The DOI matches its Crossref record; 24 of the 26 references it cites were found in a registry or an index, and 1 are not checked yet.
Analysis of Discrepancies Between Pulse Oximetry and Arterial Oxygen Saturation Measurements by Race and Ethnicity and Association With Organ Dysfunction and Mortality
Open accessAbstract
Importance: Discrepancies in oxygen saturation measured by pulse oximetry (Spo2), when compared with arterial oxygen saturation (Sao2) measured by arterial blood gas (ABG), may differentially affect patients according to race and ethnicity. However, the association of these disparities with health outcomes is unknown. Objective: To examine racial and ethnic discrepancies between Sao2 and Spo2 measures and their associations with clinical outcomes. Design, Setting, and Participants: This multicenter, retrospective, cross-sectional study included 3 publicly available electronic health record (EHR) databases (ie, the Electronic Intensive Care Unit-Clinical Research Database and Medical Information Mart for Intensive Care III and IV) as well as Emory Healthcare (2014-2021) and Grady Memorial (2014-2020) databases, spanning 215 hospitals and 382 ICUs. From 141 600 hospital encounters with recorded ABG measurements, 87 971 participants with first ABG measurements and an Spo2 of at least 88% within 5 minutes before the ABG test were included. Exposures: Patients with hidden hypoxemia (ie, Spo2 ≥88% but Sao2 <88%). Main Outcomes and Measures: Outcomes, stratified by race and ethnicity, were Sao2 for each Spo2, hidden hypoxemia prevalence, initial demographic characteristics (age, sex), clinical outcomes (in-hospital mortality, length of stay), organ dysfunction by scores (Sequential Organ Failure Assessment [SOFA]), and laboratory values (lactate and creatinine levels) before and 24 hours after the ABG measurement. Results: The first Spo2-Sao2 pairs from 87 971 patient encounters (27 713 [42.9%] women; mean [SE] age, 62.2 [17.0] years; 1919 [2.3%] Asian patients; 26 032 [29.6%] Black patients; 2397 [2.7%] Hispanic patients, and 57 632 [65.5%] White patients) were analyzed, with 4859 (5.5%) having hidden hypoxemia. Hidden hypoxemia was observed in all subgroups with varying incidence (Black: 1785 [6.8%]; Hispanic: 160 [6.0%]; Asian: 92 [4.8%]; White: 2822 [4.9%]) and was associated with greater organ dysfunction 24 hours after the ABG measurement, as evidenced by higher mean (SE) SOFA scores (7.2 [0.1] vs 6.29 [0.02]) and higher in-hospital mortality (eg, among Black patients: 369 [21.1%] vs 3557 [15.0%]; P < .001). Furthermore, patients with hidden hypoxemia had higher mean (SE) lactate levels before (3.15 [0.09] mg/dL vs 2.66 [0.02] mg/dL) and 24 hours after (2.83 [0.14] mg/dL vs 2.27 [0.02] mg/dL) the ABG test, with less lactate clearance (-0.54 [0.12] mg/dL vs -0.79 [0.03] mg/dL). Conclusions and Relevance: In this study, there was greater variability in oxygen saturation levels for a given Spo2 level in patients who self-identified as Black, followed by Hispanic, Asian, and White. Patients with and without hidden hypoxemia were demographically and clinically similar at baseline ABG measurement by SOFA scores, but those with hidden hypoxemia subsequently experienced higher organ dysfunction scores and higher in-hospital mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2. Modified Bland-Altman Plots by Race and Ethnicity On each plot, the bold horizontal lines represent the mean bias (defined as the difference between the oxygen saturation measured by pulse oximetry [Spo2] and arterial blood gas value [Sao2]) for each of the 2 Spo2 groups. The blue lines, with dashed blue lines indicating 95% CIs, are for the group with Spo2 of 88% to 92%, and the orange lines, with dashed orange lines indicating 95% CIs, for the group with Spo2 of 93% to 96%. The solid black line indicates the absence of bias (ie, Spo2 − Sao2 = 0). When the mean bias is above the black line, there is positive bias in the pulse oximetry measurement (ie, the observed Spo2 is greater than the true Sao2). In contrast, when the mean bias is below the black line, there is negative bias in the pulse oximetry measurement (ie, the observed Spo2 is below the true Sao2).](/paper-figures/66f4dbf06a1b43b598a12906dc016ab7/analysis-of-discrepancies-between-pulse-oximetry-and-arterial-oxygen-saturation-figure-2.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“leading to lower hospital admission; higher occult hypoxemia; and delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality [11-18].”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [15]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
The cited source says what the claim attributes to it.
In the citing paper
“Patients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [15]
In the citing paper
“More recent studies have also revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeters devices, resulting in overestimations [17,49,50,51,52,53] with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%) [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
In the citing paper
“Due to this increasing evidence, several health organizations and healthcare professionals have raised growing concerns about the clinical accuracy of pulse oximetry in dark-skinned patients [20,57,58,59,60,61], particularly in detecting occult hypoxemia [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
In the citing paper
“A prevalence of occult hypoxemia in dark-skinned subjects has been recently confirmed in three studies, showing that dark-skinned patients may have over three times the risk of experiencing occult hypoxemia during hospitalization compared to light-skinned patients [53,54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674
MIMIC-III, a freely accessible critical care database
Johnson, A. E. W., Pollard, T. J., Shen, L., Lehman, L.-W. H., Feng, M., Ghassemi, M., Moody, B., Szolovits, P., Anthony Celi, L., & Mark, R. G. (2016) · Scientific Data · doi:10.1038/sdata.2016.35 · Cited by 8,141
Vandenbroucke, J. P., Elm, E. V., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S. J., Poole, C., Schlesselman, J. J., Egger, M., & initiative, F. T. S. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-8-200710160-00010-w1 · Cited by 3,543
The Triad of Sleep Apnea, Hypertension, and Chronic Kidney Disease: A Spectrum of Common Pathology
Aziz, F., & Chaudhary, K. R. (2016) · Cardiorenal Medicine · doi:10.1159/000450796 · Cited by 3,285
Pollard, T. J., Johnson, A. E. W., Raffa, J. D., Celi, L. A., Mark, R. G., & Badawi, O. (2018) · Scientific Data · doi:10.1038/sdata.2018.178 · Cited by 1,993
Racial bias in pulse oximetry measurement
Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E., & Valley, T. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2029240 · Cited by 1,114
Jansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894
Intermittent Hypoxemia and OSA
Dewan, N. A., Nieto, F. J., & Somers, V. K. (2015) · Chest · doi:10.1378/chest.14-0500 · Cited by 641
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
Cited by
Sorted by citations
Items 201–268 of 268
Zhang, K., Han, Y., Gu, F., Gu, Z., liang, J., Zhao, J., zhang, T., Gao, M., Hou, Z., Cai, T., et al. (2023) · Research Square · doi:10.21203/rs.3.rs-3427589/v1
Pulse Oximeters, why a multi-wavelength approach could be used to detect other biomarkers?
Ochoa-Gutierrez, V. J., Guerrero‐Zúñiga, S., Reboud, J., Harvey, A. R., & Cooper, J. M. (2023) · Frontiers in Optics · doi:10.1364/fio.2023.jm4a.65
Nelson, B. W., Singh, S., Bennett, M., Chen, C., Shin, S., & Ghanbari, H. (2024) · Research Square · doi:10.21203/rs.3.rs-3882498/v1
Mettler, S. K., Charoenngam, N., Jaroenlapnopparat, A., Tern, C., Xanthavanij, N., Economidou, S. C., Strand, M. J., Hobbs, B. D., Moll, M. R., & Cho, M. H. (2024) · medRxiv · doi:10.1101/2024.03.28.24305036
ENCoDE – a skin tone and clinical dataset from a prospective trial on acute care patientsPreprint
Hao, S., de Matos, J. C. R. G., Dempsey, K., Alwakeel, M., Houghtaling, J., Hong, C., Gichoya, J. W., Kibbe, W. A., Pencina, M. J., Cox, C. E., et al. (2024) · medRxiv · doi:10.1101/2024.08.07.24311623
Oxygenation targets in critically ill children: the Oxy-PICU trial
Chen, A., Chen, X., Huang, S., & Zheng, X. (2024) · The Lancet · doi:10.1016/s0140-6736(24)01560-5
Author Response: Oxygenation Indices in Adult COVID ARDS Patients
Vadi, S. M., Sanwalka, N. J., & Suthar, D. (2024) · Indian Journal of Critical Care Medicine · doi:10.5005/jp-journals-10071-24790
Le syndrome de détresse respiratoire aiguë : définition mondiale et nouvelles recommandations
Girault, C. (2024) · Revue des Maladies Respiratoires Actualités · doi:10.1016/s1877-1203(24)00061-2
Pulse Oximetry: A Vital Tool with Important Functional Limitations for Patients with Dark Skin Color
Harris, D. E. (2024) · Universal Library of Clinical Nursing · doi:10.70315/uloap.ulcnu.2024.0101005
Case Study: Long-Term Monitoring of Health Biomarkers after Drinking Structured Water Over 43 Months
Ramsey, C. L. (2024) · Journal of Basic & Applied Sciences · doi:10.29169/1927-5129.2024.20.16
Labban, M. E., Zibaoui, R. E., Eid, K., Mansour, P., Wehbe, M., Farah, W. H., & Odeyemi, Y. (2025) · Respiratory Care · doi:10.1089/respcare.12213
The Saga of Equitable Oxygen Saturation Measurement Continues: The Role of Arterial Blood Gases
Chesley, C. F., & Anesi, G. L. (2025) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202502-0339ed
Racial Differences in Temporal Thermometry and Association with Delayed Sepsis Bundle CarePreprint
de Matos, J. C. R. G., Alwakeel, M. I., Hao, S., Martins, I. S., Cardoso, J. S., Gichoya, J. W., Celi, L. A., Lane, A., Krishnamoorthy, V., Bhavani, S. V., et al. (2025) · medRxiv · doi:10.1101/2025.03.31.25324893
Bose, S., Binda, D. D., Ramachandran, S. K., & Nafiu, O. O. (2025) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000007522
Pannu, S. R., Peters, J., Zimmer, J., Brock, G. N., Exline, M. C., Horowitz, J. C., Thompson, B., Rice, T. W., & Crouser, E. D. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-094924 · Cited by 1
Partial waiver of consent to overcome translational science barriers in neonatal clinical research
Sharma, M., Diamond, S. E., Chancellor, J., Chung, S., Brown, A. W., Hester, D. M., James, L. P., Schootman, M., Mourani, P. M., & Courtney, S. E. (2025) · Journal of Clinical and Translational Science · doi:10.1017/cts.2025.10122
Agomuo, S. A., Chinawa, J. M., Ujunwa, F., Anarado, C. F., Nnajekwu, U. C., Adiele, D. K., Okosi, V. C., Chukwu, E. O., & Okafor, H. U. (2025) · BMC Nephrology · doi:10.1186/s12882-025-04472-x
Reaching Individualized Optimal Oxygen Therapy in Mechanically Ventilated Patients
Xu, C., Nie, X., & Wang, D. (2025) · JAMA · doi:10.1001/jama.2025.14077
Sato, R., Ito, N., Kadomatsu, S., Hanioka, N., Nakajima, M., & Goto, T. (2025) · PLoS ONE · doi:10.1371/journal.pone.0334350
Macedo, B., McDonald, J., Dash, A., Nephew, L. D., Serper, M., Marrero, J. A., & Siddique, S. M. (2025) · Gastro Hep Advances · doi:10.1016/j.gastha.2025.100773
Clinical Trials of Physiological Monitors: Learning from the Mistakes of the Past
Ortoleva, J. P., Wieruszewski, P. M., Pisano, D. V., & Bittner, E. A. (2025) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2025.11.026
Bersten, A. D., & Morgan, T. J. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-11611-7.00038-4
Acute respiratory distress syndrome
Bersten, A. D., & Bihari, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-11611-7.00037-2
AI-Driven SaO2 prediction from pulse oximetry and electronic health records
Woo, J., Stapleton, O., Luo, J. X. J., Chuang, C. C., Su, Y., Sankararaman, S., Mukherjee, E., Sivakumar, N., Calligy, K., Duffy, S., et al. (2025) · BioData Mining · doi:10.1186/s13040-025-00511-3 · Cited by 1
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495940
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495958
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495979
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495961
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495955
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495967
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495964
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495943
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495988
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495982
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495970
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495949
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495973
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495976
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495946
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495937
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495991
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495985
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495994
Moreno, R., Rhodes, A., Piquilloud, L., Glenn Hernández, P., Takala, J. A., Gershengorn, H. B., Tavares, M., Coopersmith, C. M., Myatra, S. N., Singer, M., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22603861
Holder, A. L., Abgrall, G., Xiao, R., Kpodonu, J., Nanayakkara, S., Dankwa‐Mullan, I., Zalucky, A. A., Monnet, X., & Goligher, E. C. (2025) · CHEST Critical Care · doi:10.1016/j.chstcc.2025.100215
Zhang, Y., Chen, X., Zhang, Y., Ma, Z., Zhao, L., & Zhang, H. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2025.1667172
Sari, L. S., Karuniawaty, T. P., Wiguna, P. A., & Parwata, W. S. S. (2025) · Jurnal Penelitian Pendidikan IPA · doi:10.29303/jppipa.v11i9.12299
Skin tone and clinical dataset from a prospective trial on acute care patients
Hao, S., de Matos, J. C. R. G., Dempsey, K., Alwakeel, M., Houghtaling, J., Hong, C., Gichoya, J. W., Kibbe, W., Pencina, M. J., Cox, C. E., et al. (2026) · Scientific Data · doi:10.1038/s41597-025-06457-9
Strengthening the Evidence on Intraoperative Occult Hypoxemia
Jabaley, C. S., Wong, A.-K. I., & O’Reilly-Shah, V. N. (2026) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000008014
Wu, J., Rathod, M., Voigt, B., & Franklin, D. (2026) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.3081183
From AI Bias to AI by Us: A Case Study from MIT Critical Data
Bielick, C. G., Gameiro, R. R., & Celi, L. A. (2026) · Springer eBooks · doi:10.1007/978-3-032-07830-8_17
Low-cost point-of-care wireless multimodal wearable to monitor vitals and tissue oxygen saturation
Nguyen, T. K., George, T. M., Veluvolu, V. D., Azar, T. S., Frankenberg, A., Park, J., Park, J., Martin, W. S., Khaksari, K., Shadgan, B., et al. (2026) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae637f
AI-Driven Entrepreneurship: Catalyzing Green and Inclusive Growth in Africa
Edogun, D. I. (2026) · Frontiers in African business research · doi:10.1007/978-981-95-9500-6_3
Zhou, B., Rodriguez, S. H., Warren, A., & Skondra, D. (2026) · Experimental Biology and Medicine · doi:10.3389/ebm.2026.11094
Pilot Study: Using Reflectance as a Proxy for Skin Pigmentation to Assess Pulse Oximeter Accuracy
Branstad, A., Buttar, S., Kabir, R., Byrapuneni, S., Eid, M., Sandozi, A., BELTRAND, E., Evans, M. D., Joy, B. F., Goertzen, L., et al. (2026) · Hospital Pediatrics · doi:10.1542/hpeds.2025-008471
Sottile, P. D., Mikkelsen, M. E., Peterson, R., McGrath, M., Carlson, N., Higgins, C., Clinton, M. I., Barbour, A., Kautz, S., Kwan, B., et al. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-110023
Wearable systems for real-time disease diagnosis and predictive analytics
Huynh, P. K., Nguyen, D. H., Liu, H., Marahatta, S., Olaniran, O., Nguyen, D., Truong, T. T., Huynh, P., Keshwani, A., Prioli, J. P. J., et al. (2026) · Elsevier eBooks · doi:10.1016/b978-0-44-331426-1.00018-8
Achieving Equity in Generative Artificial Intelligence in Cardiovascular Medicine
Kulkarni, A., & Visweswaran, S. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.102967
Ali, F., Shaw, A., Bell-Scollan, E., Hayman, K., Griffiths, S., Dodd, Z., Luchsinger, D., Pauly, B., Waldman, M., Dookie, S. P., et al. (2026) · International Journal of Drug Policy · doi:10.1016/j.drugpo.2026.105418
Patel, M. S., Emedom-Nnamdi, P., Lapen, K., & Dee, E. C. (2026) · Journal of General Internal Medicine · doi:10.1007/s11606-026-10576-3
Zhang, H., & Jetley, G. (2026) · Production and Operations Management · doi:10.1177/10591478261474395
Hendrickson, C. M., Lipnick, M. S., Chen, D., Chen, D., Law, T. J., Pirracchio, R., Feiner, J., Behnke, E., Chou, Y., Elmankabadi, S., et al. (2026) · CHEST Critical Care · doi:10.1016/j.chstcc.2026.100305 · Cited by 2
Sex Differences in Cardiovascular Risk with Obstructive Sleep Apnea
Bock, J. M. (2026) · Physiology in health and disease · doi:10.1007/978-3-032-26472-5_17
Wang, C.-L., & Liu, C. (2026) · Clinical Nursing Research · doi:10.1177/10547738261473668
A Multi-Model Analysis of Non-Invasive Oxygen Saturation from Smartphone-Captured Fingertip Video
Sabith, N. U. S., Ahamad, M. M., Arefin, K. Z., Rabbani, M., & Ahamed, S. I. (2026) · IEEE International Conference on Digital Health (ICDH) · doi:10.1109/icdh72779.2026.00022
Gao, X., Wang, J., Xiong, L., Hu, B., Jiang, C., Li, J., Chen, S., & Zhang, C. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1935082
Shu, X., & Wen, X. (2026) · Biosensors · doi:10.3390/bios16100565
Occult hypoxemia in the ICU: Clinical risk factors, mortality and implications for nursing practice
Caillet, A., Vacheron, C., Dargent, A., & Allaouchiche, B. (2026) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2026.104594
Metadata
- Authors
- Wong, A.-K. I., Charpignon, M., Kim, H., Josef, C., de Hond, A. A. H., Fojas, J. J., Tabaie, A., Liu, X., Mireles-Cabodevila, E., Carvalho, L., Kamaleswaran, R., Madushani, R. W. M. A., Adhikari, L., Holder, A. L., Steyerberg, E. W., Buchman, T. G., Lough, M. E., & Celi, L. A.
- Affiliations
- Emory University (US)
- Massachusetts Institute of Technology (US)
- Johns Hopkins University (US)
- Leiden University Medical Centre, Department of Biomedical Data Sciences, Leiden, the Netherlands
- Beth Israel Deaconess Medical Center (US)
- Beihang University (CN)
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
- Cleveland Clinic (US)
- Boston Medical Center (US)
- Philips (United States) (US)
- Leiden University Medical Center (NL)
- Stanford Health Care (US)
- Corresponding author
- Wong, An-Kwok Ian
- ORCID
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2021-11-03
- Volume
- 4
- Issue
- 11
- Pages
- e2131674
- ISSN
- 2574-3805 (ISSN-L)
- PMC
- PMC9178439
- OpenAlex
- W3210241905
- Cited by
- 268
- References
- 25
- Citations by year
- 2026: 26 · 2025: 53 · 2024: 62 · 2023: 67 · 2022: 60
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JAMA Network Open (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Leiden Repository (Leiden University) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, cc-by)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- Funders
- U.S. Department of Defense
- National Institutes of Health (5r01eb017205-07, R01-EB017205, EB017205, NIBIB R01 EB017205, UL1TR002378)
- Uniformed Services University of the Health Sciences (HT9404-13-1-0032, HU0001, USUHS HT9404-13-1-0032, HU0001-15-2-0001)
- Biomedical Advanced Research and Development Authority
- National Institute of General Medical Sciences (K23GM137182, T32GM095442, R01GM139967)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB R01 EB017205, R01-EB017205, EB017205)
- National Center for Advancing Translational Sciences
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Keywords
- pulse oximetry, arterial oxygen saturation, racial and ethnic disparities, arterial blood gases, intensive care unit patients, organ dysfunction, SOFA score, in-hospital mortality, length of hospital stay, lactate, creatinine, Black patients, Hispanic patients, health disparities, hypoxemia detection
- MeSH terms
- Oxygen Saturation, Aged, Hypoxia, Creatinine, Cross-Sectional Studies, Ethnicity, Female, Georgia, Humans, Male, Middle Aged, Multiple Organ Failure, Oximetry, Retrospective Studies, Racial Groups
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review