S.-M., Sim, K. H., Kim, B.-Y., Cho, J. H., Moon, J. S., Lim, S., Kang, E. S., Park, C.-Y., Kim, S. G., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06152-1 · Cited by 36
Zhang, Z., Wang, Y., Lu, J., & Zhou, J. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16033 · Cited by 37
“6 As CGM has gained progressively wider clinical application, new metrics derived from this technology have emerged, including time in range (TIR 3.9 – 10.0 13 Hence, TIR has been consistently recommended by international consensus statements and guidelines as a valid measure of glycemic control.”
InfluentialLu, J., Ying, Z., Wang, P., Fu, M., Han, C., & Zhang, M. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15328 · Cited by 39
Czupryniak, L., Dzida, G. J., Fichna, P., Jarosz-Chobot, P. A., Gumprecht, J., Klupa, T., Myśliwiec, M., Szadkowska, A., Bomba-Opon, D. A., Czajkowski, K., et al. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01229-9 · Cited by 35
“Importantly, the use of CGM systems is proven to reduce HbA1c in people with type 1 diabetes or type 2 diabetes [3] on intensive insulin therapy, but they are equally effective for people with type 2 diabetes on basal insulin therapy only [4, 5] or those on non-insulin therapy [4].”
BackgroundKong, S.-Y., & Cho, M.-K. (2024) · Healthcare · doi:10.3390/healthcare12050571 · Cited by 36
Zelada, H., Perez‐Guzman, M. C., Cherñavvsky, D. R., & Galindo, R. J. (2023) · Endocrine Connections · doi:10.1530/ec-23-0180 · Cited by 34
“Interestingly, there is also evidence of its benefits in reducing HbA1C in people with T2D on long-acting basal insulin (23).”
BackgroundNathanson, D., Eeg‐Olofsson, K., Spelman, T. D., Bülow, E., Kyhlstedt, M., Levrat‐Guillen, F., & Bolinder, J. (2024) · Diabetologia · doi:10.1007/s00125-024-06289-z · Cited by 34
Aleppo, G., Hirsch, I. B., Parkin, C. G., McGill, J., Galindo, R., Kruger, D. F., Levy, C. J., Forlenza, G. P., Umpierrez, G. E., Grunberger, G., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0268 · Cited by 34
Self-citationJohnston, A. R., Poll, J. B., Hays, E., & Jones, C. W. (2022) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2022.100068 · Cited by 33
Continuous Glucose Monitoring to Optimize Management of Diabetes in Patients with Advanced CKD
Galindo, R. J., de Boer, I. H., Neumiller, J. J., & Tuttle, K. R. (2022) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04510422 · Cited by 35
Prasad‐Reddy, L., Godina, A., Chetty, A. K., Close Concerns, S. F., & Isaacs, D. (2022) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2022.18.2.116 · Cited by 36
Accuracy of continuous glucose monitoring in the hospital setting: an observational study
O’Connor, M. Y., Flint, K. L., Sabean, A., Ashley, A. L., Zheng, H., Yan, J., Steiner, B. A., Anandakugan, N., CALVERLEY, M. M., Bartholomew, R. A., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06250-0 · Cited by 35
“In the outpatient setting, continuous glucose monitoring (CGM) has been shown to improve glycaemic control in people with diabetes [10–13], and has been approved by regulatory agencies for use in determination of appropriate insulin dosing without the need for fingerstick glucose confirmation.”
Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes
Narasaki, Y., Kalantar‐Zadeh, K., Daza, A. C., You, A. S., Novoa, A., Peralta, R. A., Siu, M. K. M., Nguyen, D. V., & Rhee, C. M. (2024) · Diabetes Care · doi:10.2337/dc24-0635 · Cited by 34
Consensus Report on the Use of Continuous Glucose Monitoring in Chronic Kidney Disease and Diabetes
Rhee, C. M., Gianchandani, R. Y., Kerr, D. E., Philis‐Tsimikas, A., Kovesdy, C. P., Stanton, R. C., Drincic, A., Galindo, R. J., Kalantar‐Zadeh, K., Neumiller, J. J., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241292041 · Cited by 34
“109,164,165 Motivated by these observations, DTS convened a panel of experts in nephrology and diabetes to review and discuss the current state of evidence, challenges, and future research directions centered on the use of CGM technology in patients with diabetes and CKD. Conclusions were based on…”
Self-citationBattelino, T., Lalic, N. M., Hussain, S., Ceriello, A., Majanović, S. K., Davies, S., Topsever, P., Heverly, J., Ulivi, F., Brady, K., et al. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112111 · Cited by 34
Davis, G. M., Bailey, R. J., Calhoun, P. M., Price, D. A., & Beck, R. W. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0489 · Cited by 33
“9% and mean (–SD) baseline TIR 70–180 mg/dL was 40% – 25%.(21,22) Potential participants were recruited from primary care practices and were not under the care of an endocrinologist to manage their diabetes.”
BackgroundMethodInfluentialSelf-citationNorman, G. J., Paudel, M. L., Parkin, C. G., Bancroft, T., & Lynch, P. M. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0525 · Cited by 32
“…and real-world retrospective and prospective observational studies, use of rtCGM facilitates reductions in glycated hemoglobin (HbA1c), 11–17 increased time in target glucose range 11–17 and reductions in hypoglycemia risk, 18 with corresponding reductions in diabetes-related hospitalizations.”
Blood Glucose Level Time Series Forecasting: Nested Deep Ensemble Learning Lag Fusion
Khadem, H., Nemat, H., Elliott, D., & Benaissa, M. (2023) · Bioengineering · doi:10.3390/bioengineering10040487 · Cited by 36
“For example, technological breakthroughs, such as continuous glucose monitoring biosensors [17,18] and insulin pumps [19,20], nowadays, serve myriads of type 1 diabetes patients.”
BackgroundAlkabbani, W., CROMER, S. J., Kim, D. H., Paik, J. M., Bykov, K., Munshi, M. N., Wexler, D. J., & Patorno, E. (2025) · Diabetes Care · doi:10.2337/dca25-0006 · Cited by 30
Porter, M., Fonda, S. J., Swigert, T. J., & Ehrhardt, N. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211053886 · Cited by 28
Wearable Microfluidics for Continuous Assay
Lin, P.-H., Nien, H.-H., & Li, B.-R. (2023) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091322-082930 · Cited by 28
Szmuilowicz, E. D., & Aleppo, G. (2022) · Postgraduate Medicine · doi:10.1080/00325481.2022.2110507 · Cited by 27
Diabetes: the role of continuous glucose monitoring
Kluemper, J. R., Smith, A. C., & Wobeter, B. R. (2022) · Drugs in Context · doi:10.7573/dic.2021-9-13 · Cited by 30
Shields, S., Thomas, R., Durham, J., Moran, J., Clary, J., & Ciemins, E. L. (2024) · Scientific Reports · doi:10.1038/s41598-024-83548-4 · Cited by 28
Omotosho, I. A., Shamsuddin, N., Huri, H. Z., Chong, W. L., & Rehman, I. U. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26146909 · Cited by 29
“%) in insulin-treated patients, surpassing traditional blood glucose meters (BGM) [39].”
NiNP/Cu-MOF-C/GCE for the the noninvasive detection of glucose in natural saliva samples
Feng, L., Lin, X., Feng, J., Min, X., & Ni, Y. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108657 · Cited by 26
Short-term use of CGM in youth onset type 2 diabetes is associated with behavioral modifications
Manfredo, J., Lin, T., Gupta, R., Abiola, K., West, M., Busin, K., Tracey, J., Brown, E. A., Magge, S. N., & Wolf, R. M. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1182260 · Cited by 25
Estimating Glycemia From HbA1c and CGM: Analysis of Accuracy and Sources of Discrepancy
Tozzo, V., Genco, M. T., Omololu, S. O., Mow, C., Patel, H. R., Patel, C. H., Ho, S. N., Lam, E., Abdulsater, B., Patel, N., et al. (2024) · Diabetes Care · doi:10.2337/dc23-1177 · Cited by 28
Lu, Y., Liu, D., Liang, Z., Liu, R., Chen, P., Liu, Y., Li, J., Feng, Z., Li, L. M., Sheng, B., et al. (2025) · National Science Review · doi:10.1093/nsr/nwaf039 · Cited by 35
“Evidence from clinical research has demonstrated that CGM devices can improve glycemic con-trol for people with T2DM, as well as more-timely treatment intensification, lower risk of diabetes complications and hospital admissions [86 –88 ].”
Wafa, I. A., Pratama, N. R., Sofia, N. F., Anastasia, E. S., Konstantin, T., Wijaya, M. A., Wiyono, M. R., Djuari, L., & Novida, H. (2022) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0125 · Cited by 24
Kalyani, R. R., Allende-Vigo, M. Z., Antinori-Lent, K. J., Close, K. L., Das, S. R., Deroze, P., Edelman, S. V., El Sayed, N. A., Kerr, D., Neumiller, J. J., et al. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad745 · Cited by 25
From reactive to proactive: Continuous protein monitoring for preventive health care
Donnelly, J. M., Neff, R. A., Sedlack, A. J. H., Juska, V. B., Ayala‐Cardona, L. F., Bass, J. T., McNally, E. M., Shah, S. J., Alshurafa, N. I., Kimchi, E. Y., et al. (2025) · Science · doi:10.1126/science.ady6497 · Cited by 26
Glycaemic control in people with diabetes following acute myocardial infarction
Esdaile, H., Hill, N. E., Mayet, J., & Oliver, N. S. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110644 · Cited by 28
Interruption of Continuous Glucose Monitoring: Frequency and Adverse Consequences
Markov, A. M., Krutilova, P., Cedeno, A., McGill, J. B., & McKee, A. M. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231156572 · Cited by 24
Self-citationSamson, S. L., Vellanki, P., Blonde, L., Hirsch, I. B., Hoang, T. D., Isaacs, S. D., Izuora, K. E., Wang, C. C. L., Ooi, C. P., Padilla, B. I., et al. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.01.006 · Cited by 29
Self-citationContinuous Glucose Monitoring in Older Adults: What We Know and What We Have Yet to Learn
Price, C. E., Callahan, K. E., Aloi, J., & Usoh, C. O. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241234651 · Cited by 25
“16 Similar HbA1c lowering was noted in the RCT by Martens et al 17 who evaluated adults with T2DM managed with MDI or noninsulin glycemic medications, noting a reduction by −1.1% in the CGM arm versus −0.6% Hb A1c reduction in the FSBG arm.”
BackgroundInfluential
Metadata
- Authors
- Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., Davis, G., Kruger, D., Bhargava, A., Young, L., McGill, J. B., Aleppo, G., Nguyen, Q. T., Orozco, I., Biggs, W., Lucas, K. J., Polonsky, W. H., Buse, J. B., Price, D., Bergenstal, R. M., MOBILE Study Group, Carlson, A., Chambers, S., Yang, S., Kirkman, M. S., Kass, A., Fraser, R., Cushman, T., Ramos, C., Magar, M., Walker, M., Serafin-Dokhan, S., Salam, M., Hurst, S., Clifton, M. J., Kravarusic, J., Bansal, A., Fulkerson, C., Ang, L., Richardson, C., Mizokami-Stout, K., Reiss, J., Leone, V., Stifel, K., Dailey, G., Change, A., McCallum, J., Garcia, M. I., Davis, D., Lovell, C., Root, C., Toler, F., Wilhelm, L., Eifert, R., Murguia, L., Cota, B., Nguyen, L., Lipski, R., Lawrence, M. K., Fournier, A., Carter, M., Hoover, S., Cohen, N., Mouse, T., Rusnak, J., Campos, T., Njeru, N., Arant, T., Beck, S. E., & Balo, A.
- Affiliations
- Park Nicollet Health Services (US)
- Jaeb Center for Health Research (US)
- University of Southern California (US)
- University of Michigan, Ann Arbor
- Scripps Whittier Diabetes Institute, San Diego, California
- Vanderbilt University Medical Center (US)
- Emory University (US)
- Henry Ford Health (US)
- Iowa Diabetes Research, West Des Moines
- University of North Carolina at Chapel Hill (US)
- Washington University in St. Louis (US)
- Northwestern University (US)
- Las Vegas Endocrinology, Henderson, Nevada
- Carteret General Hospital (US)
- Amarillo Medical Specialists, Amarillo, Texas
- Diabetes & Endocrinology Consultants PC, Morehead City, North Carolina
- Behavioral Diabetes Institute, San Diego, California
- Dexcom (United States) (US)
- HealthPartners (US)
- for the MOBILE Study Group
- Corresponding author
- Beck, Roy W.
- ORCID
- Martens, Thomas
- Beck, Roy W.
- Bailey, Ryan
- Calhoun, Peter
- Peters, Anne L.
- Bao, Shichun
- Umpierrez, Guillermo
- Davis, Georgia
- Kruger, Davida
- Bhargava, Anuj
- Young, Laura
- McGill, Janet B.
- Aleppo, Grazia
- Polonsky, William H.
- Buse, John B.
- Price, David
- Bergenstal, Richard M.
- Carlson, Anders
- Yang, Shoua
- Kirkman, Marian Sue
- Serafin-Dokhan, Sara
- Salam, Maamoun
- Ang, Lynn
- Richardson, Caroline
- Leone, Virginia
- Dailey, George
- Hoover, Stephanie
- Cohen, Nathan
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2021-06-08
- Volume
- 325
- Issue
- 22
- Pages
- 2262
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- PMC
- PMC8173473
- OpenAlex
- W3164064295
- Cited by
- 543
- References
- 23
- Citations by year
- 2026: 116 · 2025: 132 · 2024: 107 · 2023: 98 · 2022: 65 · 2021: 24
- FWCI
- 54.81
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- JAMA (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (UL1TR001422)
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK092926, P30DK020572, P30DK124723, P30DK111022)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- continuous glucose monitoring, type 2 diabetes, basal insulin, glycemic control, HbA1c, blood glucose meters, time in target glucose range, primary care, intensive insulin therapy, glycemic variability, hypoglycemia, hyperglycemia, HbA1c reduction, HbA1c variability
- MeSH terms
- Glycemic Control, Aged, Blood Glucose, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Male, Middle Aged, Time Factors, Confidence Intervals, Treatment Outcome, Patient Satisfaction, Sample Size, Postprandial Period
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review