Cited by 7ECG Monitoring and AnalysisArtificial Intelligence in HealthcareArtificial Intelligence in Healthcare and Education

Artificial Intelligence Electrocardiogram and Left Ventricular Systolic Dysfunction in Kenya

Open access
Pandey, Ambarish, Keshvani, Neil, Segar, Matthew W., Kwon, Joon-myoung, Lee, Hak Seung, Bhograj, Charit, Mashilane, Khomotso Itumeleng, Jain, Nipun +17 more·2026·JAMA Cardiology

Abstract

Importance Early detection of risk of heart failure with reduced ejection fraction remains challenging in resource-limited settings due to limited access to echocardiography. Artificial intelligence electrocardiogram (AI-ECG) algorithms have demonstrated promise for identifying left ventricular systolic dysfunction (LVSD), but their feasibility in resource-constrained settings remains unknown. Objective To determine the frequency of patients in Kenya with a high probability of LVSD by AI-ECG and assess AI-ECG algorithm performance against the gold standard of echocardiography. Design, setting, and participants This was a cross-sectional study with enrollment from June to December 2024. Participants underwent baseline assessment and 12-lead ECG, and a subset completed echocardiography within 7 days. The echocardiography subset included participants from 3 prespecified risk strata: those with prior cardiovascular disease, those at high cardiovascular risk (Framingham Risk Score [FRS] ≥10%), and those at low risk (FRS Exposure Risk of LVSD was identified using a validated convolutional neural network AI-ECG algorithm (AiTiALVSD). Main outcomes and measures Key outcomes were the diagnostic performance (sensitivity, specificity, and positive and negative predictive values) of the AI-ECG algorithm for detecting LVSD (LVEF Results Among 1444 participants (mean [SD] age, 59.0 [16.7] years; 907 [62.8%] female; 1118 [77.4%] at high risk), LVSD was identified in 204 (14.1%). The AI-ECG…

Integrity signals

Registry

Crossref · 10.1001/jamacardio.2026.0908

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A highly sensitive AI-ECG could help prioritize limited imaging resources for patients most likely to benefit from confirmatory echocardiography.

    “This type of performance is clinically relevant because a highly sensitive AI-ECG could help prioritize limited imaging resources for patients most likely to benefit from confirmatory echocardiography.”
  • An AI-ECG algorithm for detecting left ventricular systolic dysfunction in Kenyan outpatient facilities had high sensitivity and negative predictive value compared with echocardiography.

    “A recent study in Kenyan outpatient facilities evaluated an AI-ECG algorithm for detecting left ventricular systolic dysfunction and reported high sensitivity and negative predictive value compared with echocardiography [23].”
  • Validation in Kenyan outpatient facilities illustrates that AI-ECG could help prioritize scarce echocardiography and specialist resources and may extend cardiovascular screening beyond tertiary centers in settings where treatable disease is frequently recognized late.

    “Validation in Kenyan outpatient facilities illustrates how AI-ECG could help prioritize scarce echocardiography and specialist resources, and it may extend cardiovascular screening beyond tertiary centers in settings where treatable disease is frequently recognized late [23].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Pandey, A., Keshvani, N., Segar, M. W., Kwon, J.-M., Lee, H. S., Bhograj, C., Mashilane, K. I., Jain, N., Mwiti, W., Wambari, E., Nguchu, H., Wagana-Muriithi, L. N., Anyira, E., Namasaka, P., Mbau, L., Wairagu, A., Muthui-Mutua, B., Bikoro, M., Mwita, M. C. R., Njeri, I., Gituma, B., Mbogo, D., Ngolobe, A., Nabiswa, H., & Samia, B.
Affiliations
  • The University of Texas Southwestern Medical Center (US)
  • Heart Hospital Baylor Plano (US)
  • Department of Cardiology, Texas Heart Institute, Houston, Texas
  • Medical AI Co, Seoul, Korea
  • Tricog Health Inc, Bengaluru, India
  • AstraZeneca (United Kingdom) (GB)
  • Kenyatta National Hospital (KE)
  • The Mountain Springs Medical Centre, Nyeri, Kenya
  • Masinde Muliro University of Science and Technology (KE)
  • Jomo Kenyatta University of Agriculture and Technology (KE)
  • Kenya Cardiac Society, Nairobi, Kenya
  • Gatundu Referral Hospital, Gatundu, Kenya
  • Mama Lucy Referral Hospital, Nairobi, Kenya
  • Chogoria Mission Hospital, Chogoria, Kenya
  • Kiambu Referral Hospital, Kiambu, Kenya
  • Mbagathi Referral Hospital, Nairobi, Kenya
  • Thika Referral Hospital, Thika, Kenya
  • M.P. Shah Hospital Nairobi, Kenya
Venue
JAMA Cardiology
Published
2026-06-01
Volume
11
Issue
6
Pages
554
ISSN
2380-6583 (ISSN-L)
OpenAlex
W7160404391
Cited by
7
References
37
Citations by year
2026: 7
FWCI
34.71
Type
journal article
Language
en
Open access
Locations
  • JAMA Cardiology (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
left ventricular systolic dysfunction, heart failure with reduced ejection fraction, convolutional neural networks, echocardiography, diagnostic accuracy, resource-limited settings, cardiovascular risk, Framingham risk score, Kenya, early detection of heart failure, positive predictive value, sensitivity and specificity, high cardiovascular risk
MeSH terms
Adult, Algorithms, Artificial Intelligence, Cross-Sectional Studies, Echocardiography, Electrocardiography, Female, Humans, Kenya, Male, Middle Aged, ROC Curve, Ventricular Dysfunction, Left

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review