The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Validation of Clinical Classification Schemes for Predicting Stroke: Results From the National Registry of Atrial Fibrillation
Abstract
CONTEXT: Patients who have atrial fibrillation (AF) have an increased risk of stroke, but their absolute rate of stroke depends on age and comorbid conditions. OBJECTIVE: To assess the predictive value of classification schemes that estimate stroke risk in patients with AF. DESIGN, SETTING, AND PATIENTS: Two existing classification schemes were combined into a new stroke-risk scheme, the CHADS( 2) index, and all 3 classification schemes were validated. The CHADS( 2) was formed by assigning 1 point each for the presence of congestive heart failure, hypertension, age 75 years or older, and diabetes mellitus and by assigning 2 points for history of stroke or transient ischemic attack. Data from peer review organizations representing 7 states were used to assemble a National Registry of AF (NRAF) consisting of 1733 Medicare beneficiaries aged 65 to 95 years who had nonrheumatic AF and were not prescribed warfarin at hospital discharge. MAIN OUTCOME MEASURE: Hospitalization for ischemic stroke, determined by Medicare claims data. RESULTS: During 2121 patient-years of follow-up, 94 patients were readmitted to the hospital for ischemic stroke (stroke rate, 4.4 per 100 patient-years). As indicated by a c statistic greater than 0.5, the 2 existing classification schemes predicted stroke better than chance: c of 0.68 (95% confidence interval [CI], 0.65-0.71) for the scheme developed by the Atrial Fibrillation Investigators (AFI) and c of 0.74 (95% CI, 0.71-0.76) for the Stroke Prevention in Atrial Fibrillation (SPAF) III scheme. However, with a c statistic of 0.82 (95% CI, 0.80-0.84), the CHADS( 2) index was the most accurate predictor of stroke. The stroke rate per 100 patient-years without antithrombotic therapy increased by a factor of 1.5 (95% CI, 1.3-1.7) for each 1-point increase in the CHADS( 2) score: 1.9 (95% CI, 1.2-3.0) for a score of 0; 2.8 (95% CI, 2.0-3.8) for 1; 4.0 (95% CI, 3.1-5.1) for 2; 5.9 (95% CI, 4.6-7.3) for 3; 8.5 (95% CI, 6.3-11.1) for 4; 12.5 (95% CI, 8.2-17.5) for 5; and 18.2 (95% CI, 10.5-27.4) for 6. CONCLUSION: The 2 existing classification schemes and especially a new stroke risk index, CHADS( 2), can quantify risk of stroke for patients who have AF and may aid in selection of antithrombotic therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Simple, clinically applicable stroke risk-stratification schemes in AF patients were developed in the late 1990s in small cohort studies and have later been refined and validated in larger populations.[364][365][366][367][368]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [365]
Citations
Cites
Statistical Methods for Survival Data Analysis.
Lachenbruch, P. A., & Lee, E. T. (1993) · Journal of the American Statistical Association · doi:10.2307/2290742 · Cited by 2,851
Survival analysis using the SAS system : a practical guide
Allison, P. D. (1995) · Medical Entomology and Zoology · Cited by 2,402
EAFT (European Atrial Fibrillation Trial) Study Group (1993) · The Lancet · doi:10.1016/0140-6736(93)92358-z · Cited by 1,877
Antithrombotic Therapy To Prevent Stroke in Patients with Atrial Fibrillation
Hart, R. G., Benavente, O., McBride, R., & Pearce, L. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00003 · Cited by 1,636
Bootstrapping: A Nonparametric Approach to Statistical Inference.
Aa, Mooney, C. Z., & Duval, R. D. (1994) · Journal of the American Statistical Association · doi:10.2307/2290969 · Cited by 1,365
Management of Anticoagulation before and after Elective Surgery
Kearon, C., & Hirsh, J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705223362107 · Cited by 817
Stroke risk profile: adjustment for antihypertensive medication. The Framingham Study.
D’Agostino, R. B., Wolf, P. A., Belanger, A. J., & Kannel, W. B. (1994) · Stroke · doi:10.1161/01.str.25.1.40 · Cited by 714
Statistical Methods for Survival Data Analysis.
Saggu, P. S., & Lee, E. T. (1994) · Journal of the Royal Statistical Society Series D (The Statistician) · doi:10.2307/2348154 · Cited by 627
Factors Associated With Ischemic Stroke During Aspirin Therapy in Atrial Fibrillation
Hart, R. G., Pearce, L. A., McBride, R., Rothbart, R. M., & ASINGER, R. W. (1999) · Stroke · doi:10.1161/01.str.30.6.1223 · Cited by 532
Cited by
Sorted by citations
Items 101–118 of 118
Agnelli, G., & Paciaroni, M. (2014) · Thrombosis and Haemostasis · doi:10.1160/th13-08-0667 · Cited by 52
Reps, J. M., Williams, R. D., You, S. C., Falconer, T., Minty, E., Callahan, A., Ryan, P. B., Park, R. W., Lim, H.-S., & Rijnbeek, P. (2020) · BMC Medical Research Methodology · doi:10.1186/s12874-020-00991-3 · Cited by 40
Scheuermeyer, F. X., Mackay, M., Christenson, J., Grafstein, E., Pourvali, R., Heslop, C., MacPhee, J., Ward, J., Heilbron, B., McGrath, L., et al. (2015) · Academic Emergency Medicine · doi:10.1111/acem.12750 · Cited by 48
Latest hypertension research to inform clinical practice in Asia
Kario, K., Mogi, M., & Hoshide, S. (2022) · Hypertension Research · doi:10.1038/s41440-022-00874-8 · Cited by 32
Clinical significance of atrial fibrillation detected by cardiac implantable electronic devices
DeCicco, A. E., Finkel, J. B., Greenspon, A. J., & Frisch, D. R. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.01.001 · Cited by 38
Grant, A. M., Guthrie, B., & Dreischulte, T. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004153 · Cited by 32
How much atrial fibrillation is too much atrial fibrillation?
Lamas, G. (2012) · New England Journal of Medicine · doi:10.1056/nejme1111948 · Cited by 36
Silent atrial fibrillation: Definition, clarification, and unanswered issues
Kennedy, H. L. (2015) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12307 · Cited by 32
Kosiuk, J., Kornej, J., Bollmann, A., Piorkowski, C., Myrda, K., Arya, A., Sommer, P., Richter, S., Rolf, S., Husser, D., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.039 · Cited by 36
Strawn, J. R., & Levine, A. (2020) · Biomarkers in Neuropsychiatry · doi:10.1016/j.bionps.2020.100024 · Cited by 30
Zubaid, M., Rashed, W. A., Alsheikh-Ali, A. A., Al-Zakwani, I., AlMahmeed, W., Shehab, A., Sulaiman, K., Qudaimi, A. A., Asaad, N., & Amin, H. (2015) · Angiology · doi:10.1177/0003319714536980 · Cited by 29
Lip, G. Y. H., Clementy, N., Pierre, B., Boyer, M., & Fauchier, L. (2015) · Chest · doi:10.1378/chest.14-2096 · Cited by 26
Supersparse Linear Integer Models for Interpretable Classification
Ustun, B., Tracà, S., & Rudin, C. (2013) · arXiv · doi:10.48550/arxiv.1306.6677 · Cited by 26
Bradley, D. J., & Shen, W.-K. (2007) · Clinical Pharmacology & Therapeutics · doi:10.1038/sj.clpt.6100062 · Cited by 20
Tan, Y., Dede, M., Mohanty, V., Dou, J., Hill, H., Bernstam, E., & Chen, K. (2024) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2024.104648 · Cited by 19
Abdulrahman, A., & Richards, D. (2021) · Multimodal Technologies and Interaction · doi:10.3390/mti5090056 · Cited by 11
Zuo, Y., Fan, J., Sarode, R., Zhang, S., Makris, U. E., Karp, D. R., & Shen, Y.-M. (2018) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/1076029618755946 · Cited by 7
Haemers, P., Claus, P., & Willems, R. (2012) · Cardiology Research and Practice · doi:10.1155/2012/658937 · Cited by 7
Metadata
- Authors
- Gage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J.
- Affiliations
- Washington University in St. Louis (US)
- Houston Methodist (US)
- Yale New Haven Hospital (US)
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2001-06-13
- Volume
- 285
- Issue
- 22
- Pages
- 2864
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2062786076
- Cited by
- 4,832
- References
- 32
- Citations by year
- 2026: 40 · 2025: 81 · 2024: 106 · 2023: 108 · 2022: 148 · 2021: 180 · 2020: 196 · 2019: 197 · 2018: 253 · 2017: 266 · 2016: 367 · 2015: 400 · 2014: 427 · 2013: 432 · 2012: 409
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- JAMA (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (500-99-NH01)
- Agency for Healthcare Research and Quality (R01 HS10133)
- U.S. Public Health Service (500-96-P549, 500-99-VT01, 500-99-ME01, 500-96-P612, 500-99-LA02)
- National Cancer Institute (500-99-CA02)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Clinical Neurology › Acute Ischemic Stroke Management
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
- Keywords
- atrial fibrillation, ischemic stroke, stroke risk prediction, Medicare beneficiaries, antithrombotic therapy, warfarin, congestive heart failure, hypertension, diabetes mellitus, transient ischemic attack, model validation
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Female, Humans, Male, Severity of Illness Index, Cohort Studies, Comorbidity, Proportional Hazards Models, Survival Analysis, Risk Assessment, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review