Incidence of Previously Undiagnosed Atrial Fibrillation Using Insertable Cardiac Monitors in a High-Risk Population: The REVEAL AF Study
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Importance: In approximately 20% of atrial fibrillation (AF)-related ischemic strokes, stroke is the first clinical manifestation of AF. Strategies are needed to identify and therapeutically address previously undetected AF. Objective: To quantify the incidence of AF in patients at high risk for but without previously known AF using an insertable cardiac monitor. Design, Setting, and Participants: This prospective, single-arm, multicenter study was conducted from November 2012 to January 2017. Visits took place at 57 centers in the United States and Europe. Patients with a CHADS2 score of 3 or greater (or 2 with at least 1 additional risk factor) were enrolled. Approximately 90% had nonspecific symptoms potentially compatible with AF, such as fatigue, dyspnea, and/or palpitations. Exposures: Patients underwent monitoring with an insertable cardiac monitor for 18 to 30 months. Main Outcomes and Measures: The primary end point was adjudicated AF lasting 6 or more minutes and was assessed at 18 months. Other analyses included detection rates at points from 30 days to 30 months and among CHADS2 score subgroups. Median time from insertion to detection and the percentage of patients subsequently prescribed oral anticoagulation therapy was also determined. Results: A total of 446 patients were enrolled; 233 (52.2%) were male, and the mean (SD) age was 71.5 (9.9) years. A total of 385 patients (86.3%) received an insertable cardiac monitor, met the primary analysis cohort definition, and were observed for a mean (SD) period of 22.5 (7.7) months. The detection rate of AF lasting 6 or more minutes at 18 months was 29.3%. Detection rates at 30 days and 6, 12, 24, and 30 months were 6.2%, 20.4%, 27.1%, 33.6%, and 40.0%, respectively. At 18 months, AF incidence was similar among patients with CHADS2 scores of 2 (24.7%; 95% CI, 17.3-31.4), 3 (32.7%; 95% CI, 23.8-40.7), and 4 or greater (31.7%; 95% CI, 22.0-40.3) (P = .23). Median (interquartile) time from device insertion to first AF episode detection was 123 (41-330) days. Of patients meeting the primary end point, 13 (10.2%) had 1 or more episodes lasting 24 hours or longer, and oral anticoagulation therapy was prescribed for 72 patients (56.3%). Conclusions and Relevance: The incidence of previously undiagnosed AF may be substantial in patients with risk factors for AF and stroke. Atrial fibrillation would have gone undetected in most patients had monitoring been limited to 30 days. Further trials regarding the value of detecting subclinical AF and of prophylactic therapies are warranted. Trial Registration: clinicaltrials.gov Identifier: NCT01727297.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · Europace · doi:10.1093/europace/euw295 · Cited by 6,439
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000366 · Cited by 2,466
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Javaheri, S., Barbe, F., Campos-Rodriguez, F., Dempsey, J. A., Khayat, R., Javaheri, S., Malhotra, A., Martinez-Garcia, M. A., Mehra, R., Pack, A. I., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.069 · Cited by 1,434
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Self-citationGlotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Mass Screening for Untreated Atrial Fibrillation: The STROKESTOP Study
Svennberg, E., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman, V., & Rosenqvist, M. (2015) · Circulation · doi:10.1161/circulationaha.114.014343 · Cited by 605
Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT
Van Gelder, I. C., Healey, J. S., Crijns, H. J. G. M., Wang, J., Hohnloser, S. H., Gold, M. R., Capucci, A., Lau, C.-P., Morillo, C. A., Hobbelt, A. H., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx042 · Cited by 599
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y.-G., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 480
Lowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458
Boriani, G., Glotzer, T. V., Santini, M., West, T. M., De Melis, M., Sepsi, M., Gasparini, M., Lewalter, T., Camm, J. A., & Singer, D. E. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht491 · Cited by 427
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Capucci, A., Santini, M., Padeletti, L., Gulizia, M., Botto, G., Boriani, G., Ricci, R., Favale, S., Zolezzi, F., Di Belardino, N., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 401
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Flaker, G. C., Belew, K., Beckman, K., Vidaillet, H., Kron, J., Safford, R., Mickel, M., & Barrell, P. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.06.032 · Cited by 341
Screening to identify unknown atrial fibrillation: A systematic review
Lowres, N., Neubeck, L., Redfern, J., & Freedman, S. B. (2013) · Thrombosis and Haemostasis · doi:10.1160/th13-02-0165 · Cited by 327
Wachter, R., Gröschel, K., Gelbrich, G., Hamann, G. F., Kermer, P., Liman, J., Seegers, J., Wasser, K., Schulte, A., Jürries, F., et al. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30002-9 · Cited by 282
Self-citationSubclinical Atrial Fibrillation in Older Patients
Healey, J. S., Alings, M., Ha, A., Leong-Sit, P., Birnie, D. H., de Graaf, J. J., Freericks, M., Verma, A., Wang, J., Leong, D., et al. (2017) · Circulation · doi:10.1161/circulationaha.117.028845 · Cited by 249
Self-citationEngdahl, J., Andersson, L., Mirskaya, M., & Rosenqvist, M. (2013) · Circulation · doi:10.1161/circulationaha.112.126656 · Cited by 233
Relationship between atrial tachyarrhythmias and symptoms
Strickberger, S. A., Ip, J., Saksena, S., Curry, K., Bahnson, T. D., & Ziegler, P. D. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2004.10.042 · Cited by 199
Self-citationShanmugam, N., Boerdlein, A., Proff, J., Ong, P., Valencia, O., Maier, S. K. G., Bauer, W. R., Paul, V., & Sack, S. (2012) · Europace · doi:10.1093/europace/eur293 · Cited by 182
Kirchhof, P., Breithardt, G., Aliot, E., Al Khatib, S., Apostolakis, S., Auricchio, A., Bailleul, C., Bax, J., Benninger, G., Blomstrom-Lundqvist, C., et al. (2013) · Europace · doi:10.1093/europace/eut232 · Cited by 141
ORLOV, M. V., GHALI, J. K., ARAGHI‐NIKNAM, M., SHERFESEE, L., SAHR, D., HETTRICK, D. A., & for the Atrial High Rate Trial Investigators (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00682.x · Cited by 119
Self-citationTurakhia, M. P., Ullal, A. J., Hoang, D. D., Than, C. T., Miller, J. D., Friday, K. J., Perez, M. V., Freeman, J. V., Wang, P. J., & Heidenreich, P. A. (2015) · Clinical Cardiology · doi:10.1002/clc.22387 · Cited by 98
Nasir, J. M., Pomeroy, W. C., Marler, A. T., Hann, M. C., Baykaner, T., Jones, R., Stoll, R., Hursey, K., Meadows, A., Walker, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.04.026 · Cited by 98
Mittal, S., Rogers, J., Sarkar, S., Koehler, J., Warman, E. N., Tomson, T. T., & Passman, R. S. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.05.010 · Cited by 93
Witt, C. T., Kronborg, M. B., Nohr, E. A., Mortensen, P. T., Gerdes, C., & Nielsen, J. C. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.07.007 · Cited by 76
Charitos, E. I., Ziegler, P., Stierle, U., Robinson, D., GRAF, B., Sievers, H., & Hanke, T. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12389 · Cited by 51
Self-citationRegistries in Atrial Fibrillation: From Trials to Real-Life Clinical Practice
Mazurek, M., Huisman, M. V., & Lip, G. Y. H. (2016) · The American Journal of Medicine · doi:10.1016/j.amjmed.2016.09.012 · Cited by 47
Garimella, R. S., Chung, E. H., Mounsey, J. P., Schwartz, J., Pursell, I. W., & Gehi, A. K. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.01.012 · Cited by 39
Reiffel, J. A., Verma, A., Halperin, J. L., Gersh, B. J., Tombul, S., Carrithers, J. A., Sherfesee, L., & Kowey, P. R. (2013) · American Heart Journal · doi:10.1016/j.ahj.2013.10.007 · Cited by 36
Self-citationSilent Atrial Fibrillation: A Critical Review.
Barbarossa, A., Guerra, F., & Capucci, A. (2014) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1138 · Cited by 31
Reiffel, J. A. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw014 · Cited by 19
Self-citationConti, S., Reiffel, J. A., Gersh, B. J., Kowey, P. R., Wachter, R., Halperin, J. L., Kaplon, R. E., Pouliot, E., & Verma, A. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1551 · Cited by 11
Self-citation
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Steinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539
Turakhia, M. P., Desai, M., Hedlin, H., Rajmane, A., Talati, N., Ferris, T., Desai, S., Nag, D., Patel, M., Kowey, P., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2018.09.002 · Cited by 474
Self-citationApixaban for Stroke Prevention in Subclinical Atrial Fibrillation
Healey, J. S., Lopes, R. D., Granger, C. B., Alings, M., Rivard, L., McIntyre, W. F., Atar, D., Birnie, D. H., Boriani, G., Camm, A. J., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2310234 · Cited by 451
Metadata
- Authors
- Reiffel, J. A., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Wachter, R., Pouliot, E., Ziegler, P. D., & for the REVEAL AF Investigators
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2017-10-01
- Volume
- 2
- Issue
- 10
- Pages
- 1120
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W2746322177
- Cited by
- 265
- References
- 39
- FWCI
- 20.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.