Screening for Atrial Fibrillation in the Older Population: A Randomized Clinical Trial
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
Importance: Atrial fibrillation (AF) is a major cause of preventable strokes. Screening asymptomatic individuals for AF may increase anticoagulant use for stroke prevention. Objective: To evaluate 2 home-based AF screening interventions. Design, Setting, and Participants: This multicenter randomized clinical trial recruited individuals from primary care practices aged 75 years or older with hypertension and without known AF. From April 5, 2015, to March 26, 2019, 856 participants were enrolled from 48 practices. Interventions: The control group received standard care (routine clinical follow-up plus a pulse check and heart auscultation at baseline and 6 months). The screening group received a 2-week continuous electrocardiographic (cECG) patch monitor to wear at baseline and at 3 months, in addition to standard care. The screening group also received automated home blood pressure (BP) machines with oscillometric AF screening capability to use twice-daily during the cECG monitoring periods. Main Outcomes and Measures: With intention-to-screen analysis, the primary outcome was AF detected by cECG monitoring or clinically within 6 months. Secondary outcomes included anticoagulant use, device adherence, and AF detection by BP monitors. Results: Of the 856 participants, 487 were women (56.9%); mean (SD) age was 80.0 (4.0) years. Median cECG wear time was 27.4 of 28 days (interquartile range [IQR], 18.4-28.0 days). In the primary analysis, AF was detected in 23 of 434 participants (5.3%) in the screening group vs 2 of 422 (0.5%) in the control group (relative risk, 11.2; 95% CI, 2.7-47.1; P = .001; absolute difference, 4.8%; 95% CI, 2.6%-7.0%; P < .001; number needed to screen, 21). Of those with cECG-detected AF, median total time spent in AF was 6.3 hours (IQR, 4.2-14.0 hours; range 1.3 hours-28 days), and median duration of the longest AF episode was 5.7 hours (IQR, 2.9-12.9 hours). Anticoagulation was initiated in 15 of 20 patients (75.0%) with cECG-detected AF. By 6 months, anticoagulant therapy had been prescribed for 18 of 434 participants (4.1%) in the screening group vs 4 of 422 (0.9%) in the control group (relative risk, 4.4; 95% CI, 1.5-12.8; P = .007; absolute difference, 3.2%; 95% CI, 1.1%-5.3%; P = .003). Twice-daily AF screening using the home BP monitor had a sensitivity of 35.0% (95% CI, 15.4%-59.2%), specificity of 81.0% (95% CI, 76.7%-84.8%), positive predictive value of 8.9% (95% CI, 4.9%-15.5%), and negative predictive value of 95.9% (95% CI, 94.5%-97.0%). Adverse skin reactions requiring premature discontinuation of cECG monitoring occurred in 5 of 434 participants (1.2%). Conclusions and Relevance: In this randomized clinical trial, among older community-dwelling individuals with hypertension, AF screening with a wearable cECG monitor was well tolerated, increased AF detection 10-fold, and prompted initiation of anticoagulant therapy in most cases. Compared with continuous ECG, intermittent oscillometric screening with a BP monitor was an inferior strategy for detecting paroxysmal AF. Large trials with hard clinical outcomes are now needed to evaluate the potential benefits and harms of AF screening. Trial Registration: ClinicalTrials.gov Identifier: NCT02392754.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Ruff, C. T., Giugliano, R. P., Braunwald, E., Hoffman, E. B., Deenadayalu, N., Ezekowitz, M. D., Camm, A. J., Weitz, J. I., Lewis, B. S., Parkhomenko, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62343-0 · Cited by 5,051
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917
Krijthe, B. P., Kunst, A., Benjamin, E. J., Lip, G. Y. H., Franco, O. H., Hofman, A., Witteman, J. C. M., Stricker, B. H., & Heeringa, J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht280 · Cited by 1,419
Atrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Self-citationGlotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Sposato, L. A., Cipriano, L. E., Saposnik, G., Vargas, E. R., Riccio, P. M., & Hachinski, V. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)70027-x · Cited by 694
Mass Screening for Untreated Atrial Fibrillation: The STROKESTOP Study
Svennberg, E., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman, V., & Rosenqvist, M. (2015) · Circulation · doi:10.1161/circulationaha.114.014343 · Cited by 605
Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT
Van Gelder, I. C., Healey, J. S., Crijns, H. J. G. M., Wang, J., Hohnloser, S. H., Gold, M. R., Capucci, A., Lau, C.-P., Morillo, C. A., Hobbelt, A. H., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx042 · Cited by 599
Self-citationHalcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Steinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Self-citationBarrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489
Stroke prevention in atrial fibrillation
Freedman, B., Potpara, T. S., & Lip, G. Y. H. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31257-0 · Cited by 463
Chen, L. Y., Chung, M. K., Allen, L. A., Ezekowitz, M., Furie, K. L., McCabe, P., Noseworthy, P. A., Perez, M. V., & Turakhia, M. P. (2018) · Circulation · doi:10.1161/cir.0000000000000568 · Cited by 439
Boriani, G., Glotzer, T. V., Santini, M., West, T. M., De Melis, M., Sepsi, M., Gasparini, M., Lewalter, T., Camm, J. A., & Singer, D. E. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht491 · Cited by 427
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Lopes, R. D., Alings, M., Connolly, S. J., Beresh, H., Granger, C. B., Mazuecos, J. B., Boriani, G., Nielsen, J. C., Conen, D., Hohnloser, S. H., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.04.008 · Cited by 290
Self-citationGo, A. S., Reynolds, K., Yang, J., Gupta, N., Lenane, J., Sung, S. H., Harrison, T. N., Liu, T. I., & Solomon, M. D. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.1176 · Cited by 286
Wachter, R., Gröschel, K., Gelbrich, G., Hamann, G. F., Kermer, P., Liman, J., Seegers, J., Wasser, K., Schulte, A., Jürries, F., et al. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30002-9 · Cited by 282
Self-citationGenetic Predisposition, Clinical Risk Factor Burden, and Lifetime Risk of Atrial Fibrillation
Weng, L.-C., Preis, S. R., Hulme, O. L., Larson, M. G., Choi, S. H., Wang, B., Trinquart, L., McManus, D. D., Staerk, L., Lin, H., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.031431 · Cited by 274
Reiffel, J. A., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Wachter, R., Pouliot, E., Ziegler, P. D., & for the REVEAL AF Investigators (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3180 · Cited by 265
Self-citationDiagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258
Gorenek, B., Bax, J., Boriani, G., Chen, S.-A., Dagres, N., Glotzer, T. V., Healey, J. S., Israel, C. W., Kudaiberdieva, G., Levin, L.-Å., et al. (2017) · EP Europace · doi:10.1093/europace/eux163 · Cited by 247
Self-citationSchnabel, R. B., Haeusler, K. G., Healey, J. S., Freedman, B., Boriani, G., Brachmann, J., Brandes, A., Bustamante, A., Casadei, B., Crijns, H. J. G. M., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.040267 · Cited by 246
Self-citationAndrade, J. G., Verma, A., Mitchell, L. B., Parkash, R., Leblanc, K., Atzema, C., Healey, J. S., Bell, A., Cairns, J., Connolly, S., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.08.026 · Cited by 233
Self-citationKirchhof, P., Blank, B. F., Calvert, M., Camm, A. J., Chlouverakis, G., Diener, H.-C., Goette, A., Huening, A., Lip, G. Y. H., Simantirakis, E., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.04.015 · Cited by 227
Turakhia, M. P., Ziegler, P. D., Schmitt, S. K., Chang, Y., Fan, J., Than, C. T., Keung, E. K., & Singer, D. E. (2015) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.114.003057 · Cited by 197
Estimated prevalence of undiagnosed atrial fibrillation in the United States
Turakhia, M. P., Shafrin, J., Bognar, K., Trocio, J., Abdulsattar, Y., Wiederkehr, D., & Goldman, D. P. (2018) · PLOS ONE · doi:10.1371/journal.pone.0195088 · Cited by 180
ROSENBERG, M. A., SAMUEL, M., THOSANI, A., & ZIMETBAUM, P. J. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12053 · Cited by 179
Screening for atrial fibrillation: a call for evidence
Jones, N. R., Taylor, C. J., Hobbs, F. D. R., Bowman, L., & Casadei, B. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz834 · Cited by 178
Atrial Fibrillation in Ischemic Stroke: Predicting Response to Thrombolysis and Clinical Outcomes
Saposnik, G., Gladstone, D., Raptis, R., Zhou, L., & Hart, R. G. (2013) · Stroke · doi:10.1161/strokeaha.112.676551 · Cited by 174
Self-citationUS Preventive Services Task Force, Curry, S. J., Krist, A. H., Owens, D. K., Barry, M. J., Caughey, A. B., Davidson, K. W., Doubeni, C. A., Epling, J. W., Kemper, A. R., et al. (2018) · JAMA · doi:10.1001/jama.2018.10321 · Cited by 165
Self-citationProgression of Device-Detected Subclinical Atrial Fibrillation and the Risk of Heart Failure
Wong, J. A., Conen, D., Van Gelder, I. C., McIntyre, W. F., Crijns, H. J., Wang, J., Gold, M. R., Hohnloser, S. H., Lau, C. P., Capucci, A., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.519 · Cited by 150
Self-citationNatural History of Subclinical Atrial Fibrillation Detected by Implanted Loop Recorders
Diederichsen, S. Z., Haugan, K., Brandes, A., Lanng, M. B., Graff, C., Krieger, D. W., Kronborg, C., Holst, A. G., Køber, L., Højberg, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.09.050 · Cited by 145
Diederichsen, S. Z., Haugan, K., Kronborg, C., Graff, C., Højberg, S., Køber, L., Krieger, D. W., Holst, A. G., Nielsen, J. B., Brandes, A., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.044407 · Cited by 140
Boriani, G., Glotzer, T. V., Ziegler, P., Melis, M. D., Stefano, L. M. D. S., Sepši, M., Landolina, M., Lunati, M., Lewalter, T., & Camm, A. J. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.11.007 · Cited by 128
Lowres, N., Olivier, J., Chao, T.-F., Chen, S.-A., Chen, Y., Diederichsen, A., Fitzmaurice, D. A., Gomez-Doblas, J. J., Harbison, J., Healey, J. S., et al. (2019) · PLOS Medicine · doi:10.1371/journal.pmed.1002903 · Cited by 124
Self-citationVorhofflimmern besser erkennen, hilft Schlaganfälle zu verhindern
(2017) · Fortschritte der Neurologie · Psychiatrie · doi:10.1055/s-0043-106146 · Cited by 113
Perino, A. C., Fan, J., Askari, M., Heidenreich, P. A., Keung, E., Raitt, M. H., Piccini, J. P., Ziegler, P. D., & Turakhia, M. P. (2019) · Circulation · doi:10.1161/circulationaha.118.038988 · Cited by 103
Population-Based Screening for Atrial Fibrillation
Khurshid, S., Healey, J. S., McIntyre, W. F., & Lubitz, S. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316341 · Cited by 101
Self-citationUittenbogaart, S. B., Gurp, N. V.-V., Lucassen, W. A. M., Winkens, B., Nielen, M. M. J., Erkens, P. M. G., Knottnerus, J. A., van Weert, H. C. P. M., & Stoffers, J. (2020) · BMJ · doi:10.1136/bmj.m3208 · Cited by 99
Turakhia, M. P., Ullal, A. J., Hoang, D. D., Than, C. T., Miller, J. D., Friday, K. J., Perez, M. V., Freeman, J. V., Wang, P. J., & Heidenreich, P. A. (2015) · Clinical Cardiology · doi:10.1002/clc.22387 · Cited by 98
Emerging Technologies for Identifying Atrial Fibrillation
Ding, E., Marcus, G. M., & McManus, D. D. (2020) · Circulation Research · doi:10.1161/circresaha.119.316342 · Cited by 87
Perera, K. S., Vanassche, T., Bosch, J., Swaminathan, B., Mundl, H., Giruparajah, M., Barboza, M. A., O'Donnell, M. J., Schneider, M. G., Hankey, G. J., et al. (2016) · Stroke · doi:10.1161/strokeaha.116.013378 · Cited by 84
Self-citationVerberk, W. J., Omboni, S., Kollias, A., & Stergiou, G. S. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.10.182 · Cited by 84
Witt, C. T., Kronborg, M. B., Nohr, E. A., Mortensen, P. T., Gerdes, C., & Nielsen, J. C. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.07.007 · Cited by 76
Willits, I., Keltie, K., Craig, J., & Sims, A. (2014) · Applied Health Economics and Health Policy · doi:10.1007/s40258-014-0096-7 · Cited by 67
Burden of atrial high-rate episodes and risk of stroke: a systematic review
Uittenbogaart, S. B., Lucassen, W. A. M., van Etten‐Jamaludin, F. S., de Groot, J. R., & van Weert, H. C. P. M. (2017) · EP Europace · doi:10.1093/europace/eux356 · Cited by 63
Kaasenbrood, F., Hollander, M., de Bruijn, S. H., Dolmans, C. P., Tieleman, R. G., Hoes, A. W., & Rutten, F. H. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x708161 · Cited by 62
Potential Cost-Effectiveness of Ambulatory Cardiac Rhythm Monitoring After Cryptogenic Stroke
Yong, J. H. E., Thavorn, K., Hoch, J. S., Mamdani, M., Thorpe, K. E., Dorian, P., Sharma, M., Laupacis, A., & Gladstone, D. J. (2016) · Stroke · doi:10.1161/strokeaha.115.011979 · Cited by 59
Self-citationFirst Diagnosis of Atrial Fibrillation at the Time of Stroke
Borowsky, L. H., Regan, S., Chang, Y., Ayres, A. M., Greenberg, S. M., & Singer, D. E. (2017) · Cerebrovascular Diseases · doi:10.1159/000457809 · Cited by 59
Chan, P.-H., Wong, C.-K., Pun, L., Wong, Y.-F., Wong, M. M.-Y., Chu, D. W.-S., & Siu, C.-W. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-013685 · Cited by 58
Effectiveness of screening for atrial fibrillation and its determinants. A meta-analysis
Petryszyn, P., Niewinski, P., Staniak, A., Piotrowski, P., Well, A., Well, M., Jeskowiak, I., Lip, G., & Ponikowski, P. (2019) · PLOS ONE · doi:10.1371/journal.pone.0213198 · Cited by 57
Boriani, G., Schnabel, R. B., Healey, J. S., Lópes, R. D., Gurp, N. V.-V., Lobban, T., Camm, A. J., & Freedman, B. (2020) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2020.09.005 · Cited by 57
Self-citationA prospective 5-year follow-up after population-based systematic screening for atrial fibrillation
Engdahl, J., Holmén, A., Rosenqvist, M., & Strömberg, U. (2018) · EP Europace · doi:10.1093/europace/euy045 · Cited by 39
Ackermans, P. A. J., Solosko, T. A., Spencer, E. C., Gehman, S. E., Nammi, K., Engel, J., & Russell, J. K. (2012) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2011.10.007 · Cited by 37
ECG-based cardiac screening programs: legal, ethical, and logistical considerations.
Orchard, J. J., Neubeck, L., Orchard, J. W., Puranik, R., Raju, H., Freedman, B., La Gerche, A., & Semsarian, C. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.025 · Cited by 33
Quinn, F. R., Gladstone, D. J., Ivers, N. M., Sandhu, R. K., Dolovich, L. R., Ling, A. L. H., Nakamya, J., Ramasundarahettige, C. F., Frydrych, P. A., Henein, S., et al. (2018) · CMAJ Open · doi:10.9778/cmajo.20180001 · Cited by 29
Self-citationReiffel, J. A., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Elkind, M. S. V., Ziegler, P., Kaplon, R. E., Sherfesee, L., & Wachter, R. (2019) · American Heart Journal · doi:10.1016/j.ahj.2019.07.016 · Cited by 27
Self-citationEARLY: a pilot study on early diagnosis of atrial fibrillation in a primary healthcare centre
Benito, L., Coll‐Vinent, B., Gomez, E., Marti, D., Mitjavila, J., Torres, F., Miró, Ò., Sisó‐Almirall, A., & Mont, L. (2015) · EP Europace · doi:10.1093/europace/euv146 · Cited by 27
Screening for Atrial Fibrillation Comes With Many Snags
Mandrola, J. M., Foy, A., & Naccarelli, G. V. (2018) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.4038 · Cited by 25
Wiesel, J., & Salomone, T. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.07.016 · Cited by 23
To Screen or Not to Screen? Examining the Arguments Against Screening for Atrial Fibrillation
Neubeck, L., Orchard, J. J., Lowres, N., & Freedman, S. B. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.05.118 · Cited by 23
Kollias, A., Destounis, A., Kalogeropoulos, P., Kyriakoulis, K. G., Ntineri, A., & Stergiou, G. S. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10797 · Cited by 21
McIntyre, W. F., Yong, J. H. E., Sandhu, R. K., Gladstone, D. J., Simek, K. D., Liu, Y. Y., Quinn, F. R., Tytus, R. H., Zizzo, D., Henein, S., et al. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.11.040 · Cited by 13
Self-citationPatients’ views about screening for atrial fibrillation (AF): a qualitative study in primary care
Lown, M. T., Wilcox, C. R., Hughes, S. F., Santer, M., Lewith, G. T., Moore, M. V., & Little, P. S. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-033061 · Cited by 11
Burns, R. B., ZIMETBAUM, P. J., Lubitz, S. A., & Smetana, G. W. (2019) · Annals of Internal Medicine · doi:10.7326/m19-1126 · Cited by 3
AMALFI: Active Monitoring for AtriaL Fibrillation
Taylor, K., & Bowman, L. J. (2019) · http://isrctn.com/ · doi:10.1186/isrctn15544176 · Cited by 2
Cited by
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2022 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001052 · Cited by 5,987
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Martin, S. S., Aday, A. W., Allen, N. B., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Bansal, N., Beaton, A. Z., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001303 · Cited by 1,080
Svendsen, J. H., Diederichsen, S. Z., Højberg, S., Krieger, D. W., Graff, C., Kronborg, C., Olesen, M. S., Nielsen, J. B., Holst, A. G., Brandes, A., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01698-6 · Cited by 550
Metadata
- Authors
- Gladstone, D. J., Wachter, R., Schmalstieg-Bahr, K., Quinn, F. R., Hummers, E., Ivers, N., Marsden, T., Thornton, A., Djuric, A., Suerbaum, J., von Grünhagen, D., McIntyre, W. F., Benz, A. P., Wong, J. A., Merali, F., Henein, S., Nichol, C., Connolly, S. J., Healey, J. S., & SCREEN-AF Investigators and Coordinators
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2021-05-01
- Volume
- 6
- Issue
- 5
- Pages
- 558
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W3129415548
- Cited by
- 195
- References
- 72
- FWCI
- 21.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.