Importance: Atrial fibrillation (AF) is a major cause of preventable strokes. Screening asymptomatic individuals for AF may increase anticoagulant use for stroke prevention. Objective: To evaluate 2 home-based AF screening interventions. Design, Setting, and Participants: This multicenter randomized clinical trial recruited individuals from primary care practices aged 75 years or older with hypertension and without known AF. From April 5, 2015, to March 26, 2019, 856 participants were enrolled from 48 practices. Interventions: The control group received standard care (routine clinical follow-up plus a pulse check and heart auscultation at baseline and 6 months). The screening group received a 2-week continuous electrocardiographic (cECG) patch monitor to wear at baseline and at 3 months, in addition to standard care. The screening group also received automated home blood pressure (BP) machines with oscillometric AF screening capability to use twice-daily during the cECG monitoring periods. Main Outcomes and Measures: With intention-to-screen analysis, the primary outcome was AF detected by cECG monitoring or clinically within 6 months. Secondary outcomes included anticoagulant use, device adherence, and AF detection by BP monitors. Results: Of the 856 participants, 487 were women (56.9%); mean (SD) age was 80.0 (4.0) years. Median cECG wear time was 27.4 of 28 days (interquartile range [IQR], 18.4-28.0 days). In the primary analysis, AF was detected in 23 of 434 participants (5.3%) in the screening group vs 2 of 422 (0.5%) in the control group (relative risk, 11.2; 95% CI, 2.7-47.1; P = .001; absolute difference, 4.8%; 95% CI, 2.6%-7.0%; P < .001; number needed to screen, 21). Of those with cECG-detected AF, median total time spent in AF was 6.3 hours (IQR, 4.2-14.0 hours; range 1.3 hours-28 days), and median duration of the longest AF episode was 5.7 hours (IQR, 2.9-12.9 hours). Anticoagulation was initiated in 15 of 20 patients (75.0%) with cECG-detected AF. By 6 months, anticoagulant therapy had been prescribed for 18 of 434 participants (4.1%) in the screening group vs 4 of 422 (0.9%) in the control group (relative risk, 4.4; 95% CI, 1.5-12.8; P = .007; absolute difference, 3.2%; 95% CI, 1.1%-5.3%; P = .003). Twice-daily AF screening using the home BP monitor had a sensitivity of 35.0% (95% CI, 15.4%-59.2%), specificity of 81.0% (95% CI, 76.7%-84.8%), positive predictive value of 8.9% (95% CI, 4.9%-15.5%), and negative predictive value of 95.9% (95% CI, 94.5%-97.0%). Adverse skin reactions requiring premature discontinuation of cECG monitoring occurred in 5 of 434 participants (1.2%). Conclusions and Relevance: In this randomized clinical trial, among older community-dwelling individuals with hypertension, AF screening with a wearable cECG monitor was well tolerated, increased AF detection 10-fold, and prompted initiation of anticoagulant therapy in most cases. Compared with continuous ECG, intermittent oscillometric screening with a BP monitor was an inferior strategy for detecting paroxysmal AF. Large trials with hard clinical outcomes are now needed to evaluate the potential benefits and harms of AF screening. Trial Registration: ClinicalTrials.gov Identifier: NCT02392754.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Ruff, C. T., Giugliano, R. P., Braunwald, E., Hoffman, E. B., Deenadayalu, N., Ezekowitz, M. D., Camm, A. J., Weitz, J. I., Lewis, B. S., Parkhomenko, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62343-0 · Cited by 5,051
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917
Krijthe, B. P., Kunst, A., Benjamin, E. J., Lip, G. Y. H., Franco, O. H., Hofman, A., Witteman, J. C. M., Stricker, B. H., & Heeringa, J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht280 · Cited by 1,419
Atrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Self-citationGlotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Sposato, L. A., Cipriano, L. E., Saposnik, G., Vargas, E. R., Riccio, P. M., & Hachinski, V. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)70027-x · Cited by 694
Mass Screening for Untreated Atrial Fibrillation: The STROKESTOP Study
Svennberg, E., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman, V., & Rosenqvist, M. (2015) · Circulation · doi:10.1161/circulationaha.114.014343 · Cited by 605
Cited by
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Martin, S. S., Aday, A. W., Allen, N. B., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Bansal, N., Beaton, A. Z., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001303 · Cited by 1,080
Svendsen, J. H., Diederichsen, S. Z., Højberg, S., Krieger, D. W., Graff, C., Kronborg, C., Olesen, M. S., Nielsen, J. B., Holst, A. G., Brandes, A., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01698-6 · Cited by 550
Lubitz, S. A., Faranesh, A. Z., Selvaggi, C., Atlas, S. J., McManus, D. D., Singer, D. E., Pagoto, S., McConnell, M. V., Pantelopoulos, A., & Foulkes, A. S. (2022) · Circulation · doi:10.1161/circulationaha.122.060291 · Cited by 355
Wearable Devices in Cardiovascular Medicine
Hughes, A., Shandhi, M. M. H., Master, H., Dunn, J., & Brittain, E. (2023) · Circulation Research · doi:10.1161/circresaha.122.322389 · Cited by 291
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Noseworthy, P. A., Attia, Z. I., Behnken, E. M., Giblon, R. E., Bews, K. A., Liu, S., Gosse, T. A., Linn, Z. D., Deng, Y., Yin, J., et al. (2022) · The Lancet · doi:10.1016/s0140-6736(22)01637-3 · Cited by 257
Palaniappan, L. P., Allen, N. B., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Bansal, N., Currie, M. E., Earlie, R. S., et al. (2026) · Circulation · doi:10.1161/cir.0000000000001412 · Cited by 242
Screening for Atrial Fibrillation: US Preventive Services Task Force Recommendation Statement
US Preventive Services Task Force, Davidson, K. W., Barry, M. J., Mangione, C. M., Cabana, M., Caughey, A. B., Davis, E. M., Donahue, K. E., Doubeni, C. A., Epling, J. W., et al. (2022) · JAMA · doi:10.1001/jama.2021.23732 · Cited by 163
Self-citationThe Role of Wearable Devices in Chronic Disease Monitoring and Patient Care: A Comprehensive Review
Jafleh, E. A., Alnaqbi, F. A., Almaeeni, H. A., Faqeeh, S., Alzaabi, M. A., & Al Zaman, K. (2024) · Cureus · doi:10.7759/cureus.68921 · Cited by 125
“Twice-daily AF screening with the home BP monitor during cECG monitoring periods achieved a sensitivity of 35.0%, specificity of 81.0%, PPV of 8.9%, and NPV of 95.9% [21].”
InfluentialEnhanced Detection and Prompt Diagnosis of Atrial Fibrillation Using Apple Watch
van Steijn, N. J., Blommestijn, I. S., Blok, S., Pepplinkhuizen, S., Somsen, G. A., Knops, R. E., Breukel, L., Tijssen, J. G. P., Tulevski, I. I., Croon, P. M., et al. (2026) · JACC · doi:10.1016/j.jacc.2025.11.032 · Cited by 21
Metadata
- Authors
- Gladstone, D. J., Wachter, R., Schmalstieg-Bahr, K., Quinn, F. R., Hummers, E., Ivers, N., Marsden, T., Thornton, A., Djuric, A., Suerbaum, J., von Grünhagen, D., McIntyre, W. F., Benz, A. P., Wong, J. A., Merali, F., Henein, S., Nichol, C., Connolly, S. J., Healey, J. S., & SCREEN-AF Investigators and Coordinators
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2021-05-01
- Volume
- 6
- Issue
- 5
- Pages
- 558
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W3129415548
- Cited by
- 195
- References
- 72
- FWCI
- 21.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.